Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cell Line”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Development of the Lidar Atmospheric Sensing Experiment (LASE): An Advanced Airborne DIAL Instrument

The Lidar Atmospheric Sensing Experiment (LASE) Instrument is the first fully-engineered, autonomous Differential Absorption Lidar (DIAL) System for the measurement of water vapor in the troposphere (aerosol and cloud measurements are included). LASE uses a double-pulsed Ti:Sapphire laser for the transmitter with a 30 ns pulse length and 150 mJ/pulse. The laser beam is "seeded" to operate on a selected water vapor absorption line in the 815-nm region using a laser diode and an onboard absorption reference cell. A 40 cm diameter telescope collects the backscattered signals and directs them onto two detectors. LASE collects DIAL data at 5 Hz while onboard a NASA/Ames ER-2 aircraft flying at altitudes from 16-21 km. LASE was designed to operate autonomously within the environment and physical constraints of the ER-2 aircraft and to make water vapor profile measurements across the troposphere to better than 10% accuracy. LASE has flown 19 times during the development of the instrument and the validation of the science data. This paper describes the design, operation, and reliability of the LASE Instrument.

Moore, Alvah S., Jr.↗

Accuracy, Scalability, and Efficiency of Mixed-Element USM3D for Benchmark Three-Dimensional Flows

The unstructured, mixed-element, cell-centered, finite-volume flow solver USM3D is enhanced with new capabilities including parallelization, line generation for general unstructured grids, improved discretization scheme, and optimized iterative solver. The paper reports on the new developments to the flow solver and assesses the accuracy, scalability, and efficiency. The USM3D assessments are conducted using a baseline method and the recent hierarchical adaptive nonlinear iteration method framework. Two benchmark turbulent flows, namely, a subsonic separated flow around a three-dimensional hemisphere-cylinder configuration and a transonic flow around the ONERA M6 wing are considered.

Pandya, Mohagna J.↗

Efficiency of Mixed-Element USM3D for Benchmark Three-Dimensional Flows

The unstructured, mixed-element, cell-centered, finite-volume flow solver USM3D is enhanced with new capabilities such as line generation for general unstructured grids and optimization of the iterative solver. The efficiency of the new developments is assessed in a massively parallel environment. The assessments are conducted using a baseline method and the recent hierarchical adaptive nonlinear iteration method framework. Three benchmark turbulent flows, namely, a subsonic separated flow around a three-dimensional hemisphere cylinder configuration, a transonic flow around the ONERA M6 wing, and a supersonic flow through a square duct are considered.

Mohagna J Pandya↗

Local Ultrasonic Resonance Spectroscopy of Lithium Metal Batteries for Aerospace Applications

As next-generation aircraft and vehicles continue to develop, so do their associated energy demands. Lithium metal batteries are a leading candidate to fulfill this energy requirement, but these batteries are prone to internal dendrite defects that can lead to catastrophic thermal runaway events. Current battery management systems are capable of mitigating such risks, but are unable to detect such defects until thermal runaway has already begun. Various nondestructive evaluation (NDE) techniques, particularly ultrasonic NDE, can directly monitor internal battery parameters giving them the potential to detect critical defects prior to catastrophic failure. However, most of the current battery NDE research has focused on improved battery state-of-charge (SOC) and stateof- health (SOH) monitoring with little emphasis on critical defect detection. Thus, a measurement technique sensitive to subtle battery defects is needed. In addition, the complex mechanics of ultrasound in porous, thin, multilayered batteries prompt the use of physics-based simulation to guide inspections. In this work, an ultrasonic NDE technique has been developed utilizing frequency domain analysis of local battery resonances to detect the presence of battery defects. This technique is a practical extension of local ultrasonic resonance spectroscopy (LURS) – which previously required non-contact laser ultrasonics – to measurements with piezoelectric contact and immersion scan transducers. To extend the technique to work with piezoelectric transducers, ultrasonic battery measurements were compared to a sans-battery calibration measurement. Then, a linear systems deconvolution was used to eliminate the transfer functions of extraneous factors such as the transducer and electronics, leaving only the frequency-dependent battery reflection coefficient. The LURS technique was first validated on stainless steel and aluminum plates, producing reflection coefficients in line with analytical and numerical finite element modeling (FEM) results. Functioning Li-metal pouch cells were then seeded with lithium chip defects prior to LURS measurements. The presence of these defects is shown to cause a measurable shift in the battery’s through-thickness local resonances. 2D, frequency-domain poroelastic models of ultrasonic propagation in a single-cell lithium metal pouch battery were created and corroborated these findings. Thus, this work has both extended and proven the feasibility of the LURS technique in the detection of local battery defects.

Ultrasound↗

Time optimal paths and acceleration lines of robotic manipulators

The concept of acceleration lines and their correlation with time-optimal paths of robotic manipulators is presented. The acceleration lines represent the directions of maximum tip acceleration from a point in the manipulator work-space, starting at a zero velocity. These lines can suggest the number and shapes of time-optimal paths for a class of manipulators. It is shown that nonsingular time-optimal paths are tangent to one of the acceleration lines near the end-points. A procedure for obtaining near-optimal paths, utilizing the acceleration lines, is developed. These paths are obtained by connecting the end-points with B splines tangent to the acceleration lines. The near-minimum paths are shown to yield better traveling times than the straight-line path between the same end-points. The near-minimum paths can be used as initial conditions in existing optimization methods to speed-up convergence and computation time. This method can be used for online robot path planning and for interactive designs of robotic-cell layouts. Examples of time-optimal paths of a two-link manipulator, obtained by other optimization procedures and their acceleration lines, are shown.

Shiller, Zvi↗

Solar cell spectral response characterization

The absolute spectral response of solar cells is reported in the 400-1000-nm spectral region. Measurements were performed using two different types of monochromatic sources: amplitude-stabilized CW laser lines and interference filters with an incandescent lamp. Both types of calibration procedures use electrical substitution radiometry as the basis of traceability to absolute SI units. The accuracy of the calibration is shown to be limited by the nonideal characteristics of the solar cells themselves, specifically spatial nonuniformities and nonlinearities induced by high light levels.

Zalewski, E. F.↗

Cesium oscillator strengths measured with a multiple-path-length absorption cell

Absorption-oscillator-strength measurements for the principal series in cesium were measured using a multiple-path-length cell. The optical arrangement included a movable transverse path for checking the uniformity of the alkali density along the length of the cell and which also allowed strength measurements to be made simultaneously on both strong and weak lines. The strengths measured on the first 10 doublets indicate an increasing trend in the doublet ratio. The individual line strengths are in close agreement with the high resolution measurements of Pichler (1974) and with the calculations of Norcross (1973).

Exton, R. J.↗

Determining the Point of Zero Zeta Potential in Solid Samples

Technique for measuring pzzp in solid samples incorporates sample in photochemical cell and measures temperature dependence of flatband potential. Pzzp is obtained from slope of best straight line through measured points. Tests agree well with expected values. In technique sample does not have to be in powder form.

Byvik, C. E.↗

Observed structural variability of deep moist convection within a mesoscale convective system

Some radar observations of the convective cloud structure within and around a developing mesoscale convective system (MCS), which attained an eventual horizontal dimension of approximately 100 by 200 km, are reported. Similarities in cloud structure within and outside the MCS include a downshear tilt of the cloud precipitation core and generation of new cells toward the direction of cloud motion and parallel to the major axis of the cloud line. The systematic difference in the longevity and intensity of the clouds is examined.

Knupp, Kevin R.↗

Herman-Wallis factors in the C2H2nu5 infrared fundamental near 14 microns

The presence of acetylene has been confirmed for some time in the atmospheres of the outer planets Jupiter, Saturn, Neptune, and Saturn's satellite Titan. For these atmospheres, the determination of C2H2 abundances using its strong nu5 fundamental requires laboratory line position and intensity measurements. The 1-m Fourier transform spectrometer at McMath solar telescope of Kitt Peak National Observatory was used to measure C2H2 at an unapodized spectral resolution of 0.0025/cm. Synthetic spectra are generated by convolving a Voigt line shape with an instrument function and varying intensity parameters by means of a nonlinear least squares technique. Intensities of 37 nu5 lines spanning P18 through R20 were measured using 0.123 torr of gas in a 1-cm cell. A Herman-Wallis intensity correction parameter of 1.3(4) x 10 to the -3rd has been derived using a least squares linear fit.

Maguire, William C.↗

The No Vibrational Fundamental Band: Temperature Dependence of N2-Broadening Coefficients

Rovibrational spectra of the vibrational fundamental of nitric oxide have been recorded under N2-broadening conditions at 0.0056 cm(exp-1) resolution using the Solar McMath FTS at the Kitt Peak National Observatory. The temperature range for the experiments was 296 K to 183 K. The 30 cm absorption cell used for the measurements is cooled with a helium compressor and can operate at temperatures down to 60 K; vibration isolation of the cell allows its use with high performance Fourier Transform Spectrometers. From these spectra, N2-broadened line widths have been determined thru m = 16.5. Qualitative as well as quantitative discrepancies are observed between our experimental determinations of the temperature dependence of the broadening and theoretical calculations.

Spencer, M. N.↗

Large-Aperture Membrane Active Phased-Array Antennas

Large-aperture phased-array microwave antennas supported by membranes are being developed for use in spaceborne interferometric synthetic aperture radar systems. There may also be terrestrial uses for such antennas supported on stationary membranes, large balloons, and blimps. These antennas are expected to have areal mass densities of about 2 kg/sq m, satisfying a need for lightweight alternatives to conventional rigid phased-array antennas, which have typical areal mass densities between 8 and 15 kg/sq m. The differences in areal mass densities translate to substantial differences in total mass in contemplated applications involving aperture areas as large as 400 sq m. A membrane phased-array antenna includes patch antenna elements in a repeating pattern. All previously reported membrane antennas were passive antennas; this is the first active membrane antenna that includes transmitting/receiving (T/R) electronic circuits as integral parts. Other integral parts of the antenna include a network of radio-frequency (RF) feed lines (more specifically, a corporate feed network) and of bias and control lines, all in the form of flexible copper strip conductors on flexible polymeric membranes. Each unit cell of a prototype antenna (see Figure 1) contains a patch antenna element and a compact T/R module that is compatible with flexible membrane circuitry. There are two membrane layers separated by a 12.7-mm air gap. Each membrane layer is made from a commercially available flexible circuit material that, as supplied, comprises a 127-micron-thick polyimide dielectric layer clad on both sides with 17.5-micron-thick copper layers. The copper layers are patterned into RF, bias, and control conductors. The T/R module is located on the back side of the ground plane and is RF-coupled to the patch element via a slot. The T/R module is a hybrid multilayer module assembled and packaged independently and attached to the membrane array. At the time of reporting the information for this article, an 8 16 passive array (not including T/R modules) and a 2 4 active array (including T/R modules) had been demonstrated, and it was planned to fabricate and test larger arrays.

Karasik, Boris↗

Skin-Based DNA Repair Phenotype for Cancer Risk from GCR in Genetically Diverse Populations

Predicting cancer risk associated with cosmic radiation remains a mission-critical challenge for NASA radiation health scientists and mission planners. Epidemiological data are lacking and risk methods do not take individual radiation sensitivity into account. In our approach we hypothesize that genetic factors strongly influence risk of cancer from space radiation and that biomarkers reflecting DNA damage and cell death are ideal tools to predict risk and monitor potential health effects post-flight. At this workshop, we will be reporting the work we have done over the first 9 months of this proposal. Skin cells from 15 different strains of mice already characterized for radiation-induced cancer sensitivity (B6C3F; BALB/cByJ, C57BL/6J, CBA/CaJ, C3H/HeMsNrsf), and 10 strains from the DOE collaborative cross-mouse model were expanded from ear biopsy and cultivated until Passage 3. On average, 3 males and 3 females for each strain were expanded and frozen for further characterization at the NSRL beam line during the NSRL16C run for three LET (350 MeV/n Si, 350 MeV/n Ar and 600 MeV/n Fe) and two ion fluences (1 and 3 particles per cell). The mice work has established new metrics for the usage of Radiation Induced Foci as a marker for various aspect of DNA repair deficiencies. In year 2, we propose to continue characterization of the mouse lines with low LET to identify loci specific to high- versus low- LET and establish genetic linkage for the various DNA repair biomarkers. Correlation with cancer risk from each animals strain and gender will also be investigated. On the human side, we will start characterizing the DNA damage response induced ex-vivo in 200 human's blood donors for radiation sensitivity with a tentative 500 donors by the end of this project. All ex-vivo phenotypic data will be correlated to genetic characterization of each individual human donors using SNP arrays characterization as done for mice. Similarly, ex-vivo phenotypic features from mice will be associated to cancer risk, to identify which biomarkers correlate the most with cancer risk. Genetic traits across humans will also be associated to radiation phenotypic features as a function of age and gender.

radiation space biology↗

Emitter formation in dendritic web silicon solar cells

The use of liquid dopants and liquid masks for p-n junction formation in dendritic web solar cells was investigated and found to be equivalent to the use of gaseous dopants and CVD SiO2 masks previously used. This results in a projected cost reduction of 0.02 1980$/Watt for a 25 MW/year production line, and makes possible junction formation processes having a higher throughput than more conventional processes. The effect of a low-energy (0.4 keV) hydrogen ion implant on dendritic web solar cells was also investigated. Such an implant was observed to improve Voc and Jsc substantially. Measurements of internal quantum efficiency suggest that it is the base of the cell, rather than the emitter, which benefits from the hydrogen implant. The diffusion length for electrons in the p-type base increased from 53 microns to 150 microns in one case, with dendritic web cell efficiency being boosted to 15.2 percent. The mechanism by which low-energy hydrogen ions can penetrate deeply into the silicon to effect the observed improvement is not known at this time.

Meier, D. L.↗

White cell design considerations

The White cell is a unit-magnification image relay system consisting of three noncoaxial spherical mirrors of equal curvature. The cell is used to provide a long optical path in a relatively small physical space. Multiple reflections are used, in a manner similar to a unstable laser resonator. A particular application is an optical delay line on the input of a streak camera to allow for the finite triggering time of the sweep start. This paper addresses the first- and third-order properties of the White cell. A displacement sensitivity analysis is included.

Hannan, Paul↗

The observation and interpretation of the profile of C IV lambda-1548 emitted from a quiet region of the sun

The average properties of the quiet chromospheric network as seen in the transition region line of C IV at 1548 A have been investigated. Line profile data for the study were taken with the OSO 8 High Resolution Ultraviolet Spectrometer, which has moderate angular resolution, high spectral resolution, and good relative photometric accuracy. The profiles, when classified and averaged according to their intensities, were found to be symmetric and Gaussian in shape at all intensity levels. A marginally significant increase in line width with line intensity was detected but the average relative redshift in the network that has been a feature of other OSO 8 studies was not found. The network-to-cell contrast ratio was of the order of 13:1 with the extreme extending to 50.1. The measured average width of 0.22 A (FWHM) is in good agreement with earlier work. Finally, a theoretical interpretation is presented, based on both the line width measurement and consideration of the profile symmetry properties. It is concluded that acoustic waves alone cannot supply enough energy to balance the radiative and conductive losses from the corona. The data are, however, consistent with heating by Alfven waves.

Bruner, E. C., Jr.↗

Properties of solid polymer electrolyte fluorocarbon film

The ionic fluorocarbon film used as the solid polymer electrolyte in hydrogen/oxygen fuel cells was found to exhibit delamination failures. Polarized light microscopy of as-received film showed a lined region at the center of the film thickness. It is shown that these lines were not caused by incomplete saponification but probably resulted from the film extrusion process. The film lines could be removed by an annealing process. Chemical, physical, and tensile tests showed that annealing improved or sustained the water contents, spectral properties, thermo-oxidative stability, and tensile properties of the film. The resistivity of the film was significantly decreased by the annealing process.

Alston, W. B.↗

The optical pumping of alkali atoms using coherent radiation from semi-conductor injection lasers and incoherent radiation from resonance lamps

An experimental study for creating population differences in the ground states of alkali atoms (Cesium 133) is presented. Studies made on GaAs-junction lasers and the achievement of population inversions among the hyperfine levels in the ground state of Cs 133 by optically pumping it with radiation from a GaAs diode laser. Laser output was used to monitor the populations in the ground state hyperfine levels as well as to perform the hyperfine pumping. A GaAs laser operated at about 77 K was used to scan the 8521 A line of Cs 133. Experiments were performed both with neon-filled and with paraflint-coated cells containing the cesium vapor. Investigations were also made for the development of the triple resonance coherent pulse technique and for the detection of microwave induced hyperfine trasistions by destroying the phase relationships produced by a radio frequency pulse. A pulsed cesium resonance lamp developed, and the lamp showed clean and reproducible switching characteristics.

Singh, G.↗