Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capillary Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Design, development and test of a capillary pump loop heat pipe

The development of a capillary pump loop (CPL) heat pipe, including computer modeling and breadboard testing, is presented. The computer model is a SINDA-type thermal analyzer, combined with a pressure analyzer, which predicts the transients of the CPL heat pipe during operation. The breadboard is an aluminum/ammonia transport system which contains multiple parallel evaporator and condenser zones within a single loop. Test results have demonstrated the practicality and reliability of such a design, including heat load sharing among evaporators, liquid inventory/temperature control feature, and priming under load. Transport capability for this system is 65 KW-M with individual evaporator pumps managing up to 1.7 KW at a heat flux of 15 W/sq cm. The prediction of the computer model for heat transport capabilities is in good agreement with experimental results.

Kroliczek, E. J.↗

Modeling Adsorption in Silica Pores via Minkowski Functionals and Molecular Electrostatic Moments

Capillary condensation phenomena are important in various technological and environmental processes. Using molecular simulations, we study the confined phase behavior of fluids relevant to carbon sequestration and shale gas production. As a first step toward translating information from the molecular to the pore scale, we express the thermodynamic potential and excess adsorption of methane, nitrogen, carbon dioxide, and water in terms of the pore’s geometric properties via Minkowski functionals. This mathematical reconstruction agrees very well with molecular simulations data. Our results show that the fluid molecular electrostatic moments are positively correlated with the number of adsorption layers in the pore. Moreover, stronger electrostatic moments lead to adsorption at lower pressures. These findings can be applied to improve pore-scale thermodynamic and transport models.

42 ENGINEERING↗

Economic method for measuring ultra-low flow rates of fluids

Capillary tube flowmeter measures ultra-low flows of very corrosive fluids /such as chlorine trifluoride and liquid fluorine/ and other liquids with reasonable accuracy. Flowmeter utilizes differential pressure transducer and operates on the principle that for laminar flow in the tube, pressure drop is proportional to flow rate.

Bogdanovic, J. A.↗

A hydroponic method for plant growth in microgravity

A hydroponic apparatus under development for long-term microgravity plant growth is described. The capillary effect root environment system (CERES) is designed to keep separate the nutrient and air flows, although both must be simultaneously available to the roots. Water at a pressure slightly under air pressure is allowed to seep into a plastic depression covered by a plastic screen and a porous membrane. A root in the air on the membrane outer surface draws the moisture through it. The laboratory model has a wire-based 1.241 mm mesh polyethylene screen and a filter membrane with 0.45 micron pores, small enough to prohibit root hair penetration. The design eliminates the need to seal-off the plant environment. Problems still needing attention include scaling up of the CERES size, controlling biofouling of the membrane, and extending the applications to plants without fibrous root systems.

Wright, B. D.↗

Jet-A fuel evaporation analysis in conical tube injectors

A simple one-dimensional drop-life-history analysis and a multidimensional spray calculation using KIVA-II code are applied to the vaporization of Jet-A fuel in multiple tube injectors. Within the assumptions of the analysis, the one-dimensional results are useful for design purposes. The pressure-atomizer breakup models do not accurately predict the dropsize measured experimentally or deduced from the one-dimensional analysis. Cold flow visualization and dropsize measurements show that capillary wave breakup mechanism plays an important role in the spray angle and droplet impingement on the tube wall.

Lai, M.-C.↗

Atmospheric-pressure ionization and fragmentation of molecules for structural elucidation

A solution-cathode glow discharge mass spectrometry (SCGD-MS) apparatus comprises a SCGD source and a mass spectrometer. The SCGD source may comprise conductive rods, a power source, and a capillary. A method for ionizing an analyte comprises flowing an electrically conductive liquid onto a conductive rod, applying an electric potential to a second conductive rod such that a plasma discharge forms between the first conductive rod and the electrically conductive liquid to produce ions, and separating the ions in a mass spectrometer. The analyte may be a polypeptide that may be contacted with trypsin. The analyte may be a solid, liquid, gas, chemical complex, or ion in solution. The method may comprise sequencing the polypeptide.

Shelley, Jacob T.↗

Three Dimensional Flow and Pressure Patterns in a Single Pocket of a Hydrostatic Journal Bearing

The flow in a hydrostatic pocket is described by a mathematical model that uses the three dimensional Navier-Stokes equations written in terms of the primary variables, u, v, w, and p. Using a conservative formulation, a finite volume multi-block method is applied through a collocated, body fitted grid. The flow is simulated in a shallow pocket with a depth/length ratio of 0.02. The flow structures obtained and described by the authors in their previous two dimensional models are made visible in their three dimensional aspect for the Couette flow. It has been found that the flow regimes formed central and secondary vortical cells with three dimensional corkscrew-like structures that lead the fluid on an outward bound path in the axial direction of the pocket. The position of the central vortical cell center is at the exit region of the capillary restrictor feedline. It has also been determined that a fluid turn around zone occupies all the upstream space between the floor of the pocket and the runner, thus preventing any flow exit through the upstream port. The corresponding pressure distribution under the shaft presented as well. It was clearly established that for the Couette dominated case the pressure varies significantly in the pocket in the circumferential direction, while its variation is less pronounced axially.

Braun, M. Jack↗

Windowless microfluidic platform based on capillary burst valves for high intensity x-ray measurements

We propose and describe a microfluidic system for high intensity x-ray measurements. The required open access to a microfluidic channel is provided by an out-of-plane capillary burst valve (CBV). The functionality of the out-of-plane CBV is characterized with respect to the diameter of the windowless access hole, ranging from 10 to 130 {mu}m. Maximum driving pressures from 22 to 280 mbar corresponding to refresh rates of the exposed sample from 300 Hz to 54 kHz is demonstrated. The microfluidic system is tested at beamline ID09b at the ESRF synchrotron radiation facility in Grenoble, and x-ray scattering measurements are shown to be feasible and to require only very limited amounts of sample, <1 ml/h of measurements without recapturing of sample. With small adjustments of the present chip design, scattering angles up to 30 deg. can be achieved without shadowing effects and integration on-chip mixing and spectroscopy appears straightforward.

43 PARTICLE ACCELERATORS↗

Water transport properties of virtual fractal porous media: Implications for the unsaturated transport properties of cement-based materials

Cement-based materials are more and more recognized as fractal materials. From a practical point of view, fractality means that the pore size distribution can be described using fractal scaling law (i.e. power functions). Here, the simplest scaling law making use of a single fractal dimension was used to generate simple and virtual fractal porous media (based on bundles of parallel cylindrical pores). The capillary curve and permeability (relative and intrinsic) of the virtual porous media were then estimated through theoretical and numerical approaches. The results show that: (1) although bereft of any physical basis, van Genuchten equation bears some fractal information; (2) although highly flexible, van Genuchten equation fails to perfectly fit the capillary curves and can thus generate error in inverse analysis (for intrinsic permeability evaluation) and (3) there seems to be a relation between the intrinsic permeability and van Genuchten pressure parameter.

36 MATERIALS SCIENCE↗

Multilevel Morphology of Complex Nanoporous Materials

This work exploits gas adsorption and small-angle X-ray scattering (SAXS) to determine the morphology of complex nanoporous materials. We resolve multiple classes of porosity including previously undetected large-scale texture that significantly compromises the canonical interpretation of gas adsorption. Specifically, a UVM-7 class mesoporous silica was synthesized that has morphological features on three length scales: macropores due to packing of 150 nm globules, 1.9 nm radius spherical mesopores inside the globules, and >7 nm pockets on and between the globules. The total and external surface areas, as well as the mesopore volume, were determined using gas adsorption (α s -plot) and SAXS. A new approach was applied to the SAXS data using multilevel fitting to determine the surface areas on multiple length scales. The SAXS analysis code is applicable to any two-phase system and is freely available to the public. The total surface area determined by SAXS was 12% greater than that obtained by gas adsorption. The macropore interfacial area, however, is only 30% of the external surface area determined by the α s -plot. The overestimation of the external surface area by the αs-plot method is attributed to capillary condensation in nanoscale surface irregularities. Here, the discrepancy is resolved assuming that the macropore–globule interfaces harbor fractally distributed nooks and crannies, which lead to gas adsorption at pressures above the mesopore filling pressure.

36 MATERIALS SCIENCE↗

Interfacial gauge methods for incompressible fluid dynamics

Designing numerical methods for incompressible fluid flow involving moving interfaces, for example, in the computational modeling of bubble dynamics, swimming organisms, or surface waves, presents challenges due to the coupling of interfacial forces with incompressibility constraints. A class of methods, denoted interfacial gauge methods, is introduced for computing solutions to the corresponding incompressible Navier-Stokes equations. These methods use a type of "gauge freedom" to reduce the numerical coupling between fluid velocity, pressure, and interface position, allowing high-order accurate numerical methods to be developed more easily. Making use of an implicit mesh discontinuous Galerkin framework, developed in tandem with this work, high-order results are demonstrated, including surface tension dynamics in which fluid velocity, pressure, and interface geometry are computed with fourth-order spatial accuracy in the maximum norm. Applications are demonstrated with two-phase fluid flow displaying fine-scaled capillary wave dynamics, rigid body fluid-structure interaction, and a fluid-jet free surface flow problem exhibiting vortex shedding induced by a type of Plateau-Rayleigh instability. The developed methods can be generalized to other types of interfacial flow and facilitate precise computation of complex fluid interface phenomena.

42 ENGINEERING↗

Hindlimb Suspension as a Model to Study Ophthalmic Complications in Microgravity Status Report: Optimization of Rat Retina Flat Mounts Staining to Study Vascular Remodeling

Preliminary data from a prior tissue‐sharing experiment has suggested that early growth response protein‐1 (Egr1), a transcription factor involved in various stress responses in the vasculature, is induced in the rat retina after 14 days of hindlimb suspension (HS) and may be evidence that mechanical stress is occurring secondary to the cephalad fluid shift. This mechanical stress could cause changes in oxygenation of the retina, and the subsequent ischemia‐ or inflammation‐driven hypoxia may lead to microvascular remodeling. This microvascular remodeling process can be studied using image analysis of retinal vessels and can be then be quantified by the VESsel GENeration Analysis (VESGEN) software, a computational tool that quantifies remodeling patterns of branching vascular trees and capillary or vasculogenic networks. Our project investigates whether rodent HS is a valid model to study the effects of simulated‐weightlessness on ocular structures and their relationship with intracranial pressure (ICP). One of the hypotheses to be tested is that HS‐induced cephalad fluid shift is accompanied by vascular engorgement that produces changes in retinal oxygenation, leading to oxidative stress, hypoxia, microvascular remodeling, and cellular degeneration. We have optimized the procedure to obtain flat mounts of rat retina, staining of the endothelial lining in vasculature and acquisition of high quality images suitable for VESGEN analysis. Briefly, eyes were fixed in 4% paraformaldehyde for 24 hours and retinas were detached and then mounted flat on microscope slides. The microvascular staining was done with endothelial cell‐specific isolectin binding, coupled to Alexa‐488 fluorophore. Image acquisition at low magnification and high resolution was performed using a new Leica SP8 confocal microscope in a tile pattern across the X,Y plane and multiple sections along the Z‐axis. This new confocal microscope has the added capability of dye separation using the Linear Unmixing method and allows us to remove the autofluorescence originating from the photoreceptor layer. In summary, we have an improved method for studying the retinal microvasculature that will provide an increase in the quality of images captured and will be applied throughout the various animal cohorts of the recentlyinitiated study that will evaluate rodent HS as a model to study ophthalmic complications in microgravity.

Theriot, Corey A.↗

Sockeye Heat Pipe Analysis Code Verification and Validation

Some of the most promising microreactor designs currently under development utilize heat pipe technology to transfer heat from the reactor core to the secondary side heat exchanger, due to the technology’s compactness, efficiency, passivity, and reliability. Sockeye is an engineering-scale heat pipe tool developed under the Nuclear Energy Advanced Modeling and Simulation Program to be used for the design and safety analysis of microreactors. Sockeye’s core capability lies in a 1D, two-phase, compressible flow model, used to simulate the working fluid inside the heat pipe. Sockeye is built on the Multiphysics Object-Oriented Simulation Environment framework, which allows for seamless multiphysics coupling with other Nuclear Energy Advanced Modeling and Simulation tools and can thus be used in a full-scale simulation of a microreactor assembly, which can include hundreds of heat pipes. This paper presents some initial verification and validation assessments performed for Sockeye. We demonstrate good agreement between Sockeye’s numerical results and steady-state analytic solutions for velocity and pressure drop, with differences attributable to the underlying assumptions made by the analytic solutions. We also show that Sockeye reproduces analytic predictions of key operational limits, such as the capillary limit and the sonic limit. Finally, we compare Sockeye results to experimental data for the SAFE-30 heat pipe module test.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Capillary instability in a two-component Bose-Einstein condensate

Capillary instability and the resulting dynamics in an immiscible two-component Bose-Einstein condensate are investigated using the mean-field and Bogoliubov analyses. A long, cylindrical condensate surrounded by the other component is dynamically unstable against breakup into droplets due to the interfacial tension arising from the quantum pressure and interactions. A heteronuclear system confined in a cigar-shaped trap is proposed for realizing this phenomenon experimentally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pattern of filling in the pulmonary capillary bed.

Artificially ventilated and perfused dog lungs were rapidly frozen under various physiological conditions. In 2-micron-thick sections the number of red blood cells (RBCs) per 10-micron length of alveolar septum was counted. Under conditions in which alveolar pressure exceeded venous pressure, variation in RBC concentration within areas supplied by single arterioles accounted completely for variation between areas supplied by different arterioles. Except at very high perfusion pressures when venous pressure exceeded alveolar pressure, there was no significant correlation between RBC concentrations of pairs of adjacent septa.

Warrell, D. A.↗

Microplasma-based flowing atmospheric-pressure afterglow (FAPA) source for ambient desorption-ionization mass spectrometry

A new direct-current microplasma-based flowing atmospheric pressure afterglow (FAPA) source was developed for use in ambient desorption-ionization mass spectrometry. The annular-shaped microplasma is formed in helium between two concentric stainless-steel capillaries that are separated by an alumina tube. Current-voltage characterization of the source shows that this version of the FAPA operates in the normal glow-discharge regime. A glass surface placed in the path of the helium afterglow reaches temperatures of up to approximately 400 °C; the temperature varies with distance from the source and helium flow rate through the source. Solid, liquid, and vapor samples were examined by means of a timeof- flight mass spectrometer. Results suggest that ionization occurs mainly through protonation, with only a small amount of fragmentation and adduct formation. Here, the mass range of the source was shown to extend up to at least m/z 2722 for singly charged species. Limits of detection for several small organic molecules were in the sub-picomole range. Examination of competitive ionization revealed that signal suppression occurs only at high (mM) concentrations of competing substances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An augmented Young-Laplace model of an evaporating meniscus in a micro-channel with high heat flux

High flux evaporations from a steady meniscus formed in a 2 micron channel is modeled using the augmented Young-Laplace equation. The heat flux is found to be a function of the long range van der Waals dispersion force which represents interfacial conditions between heptane and various substrates. Heat fluxes of (1.3-1.6) x 10(exp 6) W/m(exp 2) based on the width of the channel are obtained for heptane completely wetting the substrate at 100 C. Small channels are used to obtain these large fluxes. Even though the real contact angle is 0 deg, the apparent contact angle is found to vary between 24.8 deg and 25.6 deg. The apparent contact angle, which represents viscous losses near the contact line, has a large effect on the heat flow rate because of its effect on capillary suction and the area of the meniscus. The interfacial heat flux is modeled using kinetic theory for the evaporation rate. The superheated state depends on the temperature and the pressure of the liquid phase. The liquid pressure differs from the pressure of the vapor phase due to capillarity and long range van der Waals dispersion forces which are relevant in the ultra think film formed at the leading edge of the meniscus. Important pressure gradients in the thin film cause a substantial apparent contact angle for a complete wetting system. The temperature of the liquid is related to the evaporation rate and to the substrate temperature through the steady heat conduction equation. Conduction in the liquid phase is calculated using finite element analysis except in the vicinity of the thin film. A lubrication theory solution for the thin film is combined with the finite element analysis by the method of matched asymptotic expansions.

Wayner, P. C., Jr.↗

Microgravity-Induced Physiological Fluid Redistribution: Computational Analysis to Assess Influence of Physiological Parameters

Space flight impacts human physiology in many ways, the most immediate being the marked cephalad (headward) shift of fluid upon introduction into the microgravity environment. This physiological response to microgravity points to the redistribution of blood and interstitial fluid as a major factor in the loss of venous tone and reduction in heart muscle efficiency which impact astronaut performance. In addition, researchers have hypothesized that a reduction in astronaut visual acuity, part of the Visual Impairment and Intracranial Pressure (VIIP) syndrome, is associated with this redistribution of fluid. VIIP arises within several months of beginning space flight and includes a variety of ophthalmic changes including posterior globe flattening, distension of the optic nerve sheath, and kinking of the optic nerve. We utilize a suite of lumped parameter models to simulate microgravity-induced fluid redistribution in the cardiovascular, central nervous and ocular systems to provide initial and boundary data to a 3D finite element simulation of ocular biomechanics in VIIP. Specifically, the lumped parameter cardiovascular model acts as the primary means of establishing how microgravity, and the associated lack of hydrostatic gradient, impacts fluid redistribution. The cardiovascular model consists of 16 compartments, including three cerebrospinal fluid (CSF) compartments, three cranial blood compartments, and 10 thoracic and lower limb blood compartments. To assess the models capability to address variations in physiological parameters, we completed a formal uncertainty and sensitivity analysis that evaluated the relative importance of 42 input parameters required in the model on relative compartment flows and compartment pressures. Utilizing the model in a pulsatile flow configuration, the sensitivity analysis identified the ten parameters that most influenced each compartment pressure. Generally, each compartment responded appropriately to parameter variations associated with itself and adjacent compartments. However, several unexpected interactions between components, such as between the choroid plexus and the lower capillaries, were found, and are due to simplifications in the formulation of the model. The analysis illustrates that highly influential parameters and those that have unique influences within the model formulation must be tightly controlled for successful model application.

gravitational physiology↗