Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Tail-Cone Thruster Fan Rotor Flutter Analysis

The aeroelastic stability of a tail cone thruster fan was analyzed for three structural modes and various nodal diameter patterns. Computational fluid dynamics modeling with blade vibrations was used in the analyses performed at design (peak-efficiency) and two near-stall conditions at the design rotational speed. Aerodynamic damping was used to assess flutter since this integrally bladed rotor design will have minimal structural damping. Aerodynamic damping was found to be low at the design condition. For the first mode, aerodynamic damping was seen to decrease towards stall, vanishing for a zero nodal diameter pattern. Further decrease in mass flow led to negative aerodynamic damping (flutter) for the first and second nodal diameters in the near stall condition. The flowfield at this lowest mass flow rate exhibited some additional unsteadiness at higher frequency. The sensitivity of results to time step and amplitudes of vibration was examined and found to be very satisfactory. The largest uncertainty in the results comes from the observed sensitivity of the aerodynamic damping to details of the variation of grid deformations in the blade passage mesh from the blade passage to the boundaries. For the parametric variations analyzed, the calculated aerodynamic damping is lower if the grid deformations near the blade surface are higher. Further work is needed to understand the cause of this sensitivity and find possible solutions to reduce the effects on flutter predictions.

Fan↗

Single Dirac Cone Topological Surface State and Unusual Thermoelectric Property of Compounds from a New Topological Insulator Family

Angle resolved photoemission spectroscopy (ARPES) study on TlBiTe2 and TlBiSe2 from a Thallium-based III-V-VI2 ternary chalcogenides family revealed a single surface Dirac cone at the center of the Brillouin zone for both compounds. For TlBiSe{sub 2}, the large bulk gap ({approx} 200meV) makes it a topological insulator with better mechanical properties than the previous binary 3D topological insualtor family. For TlBiTe{sub 2}, the observed negative bulk gap indicates it as a semi-metal, rather than a narrow gap semi-conductor as conventionally believed; this semi-metality naturally explains its mysteriously small thermoelectric figure of merit comparing to other compounds in the family. Finally, the unique band structures of TlBiTe{sub 2} also suggests it as a candidate for topological superconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Extremal Surfaces and the Holographic Entropy Cone

Quantum states with geometric duals are known to satisfy a stricter set of entropy inequalities than those obeyed by general quantum systems. The set of allowed entropies derived using the Ryu-Takayanagi (RT) formula defines the Holographic Entropy Cone (HEC). These inequalities are no longer satisfied once general quantum corrections are included by employing the Quantum Extremal Surface (QES) prescription. Nevertheless, the structure of the QES formula allows for a controlled study of how quantum contributions from bulk entropies interplay with HEC inequalities. In this paper, we initiate an exploration of this problem by relating bulk entropy constraints to boundary entropy inequalities. In particular, we show that requiring the bulk entropies to satisfy the HEC implies that the boundary entropies also satisfy the HEC. Further, we also show that requiring the bulk entropies to obey monogamy of mutual information (MMI) implies the boundary entropies also obey MMI.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beyond the Holographic Entropy Cone via Cycle Flows

Motivated by bit threads, we introduce a new prescription for computing entropy vectors outside the holographic entropy cone. By utilizing cycle flows on directed graphs, we show that the maximum cycle flow associated to any subset of vertices, which corresponds to a subsystem, manifestly obeys purification symmetry. Furthermore, by restricting ourselves to a subclass of directed graphs, we prove that the maximum cycle flow obeys both subadditivity and strong subadditivity, thereby establishing it as a viable candidate for the entropy associated to the subsystem. Lastly, we demonstrate how our model generalizes the entropy vectors obtainable via conventional flows in undirected graphs, as well as conjecture that our model similarly generalizes the entropy vectors arising from hypergraphs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of Corona Enhancement of Hypervascular Hepatocellular Carcinoma by C-Arm Dual-Phase Cone-Beam CT During Hepatic Arteriography

The purpose of this study was to evaluate the detectability of corona enhancement around the hypervascular hepatocellular carcinoma (HCC) by dual-phase cone-beam computed tomography during hepatic arteriography (CBCTHA). Dual-phase CBCTHA was performed for 71 HCC lesions (mean {+-} SD 1.7 {+-} 0.9 cm), including seven presenting a nodule-in-nodule appearance and nine hypervascular pseudolesions. The first scan was performed during injection of 30-40 ml half-diluted contrast material at a rate of 1.5-2 ml/s through the hepatic artery. Scanning was initiated 7 s after the beginning of contrast material injection. The second scan was started 30 s after the end of the first scan. Detectability of corona enhancement on second-phase CBCTHA was evaluated. Thickness of corona enhancement was also analyzed as thin ({<=}2 mm) or thick (>2 mm). Corona enhancement was detected in 63 (88.7%) of 71 tumors (1.8 {+-} 0.9 cm), but it was not detected in eight tumors (1.0 {+-} 0.2 cm). Thin corona enhancement was seen in 18 tumors (1.2 {+-} 0.5 cm), and thick corona enhancement was seen in 45 tumors (2.0 {+-} 0.9 cm). There was a significant difference in tumor diameter between tumors with and those without corona enhancement (P = 0.0157) and between thin and thick corona enhancement (P = 0.001). In all seven early-stage tumors, corona enhancement was demonstrated around the hypervascular focus within the hypovascular tumor portion. None of the nine pseudolesions showed any corona enhancement. Dual-phase CBCTHA depicted corona enhancement in 88.7% of hypervascular HCC lesions. This technique may improve the diagnostic accuracy of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing the Detectability of Hepatocellular Carcinoma by C-Arm Dual-Phase Cone-Beam Computed Tomography During Hepatic Arteriography With Conventional Contrast-Enhanced Magnetic Resonance Imaging

Purpose: To evaluate the sensitivity of dual-phase cone-beam computed tomography during hepatic arteriography (CBCTHA) for the detection of hepatocellular carcinoma (HCC) by comparing it with the diagnostic imaging 'gold standard': contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver. Materials and Methods: Eighty-eight HCC lesions (mean diameter 3.9 {+-} 3.3 cm) in 20 patients (13 men, mean age 61.4 years [range 50 to 80]), who sequentially underwent baseline diagnostic liver CE-MRI and then underwent early arterial- and delayed portal venous-phase CBCTHA during drug eluting-bead transarterial chemoembolization, were evaluated. Dual-phase CBCTHA findings of each tumor in terms of conspicuity were compared with standard CE-MR images and classified into three grades: optimal, suboptimal, and nondiagnostic. Results: Seventy-seven (mean diameter 4.2 {+-} 3.4 cm [range 0.9 to 15.9]) (93.9%) of 82 tumors were detected. Sensitivity of arterial-phase (71.9%) was lower than that of venous-phase CBCTHA (86.6%) for the detection of HCC lesions. Of the 82 tumors, 33 (40.2%) and 52 (63.4%), 26 (31.7%) and 19 (23.2%), and 23 (28%) and 11 (13.4%) nodules were classed as optimal, suboptimal, and nondiagnostic on arterial- and venous-phase CBCTHA images, respectively. Seventeen (73.9%) of the 23 tumors that were not visible on arterial phase were detected on venous phase. Six (54.5%) of the 11 tumors that were not visible on venous phase were detected on arterial phase. Conclusions: Dual-phase CBCTHA has sufficient image quality to detect the majority of HCC lesions compared with the imaging 'gold standard': CE-MRI of the liver. Moreover, dual-phase CBCTHA is more useful and reliable than single-phasic imaging to depict HCC nodules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-beam Computed Tomography-guided Stereotactic Liver Punctures: A Phantom Study

Purpose: Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. Methods: Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPE{sub CBCT}) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPE{sub CBCT-CT} from fused datasets. Image coregistration was evaluated using fiducial registration error (FRE{sub CBCT-CT}) and target registration error (TRE{sub CBCT-CT}). Results: Positioning accuracies in lateral directions pertaining to CBCT (TPE{sub CBCT} = 2.1 {+-} 1.0 mm) were found to be better to those achieved from previous study using CT (TPE{sub CT} = 2.3 {+-} 1.3 mm). Image coregistration error was 0.3 {+-} 0.1 mm, resulting in an average TRE of 2.1 {+-} 0.7 mm (N = 5 targets) and average Euclidean TPE{sub CBCT-CT} of 3.1 {+-} 1.3 mm. Conclusions: Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Exposure of Abdominal Cone Beam Computed Tomography

PurposeTo evaluate patients radiation exposure of abdominal C-arm cone beam computed tomography (CBCT).MethodsThis prospective study was approved by the institutional review board; written, informed consent was waived. Radiation exposure of abdominal CBCT was evaluated in 40 patients who underwent CBCT during endovascular interventions. Dose area product (DAP) of CBCT was documented and effective dose (ED) was estimated based on organ doses using dedicated Monte Carlo simulation software with consideration of X-ray field location and patients’ individual body weight and height. Weight-dependent ED per DAP conversion factors were calculated. CBCT radiation dose was compared to radiation dose of procedural fluoroscopy. CBCT dose-related risk for cancer was assessed.ResultsMean ED of abdominal CBCT was 4.3 mSv (95 % confidence interval [CI] 3.9; 4.8 mSv, range 1.1–7.4 mSv). ED was significantly higher in the upper than in the lower abdomen (p = 0.003) and increased with patients’ weight (r = 0.55, slope = 0.045 mSv/kg, p < 0.001). Radiation exposure of CBCT corresponded to the radiation exposure of on average 7.2 fluoroscopy minutes (95 % CI 5.5; 8.8 min) in the same region of interest. Lifetime risk of exposure related cancer death was 0.033 % or less depending on age and weight.ConclusionsMean ED of abdominal CBCT was 4.3 mSv depending on X-ray field location and body weight.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Registration of Cone-Beam Computer Tomography and Preprocedural Computer Tomography Aids in Localization of Adrenal Veins and Decreasing Radiation Dose in Adrenal Vein Sampling

PurposeWe assessed whether image registration of cone-beam computed tomography (CT) (CBCT) and contrast-enhanced CT (CE-CT) images indicating the locations of the adrenal veins can aid in increasing the success rate of first-attempts adrenal vein sampling (AVS) and therefore decreasing patient radiation dose.Materials and Methods CBCT scans were acquired in the interventional suite (Philips Allura Xper FD20) and rigidly registered to the vertebra in previously acquired CE-CT. Adrenal vein locations were marked on the CT image and superimposed with live fluoroscopy and digital-subtraction angiography (DSA) to guide the AVS. Seventeen first attempts at AVS were performed with image registration and retrospectively compared with 15 first attempts without image registration performed earlier by the same 2 interventional radiologists. First-attempt AVS was considered successful when both adrenal vein samples showed representative cortisol levels. Sampling time, dose-area product (DAP), number of DSA runs, fluoroscopy time, and skin dose were recorded.ResultsWithout image registration, the first attempt at sampling was successful in 8 of 15 procedures indicating a success rate of 53.3 %. This increased to 76.5 % (13 of 17) by adding CBCT and CE-CT image registration to AVS procedures (p = 0.266). DAP values (p = 0.001) and DSA runs (p = 0.026) decreased significantly by adding image registration guidance. Sampling and fluoroscopy times and skin dose showed no significant changes.ConclusionGuidance based on registration of CBCT and previously acquired diagnostic CE-CT can aid in enhancing localization of the adrenal veins thereby increasing the success rate of first-attempt AVS with a significant decrease in the number of used DSA runs and, consequently, radiation dose required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize the tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Delayed-Phase Cone-Beam CT Improves Detectability of Intrahepatic Cholangiocarcinoma During Conventional Transarterial Chemoembolization

PurposeTo evaluate the detectability of intrahepatic cholangiocarcinoma (ICC) on dual-phase cone-beam CT (DPCBCT) during conventional transarterial chemoembolization (cTACE) compared to that of digital subtraction angiography (DSA) with respect to pre-procedure contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.MethodsThis retrospective study included 17 consecutive patients (10 male, mean age 64) with ICC who underwent pre-procedure CE-MRI of the liver, and DSA and DPCBCT (early-arterial phase (EAP) and delayed-arterial phase (DAP)) just before cTACE. The visibility of each ICC lesion was graded by two radiologists on a three-rank scale (complete, partial, and none) on DPCBCT and DSA images, and then compared to pre-procedure CE-MRI.ResultsOf 61 ICC lesions, only 45.9 % were depicted by DSA, whereas EAP- and DAP-CBCT yielded a significantly higher detectability rate of 73.8 % and 93.4 %, respectively (p < 0.01). Out of the 33 lesions missed on DSA, 18 (54.5 %) and 30 (90.9 %) were revealed on EAP- and DAP-CBCT images, respectively. DSA depicted only one lesion that was missed by DPCBCT due to streak artifacts caused by a prosthetic mitral valve. DAP-CBCT identified significantly more lesions than EAP-CBCT (p < 0.01). Conversely, EAP-CBCT did not detect lesions missed by DAP-CBCT. For complete lesion visibility, DAP-CBCT yielded significantly higher detectability (78.7 %) compared to EAP (31.1 %) and DSA (21.3 %) (p < 0.01).ConclusionDPCBCT, and especially the DAP-CBCT, significantly improved the detectability of ICC lesions during cTACE compared to DSA. We recommend the routine use of DAP-CBCT in patients with ICC for per-procedure detectability and treatment planning in the setting of TACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam Computed Tomography (CBCT) Hepatic Arteriography in Chemoembolization for Hepatocellular Carcinoma: Performance Depicting Tumors and Tumor Feeders

PurposeThis study was designed to analyze retrospectively the performance of cone-beam computed tomography (CBCT) hepatic arteriography in depicting tumors and their feeders and to investigate the related determining factors in chemoembolization for hepatocellular carcinoma (HCC).MethodsEighty-six patients with 142 tumors satisfying the imaging diagnosis criteria of HCC were included in this study. The performance of CBCT hepatic arteriography for chemoembolization per tumor and per patient was evaluated using maximum intensity projection images alone (MIP analysis) or MIP combined with multiplanar reformation images (MIP + MPR analysis) regarding the following three aspects: tumor depiction, confidence of tumor feeder detection, and trackability of tumor feeders. Tumor size, tumor enhancement, tumor location, number of feeders, diaphragmatic motion, portal vein enhancement, and hepatic artery to parenchyma enhancement ratio were regarded as potential determining factors.ResultsTumors were depicted in 125 (88.0 %) and 142 tumors (100 %) on MIP and MIP + MPR analysis, respectively. Imaging performances on MIP and MIP + MPR analysis were good enough to perform subsegmental chemoembolization without additional angiographic investigation in 88 (62.0 %) and 128 tumors (90.1 %) on per-tumor basis and in 43 (50 %) and 73 (84.9 %) on per-patient basis, respectively. Significant determining factors for performance in MIP + MPR analysis on per tumor basis were tumor size (p = 0.030), tumor enhancement (0.005), tumor location (p = 0.001), and diaphragmatic motion (p < 0.001).ConclusionsCBCT hepatic arteriography provided sufficient information for subsegmental chemoembolization by depicting tumors and their feeders in the vast majority of patients. Combined analysis of MIP and MPR images was essential to enhance the performance of CBCT hepatic arteriography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam Computed Tomography (CBCT) Versus CT in Lung Ablation Procedure: Which is Faster?

AimTo compare cone-beam CT (CBCT) versus computed tomography (CT) guidance in terms of time needed to target and place the radiofrequency ablation (RFA) electrode on lung tumours.Materials and MethodsPatients at our institution who received CBCT- or CT-guided RFA for primary or metastatic lung tumours were retrospectively included. Time required to target and place the RFA electrode within the lesion was registered and compared across the two groups. Lesions were stratified into three groups according to their size (<10, 10–20, >20 mm). Occurrences of electrode repositioning, repositioning time, RFA complications, and local recurrence after RFA were also reported.ResultsForty tumours (22 under CT, 18 under CBCT guidance) were treated in 27 patients (19 male, 8 female, median age 67.25 ± 9.13 years). Thirty RFA sessions (16 under CBCT and 14 under CT guidance) were performed. Multivariable linear regression analysis showed that CBCT was faster than CT to target and place the electrode within the tumour independently from its size (β = −9.45, t = −3.09, p = 0.004). Electrode repositioning was required in 10/22 (45.4 %) tumours under CT guidance and 5/18 (27.8 %) tumours under CBCT guidance. Pneumothoraces occurred in 6/14 (42.8 %) sessions under CT guidance and in 6/16 (37.5 %) sessions under CBCT guidance. Two recurrences were noted for tumours receiving CBCT-guided RFA (2/17, 11.7 %) and three after CT-guided RFA (3/19, 15.8 %).ConclusionCBCT with live 3D needle guidance is a useful technique for percutaneous lung ablation. Despite lesion size, CBCT allows faster lung RFA than CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone Beam Computed Tomography (CBCT) in the Field of Interventional Oncology of the Liver

Cone beam computed tomography (CBCT) is an imaging modality that provides computed tomographic images using a rotational C-arm equipped with a flat panel detector as part of the Angiography suite. The aim of this technique is to provide additional information to conventional 2D imaging to improve the performance of interventional liver oncology procedures (intraarterial treatments such as chemoembolization or selective internal radiation therapy, and percutaneous tumor ablation). CBCT provides accurate tumor detection and targeting, periprocedural guidance, and post-procedural evaluation of treatment success. This technique can be performed during intraarterial or intravenous contrast agent administration with various acquisition protocols to highlight liver tumors, liver vessels, or the liver parenchyma. The purpose of this review is to present an extensive overview of published data on CBCT in interventional oncology of the liver, for both percutaneous ablation and intraarterial procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗