Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSION TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methodology for Mechanical Property Testing of Fuel Cladding Using a Expanded Plug Wedge Test

An expanded plug method was developed earlier for determining the tensile properties of irradiated fuel cladding. This method tests fuel rod cladding ductility by utilizing an expandable plug to radially stretch a small ring of irradiated cladding material. The circumferential or hoop strain is determined from the measured diametrical expansion of the ring. A developed procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves, from which material properties of the cladding can be extracted. However, several deficiencies existed in this expanded-plug test that can impact the accuracy of test results, such as that the large axial compressive stress resulted from the expansion plug test can potentially induce the shear failure mode of the tested specimen. Moreover, highly nonuniform stress and strain distribution in the deformed clad gage section and significant compressive stresses, induced by bending deformation due to clad bulging effect, will further result in highly nonconservative estimates of the mechanical properties for both strength and ductility of the tested clad. To overcome the aforementioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. By optimizing the specific geometry designs, selecting the appropriate material for the expansion plug, and adding new components into the testing system, a modified expansion plug testing protocol has been developed. A general procedure was also developed to determine the hoop stress in the tested ring specimen. A scaling factor, -factor, was used to convert the ring load Fring into hoop stress , and is written as _ = F_ring/tl , where t is the clad thickness and l is the clad length. The generated stress-strain curve agrees well with the associated tensile test data in both elastic and plastic deformation regions.

expansion plug test↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2020 Status Report)

Leak testing experiments to monitor the aging performance of Viton GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. In addition, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 °F for 12 to 14 years or aging at 270 °F for 8.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 10 to 10.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analyzing the Validity of Brazilian Testing Using Digital Image Correlation and Numerical Simulation Techniques

Characterizing the mechanical behavior of rocks plays a crucial role to optimize the fracturing process in unconventional reservoirs. However, due to the intrinsic anisotropy and heterogeneity in unconventional resources, fracture process prediction remains the most significant challenge for sustainable and economic hydrocarbon production. During the deformation tracking under compression, deploying conventional methods (strain gauge, extensometer, etc.) is insufficient to measure the deformation since the physical attachment of the device is restricted to the size of the sample, monitoring limited point-wise deformation, producing difficulties in data retrieval, and a tendency to lose track in failure points, etc. Where conventional methods are limited, the application of digital image correlation (DIC) provides detailed and additional information of strain evolution and fracture patterns under loading. DIC is an image-based optical method that records an object with a camera and monitors the random contrast speckle pattern painted on the facing surface of the specimen. To overcome the existing limitations, this paper presents numerical modeling of Brazilian disc tests under quasi-static conditions to understand the full-field deformation behaviors and finally, it is validated by DIC. As the direct tensile test has limitations in sample preparation and test execution, the Brazilian testing principle is commonly used to evaluate indirectly the tensile strength of rocks. The two-dimensional numerical model was built to predict the stress distribution and full-field deformation on Brazilian disc under compression based on the assumptions of a homogenous, isotropic and linear elastic material. The uniaxial compression test was conducted using the DIC technique to determine the elastic properties of Spider Berea sandstone, which were used as inputs for the simulation model. The model was verified by the analytical solution and compared with the digital image correlation. The numerical simulation results showed that the solutions matched reasonably with the analytical solutions where the maximum deviation of stress distribution was obtained as 14.59%. The strain evolution (normal and shear strains) and displacements along the central horizontal and vertical planes were investigated in three distinguishable percentages of peak loads (20%, 40%, and 90%) to understand the deformation behaviors in rock. The simulation results demonstrated that the strain evolution contours consistently matched with DIC generated contours with a reasonable agreement. The changes in displacement along the central horizontal and vertical planes showed that numerical simulation and DIC generated experimental results were repeatable and matched closely. In terms of validation, Brazilian testing to measure the indirect tensile strength of rocks is still an issue of debate. The numerical model of fracture propagation supported by digital image correlation from this study can be used to explain the fracturing process in the homogeneous material and can be extended to non-homogeneous cases by incorporating heterogeneity, which is essential for rock mechanics field applications.

58 GEOSCIENCES↗

Unconfined Compression Results on Core from Borehole U-15n#10, NNSS, in support of SPE

The Nevada National Security Site (NNSS) serves as the geologic setting for a Source Physics Experiment (SPE) program. The SPE provides ground truth data to create and improve strong ground motion and seismic S-wave generation and propagation models. The NNSS was chosen as the test bed because it provides a variety of geologic settings ranging from relatively simple to very complex. Each series of SPE testing will comprise the setting and firing of explosive charges (source) placed in a central borehole at varying depths and recording ground motions in instrumented boreholes located in two rings around the source, positioned at different radii. Modeling using advanced simulation codes will be performed both before and after each test to predict ground response and to improve models based on acquired field data, respectively. A key component in the predictive capability and ultimate validation of the models is the full understanding of the intervening geology between the source and the instrumented boreholes including the geomechanical behavior of the site's rock/structural features. This memorandum reports on an initial phase of unconfined compression testing from corehole U-15n#10. Specimens tested came from the U-15n#10 core hole, which was drilled at -60° to the horizontal in granitic rock (quartz monzonite) after the second SPE shot (SPE-2). Figure 1 illustrates at the surface, the core hole was approximately 90 feet from the central SPE borehole. Corehole U 15n#10 intersects the central SPE borehole (U-15n) at a core depth of 170 feet (approximately 150 feet vertical depth) which is within the highly damaged zone of SPE-2. The U-15n#10 location is the site of the first, second and third SPE's, in Area 15 of the NNSS.

36 MATERIALS SCIENCE↗

Unconfined Compression Results on Core from Boreholes U-15n#12 and U-15n#13, NNSS in support of SPE

The Nevada National Security Site (NNSS) serves as the geologic setting for a Source Physics Experiment (SPE) program. The SPE provides ground truth data to create and improve strong ground motion and seismic S-wave generation and propagation models. The NNSS was chosen as the test bed because it provides a variety of geologic settings ranging from relatively simple to very complex. Each series of SPE testing will comprise the setting and firing of explosive charges (source) placed in a central borehole at varying depths and recording ground motions in instrumented boreholes located in two rings around the source, positioned at different radii. Modeling using advanced simulation codes will be performed both before and after each test to predict ground response and to improve models based on acquired field data, respectively. A key component in the predictive capability and ultimate validation of the models is the full understanding of the intervening geology between the source and the instrumented boreholes including the geomechanical behavior of the site's rock/structural features. This report summarizes unconfined compression testing (UCS) from coreholes U-15n#12 and U-15n#13 and compares those datasets to UCS results from coreholes U-15n and U-15n#10. U-15n#12 corehole was drilled at -60° to the horizontal and U-15n#13 was drilled vertically in granitic rock (quartz monzonite) after the third SPE shot. Figure 1 illustrates at the surface, U 15n#12 and U-15n#13 coreholes were approximately 30 meters and 10 meters from the central SPE borehole (U-15n) respectively. Corehole U-15n#12 intersects the central SPE borehole (U 15n) at a core depth of 174 feet (approximately 150 feet vertical depth). The location of U 15n#12 and U-15n#13 is the site of the first, second and third SPE's, in Area 15 of the NNSS.

58 GEOSCIENCES↗

Durability Testing of Biomass Based Oxygenated Fuel Components in a Compression Ignition Engine

Blending cellulosic biofuels with traditional petroleum-derived fuels results in transportation fuels with reduced carbon footprints. Many cellulosic fuels rely on processing methods that produce mixtures of oxygenates which must be upgraded before blending with traditional fuels. Complete oxygenate removal is energy-intensive and it is likely that such biofuel blends will necessarily contain some oxygen content to be economically viable. Previous work by our group indicated that diesel fuel blends with low levels (<4%-vol) of oxygenates resulted in minimal negative effects on short-term engine performance and emissions. However, little is known about the long-term effects of these compounds on engine durability issues such as the impact on fuel injection, in-cylinder carbon buildup, and engine oil degradation. In this study, four of the oxygenated components previously tested were blended at 4%-vol in diesel fuel and tested with a durability protocol devised for this work consisting of 200 hrs of testing in a stationary, single-cylinder, Yanmar diesel engine operating at constant load. Oil samples, injector spray patterns, and carbon buildup from the injector and cylinder surfaces were analyzed. It was found that, at the levels tested, these fuels had minimal impact on the overall engine operation, which is consistent with our previous findings.

09 BIOMASS FUELS↗

Durability Testing of Biomass Based Oxygenated Fuel Components in a Compression Ignition Engine

Blending cellulosic biofuels with traditional petroleum-derived fuels results in transportation fuels with reduced carbon footprints. Many cellulosic fuels rely on processing methods that produce mixtures of oxygenates which must be upgraded before blending with traditional fuels. Complete oxygenate removal is energy-intensive and it is likely that such biofuel blends will necessarily contain some oxygen content to be economically viable. Previous work by our group indicated that diesel fuel blends with low levels (<4%-vol) of oxygenates resulted in minimal negative effects on short-term engine performance and emissions. However, little is known about the long-term effects of these compounds on engine durability issues such as the impact on fuel injection, in-cylinder carbon buildup, and engine oil degradation. In this study, four of the oxygenated components previously tested were blended at 4%-vol in diesel fuel and tested with a durability protocol devised for this work consisting of 200 hrs of testing in a stationary, single-cylinder, Yanmar diesel engine operating at constant load. Oil samples, injector spray patterns, and carbon buildup from the injector and cylinder surfaces were analyzed. It was found that, at the levels tested, these fuels had minimal impact on the overall engine operation, which is consistent with our previous findings.

09 BIOMASS FUELS↗

Characterizing the Subsurface Using Deformation from Pumping and Surface Loading Tests

Changes in pore pressure or applied load cause deformation that can be used to characterize the subsurface. A series of field tests were conducted by measuring the deformation and pressure response from a variety of stresses at our test site in South Carolina. The site is underlain by saprolite to a depth of 30 m, and the water table in the unconfined aquifer occurs at a depth of 9 m. The types of tests performed included constant-rate pumping tests and surface point loading tests using the weight of a person or vehicle. Vertical displacement of the saprolite in response to these stresses was measured at depths of 3, 6, 9 and 11 meters in both saturated and unsaturated conditions using an extensometer with a resolution of +/- 10 nm. Results from 2.5-hr-long constant-rate pumping tests indicate a repeatable, compressive vertical strain of roughly 0.1 microstrain in the vadose zone and 1-10 microstrain in the saturated zone. Drawdown was 5 m in the pumping well and 0.1 m in a nearby (r = 9m) observation well. Under saturated conditions, the strain rate gradually decreased throughout the test in a pattern that resembles the drawdown curve in the monitoring well. In contrast, the strain in the vadose zone increased quickly early in the test, but the strain rate diminished and was negligible after approximately 30 minutes of pumping. Interestingly, drawdown in the pumping well also increased quickly over 30 minutes and remained roughly constant after that. Additional tests were conducted by applying a load (weight of a person or vehicle) at the ground surface above the extensometer and allowing the signal to stabilize before removing the load. In the vadose zone, the soil compressed rapidly and then stabilized. In the saturated zone, sudden compression was followed by additional compression at a much slower rate. A similar response was observed upon removal of the load. This transient signal in the saturated zone is interpreted to be a poroelastic effect. When a load is applied, the solid skeleton compresses and pressurizes the pore fluid, causing flow. The strain rate is then a function of pressure diffusion. Simulation of the deformation from both pumping and loading tests using an unsaturated, poroelastic finite-element model indicates that strains are sensitive to the Young’s modulus and hydraulic conductivity as functions of saturation.

well tests, strain, surface loading, hydromechanic↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

FY2025 Status Report: Model 9975 O Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aged at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aged at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months while fixture #18 failed after 9 months at 350 °F. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F. There has been one GLT O-ring fixture which failed after 13.4 years of aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 16.9 years and remain in test. There are two GLT O-ring fixtures at 270 °F; one fixture has failed after 12.9 years while the other fixture remains in test after 12.5 years. All GLT-S O-ring fixtures aged at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 14.9 years, while one GLT-S O-ring fixture failed after 12.4 years at 200 °F. The leak testing data to date suggest the GLT and GLT-S O-rings aging in the K-Area Complex (KAC) storage at temperatures of 158 °F might maintain a leak-tight seal for up to 59 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 24 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low thermal inertia thermal barrier coatings for spark ignition engines: An experimental study

Application of thermal barrier coatings in spark ignition engines have historically been avoided due to the knock penalty associated with higher surface temperatures induced by the ceramic layer. However, advances in low thermal inertia coatings (i.e. temperature swing coatings) that combine low thermal conductivity with low volumetric heat capacity can prevent excessively high surface temperatures during the intake stroke and reduce or avoid knock while improving performance and efficiency. In this study, a novel coating material was tested in a low compression ratio spark ignition engine to evaluate the performance of an advanced low thermal inertia coating during steady and cold-start conditions. A total of four pistons with this novel material was tested, with an additional piston coated with gadolinium zirconate. Spark timing sweeps demonstrated a maximum 0.8% relative thermal efficiency gain with a thin coating of the novel material. Here, the novel material coated above 200-microns showed a deterioration in performance and efficiency due to charge heating increasing knock propensity. Cold-start tests demonstrated that charge heating is beneficial for reducing unburned hydrocarbons and particle matter emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LX-17-1 Creep. Spring Load-up Study

We performed a study on billet pressed LX-17-1, Holston lot HOL87G51009, to examine the effect of adding a spring into the load train of our compression creep system. This effort was undertaken to see whether we could reduce test-to-test scatter by better controlling the load-up rate of our compressive creep tests.

42 ENGINEERING↗

Low-carbon fuels for spark-ignited engines: A comparative study of compressed natural gas and liquefied petroleum gas on a CFR engine with exhaust gas recirculation

Decades of work on low-carbon fuels have established their potential for substantial emissions reductions; however, their adoption is still limited by infrastructure concerns and engine efficiency deficits. As infrastructures have begun to evolve, research on strategies that maximize engine efficiency through interactions with fuel properties must also now take center place. This paper compares the performance, emissions, and combustion characteristics of two forefront low-carbon fuels: compressed natural gas (CNG) and liquefied petroleum gas (LPG) in a cooperative fuel research (CFR) engine over a range of compression ratios and engine loads. The effects of exhaust gas recirculation (EGR), end-gas auto-ignition, and a novel combustion control tool, the combustion intensity metric (CIM), were also evaluated at different stoichiometric engine operating conditions. In comparison to LPG, CNG operation demonstrated an extended knock-free regime, allowing engine operation at higher engine loads and compression ratios, but LPG operation exhibited enhanced combustion characteristics with higher peak pressures and faster apparent heat release rates (AHRR). LPG operation achieved higher brake thermal efficiencies and lower equivalent CO 2 emissions compared to CNG operation at the tested engine loads and compression ratios. LPG demonstrated significantly higher EGR tolerance limits compared to CNG, with a maximum of 28% EGR rate, compared to 23% for CNG. This improved EGR dilution tolerance was responsible for a 90% reduction in NOx emissions for LPG compared to a maximum of 70% with CNG. EGR dilution also exhibited more effective knock mitigation potential with LPG, suppressing knock intensity values by up to 98% and transitioning the engine operation towards normal combustion from heavy knocking conditions. As a result, the CIM was found to decrease burn durations and improve the quality of combustion by controlling the desired fraction of end-gas auto-ignition.

33 ADVANCED PROPULSION SYSTEMS↗

ESP - Data From Restarted Life Tests of Various Silicone Materials - 2009

Enhanced Surveillance Project (ESP) funding has allowed the restart of testing of various silicone materials placed in Life Tests or Aging Studies from past efforts. Some of these materials have been in test since 1982, with no testing for approximately 10 years, until ESP funding allowed the restart in FY97. This report will provide data on materials used on various programs and on experimental materials not used in production. Charts for the various materials at different thickness, compression, and temperature combinations illustrate trends for the load-bearing properties of the materials.

36 MATERIALS SCIENCE↗

Premixed ignition behavior of C{sub 9} fatty acid esters: A motored engine study

An experimental study on the premixed ignition behavior of C{sub 9} fatty acid esters has been conducted in a motored CFR engine. For each test fuel, the engine compression ratio was gradually increased from the lowest point (4.43) to the point where significant high temperature heat release (HTHR) was observed. The engine exhaust was sampled and analyzed through GC-FID/TCD and GC-MS. Combustion analysis showed that the four C{sub 9} fatty acid esters tested in this study exhibited evidently different ignition behavior. The magnitude of low temperature heat release (LTHR) follows the order, ethyl nonanoate > methyl nonanoate >> methyl 2-nonenoate > methyl 3-nonenoate. The lower oxidation reactivity for the unsaturated fatty acid esters in the low temperature regime can be explained by the reduced amount of six- or seven-membered transition state rings formed during the oxidation of the unsaturated esters due to the presence of a double bond in the aliphatic chain of the esters. The inhibition effect of the double bond on the low temperature oxidation reactivity of fatty acid esters becomes more pronounced as the double bond moves toward the central position of the aliphatic chain. GC-MS analysis of exhaust condensate collected under the engine conditions where only LTHR occurred showed that the alkyl chain of the saturated fatty acid esters participated in typical paraffin-like low temperature oxidation sequences. In contrast, for unsaturated fatty acid esters, the autoignition can undergo olefin ignition pathways. For all test compounds, the ester functional group remains largely intact during the early stage of oxidation. (author)

33 ADVANCED PROPULSION SYSTEMS↗