Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMMERCIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Corrosion of novel reactive silver ink and commercial silver-based metallizations in diluted acetic acid

Silver-based metallizations in photovoltaic modules are susceptible to corrosion by acetic acid generated in ethylene vinyl acetate encapsulated modules, resulting in power losses over time. Here, three silver-based metallizations are exposed to diluted acetic acid, in concentrations representative of that found in field-exposed modules. Compositional, morphological, and structural changes of the metallizations are studied over 3000 h of exposure to diluted acetic acid using Raman spectroscopy mapping, X-ray diffraction, and scanning electron microscopy. The three metallizations studied are: 1) a commercial high-temperature fire-through Ag paste, commonly used for Si diffused junction solar cells; 2) a commercial low-temperature paste normally used for silicon heterojunction cells; and 3) a novel low-temperature reactive silver ink shown to be suitable for photovoltaic applications. We find distinct corrosion rates for the high-temperature silver paste and reactive silver ink in the presence of diluted acetic acid. However, the low-temperature silver paste appears to be more corrosion resistant, likely due to a polymer layer that protects the silver particles.

36 MATERIALS SCIENCE↗

In-depth evaluation of commercially available human vascular smooth muscle cells phenotype: Implications for vascular tissue engineering

In vitro research on vascular tissue engineering has extensively used isolated primary human or animal smooth muscle cells (SMC). Research programs that lack such facilities tend towards commercially available primary cells sources. Here, we aim to evaluate the capacity of commercially available human SMC to maintain their contractile phenotype, and determine if dedifferentiation towards the synthetic phenotype occurs in response to conventional cell culture and passaging without any external biochemical or mechanical stimuli. Lower passage SMC adopted a contractile phenotype marked by a relatively slower proliferation rate, higher expression of proteins of the contractile apparatus and smoothelin, elongated morphology, and reduced deposition of collagen types I and III. As the passage number increased, migratory capacity was enhanced, average cell speed, total distance and net distance travelled increased up to passage 8. Through the various assays, corroborative evidence pinpoints SMC at passage 7 as the transition point between the contractile and synthetic phenotypes, while passage 8 distinctly and consistently exhibited characteristics of synthetic phenotype. This knowledge is particularly useful in selecting SMC of appropriate passage number for the target vascular tissue engineering application, for example, a homeostatic vascular graft for blood vessel replacement versus recreating atherosclerotic blood vessel model in vitro. - Highlights: • Ability of human smooth muscle cells to alter phenotype in culture is evaluated. • Examined the effect of passaging human smooth muscle cells on phenotype. • Phenotype is assessed based on morphology, proliferation, markers, and migration. • Multi-resolution assessment methodology, single-cell and cell-population. • Lower and higher passages than P7 adopted a contractile and synthetic phenotype respectively.

60 APPLIED LIFE SCIENCES↗

Characterization of Shallow, Undoped Ge/SiGe Quantum Wells Commercially Grown on 8-in. (100) Si Wafers

Hole spins in Ge quantum wells have shown success in both spintronic and quantum applications, thereby increasing the demand for high-quality material. We performed material analysis and device characterization of commercially grown shallow and undoped Ge/SiGe quantum well heterostructures on 8-in. (100) Si wafers. Material analysis reveals the high crystalline quality, sharp interfaces, and uniformity of the material. We demonstrate a high mobility (1.7 × 10 5 cm 2 V –1 s –1 ) 2D hole gas in a device with a conduction threshold density of 9.2 × 10 10 cm –2 . We study the use of surface preparation as a tool to control barrier thickness, density, mobility, and interface trap density. We report interface trap densities of 6 × 10 12 eV –1 . Our results validate the material’s high quality and show that further investigation into improving device performance is needed. We conclude that surface preparations which include weak Ge etchants, such as dilute H 2 O 2 , can be used for postgrowth control of quantum well depth in Ge-rich SiGe while still providing a relatively smooth oxide–semiconductor interface. Our results show that interface state density is mostly independent of our surface preparations, thereby implying that a Si cap layer is not necessary for device performance. Transport in our devices is instead limited by the quantum well depth. Commercially sourced Ge/SiGe, such as studied here, will provide accessibility for future investigations.

36 MATERIALS SCIENCE↗

Engineering Surface Oxygenated Functionalities on Commercial Carbon toward Ultrafast Sodium Storage in Ether-Based Electrolytes

The pursuit of a high-capacity anode material has been urgently required for commercializing sodium-ion batteries with a high energy density and an improved working safety. In the absence of thermodynamically stable sodium intercalated compounds with graphite, constructing nanostructures with expanded interlayer distances is still the mainstream option for developing high-performance carbonaceous anodes. In this regard, a surface-functionalized and pore-forming strategy through a facile CO 2 thermal etching route was rationally adopted to engineer negligible oxygenated functionalities on commercial carbon for boosting the sodium storage process. Benefitted from the abundant ionic/electronic pathways and more active reaction sites in the microporous structure with noticeable pseudocapacitive behaviors, the functionalized porous carbon could achieve a highly reversible capacity of 505 mA h g -1 at 50 mA g -1 , an excellent rate performance of 181 mA h g -1 at 16,000 mA g -1 , and an exceptional rate cycle stability of 176 mA h g -1 at 3200 mA g -1 over 1000 cycles. These outstanding electrochemical properties should be ascribed to a synergistic mechanism, fully utilizing the graphitic and amorphous structures for synchronous intercalations of sodium ions and solvated sodium ion compounds, respectively. Finally, the controllable generation and evolution of a robust but thin solid electrolyte interphase film with the emergence of obvious capacitive reactions on the defective surface, favoring the rapid migration of sodium ions and solvated species, also contribute to a remarkable electrochemical performance of this porous carbon black.

25 ENERGY STORAGE↗

Towards stable and commercially available perovskite solar cells

Solar cells employing a halide perovskite with an organic cation now show power conversion efficiency of up to 22%. But, these cells are facing issues towards commercialization, such as the need to achieve long-term stability and the development of a manufacturing method for the reproducible fabrication of high-performance devices. We propose a strategy to obtain stable and commercially viable perovskite solar cells. A reproducible manufacturing method is suggested, as well as routes to manage grain boundaries and interfacial charge transport. Electroluminescence is regarded as a metric to gauge theoretical efficiency. We highlight how optimizing the design of device architectures is important not only for achieving high efficiency but also for hysteresis-free and stable performance. Here, we argue that reliable device characterization is needed to ensure the advance of this technology towards practical applications. We believe that perovskite-based devices can be competitive with silicon solar modules, and discuss issues related to the safe management of toxic material.

14 SOLAR ENERGY↗

A non-precious metal hydrogen catalyst in a commercial polymer electrolyte membrane electrolyser

We demonstrate the translation of a low-cost, non-precious metal cobalt phosphide (CoP) catalyst from 1 cm 2 lab-scale experiments to a commercial-scale 86 cm 2 polymer electrolyte membrane (PEM) electrolyser. A two-step bulk synthesis was adopted to produce CoP on a high-surface-area carbon support that was readily integrated into an industrial PEM electrolyser fabrication process. The performance of the CoP was compared head to head with a platinum-based PEM under the same operating conditions (400 psi, 50 °C). CoP was found to be active and stable, operating at 1.86 A cm –2 for >1,700 h of continuous hydrogen production while providing substantial material cost savings relative to platinum. In conclusion, this work illustrates a potential pathway for non-precious hydrogen evolution catalysts developed in past decades to translate to commercial applications.

30 DIRECT ENERGY CONVERSION↗

A measured energy use, solar production, and building air leakage dataset for a zero energy commercial building

This paper provides an open dataset of measured energy use, solar energy production, and building air leakage data from a 328 m 2 (3,531 ft 2 ) all-electric, zero energy commercial building in Virginia, USA. Over two years of energy use data were collected at 1-hour intervals using circuit-level energy monitors. Over six years of solar energy production data were measured at 1-hour resolution by 56 microinverters (presented as daily and monthly data in this dataset). The building air leakage data was measured post-construction per ASTM-E779 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization and the United States Army Corps (USACE) Building Enclosure Testing procedure; both pressurization and depressurization results are provided. The architectural and engineering (AE) documents are provided to aid researchers and practitioners in reliable modeling of building performance. The paper describes the data collection methods, cleaning, and convergence with weather data. This dataset can be employed to predict, benchmark, and calibrate operational outcomes in zero energy commercial buildings.

14 SOLAR ENERGY↗

The Zap Energy approach to commercial fusion

Zap Energy is a private fusion energy company developing the sheared-flow-stabilized (SFS) Z-pinch concept for commercial energy production. Spun out from the University of Washington, these experimental and computational efforts have resulted in devices with quasi-steady DD fusion yields above 109 per pulse. These devices support scaling toward energy breakeven on existing devices as well as beyond to commercially relevant engineering fusion gains. This article discusses the strategy behind Zap's development path, which is derived directly from the engineering and scientific elegance of the confinement method. Without need for external confinement or heating technologies, the SFS Z pinch relies on plasma self-organization. This compact magnetic confinement technology could, in turn, provide the basis for a cost-effective fusion power plant, vastly reduced in complexity from its competitors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Initial TL/OSL/EPR considerations for commercial diatomaceous earth in retrospective dosimetry and dating

Diatomaceous earth is found in various locations around the planet. It is caused by the deposited exoskeleton material formed by the death of large concentrated populations of diatoms. The exoskeleton is effectively pure silicate and as such becomes a prospective material for retrospective dosimetry and dating. This work studied the thermoluminescence (TL) and optically stimulated luminescence properties of commercially obtained diatomaceous earth. The material was not found to have useful dosimetric properties with conventional TL methodologies but did provide large dose estimates using the Single Aliquot Regeneration technique on some subset samples. These results for organic silicate did imply some mechanisms explaining the sensitization process in geological silicate materials utilized in dosimetry and dating. Electron paramagnetic resonance was identified as a potential future method for evaluating this material as it revealed unique signal components not found in igneous or commercially produced silicates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AI ATAC 1: An Evaluation of Prominent Commercial Malware Detectors

This work presents an evaluation of six prominent commercial endpoint malware detectors, a network malware detector, and a file-conviction algorithm from a cyber technology vendor. The evaluation was administered as the first of the Artificial I ntelligence Applications t o Autonomous Cybersecurity (AI ATAC) prize challenges, funded by / completed in service of the US Navy. The experiment employed 100K files (50/50% benign/malicious) with a stratified distribution of file types, including ~1K zero-day program executables (increasing experiment size two orders of magnitude over previous work). We present an evaluation process of delivering a file to a fresh virtual machine donning the detection technology, waiting 90s to allow static detection, then executing the file and waiting another period for dynamic detection; this allows greater fidelity in the observational data than previous experiments, in particular, resource and time-to-detection statistics. To execute all 800K trials (100K files × 8 tools), a software framework is designed to choreograph the experiment into an automated, time-synced, and reproducible workflow with substantial parallelization. Software with base classes for this framework are provided. A cost-benefit model was configured to integrate the tools’ detection statistics into a comparable quantity by simulating costs of use. This provides a ranking methodology for cyber competitions and a lens for reasoning about the varied statistical results. The results provide insights on state of commercial malware detection.

Bridges, Robert↗

Distributed Flexibility Characterization and Resource Allocation Strategies for Multi-zone Commercial Buildings in the Smart Grid

The HVAC (Heating, Ventilation, and Air- Conditioning) system of commercial buildings is a complex system with a large number of dynamically interacting components. In particular, the thermal dynamics of each zone are coupled with those of the neighboring zones. In this paper, we study a multi-agent based approach to model and control commercial building HVAC system for providing grid services. In the multi-agent system (MAS), individual zones are modeled as agents that can communicate, interact, and negotiate with one another to achieve a common objective. We first propose a distributed characterization method on the aggregated airflow (and thus fan power) flexibility that the HVAC system can provide to the ancillary service market. Then, we propose a Nash-bargaining based airflow allocation strategy to track a dispatch signal (that is within the offered flexibility limit) while respecting the preference and flexibility of individual zones. Moreover, we devise a distributed algorithm to obtain the Nash bargaining solution via dual decomposition and average consensus. Numerical simulations illustrate that the proposed distributed protocols are much more scalable than the centralized approaches especially when the system becomes larger and more complex.

Hao, He↗

Probabilistic Power Consumption Modeling for Commercial Buildings Using Logistic Regression Markov Chain

The total energy consumed by buildings takes up to 40% of U.S. energy use, in which a large portion is contributed by commercial buildings. Building performance optimization is desirable but requires accurate building models with uncertainties taken into account. This paper proposes a novel probabilistic modeling method using Logistic Regression Markov Chain (LRMC). The LRMC model enhances the performance of traditional Markov Chain (MC) models by adopting time-variant transition matrices calibrated using logistic regression with exogenous inputs. Compared with existing building models, the proposed model produces accurate multi-step modeling results with full probability distribution. The proposed probabilistic building model is tested using actual commercial building measurements and modeling performance is evaluated with two probabilisitc metrics. The results show that the LRMC model has higher accuracy than traditional MC model and Logistic Regression (LR) model in that it yields lower error scores under both evaluation metrics.

Building modeling↗

Comparison of MPC Formulations for Building Control under Commercial Time-of-Use Tariffs

© 2019 IEEE. Most medium and large commercial buildings in the U.S. are subject to complex electricity tariffs that combine both Time-of-Use (TOU) energy and demand charges. This study analyses the performances of different economic Model Predictive Control (MPC) formulations, from the standpoints of monthly bill reduction, load shifting, and peak demand reduction. Simulations are performed on many simplified commercial building models, with multiple TOU demand charges, and under various summer conditions. Results show that compared to energy-only MPC, the traditional method for dealing with demand charges significantly reduces peak demand and owner bill, however, highlight a lack of load shifting capability. A proposed incremental approach is presented, which better balances the bill components in the objective function. In the case study presented, this method can improve monthly bill savings and increase load shifting during demand response events, while keeping a similarly low peak demand, compared to traditional MPC methods taking into account demand charges.

Cutsem, Olivier Van↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

A Comparison of Ion Implantation at Room Temperature and Heated Ion Implantation on the Body Diode Degradation of Commercial 3.3 kV 4H-SiC Power MOSFETs

It has been demonstrated that basal plane dislocations (BPDs)-induced stacking faults (SFs) cause body diode degradation in commercial 4H-SiC power MOSFETs, especially with higher voltage ratings. BPDs originate from 4H-SiC boule, epi growth, and ion implantation. Considering the lower cost of ion implantation at room temperature (RT), this work investigates the potential of RT ion implantation replacing heated (HT) ion implantation by comparing the influence of both ion implantations on the body diode degradation of commercial 3.3 kV 4H-SiC power MOSFETs. We demonstrate with long-term (up to 1000 hours) forward current stress that RT implantation can keep the body diode degradation of 3.3 kV 4H-SiC power MOSFETs within the specification limits compared with HT implantation.

4H-SiC↗

Generation of a highly attenuated strain of Pseudomonas aeruginosa for commercial production of alginate

Alginate is an important polysaccharide that is commonly used as a gelling agent in foods, cosmetics and healthcare products. Currently, all alginate used commercially is extracted from brown seaweed. However, with environmental changes such as increasing ocean temperature and the increasing number of biotechnological uses of alginates with specific properties, there is an emerging need for more reliable and customizable sources of alginate. An alternative to seaweed for alginate production is Pseudomonas aeruginosa, a common Gram-negative bacterium that can form alginate containing biofilms. However, P. aeruginosa is an opportunistic pathogen that can cause life-threatening infections in immunocompromised patients. Therefore, we sought to engineer a non-pathogenic P. aeruginosa strain that is safe for commercial production of alginate. Using a homologous recombination strategy, we sequentially deleted five key pathogenicity genes from the P. aeruginosa chromosome, resulting in the marker-free strain PGN5. Intraperitoneal injection of mice with PGN5 resulted in 0% mortality, while injection with wild-type P. aeruginosa resulted in 95% mortality, providing evidence that the systemic virulence of PGN5 is highly attenuated. Importantly, PGN5 produces large amounts of alginate in response to overexpression of MucE, an activator of alginate biosynthesis. The alginate produced by PGN5 is structurally identical to alginate produced by wildtype P. aeruginosa, indicating that the alginate biosynthetic pathway remains functional in this modified strain. The genetic versatility of P. aeruginosa will allow us to further engineer PGN5 to produce alginates with specific chemical compositions and physical properties to meet different industrial and biomedical needs.

60 APPLIED LIFE SCIENCES↗