Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Association Between Dispatch Complaint and Critical Prehospital Time Intervals in Suspected Stroke 911 Activations in the National Emergency Medical Services Information System, 2012–2016

Emergency Medical Services can help improve stroke outcomes by recognizing stroke symptoms, establishing response priority for 911 calls, and minimizing prehospital delays. This study examines 911 stroke events and evaluates associations between events dispatched as stroke and critical EMS time intervals. Data from the National Emergency Medical Services Information System, 2012 to 2016, were analyzed. Activations from 911 calls with a primary or secondary provider impression of stroke were included for adult patients transported to a hospital destination. Three prehospital time intervals were evaluated: (1) response time (RT) ≤8 min, (2) on-scene time (OST) ≤15 min, and (3) transport time (TT) ≤12 min. Associations between stroke dispatch complaint and prehospital time intervals were assessed using multivariate regression to estimate adjusted risk ratios (ARR) and 95% confidence intervals (CIs). Approximately 37% of stroke dispatch complaints were identified by EMS as a suspected stroke. Compared to stroke events without a stroke dispatch complaint, median OST was shorter for events with a stroke dispatch (16 min vs. 14 min, respectively). In adjusted analyses, events dispatched as stroke were more likely to meet the EMS time benchmark for OST ≤15 min (OST, 1.20 [1.20–1.21]), but not RT or TT (RT, [1.00–1.01]; TT, 0.95 [0.94–0.95]). Furthermore, our results indicate that dispatcher recognition of stroke symptoms reduces the time spent on-scene by EMS personnel. These findings can inform future EMS stroke education and quality improvement efforts to emphasize dispatcher recognition of stroke signs and symptoms, as EMS dispatchers play a crucial role in optimizing the prehospital response.

59 BASIC BIOLOGICAL SCIENCES↗

The three dimensional X-ray diffraction technique

This introductory tutorial describes the so called 3 dimensional X-ray diffraction (3DXRD) technique, which allows bulk non-destructive structural characterizations of crystalline materials. The motivations and history behind the development of this technique are described and its potentials are sketched. Examples of the use of the technique are given and future trends and developments are suggested. The primary aim of the paper is to give 3DXRD novices an easy introduction to the technique and to describe a way from a dream to reality and new results.

36 MATERIALS SCIENCE↗

Benefits of utilizing CellProfiler as a characterization tool for U–10Mo nuclear fuel

Automated image processing techniques have the potential to aid in the performance evaluation of nuclear fuels by eliminating judgment calls that may vary from person-to-person or sample-to-sample. Analysis of in-core fuel performance is required for design and safety evaluations related to almost every aspect of the nuclear fuel cycle. This study presents a methodology for assessing the quality of uranium–molybdenum fuel images and describes image analysis routines designed for the characterization of several important microstructural properties. The analyses are performed in CellProfiler, an open-source program designed to enable biologists without training in computer vision or programming to automatically extract cellular measurements from large image sets. The quality metric scores an image based on three parameters: the illumination gradient across the image, the overall focus of the image, and the fraction of the image that contains scratches. The metric presents the user with the ability to ‘pass’ or ‘fail’ an image based on a reproducible quality score. Passable images may then be characterized through a separate CellProfiler pipeline, which enlists a variety of common image analysis techniques. The results demonstrate the ability to reliably pass or fail images based on the illumination, focus, and scratch fraction of the image, followed by automatic extraction of morphological data with respect to fission gas voids, interaction layers, and grain boundaries. - Graphical abstract: Display Omitted - Highlights: • A technique is developed to score U–10Mo FIB-SEM image quality using CellProfiler. • The pass/fail metric is based on image illumination, focus, and area scratched. • Automated image analysis is performed in pipeline fashion to characterize images. • Fission gas void, interaction layer, and grain boundary coverage data is extracted. • Preliminary characterization results demonstrate consistency of the algorithm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterizing the nano-structure and defect structure of nano-scaled non-ferrous structural alloys

The presence and interaction of nanotwins, geometrically necessary dislocations, and grain boundaries play a key role in the mechanical properties of nanostructured crystalline materials. Therefore, it is vital to determine the orientation, width and distance of nanotwins, the angle and axis of grain boundary misorientations as well as the type and the distributions of dislocations in an automatic and statistically meaningful fashion in a relatively large area. In this paper, such details are provided using a transmission electron microscope-based orientation microscopy technique called ASTAR™/precession electron diffraction. The remarkable spatial resolution of this technique (~ 2 nm) enables highly detailed characterization of nanotwins, grain boundaries and the configuration of dislocations. This orientation microscopy technique provides the raw data required for the determination of these parameters. The procedures to post-process the ASTAR™/PED datasets in order to obtain the important (and currently largely hidden) details of nanotwins as well as quantifications of dislocation density distributions are described in this study. - Highlights: • EBSD cannot characterize defects such as dislocations, grain boundaries and nanotwins in severely deformed metals. • TEM based orientation microscopy technique called ASTAR™/PED was used to resolve the problem. • Locations and orientations of nanotwins, dislocation density distribution and grain boundary characters can be resolved. • This work provides the bases for further studies on the interactions between dislocations, grain boundaries and nanotwins. • The computation part is explained sufficiently which helps the readers to post process their own data.

36 MATERIALS SCIENCE↗

Unit cell dilation technique for analyzing dilatometry data in microalloyed steels

Highlights: • Lever rule is not an adequate method to analyze dilatometry data. • A method called “Unit Cell Dilation” is developed to analyze the dilatometry data. • The new method calculates phase fractions while accounting for chemical changes during diffusive phase transformation. - Abstract: Dilatometry is the most accurate and common method for measuring the kinetics of phase transformations in solid specimens. Despite the development of a more accurate technique, an inferior method, i.e., the lever rule, is widely used in the scientific community to interpret raw dilatometry data. This paper introduces a sound mathematical approach to modeling the physical phenomena of phase transformations, named continuous sequential phase transformation (CSPT). CSPT is used in creating an algorithm called unit cell dilation (UCD) that is used for analyzing the continuous phase transformation of two microalloyed steels. Results show that the UCD algorithm generates quantitative data for the phase content of the steel that is in good agreement with metallographic observations. The source code for an implementation of the UCD algorithm is distributed under GPL-3.0 license and available for download at (https://github.com/Nassehk/Dilatometry-analysis.git).

36 MATERIALS SCIENCE↗

A novel approach for adaptive skeleton toolpath generation

Industry 4.0 is revolutionizing manufacturing through the integration of automation and real-time data sharing in cyber-physical systems. At the forefront of this revolution is large-format additive manufacturing. In large-format printing, parts are often designed to be an even number of beads wide to produce a completely dense part. However, voids can still arise. This is often due to the part not being an even number of bead widths wide in some areas, or in geometry containing acute angles, as the process of generating closed contours cannot completely fill the space. Voids can be tolerated in smaller models, but in large-format additive manufacturing they may cause mechanical defects. To fill these voids, open loop paths called skeletons are often used, but they are typically limited by the physical constraints defined in the slicing software. To address this, researchers at Oak Ridge National Laboratory have extended skeleton toolpaths via an adaptive methodology. These adaptive skeletons were found to better fill void spaces through manipulation of physical parameters of the build process and were calculated as part of the slicing process.

42 ENGINEERING↗

The Need for Precise and Well-documented Experimental Data on Prompt Fission Neutron Spectra from Neutron-induced Fission of {sup 239}Pu

The spectrum of neutrons emitted promptly after {sup 239}Pu(n,f)—a so-called prompt fission neutron spectrum (PFNS)—is a quantity of high interest, for instance, for reactor physics and global security. However, there are only few experimental data sets available that are suitable for evaluations. In addition, some of those data sets differ by more than their 1-σ uncertainty boundaries. We present the results of MCNP studies indicating that these differences are partly caused by underestimated multiple scattering contributions, over-corrected background, and inconsistent deconvolution methods. A detailed uncertainty quantification for suitable experimental data was undertaken including these effects, and test-evaluations were performed with the improved uncertainty information. The test-evaluations illustrate that the inadequately estimated effects and detailed uncertainty quantification have an impact on the evaluated PFNS and associated uncertainties as well as the neutron multiplicity of selected critical assemblies. A summary of data and documentation needs to improve the quality of the experimental database is provided based on the results of simulations and test-evaluations. Given the possibly substantial distortion of the PFNS by multiple scattering and background effects, special care should be taken to reduce these effects in future measurements, e.g., by measuring the {sup 239}Pu PFNS as a ratio to either the {sup 235}U or {sup 252}Cf PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of the Neutron Data Standards

With the need for improving existing nuclear data evaluations, (e.g., ENDF/B-VIII.0 and JEFF-3.3 releases) the first step was to evaluate the standards for use in such a library. This new standards evaluation made use of improved experimental data and some developments in the methodology of analysis and evaluation. In addition to the work on the traditional standards, this work produced the extension of some energy ranges and includes new reactions that are called reference cross sections. Since the effort extends beyond the traditional standards, it is called the neutron data standards evaluation. This international effort has produced new evaluations of the following cross section standards: the H(n,n), 6 Li(n,t), 10 B(n,α), 10 B(n,α 1 γ), nat C(n,n), Au(n,γ), 235 U(n,f) and 238 U(n,f). Also in the evaluation process the 238 U(n,γ) and 239 Pu(n,f) cross sections that are not standards were evaluated. Evaluations were also obtained for data that are not traditional standards: the Maxwellian spectrum averaged cross section for the Au(n,γ) cross section at 30 keV; reference cross sections for prompt γ-ray production in fast neutron-induced reactions; reference cross sections for very high energy fission cross sections; the 252 Cf spontaneous fission neutron spectrum and the 235 U prompt fission neutron spectrum induced by thermal incident neutrons; and the thermal neutron constants. The data and covariance matrices of the uncertainties were obtained directly from the evaluation procedure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fourier method for 3-dimensional data fusion of X-ray Computed Tomography and ultrasound

X-ray Computed Tomography (CT) is essential for nondestructive inspection of many manufactured components but is susceptible to various forms of artifacts and noise. In particular, multi-detector row cone-beam CT systems can suffer from so called “cone-beam” artifacts and partial volume effects, particularly on planar edges at the periphery of the field of view in the cone angle dimension. Uni-directional ultrasonic testing methods generally have extremely accurate in-plane depth resolution but poorer lateral resolution due to physical and geometric constraints. This paper presents a novel technique called Computed Tomographic Fusion (CT-F) which uses three-dimensional Fourier filtering to combine x-ray cone-beam CT reconstructions and ultrasound data in the frequency space. The result is a single image with improved accuracy and quality. CT-F mitigates artifacts while allowing for rapid, accurate characterization of large three-dimensional CT volumes. Finally, using simulations and experiments, we demonstrate artifact reduction and edge contrast improvement in volumetric reconstructions.

42 ENGINEERING↗

On the equivalence of the RTI and SVM approaches to time correlated analysis

Recently two papers on how to perform passive neutron auto-correlation analysis on time gated histograms formed from pulse train data, generically called time correlation analysis (TCA), have appeared in this journal [1,2]. For those of us working in international nuclear safeguards these treatments are of particular interest because passive neutron multiplicity counting is a widely deployed technique for the quantification of plutonium. The purpose of this letter is to show that the skewness-variance-mean (SVM) approach developed in [1] is equivalent in terms of assay capability to the random trigger interval (RTI) analysis laid out in [2]. Mathematically we could also use other numerical ways to extract the time correlated information from the histogram data including for example what we might call the mean, mean square, and mean cube approach. The important feature however, from the perspective of real world applications, is that the correlated information extracted is the same, and subsequently gets interpreted in the same way based on the same underlying physics model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of the beam extraction synchronization system at the Fermilab Booster

The new beam extraction synchronization control system called “Magnetic Cogging” was developed at the Fermilab Booster and it replaces a system called “RF Cogging” as part of the Proton Improvement Plan (PIP). [1] The flux throughput goal for the PIP is 2.2×10 17 protons per hour, which is double the present flux. Thus, the flux increase will be accomplished by doubling the number of beam cycles which, in turn, will double the beam loss in the Booster accelerator if nothing else is done.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing layers, 4- and 5-dimension tracking

The combination of precision space and time information in particle tracking, the so called 4D tracking, is being considered in the upgrade of the ATLAS, CMS and LHCb experiments at the High-Luminosity LHC, set to start data taking in 2024–2025. Regardless of the type of solution chosen, space–time tracking brings benefits to the performance of the detectors by reducing the background and sharpening the resolution; it improves tracking performances and simplifies tracks combinatorics. Space–time tracking also allows investigating new physics channels, for example it opens up the possibilities of new searches in long-living particles by measuring accurately the time of flight between the production and the decay vertexes. The foreseen applications of 4D tracking in experiments with very high acquisition rates, for example at HL-LHC, add one more dimension to the problem, increasing dramatically the complexity of the read-out system and that of the whole detector design: we call 5D tracking the application of 4D tracking in high rate environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of prototype GE1/1 chambers for the CMS muon spectrometer upgrade

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions during HL-LHC, the Compact Muon Solenoid (CMS) Collaboration will use Gas Electron Multiplier (GEM) detector technology. The technology will be integrated into the innermost region of the forward muon spectrometer of CMS as an additional muon station called GE1/1. The primary purpose of this auxiliary station is to help in muon reconstruction and to control level-1 muon trigger rates in the pseudo-rapidity region 1.6 ≤ |η| ≤ 2.2. The new station will contain trapezoidal-shaped GEM detectors called GE1/1 chambers. The design of these chambers is finalized, and the installation is in progress during the Long Shutdown phase two (LS-2) that started in 2019. Several full-size prototypes were built and operated successfully in various test beams at CERN. Here, we describe performance measurements such as gain, efficiency, and time resolution of these prototype chambers, developed after years of R&D, and summarize their behavior in different gas compositions as a function of the applied voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the High Rigidity Spectrometer at FRIB

A High Rigidity Spectrometer (HRS) has been designed for experiments at the Facility for Rare-Isotope Beams (FRIB) at Michigan State University (MSU). The HRS will allow experiments to be performed with the most exotic neutron-rich isotopes at high beam energies (≳100 MeV/u). The HRS consists of an analysis beamline called the High-Transmission Beamline (HTBL) and the spectrometer proper called the Spectrometer Section. Here, the maximum magnetic rigidity of the HRS is 8 Tm, which corresponds to the rigidities at which rare-isotope beams are optimally produced at FRIB. The resolving power, angular acceptance, and momentum acceptance are set to match the anticipated scientific program. An ion-optical design developed for the HRS is described in detail, along with the specifications of the associated magnet and detector systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fabrication and Design Aspects of High-Temperature Compact Diffusion Bonded Heat Exchangers

The Very High Temperature Reactor (VHTR) using gas-cooled reactor technology is anticipated to be the reactor type for the Next Generation Nuclear Plant (NGNP). In this reactor concept with an indirect power cycle system, a high-temperature and high integrity Intermediate Heat Exchanger (IHX) with high effectiveness is required to efficiently transfer the core thermal output to a secondary fluid for electricity generation, hydrogen production, and/or industrial process heat applications. At present, there is no proven IHX concept for VHTRs. The current Technology Readiness Level (TRL) status issued by NGNP to all components associated with the IHX for reduced nominal reactor outlet temperatures of 750–800 degrees C is 3 on a 1–10 scale, with 10 indicating omplete technological maturity. Among the various potential IHX concepts available, diffusion bonded heat exchangers (henceforth called printed circuit heat exchangers, or PCHEs) appear promising for NGNP applications. The design and fabrication of this key component of NGNP with Alloy 617, a candidate high-temperature structural material for NGNP applications, are the primary focus of this paper. In the current study, diffusion bonding of Alloy 617 has been demonstrated, although the optimum diffusion bonding process parameters to engineer a quasi interface-free joint are yet to be determined. The PCHE fabrication related processes, i.e., photochemical etching and diffusion bonding are discussed for Alloy 617 plates. In addition, the authors’ experiences with these non-conventional machining and joining techniques are discussed. Two PCHEs are fabricated using Alloy 617 plates and are being experimentally investigated for their thermal-hydraulic performance in a High-Temperature Helium Facility (HTHF). The HTHF is primarily of Alloy 800H construction and is designed to facilitate experiments at temperatures and pressures up to 800 degrees C and 3 MPa, respectively. Furthermore, some preliminary microstructural and mechanical property characterization studies of representative diffusion bonded Alloy 617 specimens are presented. The characterization studies are restricted and less severe from an NGNP perspective but provide sufficient confidence to ensure safe operation of the heat exchangers in the HTHF. The test results are used to determine the design operating conditions for the PCHEs fabricated.

99 GENERAL AND MISCELLANEOUS↗

Spectral Element Applications in Complex Nuclear Reactor Geometries: Tet-to-Hex Meshing

The spectral element code Nek5000 is an open-source, higher-order computational fluid dynamics code developed at Argonne National Laboratory. It is designed to solve incompressible Navier-Stokes equations, but it also has a low-Mach-number approximation feature available. Large eddy simulation is approached by explicit filtering of the velocity field (and other fields) to mimic the effect of dissipation due to the unresolved scale. The computational domain is decomposed into second-order hexahedral elements that conform to the boundaries. However, generating a high-quality pure-hexahedral mesh can be challenging for some problems. For simple geometries, traditional blocking methods can be used to decompose the domain into smaller blocks to generate a so-called structural mesh. A structural mesh can maintain good orthogonality but can have a highly skewed mesh to conform to the geometry, as well as unnecessary refinement in the far field. Moreover, for geometries with relative complexity, blocking the geometry becomes impossible. To address these issues, we adopted a let-to-hex strategy to generate a pure hexahedral mesh for Nek5000. First, we generate a pure tetrahedral mesh for the geometry; then we divide one tetrahedral element into four hexahedral elements. A pure tetrahedral mesh could be easily generated for complex geometries by using many current meshing codes. In this paper, we use the commercial codes ANSYS meshing and ANSYSICEM to generate the pure tetrahedral mesh and then convert it to a pure hexahedral mesh. Boundary layers are extruded in ANSYSICEM to maintain near-wall resolution.

ANSYS ICEM↗

Collimated phase measuring deflectometry

Phase measuring deflectometry has been applied for free-form specular surface metrology, but its measured slope results are sensitive to the depth of sample positioning, which is also called the height-slope ambiguity. The objective of this work is to tackle this height-slope ambiguity problem. The main idea is to introduce collimated camera rays using a telecentric imaging lens and collimated structured-light illumination with a Fourier lens. This setup makes the fringe phases become only sensitive to the surface slopes and insensitive to the depth of the sample positioning. In this way, the slope calculation is theoretically independent of the sample depth. We call this new deflectometry technique Collimated Phase Measuring Deflectometry (CPMD). With our developed CPMD experimental setup, the measurement is insensitive to the depth of sample positioning, e.g., the measured height dispersion is less than 30 nm RMS within a 10 mm depth range when measuring a 50-mm-diameter spherical mirror with a 200 mm radius of curvature. In conclusion, the merits and limitations of the proposed CPMD technique are discussed, revealing its prospects in practical metrology applications and potential future investigations.

36 MATERIALS SCIENCE↗