Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Full calibration of the tomographic redshift distribution from the HSC PDR3 Shape Catalog with DESI

The calibration of tomographic redshift distributionsis essential for cosmological analysis of weak lensing data.In this work, we calibrate all four tomographic bins of the Hyper Suprime Camera (HSC) weak lensing catalog with the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 and 2 using the clustering redshifts technique. We include z > 1.2 redshift sources such as emission line galaxies (ELG) and quasars (QSO) sources in our calibration, which were not available in the previous HSC calibration (Rau et al. (2022), Mon. Not. Roy. Astron. Soc. 524 (2023) 5109), allowing a complete calibration of all the redshift bins. We find the first tomographic bin exhibits a small shift towards low redshifts. The second bin is in good agreement with the photometric calibration, while third and fourth bin exhibit a shift towards higher redshifts. However, these shifts are considerably smaller than the shifts obtained in the HSC Year 3 cosmic shear analyses. We evaluate the impact of galaxy bias and magnification effects from all the samples on the measurements, finding them to be small, and we propose corrections to reduce them further. Specifically, we relax the assumption of linear bias and only assume no redshift evolution of the cross-correlation coefficient, allowing us to leverage smaller clustering scales. We model the redshift distributions with splines and compare our results to previous analyses as well as to other parameterizations found in literature. For the two high-redshift tomographic bins, we find the shifts to higher redshifts with respect to the measurements performed in Rau+2022 to be Δz$_{3}$ =-0.039$^{+0.020}$$_{-0.021}$ and Δz$_{4}$ = -0.048$^{+0.012}$$_{-0.012}$.

Choppin de Janvry, J. [LBL, Berkeley; UC, Berkeley↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics

High-accuracy surface metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate x-ray light with nanometer-scale wavelengths. The current and potential capabilities of x˗ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. Metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for fabrication of slightly curved x-ray optics. However, for even moderately curved aspherical x-ray mirrors the flat-reference calibration is not sufficiently accurate. For micro-stitching interferometry developed for surface measurements with curved x-ray mirrors, the tool aberration errors are known to be transferred into the optical surface topography of x-ray mirrors. Our approach to improving metrology is to thoroughly calibrate the measuring tool and apply the results of the calibration to deconvolution of the measured data. Here we explore the application of a recently developed technique for calibrating the instrument transfer function (ITF) of 3D optical surface profilers to metrology with significantly curved x-ray optics. The technique, based on test standards patterned with two-dimensional (2D) binary pseudo-random arrays (BPRAs), employs the unique properties of the BPRA patterns in the spatial frequency domain. The inherent 2D power spectral density of the pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field of view of an instrument. The high efficacy of the technique has been previously demonstrated in application to metrology with flat and slightly curved optics. Here, we concentrate on development of an efficient fabrication process for production of highly randomized (HR) BPRA test standards on flat and 500-mm spherical optical substrates. We also compare and discuss the results of the ITF calibration of an interferometric microscope when using the HR BPRA standards on flat and curved substrates.

Munechika, Keiko↗

A Theoretical Framework for Calibration in Computer Models: Parametrization, Estimation and Convergence Properties

Calibration parameters in deterministic computer experiments are those attributes that cannot be measured or available in physical experiments. Here, an approach to estimate them by using data from physical experiments and computer simulations. A theoretical framework is given which allows us to study the issues of parameter identifiability and estimation. We define the L 2 -consistency for calibration as a justification for calibration methods. It is shown that a simplified version of the original KO method leads to asymptotically L 2 -inconsistent calibration. This L 2 -inconsistency can be remedied by modifying the original estimation procedure. A novel calibration method, called the L 2 calibration, is proposed and proven to be L 2 -consistent and enjoys optimal convergence rate. Furthermore a numerical example and some mathematical analysis are used to illustrate the source of the L 2 -inconsistency problem.

97 MATHEMATICS AND COMPUTING↗

Determination of jet calibration and energy resolution in proton–proton collisions at $\sqrt{s} = 8~\hbox {TeV}$ using the ATLAS detector

The jet energy scale, jet energy resolution, and their systematic uncertainties are measured for jets reconstructed with the ATLAS detector in 2012 using proton–proton data produced at a centre-of-mass energy of 8 TeV with an integrated luminosity of 20fb -1 . Jets are reconstructed from clusters of energy depositions in the ATLAS calorimeters using the anti-k t algorithm. A jet calibration scheme is applied in multiple steps, each addressing specific effects including mitigation of contributions from additional proton–proton collisions, loss of energy in dead material, calorimeter non-compensation, angular biases and other global jet effects. The final calibration step uses several in situ techniques and corrects for residual effects not captured by the initial calibration. Furthermore, these analyses measure both the jet energy scale and resolution by exploiting the transverse momentum balance in γ + jet, Z + jet, dijet, and multijet events. A statistical combination of these measurements is performed. In the central detector region, the derived calibration has a precision better than 1% for jets with transverse momentum 150 GeV < p T < 1500 GeV, and the relative energy resolution is (8.4 ± 0.6)% for p T =100 GeV and (23 ± 2)% for p T =20 GeV. The calibration scheme for jets with radius parameter R = 1.0, for which jets receive a dedicated calibration of the jet mass, is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New techniques for jet calibration with the ATLAS detector

A determination of the jet energy scale is presented using proton–proton collision data with a centre-of-mass energy of $\sqrt{s}$ = 13 TeV, corresponding to an integrated luminosity of 140 fb -1 collected using the ATLAS detector at the LHC. Jets are reconstructed using the ATLAS particle-flow method that combines charged-particle tracks and topo-clusters formed from energy deposits in the calorimeter cells. The anti-k t jet algorithm with radius parameter R = 0.4 is used to define the jet. Novel jet energy scale calibration strategies developed for the LHC Run 2 are reported that lay the foundation for the jet calibration in Run 3. Jets are calibrated with a series of simulation-based corrections, including state-of-the-art techniques in jet calibration such as machine learning methods and novel in situ calibrations to achieve better performance than the baseline calibration derived using up to 81 fb -1 of Run 2 data. The performance of these new techniques is then examined in the in situ measurements by exploiting the transverse momentum balance between a jet and a reference object. The b -quark jet energy scale using particle flow jets is measured for the first time with around 1% precision using $\gamma$+jet events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a simplified calibrated building simulation model of a supermarket for proposed ECMs and control strategies impact evaluation

Calibrated building energy simulation is an important pathway to more energy-efficient buildings, but the information requirements of some approaches to this problem are significant. This is particularly true for supermarkets and other so-called “big-box” retail stores. Another characteristic of supermarkets is the significant interaction between Heating Ventilating and Air Conditioning (HVAC) and refrigeration systems in these buildings. These buildings could contain a wide variety of systems and a degree of load diversity that makes calibrated modeling a challenge. This paper describes a simplified approach that uses OpenStudio and EnergyPlus to combine known building parameters with “typical” parameters, resulting in a simplified building that is amenable to calibration. This approach was applied to a big-box store located in Nashville, Tennessee, and a calibrated model was obtained that was used to study potential energy conservation measures. Further, the paper also explores the capabilities of whole-building energy modeling tools, such as EnergyPlus, for modeling the HVAC controls and sequences and their impact evaluation. Although some measures are precluded by the model simplicity, several measures were found to improve the efficiency of the model and demonstrate that the simplified modeling approach is effective. Practical Application: This paper introduces a hybrid approach of building energy model calibration using limited information available from the actual building in combination with characteristics of a “typical” building of the same type. This hybrid approach would also be applicable for other building types than discussed in this paper to calibrate the building energy model using limited information from the actual building.

42 ENGINEERING↗

Volumetric calibration of a plenoptic camera

Here, the volumetric calibration of a plenoptic camera is explored to correct for inaccuracies due to real-world lens distortions and thin-lens assumptions in current processing methods. Two methods of volumetric calibration based on a polynomial mapping function that does not require knowledge of specific lens parameters are presented and compared to a calibration based on thin-lens assumptions. The first method, volumetric dewarping, is executed by creation of a volumetric representation of a scene using the thin-lens assumptions, which is then corrected in post-processing using a polynomial mapping function. The second method, direct light-field calibration, uses the polynomial mapping in creation of the initial volumetric representation to relate locations in object space directly to image sensor locations. The accuracy and feasibility of these methods is examined experimentally by capturing images of a known dot card at a variety of depths. Results suggest that use of a 3D polynomial mapping function provides a significant increase in reconstruction accuracy and that the achievable accuracy is similar using either polynomial-mapping-based method. Additionally, direct light-field calibration provides significant computational benefits by eliminating some intermediate processing steps found in other methods. Finally, the flexibility of this method is shown for a nonplanar calibration.

47 OTHER INSTRUMENTATION↗

Automatic Calibration of a Geomechanical Model from Sparse Data for Estimating Stress in Deep Geological Formations

Summary In this study, we demonstrate geomechanical modeling with fully automatic parameter calibration to estimate the full geomechanical stress fields of a prospective US carbon dioxide (CO2) storage site, based on sparse measurement data. The goal is to compute full stress tensor field estimates (principal stresses and orientations) that are maximally compatible with observations within the constraints of the model assumptions, thereby extending pointwise, incomplete partial stress measurement to a simulated full formation stress field, as well as a rough assessment of the associated error. We use the Perch site, located in Otsego County, Michigan, USA, as our case study. The input data consist of partial stress tensor information inferred from in-situ borehole tests, geophysical well logs, and processing of seismic data. A static earth model (SEM) of the site was developed, and geomechanical simulation functionality of the open-source MATLAB Reservoir Simulation Toolbox (MRST) was used to model the stress field. Adjoint-based nonlinear optimization was used to adjust boundary conditions and material properties to calibrate simulated results of observations. Results were interpreted through a Bayesian framework. The focus of this paper is to demonstrate how the fully automatic calibration procedure works and discuss the results obtained; it does not attempt a detailed analysis of the stress field in the context of the proposed CO2 storage initiatives. Our work is part of a larger effort to noninvasively determine in-situ stresses in deep formations considered for CO2 storage. Guided by previously published research on geomechanical model calibration, our work presents a novel calibration approach supporting a potentially large number of linear or nonlinear calibration parameters to produce results optimally agreeing with available measurements and thus extend partial pointwise estimates to full tensor fields compatible with the physics of the site.

Engineering↗

PBX9502 PAGOSA/SURF Calibration for 100 µm Grid Size

There are two methods to calibrate the SURF reactive burn explosives model.The first is to calibrate using Pop plot data. Because there are only two main parameters in SURF, called A and B, there is just enough flexibility in SURF to determine the Pop plot line, i.e., equivalent information to a slope and a single point on the line. However, due to the linearity of the Pop plot being based on logarithmic scales, a slight deviation off the Pop plot (though the fit to the Pop plot might be very good overall) can make considerable difference when comparing with the velocity profile data. The second calibration method thusly focuses strongly on matching entire velocity profile data. This is to say that individual velocity profiles extracted from embedded gages (in the case of PBX 9502, we refer to R. Gustavsen’s experimental data) may fit poorly, while the overall fit to the Pop plot may seem reasonable. In addition, there are other factors that could produce slightly different calibrations for SURF, while leading to an overall acceptable fit to data. One of those may be the physics code used and here we use Pagosa. Another is mesh size dependence. A third one stems from fitting a reactive burn model being done in conjunction with an equation of state (EOS) of the reactants and one for the products – different EOS can result in slightly different parameterizations. Finally, there are several secondary material parameters in SURF, and the overall fit will depend on the entire parameterization. The goal of this report is to clarify some of our previously made statements about SURF calibration, as well as to redo a systematic calibration using 100 µm grid resolution.

42 ENGINEERING↗

Thermal-Mechanical Elastic-Plastic and Ductile Failure Model Calibrations for 304L Stainless Steel Alloy

Numerical simulations of metallic structures undergoing rapid loading into the plastic range require material models that accurately represent the response. In general, the material response can be seen as having four interrelated parts: the baseline response under slow loading, the effect of strain rate, the conversion of plastic work into heat and the effect of temperature. In essence, the material behaves in a thermal-mechanical manner if the loading is fast enough so when heat is generated by plastic deformation it raises the temperature and therefore influences the mechanical response. In these cases, appropriate models that can capture the aspects listed above are necessary. The material of interest here is 304L stainless steel, and the objective of this work is to calibrate thermal-mechanical models: one for the constitutive behavior and another for failure. The work was accomplished by first designing and conducting a material test program to provide data for the calibration of the models. The test program included uniaxial tension tests conducted at room temperature, 150 and 300 C and at strain rates between 10 –4 and 10 3 1/s. It also included notched tension and shear-dominated compression hat tests specifically designed to calibrate the failure model. All test specimens were extracted from a single piece of plate to maintain consistency. The constitutive model adopted was a modular $J_2$ plasticity model with isotropic hardening that included rate and temperature dependence. A criterion for failure initiation based on a critical value of equivalent plastic strain fitted the failure data appropriately and was adopted. Possible ranges of the values of the parameters of the models were determined partially on historical data from calibrations of the same alloy from other lots and are given here. The calibration of the parameters of the models were based on finite element simulations of the various material tests using relatively ne meshes and hexahedral elements. When using the model in structural finite element calculations, however, element formulations and sizes different from those in the calibration are likely to be used. A brief investigation demonstrated that the failure initiation predictions can be particularly sensitive to the element selection and provided an initial guide to compensate for the effect of element size in a specific example.

36 MATERIALS SCIENCE↗

Prompt Gamma Analysis of ARIES Materials and Updates to the 2015 Calibration Equations

Prompt gamma (PG) analysis is a nondestructive, nuclear, elemental analysis technique that uses charged particle reactions to interrogate a sample, and elements present in the sample matrix are identified through the characteristic gamma-rays emitted from the product nuclei in alpha-p and alpha-n nuclear reactions. This technique has been applied to plutonium oxide packaged in over 4,000 individual 3013 containers, and the concentrations of certain light elements were determined from the integrated peak areas based on a calibration that was published previously. This report provides the results for a new population of 3013 containers packaged with oxide materials produced by the conversion of metal by Advanced Recovery and Integrated Extraction System (ARIES) project using the direct metal oxidation (DMO) process and muffle furnaces. New PG and analytical chemistry data collected since 2015 were added to the existing calibration data sets to refine the calibration parameters. Calibration equations were also developed for determining beryllium and fluorine at low concentrations in high-purity ARIES product oxides. The new fluorine calibration provides an order of magnitude greater sensitivity and results in an additional 1,408 containers in the original population identified as having fluorine as an impurity. Additionally, equations for calculating the lower limits of detection (LLDs) as a function of the actual counting time (live time) were obtained using WLS regression technique for samples in the calibration data set. This resulted in changes to the LLDs published previously.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COMBLE Radar b1 Processing: Corrections, Calibrations, and Processing Report

The U.S. Department of Energy’s (DOE) Atmospheric Radiation Measurement (ARM) user facility recently concluded its Cold-Air Outbreaks in the Marine Boundary Layer Experiment (COMBLE), with its campaign emphasis on marine boundary-layer clouds and mixed-phase clouds during cold-air outbreaks. The COMBLE campaign featured the deployment of the first ARM Mobile Facility (AMF1) to northern Scandinavia (Andenes, Norway), including its standard complement of ARM cloud radars. In keeping with user demands stemming from the previous AMF Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina, a post-campaign radar mentor effort was initiated for COMBLE. This activity was intended to improve the usability of the ARM cloud radar data sets in response to overall demands for calibrated, corrected data sets for downstream studies and retrieval applications. In addition to the terrain complexities previously important to CACTI data sets (e.g., clutter designation and/or removal), COMBLE presented new challenges to existing ARM radar mentor capabilities. These included the extension of existing methodologies (e.g., relative calibration adjustment [RCA] target techniques) to frozen environments and the potential issues with their applicability when considering mixed-phase precipitation conditions. As in the previous CACTI documentation (Hardin et al. 2020), the overall calibration and conditioning process in ARM nomenclature is referred to as generating a “b1” datastream. For the radars, these “b1” standards refer to a datastream that has been calibrated (and cross-calibrated), with effort to deliver the highest-quality (well-characterized) data possible. The “b1” radar mentor reporting (this current document) is intended to detail (i) the status/quality of the original “a1” (raw) data sets during the COMBLE AMF campaign, (ii) the corrections and calibrations that are applied to generate the b1 datastreams available on ARM’s Data Discovery, and (iii) the details of the applied methods, e.g., how radar offset/calibration numbers were determined.

54 ENVIRONMENTAL SCIENCES↗

The Dark Energy Survey Six-Year Calibration Star Catalog

This Technical Note presents a catalog of calibrated reference stars that was generated by the Forward Calibration Method (FGCM) pipeline (arXiv:1706.01542) as part of the FGCM photometric calibration of the full Dark Energy Survey (DES) 6-Year data set (Y6). This catalog provides DES grizY magnitudes for 17 million stars with i-band magnitudes mostly in the range 16 < i < 21 spread over the full DES footprint covering 5000 square degrees over the Southern Galactic Cap at galactic latitudes b < -20 degrees (plus a few outlying fields disconnected from the main survey footprint). These stars are calibrated to a uniformity of better than 1.8 milli-mag (0.18%) RMS over the survey area. The absolute calibration of the catalog is computed with reference to the STISNIC.007 spectrum of the Hubble Space Telescope CalSpec standard star C26202; including systematic errors, the absolute flux system is known at the approximately 1% level. As such, these stars provide a useful reference catalog for calibrating grizY-band or grizY-like band photometry in the Southern Hemisphere, particularly for observations within the DES footprint.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency-Selectable Laser Source (FLS) Calibrator for CMB Bandpass Characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from our detector bandpass calibration. Uncertainties in bandpass can severely limit our measurements by limiting foreground removal and spectral fitting, which is particularly important for high-$\ell$ observations like cluster science using the Sunyaev-Zeldovich (SZ) effect. Currently, CMB experiments typically use a Fourier Transform Spectrometer (FTS) to measure the detector bandpasses. However, the resolution of the FTS is dependent on the length of the interferometer arms, leading to a need for increasingly large FTS instruments as CMB experiments require tighter constraints on detector bandpasses. Additionally, systematic effects like shifts in bandpass shape from uneven illumination from the FTS further limit the calibration uncertainties. As a complement to the FTS, we have developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency housed in a calibrator that allows for varying degrees of laser power attenuation. We present several tests used to characterize the first prototype design of the FLS calibrator, as well as the improvements to the calibrator design currently underway.

Saunders, Lauren [Fermilab]↗

Measurement and calibration of non-linear shear terms in galaxy cluster fields

Introduction Galaxy cluster lensing is a powerful tool for measuring the mass of galaxy clusters, but accurate shear measurement and calibration are critical to obtaining reliable results. This study focuses on the measurement and calibration of weak lensing shears to improve mass estimates in cluster lensing. To deal with the problem, we first developed an image simulation pipeline, jedisim, which utilizes galaxy images extracted from the Hubble Space Telescope (HST) Ultra Deep Field (UDF) and the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS). Methods The simulations represent realistic galaxy distributions and morphologies as input sources. The foreground halo with a Navarro–Frenk–White (NFW) profile is constructed such that the lensing signals of background galaxies can be measured by the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) Science Pipelines. By comparing the measured reduced shear g meas and the true reduced shear g true , we observe non-linearity up to g ≲ 0.6 . We fit polynomials to the data with quadratic correction adequate to g ≲ 0.4 . Meanwhile, we conduct mass estimates using the pzmassfitter code on four different clusters. Results The mass estimate results are significantly improved after applying the shear calibration derived from the present work—from 4.954 ± 0.504 × 1 0 14 M ⊙ to 10.507 ± 0.498 × 1 0 14 M ⊙ after calibration for a simulated cluster with the mass of 10 × 1 0 14 M ⊙ . In multiple cases of validation, the estimated results are all consistent with true cluster mass. Discussion This study yields the first relationship between reality and shape measurement of the LSST Science Pipelines and serves as the first step toward the overall goal of mass calibration in cluster lensing. By addressing the challenges in shear measurement and calibration, we aim to enhance the accuracy and reliability of mass estimates in galaxy cluster lensing studies.

Astronomy & Astrophysics↗

Calibration of the 2007–2017 record of Atmospheric Radiation Measurements cloud radar observations using CloudSat

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurements (ARM) facility has been at the forefront of millimeter-wavelength radar development and operations since the late 1990s. The operational performance of the ARM cloud radar network is very high; however, the calibration of the historical record is not well established. Here, a well-characterized spaceborne 94&thinsp;GHz cloud profiling radar (CloudSat) is used to characterize the calibration of the ARM cloud radars. The calibration extends from 2007 to 2017 and includes both fixed and mobile deployments. Collectively, over 43 years of ARM profiling cloud radar observations are compared to CloudSat and the calibration offsets are reported as a function of time using a sliding window of 6 months. The study also provides the calibration offsets for each operating mode of the ARM cloud radars. Overall, significant calibration offsets are found that exceed the uncertainty of the technique (1–2&thinsp;dB). The findings of this study are critical to past, ongoing, and planned studies of cloud and precipitation and should assist the DOE ARM to build a legacy decadal ground-based cloud radar dataset for global climate model validation.

54 ENVIRONMENTAL SCIENCES↗

Calibrating radar wind profiler reflectivity factor using surface disdrometer observations

Abstract. This study uses surface disdrometer reflectivity factor estimates to calibrate the vertical and off-vertical pointing radar beams produced by an ultra high frequency (UHF) band radar wind profiler (RWP) deployed at the US Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) program Southern Great Plains (SGP) Central Facility in northern Oklahoma from April 2011 through July 2019. The methodology consists of five steps. First, the recorded Doppler velocity power spectra are adjusted to account for Nyquist velocity aliasing and coherent integration filtering effects. Second, the spectrum moments are calculated. The third step increases the signal-to-noise ratio (SNR) due to inflated noise power estimates during convective rain events that cause SNR to be biased low. The fourth step determines the RWP calibration constant for one radar beam (called the “reference” beam) by comparing uncalibrated RWP reflectivity factors at 500 m above the ground to 1 min resolution surface disdrometer reflectivity factors. The last step uses the calibrated reference beam reflectivity factor to calibrate the other radar beams during precipitation. There are two key findings. The RWP sensitivity decreased by approximately 3 to 4 dB yr−1 as the hardware aged. This drift was slow enough that the reference calibration constant can be estimated over 3-month intervals using episodic rain events. The calibrated moments are available on the DOE ARM data archive, and the Python processing code is available on public repositories.

54 ENVIRONMENTAL SCIENCES↗