Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Investigation of Critical Heat Flux in Reduced Gravity Using Photomicrographic Techniques

Experiments were performed to examine the effects of body force on flow boiling critical heat flux (CHF). FC-72 was boiled along one wall of a transparent rectangular flow channel that permitted photographic study of the vapor-liquid interface just prior to CHF. High-speed video imaging techniques were used to identify dominant CHF mechanisms corresponding to different flow orientations and liquid velocities. Six different CHF regimes were identified: Wavy Vapor Layer, Pool Boiling, Stratification, Vapor Counterflow, Vapor Stagnation, and Separated Concurrent Vapor Flow. CHF showed significant sensitivity to orientation for flow velocities below 0.2 m/s, where extremely low CHF values where measured, especially with downward-facing heated wall and downflow orientations. High flow velocities dampened the effects of orientation considerably. The CHF data were used to assess the suitability of previous CHF models and correlations. It is shown the Interfacial Lift-off Model is very effective at predicting CHF for high velocities at all orientations. The flooding limit, on the other hand, is useful at estimating CHF at low velocities and for downflow orientations. A new method consisting of three dimensionless criteria is developed for determining the minimum flow velocity required to overcome body force effects on near-saturated flow boiling CHF. Vertical upflow boiling experiments were performed in pursuit of identifying the trigger mechanism for subcooled flow boiling CHF. While virtually all prior studies on flow boiling CHF concern the prediction or measurement of conditions that lead to CHF, this study was focused on events that take place during the CHF transient. High-speed video imaging and photomicrographic techniques were used to record the transient behavior of interfacial features from the last steady-state power level before CHF until the moment of power cut-off following CHF. The video records show the development of a wavy vapor layer which propagates along the heated wall, permitting cooling prior to CHF only in wetting fronts corresponding to the wave troughs. Image analysis software was developed to estimate void fraction from the individual video images. The void fraction records for subcooled flow boiling show the CHF transient is accompanied by gradual lift-off of wetting fronts culminating in some maximum vapor layer mean thickness, following which the vapor layer begins to thin down as the transition to film boiling ensues. This study proves the Interfacial Lift-off Model, which has been validated for near-saturated flow boiling CHF, is equally valid for subcooled conditions.

Mudawar, Issam↗

Critical Heat Flux of Liquid Hydrogen, Liquid Methane, and Liquid Oxygen: A Review of Available Data and Predictive Tools

Available experimental data dealing with critical heat flux (CHF) of liquid hydrogen (LH 2 ), liquid methane (LCH 4 ), and liquid oxygen (LO 2 ) in pool and flow boiling are compiled. The compiled data are compared with widely used correlations. Experimental pool boiling CHF data for the aforementioned cryogens are scarce. Based on only 25 data points found in five independent sources, the correlation of Sun and Lienhard (1970) is recommended for predicting the pool CHF of LH 2 . Only two experiments with useful CHF data for the pool boiling of LCH 4 could be found. Four different correlations including the correlation of Lurie and Noyes (1964) can predict the pool boiling CHF of LCH 4 within a factor of two for more than 70% of the data. Furthermore, based on the 19 data points taken from only two available sources, the correlation of Sun and Lienhard (1970) is recommended for the prediction of pool CHF of LO 2 . Flow boiling CHF data for LH 2 could be found in seven experimental studies, five of them from the same source. Based on the 91 data points, it is suggested that the correlation of Katto and Ohno (1984) be used to predict the flow CHF of LH 2 . No useful data could be found for flow boiling CHF of LCH 4 or LO 2 . The available databases for flow boiling of LCH 4 and LO 2 are generally deficient in all boiling regimes. This deficiency is particularly serious with respect to flow boiling.

Multi-Phase Flow↗

Critical Heat Flux of Liquid Hydrogen, Liquid Methane, and Liquid Oxygen: A Review of Available Data and Predictive Tools

Available experimental data dealing with critical heat flux (CHF) of liquid hydrogen (LH2), liquid methane (LCH4), and liquid oxygen (LO2) in pool and flow boiling are compiled. The compiled data are compared with widely used correlations. Experimental pool boiling CHF data for the aforementioned cryogens are scarce. Based on only 25 data points found in five independent sources, the correlation of Sun and Lienhard (1970) is recommended for predicting the pool CHF of LH2. Only two experiments with useful CHF data for the pool boiling of LCH4 could be found. Four different correlations including the correlation of Lurie and Noyes (1964) can predict the pool boiling CHF of LCH4 within a factor of two for more than 70% of the data. Furthermore, based on the 19 data points taken from only two available sources, the correlation of Sun and Lienhard (1970) is recommended for the prediction of pool CHF of LO2. Flow boiling CHF data for LH2 could be found in seven experimental studies, five of them from the same source. Based on the 91 data points, it is suggested that the correlation of Katto and Ohno (1984) be used to predict the flow CHF of LH2. No useful data could be found for flow boiling CHF of LCH4 or LO2. The available databases for flow boiling of LCH4 and LO2 are generally deficient in all boiling regimes. This deficiency is particularly serious with respect to flow boiling.

Multi-Phase Flow↗

Alkali metal pool boiler life tests for a 25 kWe advanced Stirling conversion system

The overall operating temperature and efficiency of solar-powered Stirling engines can be improved by adding an alkali metal pool boiler heat transport system to supply heat more uniformly to the heater head tubes. One issue with liquid metal pool boilers is unstable boiling. Stable boiling is obtained with an enhanced boiling surface containing nucleation sites that promote continuous boiling. Over longer time periods, it is possible that the boiling behavior of the system will change. An 800-h life test was conducted to verify that pool boiling with the chosen fluid/surface combination remains stable as the system ages. The apparatus uses NaK boiling on a - 100 + 140 stainless steel sintered porous layer, with the addition of a small amount of xenon. Pool boiling remained stable to the end of life test. The pool boiler life test included a total of 82 cold starts, to simulate startup each morning, and 60 warm restarts, to simulate cloud cover transients. The behavior of the cold and warm starts showed no significant changes during the life test. In the experiments, the fluid/surface combination provided stable, high-performance boiling at the operating temperature of 700 C. Based on these experiments, a pool boiler was designed for a full-scale 25-kWe Stirling system.

Anderson, W. G.↗

Economic and Environmental Analysis to Evaluate the Potential Value of Co-Optima Diesel Bioblendstocks to Petroleum Refiners

The U.S. petroleum refining sector is undergoing a period of historic transformation, catalyzed by the decarbonization of the U.S. economy. Diesel-boiling-range bioblendstocks have gained traction, owing to their superior fuel properties and environmental performance as compared to traditional petroleum fuels. This work couples refinery linear programming models with life cycle assessment to quantify the potential economic and environmental benefits, and trade-offs, of blending diesel-boiling-range bioblendstocks at petroleum refineries. Linear programming models were developed in Aspen Process Industry Modeling Systems (PIMS) for three representative petroleum refinery configurations of differing complexity. Seven diesel-boiling-range bioblendstocks: 4-butoxyheptane, 5-ethyl-4-propylnonane, soy biodiesel, sludge hydrothermal liquefaction diesel, polyoxymethylene ethers, renewable diesel, and hexyl hexanoate, were investigated to identify key fuel properties that influence refineries' economics and to track the effect of adding bioblendstocks on refinery-wide cradle-to-gate greenhouse gases (GHG) emissions. These analyses considered blending levels from 10 to 30 vol% and fuel demand projections over the period 2040 to 2050. This analysis determines that bioblendstock sulfur content and cetane number are the primary fuel attributes with the potential to provide value to refiners. Life cycle assessment results indicate that the use of diesel-boiling-range bioblendstocks can reduce cradle-to-gate refinery GHG emissions by up to ~ 40 % relative to conventional refinery operations when considering carbon uptake in the supply chain of the bioblendstock. Refinery-wide marginal GHG abatement costs range from 120 to 3,600 USD2016/metric tons carbon dioxide equivalent avoided across the scenarios evaluated. Reducing the price of bioblendstocks is identified as a key to their adoption.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS,ENERGY P↗

Multicomponent gas sorption Joule-Thomson refrigeration

The present invention relates to a cryogenic Joule-Thomson refrigeration capable of pumping multicomponent gases with a single stage sorption compressor system. Alternative methods of pumping a multicomponent gas with a single stage compressor are disclosed. In a first embodiment, the sorbent geometry is such that a void is defined near the output of the sorption compressor. When the sorbent is cooled, the sorbent primarily adsorbs the higher boiling point gas such that the lower boiling point gas passes through the sorbent to occupy the void. When the sorbent is heated, the higher boiling point gas is desorbed at high temperature and pressure and thereafter propels the lower boiling point gas out of the sorption compressor. A mixing chamber is provided to remix the constituent gases prior to expansion of the gas through a Joule-Thomson valve. Other methods of pumping a multicomponent gas are disclosed. For example, where the sorbent is porous and the low boiling point gas does not adsorb very well, the pores of the sorbent will act as a void space for the lower boiling point gas. Alternatively, a mixed sorbent may be used where a first sorbent component physically adsorbs the high boiling point gas and where the second sorbent component chemically absorbs the low boiling point gas.

Jones, Jack A.↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Tank Pressure Control Experiment: Thermal Phenomena in Microgravity

The report presents the results of the flight experiment Tank Pressure Control Experiment/Thermal Phenomena (TPCE/TP) performed in the microgravity environment of the space shuttle. TPCE/TP, flown on the Space Transportation System STS-52, was a second flight of the Tank Pressure Control Experiment (TPCE). The experiment used Freon 113 at near saturation conditions. The test tank was filled with liquid to about 83% by volume. The experiment consisted of 21 tests. Each test generally started with a heating phase to increase the tank pressure and to develop temperature stratification in the fluid, followed by a fluid mixing phase for the tank pressure reduction and fluid temperature equilibration. The heating phase provided pool boiling data from large (relative to bubble sizes) heating surfaces (0.1046 m by 0.0742 m) at low heat fluxes (0.23 to 1.16 kW/sq m). The system pressure and the bulk liquid subcooling varied from 39 to 78 kPa and 1 to 3 C, respectively. The boiling process during the entire heating period, as well as the jet-induced mixing process for the first 2 min of the mixing period, was also recorded on video. The unique features of the experimental results are the sustainability of high liquid superheats for long periods and the occurrence of explosive boiling at low heat fluxes (0.86 to 1.1 kW/sq m). For a heat flux of 0.97 kW/sq m, a wall superheat of 17.9 C was attained in 10 min of heating. This superheat was followed by an explosive boiling accompanied by a pressure spike of about 38% of the tank pressure at the inception of boiling. However, at this heat flux the vapor blanketing the heating surface could not be sustained. Steady nucleate boiling continued after the explosive boiling. The jet-induced fluid mixing results were obtained for jet Reynolds numbers of 1900 to 8000 and Weber numbers of 0.2 to 6.5. Analyses of data from the two flight experiments (TPCE and TPCE/TP) and their comparison with the results obtained in drop tower experiments suggest that as Bond number approaches zero the flow pattern produced by an axial jet and the mixing time can be predicted by the Weber number.

Hasan, Mohammad M.↗

Ares I Reaction Control System Propellant Feedline Decontamination Modeling

The objective of the work presented here is to quantify the effects of purge gas temperature, pressure, and mass flow rate on Hydrazine (Hz) decontamination rates of the Ares I Roll Control System and Reaction Control System. A survey of experts in this field revealed the absence of any decontamination rate prediction models. Three basic decontamination methods were identified for analysis and modeling. These include low pressure eduction, high flow rate purge, and pulse purge. For each method, an approach to predict the Hz mass transfer rate, as a function of system pressure, temperature, and purge gas mass flow rate, is developed based on the applicable physics. The models show that low pressure eduction is two orders of magnitude more effective than the high velocity purge, which in turn is two orders of magnitude more effective than the pure diffusion component of pulse purging of deadheads. Eduction subjects the system to low pressure conditions that promote the extraction of Hz vapors. At 120 F, Hz is saturated at approximately 1 psia. At lower pressures and 120 F, Hz will boil, which is an extremely efficient means to remove liquid Hz. The Hz boiling rate is predicted by equating the rate at which energy is added to the saturated liquid Hz through heaters at the tube outer wall with the energy removed from the liquid through evaporation. Boil-off fluxes were predicted by iterating through the range of local pressures with limits set by the minimum allowed pressure of 0.2 psia and maximum allowed wall temperature of 120 F established by the heaters, which gives a saturation pressure of approximately 1.0 psia. Figure 1 shows the resulting boil-off fluxes as a function of local eduction pressure. As depicted in figure 1, the flux is a strong inverse function of eduction pressure, and that minimizing the eduction pressure maximizes the boil-off flux. Also, higher outer wall temperatures lead to higher boil-off fluxes and allow for boil-off over a greater range of eduction pressures.

Pasch, James J.↗

Development and Validation of a Two-Phase Thermal-Hydraulic CFD Code NEK-2P

A project is underway to develop, verify and validate an advanced two-phase flow modeling capability for the highly-scalable, high-performance Computational Fluid Dynamics (CFD) code NEK5000. The goal of this work is to verify and validate the two-phase version of the NEK5000 code, named NEK-2P, to simulate the two-phase flow and heat transfer phenomena that occur in a Boiling Water Reactor (BWR) fuel bundle under various operating conditions. The NEK-2P two-phase flow models follow the approach used for the Extended Boiling Framework (EBF) previously developed at Argonne but include more fundamental physical models of boiling phenomena and advanced numerical algorithms for improved computational accuracy, robustness, and computational speed. The development of the NEK-2P two-phase solver and the implementation of the Extended Boiling Framework two-phase models were initially supported by Argonne National Laboratory (Argonne) through a Laboratory Directed Research and Development (LDRD) project during FY2014-2016. The development and validation of the two-phase models through analyses of selected two-phase boiling flow experiments was supported by the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in FY2017-2020. This report focuses on verification and validation of the water-steam boiling model NEK-2P Two-Phase, CFD code. The NEK-2P was validated with Nuclear Power Engineering Corporation (NUPEC) Pressurized Water Reactor (PWR) Sub-channel and Bundle Test (PSBT) void distribution benchmark. Three different simulations were performed and analyzed for various operating conditions such as wall-heat flux and sub-cooled inlet temperatures. Reasonably good agreement with measured data was obtained in predicting the measured void distributions. Simulations were performed for Virginia Tech. (VT) 3x3 rod bundle geometry with and without spacers. The preliminary results were presented for Simplified Spacer Grid (SSG). In addition, the implementation of interface reconstruction model was tested with one of the Becker benchmark Critical Heat Flux (CHF) experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗