Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

MR Venography of Deep Veins: Changes with Uterine Fibroid Embolization

Deep veins (DVs) can be compressed by a uterus enlarged with fibroids. The purpose of this study was to assess the degree of luminal narrowing of DVs caused by a myomatous uterus, and the change in DV narrowing in women with symptomatic fibroids after embolization using time-of-flight (TOF)-magnetic resonance venography (MRV). Twenty-nine consecutive women with symptomatic uterine fibroids underwent TOF-MRV and pelvic MRI before and 4 months after embolization. Based on the TOF-MRV, we evaluated the luminal narrowing of three DVs, including the inferior vena cava, and the bilateral common and external iliac veins, and divided the findings into three grades. The scores for each DV were added for each patient (lowest, 0; highest, 6). DV scores and symptom severity (SS) scores were compared between the baseline and 4 months after embolization using the paired t-test. The relationship between DV scores and uterine volume was investigated using Pearson's test. DV scores decreased significantly, from 1.52 {+-} 1.70 at baseline to 0.93 {+-} 1.56 at 4 months after embolization (p = 0.004). The uterine volume decreased from 948 {+-} 647 mL at baseline to 617 {+-} 417 mL at 4 months after embolization (p < 0.001). DV score correlated with uterine volume (r = 0.856, p < 0.001). SS scores decreased from 54.5 {+-} 14.6 at baseline to 26.8 {+-} 15.4 at 4 months after embolization (p < 0.001). In conclusion, the degree of luminal narrowing of DVs caused by a uterus with fibroids is correlated with the uterine volume. Uterine artery embolization may induce an improvement of luminal narrowing of DVs due to a reduction of the myomatous uterus volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Angiography: Current Status in the Planning and Follow-Up of Endovascular Treatment in Lower-Limb Arterial Disease

Magnetic resonance angiography (MRA) has become an established imaging modality in the management of lower-limb arterial disease, with emerging roles in treatment planning and follow-up. Contrast-enhanced MRA is now the most widely used technique with clinically acceptable results in the majority of patients. Difficulties in imaging and image interpretation are recognised in certain subgroups, including patients with critical limb ischaemia as well as patients with stents. Although newer contrast agents and refined imaging protocols may offer some solutions to these problems, this optimism is balanced by concerns about the toxicity of certain gadolinium chelates. Further development of interventional MRA remains one of the most significant challenges in the development of magnetic resonance imaging-guided peripheral vascular intervention. The status of MRA in managing patients with lower-limb arterial disease in current clinical practice is reviewed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Cone-Beam Computed Tomography During Ultraselective Transcatheter Arterial Chemoembolization for Small Hepatocellular Carcinomas that Cannot be Demonstrated on Angiography

This study evaluated the usefulness of cone-beam computed tomography (CBCT) during ultraselective transcatheter arterial chemoembolization (TACE) for hepatocellular carcinomas (HCC) that could not be demonstrated on angiography. Twenty-eight patients with 33 angiographically occult tumors (mean diameter 1.3 {+-} 0.3 cm) were enrolled in the study. The ability of CBCT during arterial portography (CBCTAP), during hepatic arteriography (CBCTHA), and after iodized oil injection (LipCBCT) to detect HCC lesions was retrospectively analyzed. The technical success of TACE was divided into three grades: complete (the embolized area included the entire tumor with at least a 5-mm wide margin), adequate (the embolized area included the entire tumor but without a 5-mm wide margin in parts), and incomplete (the embolized area did not include the entire tumor) according to computed axial tomographic (CAT) images obtained 1 week after TACE. Local tumor progression was also evaluated. CBCTAP, CBCTHA, and LipCBCT detected HCC lesions in 93.9% (31 of 33), 96.7% (29 of 30), and 100% (29 of 29) of patients, respectively. A single branch was embolized in 28 tumors, and 2 branches were embolized in five tumors. Twenty-seven tumors (81.8%) were classed as complete, and 6 (18.2%) were classed as adequate. None of the tumors were classed as incomplete. Twenty-five tumors (75.8%) had not recurred during 12.0 {+-} 6.2 months. Eight tumors (24.2%), 5 (18.5%) of 27 complete success and 3 (50%) of 6 adequate success, recurred during 10.1 {+-} 6.2 months. CBCT during TACE is useful in detecting and treating small HCC lesions that cannot not be demonstrated on angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of a Right-Sided Descending Thoracic Aortic Aneurysm Associated with a Right Aortic Arch and a Left Subclavian Artery Arising from a Kommerell's Diverticulum

This case report describes the endovascular repair of a right-sided descending thoracic aortic aneurysm associated with a right aortic arch and an aberrant left subclavian artery. A 76-year-old male with multiple comorbidities was incidentally found to have a right-sided descending thoracic aortic aneurysm with a maximum diameter of 6.2 cm. Additionally, there was a right aortic arch with a retroesophageal segment and separate arch branches arising in the following order: left common carotid artery, right common carotid artery, right subclavian artery, and left subclavian artery that was aberrant, arising from a Kommerrell's diverticulum. The aneurysm was successfully excluded by deployment of a Zenith TX1 36 x 32 x 20-mm stent-graft using wire traction technique via the left femoral and right brachial arteries in order to deal with two severe aortic angulations. At 18-month follow-up the patient was doing well, with aneurysm sac shrinkage to 5.9 cm and no signs of endoleak or migration. Endovascular repair of right-sided descending thoracic aortic aneurysms with a right arch and aberrant left subclavian artery is feasible, safe, and effective. In such rare configurations, which demand considerably increased technical dexterity and center experience, endovascular repair emerges as an attractive therapeutic option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Importance of Dose Settings in the X-Ray Systems Used for Interventional Radiology: A National Survey

The purpose of this work was to investigate the differences in dose settings among the X-ray units involved in a national survey of patient doses in interventional radiology (IR). The survey was promoted by the National Society of IR and involved 10 centers. As part of the agreed quality control for the survey, entrance doses were measured in a 20-cm-thick acrylic phantom simulating a medium-sized patient. A standard digital subtraction angiography (DSA) imaging protocol for the abdomen was used at the different centers. The center of the phantom was placed at the isocenter of the C-arm system during the measurements to simulate clinical conditions. Units with image intensifiers and flat detectors were involved in the survey. Entrance doses for low, medium, and high fluoroscopy modes and DSA acquisitions were measured for a field of view of 20 cm (or closest). A widespread range of entrance dose values was obtained: 4.5-18.6, 9.2-28.4, and 15.4-51.5 mGy/min in low, medium, and high fluoroscopy mode, respectively, and 0.7-5.0 mGy/DSA image. The ratios between the maximum and the minimum values measured (3-4 for fluoroscopy and 7 for DSA) suggest an important margin for optimization. The calibration factor for the dose-area product meter was also included in the survey and resulted in a mean value of 0.73, with a standard deviation of 0.07. It seems clear that the dose setting for the X-ray systems used in IR requires better criteria and approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Retrieval of a Radiolucent Foreign Body from an EVAR Device by Combining Different Image Modalities

Percutaneous extraction techniques are an established method for removing endovascular foreign bodies. Generally, the foreign body to be removed is radiopaque (i.e., catheter and guidewire fragments, vena cava filters, embolization coils, endovascular stents). We propose an application of these techniques to remove a radiolucent foreign body (i.e., pigtail cover) by means of a combination of different imaging techniques (fluoroscopy, digital subtraction angiography, ultrasound, and computed axial tomography).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Clinical Outcomes with Regular- and Low-Profile Totally Implanted Central Venous Port Systems

The purpose of this study was to evaluate whether low-profile totally implanted central venous port systems can reduce the late complication of skin perforation. Forty patients (age, 57 {+-} 13 years; 22 females, 18 males) were randomized for the implantation of a low-profile port system, and another 40 patients (age, 61 {+-} 14 years; 24 females, 16 males) received a regular port system as control group. Indications for port catheter implantation were malignant disease requiring chemotherapy. All port implantations were performed in the angiography suite using sonographically guided central venous puncture and fluoroscopic guidance of the catheter placement. Procedure time, number of complications (procedure-related immediate, early, and late complications), and number of explantations were assessed. Follow-up was performed for 6 months. All port implantations were successfully completed in both study groups. There were two incidents of skin perforation observed in the control group. One skin perforation occurred 13 weeks and the other 16 weeks after port implantation (incidence, 5%) in patients with regular-profile port systems. Two infections were observed, one port infection in each study group. Both infections were characterized as catheter-related infections (infection rate: 0.15 catheter-related infections per 1000 catheter days). In conclusion, low-profile port systems can be placed as safely as traditional chest ports and reduce the risk of developing skin perforations, which occurs when the port system is too tight within the port pocket.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AngioJet Thrombectomy for Occluded Dialysis Fistulae: Outcome Data

This study evaluates AngioJet thrombectomy of occluded autogenous dialysis fistulae and polytetrafluoroethylene (PTFE) grafts in a UK hemodialysis population. Comparison is made with published data of alternative percutaneous thrombectomy methods. All patients with occluded dialysis fistulae who sought care at the Royal Liverpool University Hospital between October 2006 and June 2008 were included in the study. All patients were treated with the AngioJet Rheolytic Thrombectomy Device (Possis, Minneapolis, MN). Demographics, time of occlusion, adjunctive therapies, complications, and follow-up data have been prospectively recorded. A total of 64 thrombectomy procedures were performed in 48 patients. Forty-four autogenous fistulas were treated in 34 patients (19 brachiocephalic, 8 radiocephalic, and 7 transposed brachiobasilic). Twenty PTFE grafts were treated in 14 patients (9 brachioaxillary, 3 brachiocephalic loop grafts, 1 brachiobasilic, and 1 femoro-femoral). The average length of occlusion was 24 cm. Average time to intervention was 4 days. Immediate primary patency was 91%. Primary patency at 1, 3, and 6 months, respectively, was 71%, 60%, and 37%. Secondary patency at 3, 6, and 12 months was 87%, 77%, and 62%, respectively. Angioplasty was carried out in all procedures. Patients required stent insertion in 34 of the 64 thrombectomies to treat angioplasty-resistant stenoses. Complications included a puncture-site hematoma, and three angioplasty-related vein ruptures in one patient, all treated with covered stent grafts. Two cases of distal brachial arterial embolization were successfully treated by thrombosuction. AngioJet thrombectomy in dialysis access occlusion is safe and effective, comparing favorably with other methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cryoplasty for Occlusive Disease of the Femoropopliteal Arteries: 1-Year Follow-Up

Atherosclerosis of femoropopliteal arteries is an important cause of morbidity and mortality. Percutaneous transluminal angioplasty (PTA) has only limited success in treating these arteries, mainly because of the high rate of recurrent stenosis. Cryoplasty has been proposed as a technique which might improve treatment outcome. This study reports our single-center experience with cryoplasty. Thirty-two claudicants, 33 arteries, in whom conservative therapy failed, were consecutively included. Duplex ultrasound (US), angiography, and ankle-brachial index (ABI) measurement were performed before the procedure; ABI and duplex US, 2 weeks and 3, 6, and 12 months after the procedure. Patients' symptoms were categorized according to the Rutherford classification. Lesions were classified as TASC A, B, or C according to angiographic appearance. Differences in ABI before and after the procedure were defined as significant at p < 0.05 by paired t-test. Patency was evaluated using duplex US by determining the peak systolic velocity ratio. Sixteen TASC A lesions, 13 TASC B lesions, and 4 TASC C lesions were included. ABI improved significantly for TASC A lesions 2 weeks and 3 months postprocedure. Patency after 2 weeks, 6 months, and 12 months was 93%, 67%, and 64% for TASC A lesions, 83%, 31%, and 31% for TASC B lesions, and 100%, 50%, and 33% for TASC C lesions, respectively. In conclusion, cryoplasty has good immediate success rates and patency rates similar to the results of conventional PTA in the literature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

C-arm Cone Beam Computed Tomographic Needle Path Overlay for Fluoroscopic-Guided Placement of Translumbar Central Venous Catheters

C-arm cone beam computed tomography is an advanced 3D imaging technology that is currently available on state-of-the-art flat-panel-based angiography systems. The overlay of cross-sectional imaging information can now be integrated with real-time fluoroscopy. This overlay technology was used to guide the placement of three percutaneous translumbar inferior vena cava catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D Stereoscopic Visualization of Fenestrated Stent Grafts

The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation

Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 {+-} 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic and computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 {+-} 8% before the procedure to 15.7 {+-} 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stent-Graft Treatment for Bleeding Superior Mesenteric Artery Pseudoaneurysm After Pancreaticoduodenectomy

We report two cases of intraperitoneal bleeding from superior mesenteric artery (SMA) pseudoaneurysm after pancreaticoduodenectomy for pancreatic head carcinoma. In both cases, a stent-graft was deployed on the main SMA to exclude pseudoaneurysm and to preserve blood flow to the bowel. Bleeding stopped after the procedure. One patient was able to be discharged but died from carcinoma recurrence 4 months later. The other patient died of sepsis and stent-graft infection 5 months later. These patients remained free of intraperitoneal rebleeding during the follow-up period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stroke Secondary to Aseptic Meningitis After Endovascular Treatment of a Giant Aneurysm with Parent Artery Occlusion

Aseptic meningitis related to hydrogel-coated coils is a known complication, but it is extremely rare after platinum bare coil aseptic meningitis. Here we report the development of aseptic meningitis causing brain stem and cerebellar infarct in a patient with a giant aneurysm treated with bare platinum coils. We conclude that aneurysm size is an important factor affecting the occurrence of aseptic meningitis associated with stroke.

62 RADIOLOGY AND NUCLEAR MEDICINE↗