Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PRODUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

The RHIC Optically-Pumped Polarized H{sup -} Ion Source

The depolarization factors in the multi-step spin-transfer polarization technique and basic limitations on maximum polarization in the OPPIS (Optically-Pumped Polarized H{sup -} Ion Source) are discussed. Detailed studies of polarization losses in the RHIC OPPIS and the source parameters optimization resulted in the OPPIS polarization increase to 86-90%. This contributed to increasing polarization in the AGS and RHIC to 65{approx}70%.

43 PARTICLE ACCELERATORS↗

Polarized Radioactive Ion Beams

Radioactive beams are short-lived heavy-ion beams which can be polarized using inflight techniques. Methods commonly used are based on tilted foils or recoil angle selection at high energies, or laser optical pumping at low energies. Tilted foils are a universal method typically producing nuclear polarization of a few percent. Recoil selection produces appreciable polarization under some conditions. Collinear optical pumping of alkali beams typically produces much higher polarization. The latter technique and its extension to the alkaline earths, noble gases and other elements are described.

43 PARTICLE ACCELERATORS↗

R and D Topics for Neutrino Factory Acceleration

The muons in a neutrino factory must be accelerated from the energy of the capture, phase rotation, and cooling systems (around 120 MeV kinetic energy) to the energy of the storage ring (around 25 GeV). This is done with a sequence of accelerators of different types: a linac, one or more recirculating linear accelerators, and finally one or more fixed field alternating gradient accelerators (FFAGs). I discuss the R and D that is needed to arrive at a complete system which we can have confidence will accelerate the beam and for which we can obtain a cost estimate.

43 PARTICLE ACCELERATORS↗

Nuclear astrophysics studies by SAMURAI spectrometer in RIKEN RIBF

SAMURAI is a spectrometer which is now being constructed at RIKEN RI Beam Factory. This spectrometer is characterized by a large angular-and momentum-acceptance enabling, for example, multi-particle coincidence measurements. Here brief descriptions of SAMURAI spectrometer and physics topics relevant to nuclear astrophysics are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-High Gradient S-Band Linac for Laboratory And Industrial Applications

A strong demand for high gradient structures arises from the limited real estate available for linear accelerators. RadiaBeam Technologies is developing a Doubled Energy Compact Accelerator (DECA) structure: an S-band standing wave electron linac designed to operate at accelerating gradients of up to 50 MV/m. In this paper, we present the radio-frequency design of the DECA S-band accelerating structure, operating at 2.856 GHz in the {pi}-mode. The structure design is heavily influenced by NLC collaboration experience with ultra high gradient X-band structures; S-band, however, is chosen to take advantage of commonly available high power S-band klystrons.

43 PARTICLE ACCELERATORS↗

T2K

The project status of T2K is presented. T2K will search for the {nu}{sub {mu}}{yields}{nu}{sub e} oscillation using the high intensity {nu}{sub {mu}} beam produced by J-PARC. The experimental setup and the prospects are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

J-PARC Accelerator

The Japan Proton Accelerator Research Complex (J-PARC) is under construction in Tokai site. The linac beam commissioning started last fall, while the beam commissioning of the 3-GeV Rapid-Cycling Synchrotron (RCS) will start this fall. The status of the J-PARC accelerator is reported with emphasis on the technical development accomplished for the J-PARC.

43 PARTICLE ACCELERATORS↗

Development of Radioactive Ion Beam Purification by Selective Adsorption at the HRIBF

In the past decades many techniques have been developed to reduce isobaric contaminations in ISOL (Isotope Separation On-Line) beams. Another promising method to achieve improved selectivity is employing surface effects in the transfer line between target container and ion source. Thus adsorption materials with suitable atomic structure and polarity can lead to a high chemical selectivity. The principle of selective adsorption has already been employed successfully in the past. Quartz transfer lines are applied on-line at ISOLDE and have been shown to reduce Rb contaminations by 5 orders of magnitude. Since quartz is the only compound that has been tested yet we plan to conduct a broad on-line study of the adsorption behavior of various elements on a range of materials. For testing at the On-Line Test Facility at the Holifield Radioactive Ion Beam Facility (HRIBF) a special target-ion source unit with a variable-temperature transfer line has been constructed in collaboration with the ISOLDE technical group. Based on the design of the ISOLDE prototype unit it was modified to match the unique capabilities of the OLTF. Preliminary results of on-line tests are presented.

43 PARTICLE ACCELERATORS↗

Wakefields in photonic accelerator structures

Control and manipulation of properties - such as vacuum modal confinement, spatial harmonic content, phase velocity, and group velocity - are reasons why an all-dielectric beam-driven accelerator would be expected to benefit by borrowing from the field of optical bandgap photonics. We outline the general conditions for coherent Cerenkov radiation in a photonic crystal, illustrated by three examples: two Bragg mirrors separated by a vacuum gap, a woodpile with a linear waveguide channel, and a stack of photonic slabs having a planar waveguide channel.

43 PARTICLE ACCELERATORS↗

NIO1 diagnostics

The radio frequency ion source NIO1, jointly developed by Consorzio RFX and INFN-LNL, will generate a 60kV-135mA hydrogen negative ion beam, composed of 9 beamlets over an area of about 40 × 40 mm{sup 2}. This experiment will operate in continuous mode and in conditions similar to those foreseen for the larger ion sources of the Neutral Beam Injectors for ITER. The modular design of NIO1 is convenient to address the several still open important issues related to beam extraction, optics, and performance optimization. To this purpose a set of diagnostics is being implemented. Electric and water cooling plant related measurements will allow monitoring current, pressure, flow, and temperature. The plasma in the source will be characterized by emission spectroscopy, cavity ring-down and laser absorption spectroscopy. The accelerated beam will be analyzed with a fast emittance scanner, its intensity profile and divergence with beam emission spectroscopy and visible tomography. The power distribution of the beam on the calorimeter will be monitored by thermocouples and by an infrared camera. This contribution presents the implementation and initial operation of some of these diagnostics in the commissioning phase of the experiment, in particular the cooling water calorimetry and emission spectroscopy.

43 PARTICLE ACCELERATORS↗

Reduction of beam current noise in the FNAL magnetron ion source

The new FNAL Injector Line with a circular dimple magnetron ion source has been operational since December of 2012. Since the new injector came on line there have been variations in the H- beam current flattop observed near the downstream end of the Linac. Several different cathode geometries including a hollow cathode suggested by Dudnikov [1] were tried. Previous studies also showed that different mixtures of hydrogen and nitrogen had an effect on beam current noise [2]. We expanded on those studies by trying mixtures ranging from (0.25% nitrogen, 99.75% hydrogen) to (3% nitrogen, 97% hydrogen). The results of these studies in our test stand will be presented in this paper.

43 PARTICLE ACCELERATORS↗

SU-E-T-425: Feasibility of Establishing a National Postal Dosimetry System Using EBT3 Gafchromic Film

Purpose: To evaluate the performance of a postal dosimeter consisting of EBT3 films and a miniature Lucite phantom to be used for photon beams output audits for mega-voltage photon beams across the Saudi Arabia. Methods: Two batches of EBT3 films were calibrated in 5 mega-voltage photon beams with energies ranging between 6 MV and 18 MV in the dose range between 0 to 4 Gy. A 4×4×20 cm{sup 3} lucite phantom was constructed to be used as an irradiation phantom. The lucite irradiation phantom consists of two parts and allows for embedding a 2.5×2.0 cm{sup 2} EBT3 film at 8.9 cm depth. Factors that convert the dose measured in the lucite irradiation phantom at 8.9 cm depth to the dose at 10 cm depth in water for 10×10 cm{sup 2} field for different photon energies were calculated using the dosxyznrc/EGSnrcMP user code. The performance of the proposed postal dosimeter was tested in 17 different photon beams across 4 radiotherapy centres in Saudi Arabia. The outputs of the 17 beams are monitored by either the International Atomic Energy Agency or by the Radiological Physics Centre. Results: For the 17 photon beams, the average of the ratios of measured to stated outputs was 1.01 ± 0.02 and with a maximum ratio of 1.05. Conclusion: The results of our work indicate that the proposed postal dosimetry system can be used for national auditing of outputs for mega-voltage photon beams. The service can be offered to other national radiotherapy centres or to a be used for credentialing of centres participating in national trials.

60 APPLIED LIFE SCIENCES↗

SU-E-T-506: Intercomparison Study On Small Field Output Factor Measurements

Purpose In radiotherapy, uncertainties due to small field measurements (SFM) introduce systematic errors to the treatment process and the development of new dosimeters for quality assurance programs is a challenge. In this work we analyze the behavior of seven detectors measuring output factors of 6MV photon beam. Methods The dosimeters employed are: a single cristal diamond detector (SCCD) developed at the University of Rome Tor Vergata, a silicon diode developed within the project MAESTRO, a IBA Razor silicon diode, A1SL and A26 Exradin ion chambers, an EBT3 Gafchromic film and the Exradin W1 Scintillator.Diamond sensitive volume is a cylinder 2.2mm in diameter and 1μm thick. MAESTRO diode is 2×2mm2 active area. Razor sensitive volume is a cylinder 0.6 mm in diameter and 0.02 mm thick. A16 and A1Sl have a collecting volume of 0,015cc and 0,053cc. The W1 is an optical fiber with an active volume of 0.002cc. All measurements were performed in a water phantom, with detector positioned at the isocenter (SSD=90cm, d=10cm), MAESTRO diode being sandwiched in solid water to obtain an equivalent experimental setup. Results These measurements are challenging due to the absence of charged particle equilibrium conditions, detector size and positioning problems. They are in good agreement among each other, especially GAF, Razor, W1 and SCDD. Maximum deviations reported are related to the field 0.8×0.8cm2 for MAESTRO and chambers data with respect to EBT3: around 15% (A1SLvsEBT3), 16% (MAESTROvsEBT3). Razor and W1 show a deviation around 3% with respect to SCDD. Conclusion In this work measurements made with a variety of detectors are compared. These study show the possibility to choose different detectors for SFM and that smaller ion chambers are still not competitive with solid state detectors. Silicon, diamond and optical fiber dosimeters show a similar behavior with minor discrepancies for the smallest field.

60 APPLIED LIFE SCIENCES↗

Polarized H{sup -} and D{sup -} Beams at COSY/Juelich

By advancing the components of the polarized negative ion source the number of polarized particles for injection into the cyclotron injector of the cooler synchrotron COSY at the IKP of the Forschungszentrum Juelich has been increased, since 2000, by a factor of three to 5.5x10{sup 12} H{sup -} ions, delivered in a 20 milliseconds pulse with a repetition rate of 2 seconds. This report sums up briefly the characteristics of the ion source in its present mode of operation and describes the achievements towards higher beam intensities as well as for providing polarized H{sup -} and D{sup -} beams with high reliability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Open Cavity Solutions to the rf in Magnetic Field Problem

It has been observed that breakdown in an 805 MHz pill-box cavity occurs at much lower gradients as an external axial magnetic field is increased. This effect was not observed with on open iris cavity. It is proposed that this effect depends on the relative angles of the magnetic and maximum electric fields: parallel in the pill-box case; at an angle in the open iris case. If so, using an open iris structure with solenoid coils in the irises should perform even better. A lattice, using this principle, is presented, for use in 6D cooling for a Muon Collider. Experimental layouts to test this principle are proposed.

43 PARTICLE ACCELERATORS↗

Characterization of a Surface-Flashover Ion Source with 10-250 ns Pulse Widths

As a step towards developing an ultra compact D-D neutron source for various defense and homeland security applications, a compact ion source is needed. Towards that end, we are testing a pulsed, surface flashover source, with deuterated titanium films deposited on alumina substrates as the electrodes. An electrochemically-etched mask was used to define the electrode areas on the substrate during the sputtered deposition of the titanium films. Deuterium loading of the films was performed in an all metal-sealed vacuum chamber containing a heated stage. Deuterium ion current from the source was determined by measuring the neutrons produced when the ions impacted a deuterium-loaded target held at -90 kV. As the duration of the arc current is varied, it was observed that the integrated deuteron current per pulse initially increases rapidly, then reaches a maximum near a pulse length of 100 ns.

43 PARTICLE ACCELERATORS↗

PRESENT STATUS OF CHARGE-BREEDING IN KEKCB AT TRIAC

We report a recent experiment about the measurement of wall distribution of ions externally injected for charge-breeding in an electron cyclotron resonance (ECR) ion source. The ions, radioactive and singly charged {sup 111}In, were injected into the ECR ion source (ECRIS) for breeding their charge states at the Tokai Radioactive Ion Accelerator Complex (TRIAC). The residual radioactivity on the wall of the ECR plasma chamber of the source was measured, giving a two-dimensional distribution of the ions failed to be re-extracted during charge breeding. The distribution was decomposed, according to azimuthal symmetry, into three components, asymmetric, 120-degree symmetric, and isotropic ones, whose origins were qualitatively discussed for clarifying ion-losses in the course of charge breeding in ECRIS.

43 PARTICLE ACCELERATORS↗