Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Improved design of proton source and low energy beam transport line for European Spallation Source

The design update of the European Spallation Source (ESS) accelerator is almost complete and the construction of the prototype of the microwave discharge ion source able to provide a proton beam current larger than 70 mA to the 3.6 MeV Radio Frequency Quadrupole (RFQ) started. The source named PS-ESS (Proton Source for ESS) was designed with a flexible magnetic system and an extraction system able to merge conservative solutions with significant advances. The ESS injector has taken advantage of recent theoretical updates and new plasma diagnostics tools developed at INFN-LNS (Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare). The design strategy considers the PS-ESS and the low energy beam transport line as a whole, where the proton beam behaves like an almost neutralized non-thermalized plasma. Innovative solutions have been used as hereinafter described. Thermo-mechanical optimization has been performed to withstand the chopped beam and the misaligned focused beam over the RFQ input collimator; the results are reported here.

43 PARTICLE ACCELERATORS↗

Integration of the full-acceptance detector into the JLEIC

For physics requirements, the JLEIC (Jefferson Lab Electron Ion Collider) has a full-acceptance detector, which brings many new challenges to the beam dynamics integration. For example, asymmetric lattice and beam envelopes at interaction region (IR), forward detection, and large crossing angle with crab dynamics. Also some common problems complicate the picture, like coupling and coherent orbit from detector solenoid, high chromaticity and high multipole sensitivity from low beta-star at interaction point (IP), collision mode with different energy and ion species. Meanwhile, to get a luminosity level of a few 1033 cm-2sec-1, small ?* are necessary at the IP, which also means large ? in the final focus area, chromaticity correction sections, etc. This sets a constraint on the field quality of magnets in large beta areas, in order to ensure a large enough dynamic aperture (DA). In this context, limiting multipole components of magnets are surveyed to get a standard line. And continuously, multipole magnets as dedicated correctors are studied to provide semi-local corrections of specific multipole components beyond the standard line. This report will mention those contents.

Wei, G.H.↗

SU-E-T-499: Initial Developments of An OpenCL-Based Cross-Platform Monte Carlo Dose Engine for Carbon Ion Therapy

Purpose Dose calculation is of critical importance for carbon ion therapy. Monte Carlo (MC) simulation is considered to be the most accurate method for calculation of absorbed dose and of all the more fundamental physical quantities related to biological effects. The long computation time, however, limits its routine clinical applications. We have recently started developing a fast MC package, gCMC for carbon therapy on a parallel processing platform, e.g. GPU, aiming at achieving sufficient efficiency to enable MC in clinically important tasks. This abstract reports our progress. Methods gCMC was developed in OpenCL environment. Our initial developments focused on water material. gCMC supported carbon ion transport in the energy range of 1–450 MeV/u. A Class II condensed history algorithm was implemented for charged particle transport simulations with stopping power computed via Bethe-Bloch equation. Energy straggling and multiple scattering were modeled. Total cross section of nuclear interaction was extracted from Geant4. At present, nuclear interaction events were sampled but transports of secondary particles were not included. Results We tested cases with a homogeneous water phantom and a pencil carbon ion beam with energy of 200–400 MeV/u. When only electro-magnetic channel was included, dose/fluence difference between gCMC and Geant4 results averaged within 10% isodose line was <0.5% of the maximum dose/fluence. After enabling nuclear interactions without transporting secondary particles, dose and fluence agreed with the corresponding results computed by Geant4 with <1% difference. Due to the support for multiple platforms of OpenCL, gCMC was executable on NVidia and AMD GPUs, and Intel CPUs. It took ∼50 sec to transport 107 200MeV/u source carbon ions on an NVidia Titan GPU card. Conclusion Preliminary studies have demonstrated the accuracy and efficiency of gCMC. With further developments in near future, gCMC will potentially achieve clinically acceptable fast and accurate MC simulations for carbon ion therapy.

60 APPLIED LIFE SCIENCES↗

Measurement realities of current collection in dynamic space plasma environments

Theories which describe currents collected by conducting and non-conducting bodies immersed in plasmas have many of their concepts based upon the fundamentals of sheath-potential distributions and charged-particle behavior in superimposed electric and magnetic fields. Those current-collecting bodies (or electrodes) may be Langmuir probes, electric field detectors, aperture plates on ion mass spectrometers and retarding potential analyzers, or spacecraft and their rigid and tethered appendages. Often the models are incomplete in representing the conditions under which the current-voltage characteristics of the electrode and its system are to be measured. In such cases, the experimenter must carefully take into account magnetic field effects and particle anisotropies, perturbations caused by the current collection process itself and contamination on electrode surfaces, the complexities of non-Maxwellian plasma distributions, and the temporal variability of the local plasma density, temperature, composition and fields. This set of variables is by no means all-inclusive, but it represents a collection of circumstances guaranteed to accompany experiments involving energetic particle beams, plasma discharges, chemical releases, wave injection and various events of controlled and uncontrolled spacecraft charging. Here, an attempt is made to synopsize these diagnostic challenges and frame them within a perspective that focuses on the physics under investigation and the requirements on the parameters to be measured. Examples include laboratory and spaceborne applications, with specific interest in dynamic and unstable plasma environments.

Szuszczewicz, Edward P.↗

Development of the Low Granularity Pair Spectrometer counters in Hall D at JLab

The pair spectrometer in the photon beam line of Hall D at JLab is designed to monitor the stability of photon flux and the relative tagging efficiency of the photon tagger via a well known electron-positron pair production measurement. The pair spectrometer consists of a thin foil converter, a dipole magnet, and two identical left and right arm detector packages. Each detector package covers the electron or position energy from 3 GeV to 6.25 GeV. It consists of a front detector array for fine position resolution and rear scintillating hodoscopes to provide fast timing to form the pair production trigger. This presentation will focus on the construction and testing of the Low-Granularity Pair Spectrometer counters.

Dzbenski, Nathan↗

A muon–ion collider at BNL: The future QCD frontier and path to a new energy frontier of μ + μ – colliders

In this work, we propose the development and construction of a novel muon–ion collider (MuIC) at Brookhaven National Laboratory (BNL) in the USA as an upgrade to succeed the electron–ion collider (EIC) that is scheduled to commence in the early 2030s, by a joint effort of the nuclear and particle physics communities. The BNL facility could accommodate a muon storage beam with an energy up to about 1 TeV with existing magnet technology. When collided with a 275 GeV hadron beam, the MuIC center-of-mass energy of about 1 TeV will extend the kinematic coverage of deep inelastic scattering physics at the EIC (with polarized beams) by more than an order of magnitude in Q 2 and x, opening a new QCD frontier to address many fundamental scientific questions in nuclear and particle physics. This coverage is comparable to that of the proposed Large Hadron–Electron Collider (LHeC) at CERN, but with complementary lepton and hadron kinematics, ion species, and beam polarization. Additionally, the development of a MuIC at BNL will focus the worldwide R&D efforts on muon collider technology and serve as a demonstrator toward a future muon–antimuon collider at O(10) TeV energy, which is an attractive option to reach the next high energy frontier in particle physics at an affordable cost and a smaller footprint than a future circular hadron collider. We discuss here the possible design parameters of the MuIC, kinematic coverage, science cases, and detector design considerations including resolution estimates on DIS kinematic variables. A possible road map toward the future MuIC and muon–antimuon colliders is also presented.

43 PARTICLE ACCELERATORS↗

Laser entrance window transmission and reflection measurements for preheating in magnetized liner inertial fusion

Laser-driven magnetized liner inertial fusion (MagLIF) is being developed on the OMEGA Laser System to study scaling. MagLIF targets require a preheat laser entrance window that can hold the gas in the target yet allow sufficient laser energy to enter the gas. For OMEGA MagLIF targets, 1.8-μm-thick polyimide foils were found to be sufficient to hold a fuel pressure of up to 14 atm. Transmission and reflection of an OMEGA beam incident on such foils were measured with a calorimeter and time-resolved spectrometers for 2.5-ns square-shaped pulses, with energies from 60 to 200 J, focused to intensities from 0.65 to 2.2 × 10 14 W/cm 2 . The laser energy transmitted in every case exceeded that required to achieve the goal of preheating the gas to 100 eV. The time-resolved measurements showed an initial period with very low, decreasing transmission, the duration of which decreased with increasing intensity, followed by a rapid transition to full transmission, accompanied by brief sidescattering of the transmitted light with a significant red shift. Reflection was always negligible. Two-dimensional radiation–hydrodynamic simulations, using 3-D ray tracing with inverse bremsstrahlung energy deposition, did not capture the rapid transition to full transmission, showing instead a slow increase in transmission, without significant sidescatter or red shift. Finally, we propose that full transmission is achieved by relativistic self-focusing, enhanced by focusing related to the electron density profile that forms, followed by a ponderomotive blowout of the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-AB-BRA-12: Experimental Results From the First High-Field Inline MRI-Linac

Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid MRI-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-Linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-Linac system. This work describes our experimental results from the first high-field inline MRI-Linac. Methods: A 1.5 Tesla magnet (Sonata, Siemens) was located in a purpose built RF cage enabling shielding from and close proximity to a linear accelerator with inline orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multi-leaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-Linac experiments was performed to investigate: (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array and; (3) electron focusing measured using GafChromic film. Results: (1) The macropodine phantom image quality with the beam on was almost identical to that with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background noise when the radiation beam was on. (3) Film measurements demonstrated electron focusing occurring at the center of the radiation field. Conclusion: The first high-field MRI-Linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field in-line MRI-Linac and study a number of the technical challenges and solutions. Supported by the Australian National Health and Medical Research Council, the Australian Research Council, the Australian Cancer Research Foundation and the Health and Hospitals Fund.

60 APPLIED LIFE SCIENCES↗

FULL ACCEPTANCE INTERACTION REGION DESIGN OF JLEIC

Nuclear physics experiments envisioned at a proposed future Electron-Ion Collider (EIC) require high luminosity of 10^33-10^34 cm^-2s^-1 and a full-acceptance detector capable of reconstruction of a whole electron-ion collision event. Due to a large asymmetry in the electron and ion momenta in an EIC, the particles associated with the initial ion tend to go at very small angles and have small rigidity offsets with respect to the initial ion beam. They are detected after they pass through the apertures of the final focusing quadrupoles. Therefore, the apertures must be sufficiently large to provide the acceptance required by experiments. In addition, to maximize the luminosity, the final focusing quadrupoles must be placed as close to the interaction point as possible. A combination of these requirements presents serious detection, optics and engineering design challenges. We present a design of a full-acceptance interaction region of Jefferson Lab Electron-Ion Collider (JLEIC). The paper presents how this design addresses the above requirements up to an ion momentum of 200 GeV/c. We summarize the magnet parameters, which are kept consistent with the Nb-Ti superconducting magnet technology.

Morozov, V.S.↗

Reducing beta functions in the NSLS-II long straight section for NEXT-III beamlines

The NSLS-II Experimental Tools III (NEXT-III) Project with the goal of building 8-12 new beamlines is ongoing. We were requested to explore the possibility of modifying the long straight section in Cell 26 to accommodate two new undulators for Advanced Nanoscale Imaging (ANI) Beamline and Tender X-ray Nanoprobe (TXN) Beamline. The scope of work includes: linear lattice matching; confirmation of the minimum ID gaps consistent with beam stay-clear limitations; calculation of the X-ray brightness; optimization of the dynamic aperture and momentum acceptance; multi-particle tracking to confirm the injection efficiency does not deteriorate significantly. The beam simulations have to be done using the most recent NSLS-II lattice model with all present insertion devices and realistic magnet errors, misalignments, and apertures. Originally two lattice options were considered for the assessment:1) with single -minimum beta functions and 2) NSLS-II with double-minimum beta functions. However, since the beamlines are not interested in the reduction of the horizontal beta function, just the vertical one, we decided to stop considering the single-minimum option because the current vertical beta is already low (3.3m) and further reducing it at the straight section center can increase it too much at the edge of a long ID, and limit the beam stay-clear. So, this report is focused on the double mini-beta scheme only.

43 PARTICLE ACCELERATORS↗

Measurement of the anomalous spin precession frequency $\omega_\alpha$ in the Muon g-2 experiment at Fermilab

The Muon $g-2$ Experiment at Fermilab aims to measure the muon magnetic moment anomaly, $a_{\mu} = (g-2)/2$, with a final accuracy of 0.14 parts per million (ppm). A $3.1$-GeV muon beam is injected into a storage ring of $14\,$m diameter, in the presence of a $1.45\,$T magnetic field. The anomaly $a_\mu$ can be extracted by accurately measuring the anomalous muon spin precession frequency $\omega_a$, based on the arrival time distribution of decay positrons observed by $24$ calorimeters, and the magnetic field. In 2023, the experiment published its second result based on the two datasets Run-2 and Run-3, reaching the unprecedented sensitivity of $0.21\,$ppm --- a factor $\sim2.2$ improvement since its first result published in 2021, based on the first dataset (Run-1). In this paper, we will focus on the measurement of the $\omega_a$ frequency, describing the techniques and major sources of systematic uncertainty in the 2023 publication, and outlining the improvements since the 2021 result. We will also cover the status of the ongoing $\omega_a$ analysis for the last three datasets, collected from 2020 to 2023, along with the projected uncertainties on the final Muon $g-2$ measurement at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of basic physical parameters to control plasma meniscus and beam halo formation in negative ion sources

Our previous study shows that the curvature of the plasma meniscus causes the beam halo in the negative ion sources: the negative ions extracted from the periphery of the meniscus are over-focused in the extractor due to the electrostatic lens effect, and consequently become the beam halo. In this article, the detail physics of the plasma meniscus and beam halo formation is investigated with two-dimensional particle-in-cell simulation. It is shown that the basic physical parameters such as the H{sup −} extraction voltage and the effective electron confinement time significantly affect the formation of the plasma meniscus and the resultant beam halo since the penetration of electric field for negative ion extraction depends on these physical parameters. Especially, the electron confinement time depends on the characteristic time of electron escape along the magnetic field as well as the characteristic time of electron diffusion across the magnetic field. The plasma meniscus penetrates deeply into the source plasma region when the effective electron confinement time is short. In this case, the curvature of the plasma meniscus becomes large, and consequently the fraction of the beam halo increases.

36 MATERIALS SCIENCE↗

Discovery of Dielectric Response and Forces in Sub-Nanoscale Objects (Final Technical Report)

This is the final technical report for DOE Award DE-SC0005132 entitled “Discovery of Dielectric Response and Forces in Sub-Nanoscale Objects.” This award originated on August 15, 2010 with Principle Investigator Prof. Phil Batson of Rutgers, The State University of New Jersey. Prof. Batson transitioned to Professor Emeritus status on January 31, 2023. At that time PI status was transferred to Prof. Robert Bartynski of the Department of Physics and Astronomy at Rutgers, The State University of New Jersey, and Director of the Rutgers Laboratory for Surface Modification. The central theme of the research performed under this award is develop and refine a NION aberration-corrected Scanning Transmission Electron Microscope to attain atomic spatial resolution and sub 10meV energy resolution in electron energy loss spectroscopy (EELS) performed on the transmitted electron beam. These capabilities allow examination of the excitation properties (primarily plasmonic and vibrational [ie., phonons] of nanoscale objects when excited with a highly-localized (~ Angstrom-scale) high energy (~ 60 keV) electron beam. Direct excitations (i.e., the response to electrons impinging directly on the sample) as well as excitations in response to the dynamic electric (and magnetic!) fields of an aloof electron beam (i.e., a beam that is close to but displaced from the target) have been studied. Our experimental work has benefited greatly from close collaborations with theoretical colleagues, but at Rutgers and from around the world, providing a much more complete understanding of the observed phenomena and suggesting avenues for further study and practical applications. This report summarizes the technical and scientific achievements accomplished during the entire award period. More extensive details are available in the Progress Reports that have already been filed with the Department of Energy. The report is divided into six sections. The first four sections focus on exploring, developing and understanding several unique capabilities and phenomena discovered and accessible owing to the high spatial- and energy-resolution we have been able to achieve. The latter two sections focus on applications of the STEM’s novel capabilities to study atomic- and nanometer-scale properties of solids, as well as broader applications to advanced and bio-materials.

47 OTHER INSTRUMENTATION↗

Ion velocity distributions in the vicinity of the current sheet in Earth's distant magnetotail

Observations of the three-dimensional velocity distributions of positive ions and electrons have been recently gained for the first time in Earth's distant magnetotail with the Galileo and Geotail spacecraft. For this brief discussion of these exciting results the focus is on the overall character of the ion velocity distributions during substorm activity. The ion velocity distributions within and near the magnetotail current sheet are not accurately described as convecting, isotropic Maxwellians. The observed velocity distributions are characterized by at least two robust types. The first type is similar to the 'lima bean'-shaped velocity distributions that are expected from the nonadiabatic acceleration of ions which execute Speiser-type trajectories in the current sheet. The second distribution is associated with the presence of cold ion beams that presumably also arise from the acceleration of plasma mantle ions in the electric and weak magnetic fields in the current sheet. The ion velocity distributions in a magnetic field structure that is similar to that for plasmoids are also examined. Again the velocity distributions are not Maxwellian but are indicative of nonadiabatic acceleration. An example of the pressure tensor within the plasmoid-like event is also presented because it is anticipated that the off-diagonal elements are important in a description of magnetotail dynamics. Thus our concept of magnetotail dynamics must advance from the present assumption of co-moving electron and ion Maxwellian distributions into reformulations in terms of global kinematical models and nonadiabatic particle motion.

Frank, L. A.↗

Compac carbon ion LINAC

The invention provides a method for accelerating protons and carbon ions up to 450 MeV/u in a very compact linac, the method comprising subjecting the particles to a radio frequency quadrupole field to accelerate the particles to at least 3 MeV/u, a drift tube linac (DTL) to an energy of 20 MeV/u, followed by a coupled DTL to 45 MeV/u and finally a high-gradient section made of CCL-type standing wave cavities or negative harmonic traveling wave cavities operating at S-band frequencies and capable of delivering voltage gradients of 40 to 60 MV/m. Focusing the accelerated particles while accelerated to higher energy is provided by appropriately placed constant field permanent magnets and electromagnetic quadrupoles. The compactness and power efficiency of the linac is enabled by using high-gradient structure in the S-band frequencies for lower energy particles than ever before. The low-intensity required for hadron therapy allows the use of small-aperture S-band structures and the operation at very high gradient compared to high-intensity machines for research. Operating with very short sub-microsecond pulses at repetition rates up to 400 Hz allows the fast and flexible beam energy and intensity tuning not provided by existing hadron therapy machines. The designed linac is capable of accelerating ions as heavy as neon to the full 450 MeV/u energy, therefore allowing fast beam switching if different ion sources are installed in the front-end of the linac.

43 PARTICLE ACCELERATORS↗

Dynamics of multiple viscoelastic carbon nanotube based nanocomposites with axial magnetic field

Nanocomposites and magnetic field effects on nanostructures have received great attention in recent years. A large amount of research work was focused on developing the proper theoretical framework for describing many physical effects appearing in structures on nanoscale level. Great step in this direction was successful application of nonlocal continuum field theory of Eringen. In the present paper, the free transverse vibration analysis is carried out for the system composed of multiple single walled carbon nanotubes (MSWCNT) embedded in a polymer matrix and under the influence of an axial magnetic field. Equivalent nonlocal model of MSWCNT is adopted as viscoelastically coupled multi-nanobeam system (MNBS) under the influence of longitudinal magnetic field. Governing equations of motion are derived using the Newton second low and nonlocal Rayleigh beam theory, which take into account small-scale effects, the effect of nanobeam angular acceleration, internal damping and Maxwell relation. Explicit expressions for complex natural frequency are derived based on the method of separation of variables and trigonometric method for the “Clamped-Chain” system. In addition, an analytical method is proposed in order to obtain asymptotic damped natural frequency and the critical damping ratio, which are independent of boundary conditions and a number of nanobeams in MNBS. The validity of obtained results is confirmed by comparing the results obtained for complex frequencies via trigonometric method with the results obtained by using numerical methods. The influence of the longitudinal magnetic field on the free vibration response of viscoelastically coupled MNBS is discussed in detail. In addition, numerical results are presented to point out the effects of the nonlocal parameter, internal damping, and parameters of viscoelastic medium on complex natural frequencies of the system. The results demonstrate the efficiency of the suggested methodology to find the closed form solutions for the free vibration response of multiple nanostructure systems under the influence of magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visualizing the bidirectional optical transfer function for near-field enhancement in waveguide coupled plasmonic transducers

Here, we report visualizations of the bidirectional near-field optical transfer function for a waveguide-coupled plasmonic transducer as a metrology technique essential for successful development for mass-fabricated near-field devices. Plasmonic devices have revolutionized the observation of nanoscale phenomena, enabling optical excitation and readout from nanoscale regions of fabricated devices instead of as limited by optical diffraction. Visualizations of the plasmonic transducer modes were acquired both by local near-field excitation of the antenna on the front facet of a waveguide using the focused electron beam of a scanning electron microscope as a probe of the near-field cathodoluminescence during far-field collection from the back facet of the waveguide, and by local mapping of the optical near-field for the same antenna design using scattering scanning near-field optical microscopy as a probe of the near-field optical mode density for far-field light focused into the back facet of the waveguide. Strong agreement between both measurement types and numerical modeling was observed, indicating that the method enables crucial metrological comparisons of as fabricated device performance to as-modeled device expectations for heat-assisted magnetic recording heads, which can be extended to successful development of future near-field-on-chip devices such as optical processor interconnects.

42 ENGINEERING↗