Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Observational results using the microwave temperature profiler during the Airborne Antarctic Ozone Experiment

The Microwave Temperature Profiler (MTP) measures profiles of air temperature versus altitude. The altitude coverage is about 5 km at a flight altitude of 20 km (66,000 feet), and the profiles are obtained every 14 s. The MTP instrument is installed on NASA's ER-2 aircraft, which flew 13 missions over Antarctica during the Airborne Antarctic Ozone Experiment. Altitude temperature profiles were used to derive potential temperature cross sections. These cross sections have been useful in detecting atmospheric waves. Many wave encounters have been identified as 'mountain waves'. The mountain waves are found to extend from the lowest altitudes measured to the highest (about 24 km). The southern part of the Palmer Peninsula was found to be associated with mountain waves more than half the time. Altitude temperature profiles were also used to measure the lapse rate along the flight track. Lapse rate versus latitude plots do not show significant changes at the ozone hole boundary.

Gary, Bruce L.↗

Intercomparison results for FIFE flux aircraft

Three atmospheric research aircraft were used to explore the atmospheric boundary layer during FIFE: the National Research Council of Canada Twin Otter, the National Center for Atmospheric Research (NCAR) King Air, and the University of Wyoming King Air. The aircraft were used to measure the mean and turbulent structure of the boundary layer and its variation with height, time, and space. These measurements are important to FIFE because they are being used to scale up point surface observations to landscape scales and because they can be used to relate satellite radiance measurements to boundary layer processes. Because the aircraft were used in coordinated flight patterns to investigate changes within and between intensive field campaigns, wing-to-wing intercomparisons were made so that measurements from one aircraft could be related to another. Intercomparisons were flown on 4 days in 1987 and 3 days in 1989. The eddy correlation measurements of the mixed layer fluxes of moisture and sensible heat were of particular interest to FIFE. Sensible heat fluxes agreed within 15 W/sq m and moisture fluxes agreed within 21 W/sq m. Mean wind component differences were within 1.0 m/s, air temperature within 0.3 C, and mixing ratio within 2 g/kg. Standard deviations showed similar good agreement, with mean differences generally less than 0.1 m/s for the wind components and 0.03 C for potential temperature. Intercomparisons between the NCAR King Air and the Twin Otter showed better agreement in 1989 than in 1987. Overall, the results suggest that data from the FIFE boundary layer aircraft will need little correction to account for instrument biases and spurious fluctuations.

Macpherson, J. I.↗

Electrical Thermometers for Aircraft

Electrical thermometers commonly used on aircraft are the thermoelectric type for measuring engine-cylinder temperatures, the resistance type for measuring air temperatures, and the superheat meters of thermoelectric and resistance types for use on airships. These instruments are described and their advantages and disadvantages enumerated. Methods of testing these instruments and the performance to be expected from each are discussed. The field testing of engine-cylinder thermometers is treated in detail.

Peterson, John B↗

High Spatial Resolution Thermal Infrared Remote Sensing Data for Analysis of the Atlanta, Georgia, Urban Heat Island Effect and Its Impacts on the Environment

The twenty-first century is the first "urban century" according to the United Nations Development Program. The focus of cities reflects awareness of the growing percentage of the world's population that lives in urban areas. In environmental terms, cities are the original producers of many of the global problems related to waste disposal, air and water pollution, and associated environmental and ecological challenges. Expansion of cities, both in population and areal extent, is a relentless process. In 2000, approximately 3 billion people representing about 40% of the global population, resided in urban areas. Urban population will continue to rise substantially over the next several decades according to UN estimates, and most of this growth will Occur in developing countries. The UN estimates that by 2025, 60% of the world's population will live in urban areas. As a consequence, the number of"megacities" (those cities with populations of 10 million inhabitants or more) will increase by 100 by 2025. Thus, there is a critical need to understand urban areas and what their impacts are on environmental, ecological and hydrologic resources, as well as on the local, regional, and even global climate. One of the more egregious side effects of urbanization is the increase in surface and air temperatures that lead to deterioration in air quality. In the United States, under the more stringent air quality guidelines established by the U.S. Environmental Protection Agency in 1997, nearly 300 counties in 34 states will not meet these new air quality standards for ground level ozone. Mitigation of the urban heat island (UHI) effect is actively being evaluated as a possible way to reduce ground ozone levels in cities and assist states in improving air quality. Foremost in the analysis of how the UHI affects air quality and other environmental factors is the use of remote sensing technology and data to characterize urban land covers in sufficient detail to quantifiably measure the impact of increased urban heating on air quality. The urban landscape impacts surface thermal energy exchanges that determine development of the UHI. This paper will illustrate how we are using high spatial remote sensing data collected over the Atlanta, Georgia metropolitan area in conjunction with other geographic information, to perform a detailed urban land cover classification and to determine the contribution of these land covers to the urban heat island effect. Also, the spatial arrangement of the land covers and the impact on urban heating from these selected patterns of development are evaluated. Additionally, this paper will show how these data are being used as inputs to improve air quality modeling for Atlanta, including potential benefits from UHI mitigation.

Quattrochi, Dale A.↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Methodology to evaluate design modifications intended to eliminate frosting and high discharge temperatures in air-source heat pumps (ASHPs) in cold climates

Air-source heat pumps (ASHPs) operating in cold climates experience problems with frosting and high refrigerant temperatures. These problems increase energy consumption, and their severity depends on the climatic conditions. In the present paper, a methodology for identifying the prevailing problem between frosting and high discharge temperatures is presented. Three performance indices, the frosting index (FI), the discharge index (DI), and the total loss index (TLI), are proposed to quantify the impacts of frosting and high discharge temperatures on the annual performance of ASHPs in different climatic conditions. The FI and DI show which problem (frosting or high discharge temperature) dominates, and the TLI indicates the combined effect of frosting and high discharge temperatures on the performance of an ASHP. A thermodynamic model of an ASHP coupled with the TRNSYS building simulation tool is used to estimate the performance of an ASHP and the proposed loss indices to estimate the impact of both frosting and high discharge temperatures for 45 cities in Canada. The results can be extended to other parts of the world that experience similar climatic conditions The results reveal that in cities in ASHRAE climatic zones 5 and 6 (classified as cold regions) where the ambient air temperatures are predominantly between -15 °C to 6 °C, ASHPs are heavily impacted by frosting. The problem of high discharge temperatures in ASHPs is predominant in cities in climate zones 7 and 8 (classified as very cold and subarctic regions) where the temperatures are frequently below -20 °C in winter. Among the cities considered, St. John, NL has the highest fraction of heating hours experiencing frosting (90 %), where the annual increase in energy consumption due to frosting is 13.5 % of the annual heating energy consumption. The highest annual increase in energy consumption due to high discharge temperatures is in Isachsen, NU (zone 8), where the increase is 30 % of the annual heating energy consumption. Based on the proposed indices, another index called the performance gain index (PGI) is created, which can be used as a first step to assess the energy-saving potential of design modifications applied to ASHPs to solve the problems of frosting and high discharge temperatures. The PGI will aid in developing climate specific ASHPs. One possible design modification is the use of a two-stage ASHP with an economizer. It is observed that the two-stage ASHP with economizer can mitigate high discharge temperatures and improve performance in very cold and subarctic regions (zones 7 and 8). However, it is not as beneficial in zones 5 and 6, where the impact of high discharge temperatures on performance is minimal and frosting dominates. Finally, a case study, using the PGI to evaluate the economic and environmental effectiveness of a two-stage ASHP with economizer is presented for the city of Saskatoon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Preliminary Study of the Prevention of Ice on Aircraft by the Use of Engine-exhaust Heat

An investigation was made in the N.A.C.A. ice tunnel at air temperatures from 20 degrees to 28 degrees Fahrenheit and at a velocity of 80 miles per hour to determine whether ice formations on a model wing could be prevented by the use of the heat from the engine-exhaust gas. Various spanwise duct systems were tested in a 6-foot-chord N.A.C.A. 23012 wing model. The formation of ice over the entire wing chord was prevented by the direct heating of the forward 10 percent of the wing by hot air, which was passed through leading-edge ducts. Under dry conditions, enough heat to maintain the temperature of the forward 10 percent of the wing at about 200 degrees Fahrenheit above that of the ambient air was required for the prevention of ice formation. The air temperature in the ducts that was necessary to produce these skin temperatures varied from 360 degrees to 834 degrees Fahrenheit; the corresponding air velocities in the duct were 152 and 45 feet per second. Ice formations at the leading edge were locally prevented by air that passed over the interior of the wing surface at a velocity of 30 feet per second and a temperature of 122 degrees Fahrenheit.

Rodert, Lewis A↗

Temperature, Humidity, and Time-Lapse Video Data from the East River Watershed, Water Years 2024 and 2025

This dataset contains time-lapse imagery and distributed measurements of air temperature, relative humidity, dew point, and soil temperature across the East River basin from 3 October 2023 to 8 August 2025. Instruments were deployed at 19 sites as part of the DOE Grant: Seasonal Cycles Unravel Mysteries of Missing Mountain Water organized by Jessica Lundquist (University of Washington), Rosemary Carroll (Desert Research Institute), and Ethan Gutmann (National Center for Atmospheric Research). The data are published to support studies of surface climate or hydrologic processes in complex terrain. Measurements were collected with low-cost data loggers installed 2 m high on evergreen trees or buried just below the soil surface. Time-lapse cameras were deployed at three sites. Imagery from sites AP BONUS and AP5 (Avery Picnic) provides insight into large-scale seasonal snow cover variability. Imagery from site EL2 (Emerald Lake) shows smaller-scale snow patterns across a nearby meadow. Dataset files are organized by site and variable (air measurements, ground measurements, or time-lapse video). Air and ground measurements are packaged in LoggerData.zip, and time-lapse imagery is compiled into short videos stored in TimelapseVideos.zip. File-level metadata contains details for each file included in the dataset. A data dictionary provides units and descriptions for column or row names in all files. The locations metadata file describes site characteristics, locations, and associated GPS methods.

54 ENVIRONMENTAL SCIENCES↗

Summertime Near-Surface Temperature Biases Over the Central United States in Convection-Permitting Simulations

Convection-Permitting Model (CPM) simulations of the Central United States climate for the summer of 2011 are studied to understand the causes of warm biases in 2-m air temperature (T 2m ) and related underestimates of precipitation including that from mesoscale convective systems (MCSs). Based on 10 CPM simulations and 9 coarser-resolution model simulations, we quantify contributions from evaporative fraction (EF) and radiation to the T 2m bias with both types of models overestimating T 2m largely because they underestimate EF. The performance of CPMs in capturing MCS characteristics (frequency, rainfall, propagation) varies. The pre-summer precipitation bias has large correlation with mean summertime T 2m bias but the relationship between summertime MCS mean rainfall bias and T 2m bias is non-monotonic. Analysis of lifting condensation level deficit and convective available potential energy suggests that models with T 2m warm biases and low EF have too dry and stable boundary layers, inhibiting the formation of clouds, precipitation and MCSs. Among the CPMs with differing model formulations (e.g., transpiration, infiltration, cloud macrophysics and microphysics), evidence suggests that altering the land-surface model is more effective than altering the atmospheric model in reducing T 2m biases. In conclusion, these results demonstrate that land-atmosphere interactions play a very important role in determining the summertime climate of the Central United States.

2-m air temperature↗

Continuous sensor suite measurements of weather, energy, soil and flux at four PumpHouse sites at the East River, Colorado

The purpose of this package is to monitor energy and water fluxes using a comprehensive set of sensors integrated on a tripod set up at 4 locations at the East River watershed in Colorado in the Upper Colorado River Basin as part of the Scientific Focus Area (SFA) research led by the Lawrence Berkeley National Lab (LBNL). This is a continuous sensor suite measurements of weather, energy, soil and flux at four East River pumphouse sites (ER-PHS1, ER-PHS2, ER-PHS3 and ER-PHS4) include: (1) soil CO2 concentration, CO2 flux and heat flux from soil surface; (2) photosynthetic active radiation flux at 1 m; (3) incoming/outcoming short and long wave radiation at 1 m, and user calculated net short and long wave radiation; (4) oxygen concentration and surface infrared temperature; (5) soil volumetric water content, temperature, and electrical conductivity at 10, 30, 60, 115 cm depth 115 cm depth; (6) soil matric potential and temperature at 30 cm depth; (7) incoming short wave radiation at 3 m height; (8) rainfall precipitation; (9) lightning strikes and strike distances; (10) wind direction and speed, maximum wind gust at 3 m; (11) air temperature, vapor pressure and barometric pressure at 3 m; (12) X _axis_level and Y_axis_level_(degree), tilt of the ATMOS 41 sensor; (13) maximum rainfall rate; (14) relative humidity sensor temperature at 3 m; (15) internally calculated vapor pressure deficit at 3 m with vapor pressure, relative humidity and sensor temperature measurements; (16) user calculated vapor pressure.These datasets contain data from Oct 11 2019 to March 20, 2020, and new datasets will be updated on annual basis. Files uploaded in Excel and Word, with copies in csv and pdf format.

54 ENVIRONMENTAL SCIENCES↗

Constraining Arctic Climate Projections of Wintertime Warming With Surface Turbulent Flux Observations and Representation of Surface-Atmosphere Coupling

The drivers of rapid Arctic climate change—record sea ice loss, warming SSTs, and a lengthening of the sea ice melt season—compel us to understand how this complex system operates and use this knowledge to enhance Arctic predictability. Changing energy flows sparked by sea ice decline, spotlight atmosphere-surface coupling processes as central to Arctic system function and its climate change response. Despite this, the representation of surface turbulent flux parameterizations in models has not kept pace with our understanding. The large uncertainty in Arctic climate change projections, the central role of atmosphere-surface coupling, and the large discrepancy in model representation of surface turbulent fluxes indicates that these processes may serve as useful observational constraints on projected Arctic climate change. This possibility requires an evaluation of surface turbulent fluxes and their sensitivity to controlling factors (surface-air temperature and moisture differences, sea ice, and winds) within contemporary climate models (here Coupled Model Intercomparison Project 6). The influence of individual controlling factors and their interactions is diagnosed using a multi-linear regression approach. This evaluation is done for four sea ice loss regimes, determined from observational sea ice loss trends, to control for the confounding effects of natural variability between models and observations. The comparisons between satellite- and model-derived surface turbulent fluxes illustrate that while models capture the general sensitivity of surface turbulent fluxes to declining sea ice and to surface-air gradients of temperature and moisture, substantial mean state biases exist. Specifically, the central Arctic is too weak of a heat sink to the winter atmosphere compared to observations, with implications to the simulated atmospheric circulation variability and thermodynamic profiles. Models were found to be about 50% more efficient at turning an air-sea temperature gradient anomaly into a sensible heat flux anomaly relative to observations. Further, the influence of sea ice concentration on the sensible heat flux is underestimated in models compared to observations. The opposite is found for the latent heat flux variability in models; where the latent heat flux is too sensitive to a sea ice concentration anomaly. Lastly, the results suggest that present-day trends in sea ice retreat regions may serve as suitable observational constraints of projected Arctic warming.

turbulent fluxes↗

Giovanni: A System for Rapid Access, Visualization and Analysis of Earth Science Data Online

Collecting data and understanding data structures traditionally are the first steps that a user must take, before the core investigation can begin. This is a time-consuming and challenging task, especially when science objectives require users to deal with large multi-sensor data that are usually in different formats and internal structures. The Goddard Earth Sciences Data and Information Services Center (GES DISC) has created the GES DISC Interactive Online Visualization and ANalysis Infrastructure, Giovanni, to enable Web-based visualization and analysis of satellite remotely sensed meteorological, oceanographic, and hydrologic data sets, without users having to download data. The current operational Giovanni interfaces provide the capability to process a number of important satellite measurements, such as (1) ozone and other trace gases from TOMS, OMI, HALOE, and MLS; (2) air temperature, water vapor, and geopotential height from AIRS; (3) aerosols from MODIS TerrdAqua, and GOCART model; (4) precipitation from TRMM and ground measurements; (5) chlorophyll and other ocean color products from SeaWiFS and MODIS Aqua; and (6) sea surface temperature from MODIS Aqua. Depending on the input data structure, the system provides simple statistical analysis and creates time-averaged area plot, area-averaged time series, animations, Hovmoller latitude vs. time and longitude vs. time plots, as well as vertical profiles. The inter-comparison interfaces allow a user to compare observations from different instruments, to conduct anomaly analysis, and to study basic relationships between physical parameters. Giovanni handles data with different temporal and spatial resolutions and, thus, enables both regional and global long-term climate research and short-term special events investigation, as well as data validations and assessments. Because of its simplicity of usage, Giovanni is powerful and versatile, able to assist a wide range of users, from the discipline scientists conducting preliminary research in various fields, to students in the classroom learning about weather, climate, and other natural phenomena. Giovanni can be accessed from: http://disc. esfc.nasa.gov/techlab/giovanni/index.shtml

Shen, S.↗

Summer temperatures during the last glaciation (MIS 5c to MIS 3) inferred from a 50,000-year chironomid record from Füramoos, southern Germany

There is a sparsity of long, continuous palaeotemperature records for the last glacial period in central Europe, particularly for the interval corresponding to Marine Isotope Stages (MIS) 4 and 3. Here we present a new, ca. 50-thousand year (ka)-long chironomid record from Füramoos, southern Germany, covering the interval from MIS 5a to MIS 3 that we use to examine lake development and then to quantitatively reconstruct mean July air temperatures. Chironomid assemblages with high abundances of taxa such as Polypedilum nubeculosum-type, Microtendipes pedellus-type, Cladopelma lateralis-type and Dicrotendipes nervosus-type imply a shallow-lake setting for the majority of the examined interval, which is corroborated by other aquatic remains such as oribatid mites, Sialidae and Ceratopogonidae. Assemblages from the interval ca. 99 to 80 ka (in the region corresponding to the Brörup Interstadial, Stadial B and early Odderade Interstadial) are dominated by taxa such as Tanytarsus glabrescens-type and Tanytarsus mendax-type and indicate relatively warm temperatures. Assemblages from the interval covering ca. 80 to 54 ka (corresponding to the late Odderade, Stadial C, Dürnten Interstadial and Stadial D) are dominated by taxa such as Sergentia coracina-type and Tanytarsus lugens-type and are typical for cooler conditions. Reconstructed July temperatures for the early Würmian (Brörup to early Odderade; ca. 99–80 ka) are 13–14 °C. Values decline to <10 °C during the late Odderade and Stadial C (ca. 80–77 ka) around the MIS 5a/4 transition. This decrease is coeval with a pronounced decrease in Northern Hemisphere summer insolation. Values stay in the range of 9–11 °C during the Dürnten and Stadial D (ca. 54–74.5 ka) and increase again to 12.5 °C during the Bellamont 1 interstadial (ca. 54–46 ka). Reconstructed July temperatures track changes in arboreal pollen percentages at Füramoos and agree with a summer-temperature decrease during the early to mid-Würmian as reported by other palaeotemperature records from Europe and the North Atlantic. Our chironomid record from Füramoos provides valuable new insights into Würmian climate dynamics in Central Europe, and corroborates other temperature reconstructions from the early to mid-Würmian glacial period.

Chironomids↗

Autoignition characteristics of no. 2 diesel fuel

Parametric tests to map the ignition delay characteristics were conducted at pressures of 3, 4, and 5 atm, inlet air temperatures up to 1150 K and fuel air equivalence ratios ranging from 0.2 to 1.0. Ignition delay times in the range of 6 msec to 60 msec at freestream flow velocities ranging from 10 m/sec to 40 m/sec were obtained. The ignition delay times appeared to correlate with the inverse of pressure and the inverse exponent of temperature.

Tevelde, J. A.↗

Trends in the Southern Hemisphere

The station data of monthly mean sea level pressure, surface air temperature as well as monthly mean upper air rawinsonde observations were used to study the trends in the southern winter (June, July and August) and summer (December, January and February). This study covers the period 1951 to 1981. Most of the surface data have continuous 31 year records, however, for some high latitude stations, both surface and upper air records started in 1957 or even later. The normalized anomaly for a given variable Z is defined as the departure from the 1951 to 1981 grand mean divided by the standard deviation during the same period. To eliminate the large fluctuations in the data, the 1-3-1 smoothing was applied to the time series of normalized anomalies. The trends of monthly mean temperatures and height from the surface to 200 mb level is documented.

Mo, K. C.↗

Processing Tomato Production Is Expected to Decrease By 2050 Due to the Projected Increase in Temperature

The global processing tomato production is concentrated in a small number of regions where climate change will have a significant impact on the future supply. Process-based tomato models project that the production in the three main producing countries (the United States, Italy, and China, representing 65% of global production) will decrease 6% by 2050, compared to the baseline period of 1980-2009. The predicted reduction in processing tomato production is due to a simulated increase in air temperature. Under an ensemble of projected climate scenarios, California and Italy might not be able to sustain the current levels of processing tomato production due to water resources constraints. Cooler producing regions, such as China and the northern parts of California, stand to improve their competitive advantage. The projected environmental changes indicate that the main growing regions of processing tomatoes might change in the coming decades.

Tomato production↗

Heat Transfer in a Superelliptic Transition Duct

Local heat transfer measurements were experimentally mapped using a transient liquid-crystal heat transfer technique on the surface of a circular-to-rectangular transition duct. The transition duct had a length-to-diameter ratio of 1.5 and an exit-plane aspect ratio of 3. The crosssectional geometry was defined by the equation of a superellipse. The cross-sectional area was the same at the inlet and exit but varied up to 15 percent higher through the transition. The duct was preheated to a uniform temperature (nominally 64 C) before allowing room temperature air to be suddenly drawn through it. As the surface cooled, the resulting isothermal contours on the duct surface were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the surface temperature and time data for all points on the duct surfaces during each test. Using this surface temperature-time data together with the temperature of the air flowing through the model and the initial temperature of the model wall, the heat transfer coefficient was calculated by employing the classic one-dimensional, semi-infinite wall heat transfer conduction model. Test results are reported for inlet diameter-based Reynolds numbers ranging from 0.4x106 to 2.4x106 and two grid-generated freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.

Poinsatte, Philip↗

Survival of Snow in the Melting Layer: Relative Humidity Influence

This study quantifies how far snow can fall into the melting layer (ML) before all snow has melted by examining a combination of in-situ observations from aircraft measurements in Lagrangian spiral descents from above through the ML and descents and ascents into the ML, as well as an extensive database of NOAA surface observer reports during the past 50 years. The airborne data contain information on the particle phase (solid, mixed, or liquid), population size distributions and shapes, along with temperature, relative humidity, and vertical velocity. A wide range of temperatures and ambient relative humidities are used for both the airborne and ground-based data. It is shown that an ice bulb temperature of 0°C, together with the air temperature and pressure (altitude), are good first order predictors of the highest temperature snowflakes can survive in the melting layer before completely melting. Particle size is also important, as is whether the particles are graupel or hail. If the relative humidity is too low, the particles will sublimate completely as they fall into the melting layer. Snow as warm as +7°C is observed from aircraft measurements and surface observations. Snow pellets survive to even warmer temperatures. Relationships are developed to represent the primary findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗