Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ATLAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Performance of Michigan sMDT prototype chambers for the HL-LHC ATLAS muon detector upgrade

A new small-diameter Monitored Drift Tube (sMDT) chamber has been developed for the muon spectrometer of the ATLAS experiment to handle the higher collision rates expected at the CERN High Luminosity Large Hadron Collider (HL-LHC). This paper presents measurements of the tracking resolution and hit efficiency of two prototype sMDT chambers constructed at the University of Michigan. Using cosmic-ray muons the sMDT tracking resolution of 103.7 ± 8.1 μm was measured for one chamber and 101.8 ± 7.8 μm for the other, compared with a design resolution of 106 μm. A further tracking resolution improvement to 83.4 ± 7.8 μm was obtained by using new high-gain readout electronics which will be added for HL-LHC. An average tracking efficiency of (98.5 ± 0.2)% was found for both chambers. The methodology used to determine the detector tracking resolution and efficiency, including reconstruction of sMDT data and a Geant4 simulation of the test chamber, is presented in detail.

43 PARTICLE ACCELERATORS↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗

Construction and testing of sMDT tubes at the University of Michigan for the ATLAS Muon Spectrometer upgrade

This paper reports on the design and construction of infrastructure and test stations for small-diameter monitored drift tube (sMDT) assembly and testing at the University of Michigan (UM) to prepare for the ATLAS Muon Spectrometer upgrade for the high-luminosity program of the Large Hadron Collider. Procedures of the tube assembly and quality assurance and control (QA/QC) tests are described in detail. More than 99% of the tubes meet the tube QA/QC specifications based on 2100 tubes built at UM. The UM test stations are also used for QA/QC testing on the tubes constructed at Michigan State University. Furthermore, these tubes are being used to construct the sMDT chambers which will replace the current MDT chambers of the barrel inner station of the Muon Spectrometer.

47 OTHER INSTRUMENTATION↗

Electrical performances of pre-production staves for the ATLAS ITk Strip Detector Upgrade

The ATLAS experiment is currently preparing for an upgrade of the inner tracking detector for the High-Luminosity LHC. The new tracker, ITk, employs an all-silicon detector with outer strip layers. The building block of the ITk strip barrel is the stave which consists of a low-mass support structure hosting the common electrical, optical and cooling services as well as 28 silicon modules. In this contribution, we outline the challenging aspects of the stave pre-production testing phase at Brookhaven National Laboratory. Here, the electrical characterization of these staves, hosting the final design of all ASICs, will be discussed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and testing of the powerboard for ATLAS ITk Strip barrel modules

The upgrade of the ATLAS ITk strips detector for HL-LHC will employ a custom PCB (powerboard) for on-module DC-DC conversion, HV switching, and monitoring. Production of about 14100 of such PCBs with high reliability is a big challenge. In this paper we will present the production procedure and quality control (QC) testing system for the powerboards to be installed on ITk Strip barrel modules. During production, about 150 powerboards will be produced every week. Each powerboard will need to pass QC tests before they are assembled to module. The QC tests include thermal cycling between -35 °C and 40 °C, soak test (continuous running of DC-DC converter at high load at 20 °C), and basic functionality and characterization electrical tests of the low voltage (LV), high voltage (HV), and monitoring functions of the powerboard. A custom QC test system is described, which is based on a reusable PCB (active board) with all testing circuits, a one-time powerboard carrier card, and a Z-turn SoC board which hosts and runs the testing program. The production procedure and QC test system has been tested with 400 powerboards during pre-production, and the system has been proven ready for production with the desired testing program, speed, safety, and cost. Performance and typical failures of powerboards observed during the QC test of pre-production powerboards is also presented.

47 OTHER INSTRUMENTATION↗

Construction of precision sMDT detector for the ATLAS Muon Spectrometer upgrade

Here, this paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 μm. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 ± 7 μm with an average detection efficiency above 99%. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.

47 OTHER INSTRUMENTATION↗

The COLUTA ADC ASIC and the ATLAS HL-LHC Liquid Argon Front-End Readout

Abstract The upgraded High-Luminosity Large Hadron Collider (HL-LHC) requires a new radiation tolerant ATLAS Liquid Argon (LAr) Calorimeter readout operating at 40 MHz with 16-bit dynamic range. The Front-End Board 2 (FEB2) will provide the front-end readout for the calorimeter, and will interface a series of custom ASICs due to radiation tolerance requirements of the HL-LHC. The COLUTA is a 65 nm CMOS custom 8-channel 15-bit 40 MSPS ADC ASIC developed for this application. This contribution will present performance results of the final prototype of the COLUTA, surpassing specifications at >11.5 ENOB for relevant frequencies, as well as non-linearity and radiation requirements. Preliminary integration results of the front-end readout components will also be described by means of the FEB2 Pre-Prototype, the “Slice Testboard”.

Instruments & Instrumentation↗

Hardware design and testing of the generic rear transition module for the global trigger subsystem of ATLAS Phase-II Upgrade

Abstract In the framework of the ATLAS experiment’s Phase-II Upgrade at the High-Luminosity Large Hadron Collider (HL-LHC), new and improved trigger hardware and algorithms will be implemented onto a single-level, 10 μs-latency architecture. The Global Trigger is a new subsystem which will bring event-filter capabilities by performing offline-like algorithms on full-granularity calorimeter data. The implementation of the functionality is firmware-focused and composed of several processing nodes, which are hosted on identical hardware, made up of an Advanced Telecommunications Computing Architecture (ATCA) front board, called Global Common Module (GCM), and a rear transition module (RTM), called Generic RTM (GRM). The GRM, which was developed to mitigate the risks deriving from the complex design and power management of the GCM, features an advanced Xilinx Versal Prime system-on-chip and can handle communication with the GCM and Front-End Link eXchange (FELIX) subsystem and trigger processors through 124 25.8 Gb/s transceiver links, for readout and control. Additionally, the GRM mounts a Low-Power GigaBit Transceiver (lpGBT) chip which enables emulation of the detector front-ends for integration tests. This paper presents the GRM hardware design and its testing.

Instruments & Instrumentation↗

Radiation tolerance studies of the HV-mux GaNFETs for the HL-LHC ATLAS ITk Strip detector

For the High-Luminosity upgrade of the LHC, the current ATLAS inner detector will be replaced with a new silicon charged-particle tracker, the ITk, which consists of the ITk Pixel and the ITk Strip subdetector. The high voltage multiplexing (HV-Mux) GaNFETs are radiation-tolerant transistors that permit switching off high voltage to malfunctioning sensors on the ITk Strip modules. To ensure the reliability of the GaNFETs in the high radiation environment expected at the HL-LHC, a sample of the production batch was exposed to gamma radiation. Finally, the GaNFETs were characterized pre-irradiation and post-irradiation, and monitored during irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishing the Quality Assurance programme for the strip sensor production of the ATLAS tracker upgrade including irradiation with neutrons, photons and protons to HL-LHC fluences

The successful pre-production delivery of strip sensors for the new Inner Tracker (ITk) for the upgraded ATLAS detector at the High Luminosity LHC (HL-LHC) at CERN was completed and based on their performance full production has commenced. The overall delivery period is anticipated to last 4 years to complete the approximately 22000 sensors required for the ITk. For Quality Assurance (QA), a number of test structures designed by the collaboration, along with a large area diode and miniature version of the main sensor, are produced in every wafer by the foundry Hamamatsu Photonics K.K (HPK). As well as Quality Control (QC) checks on every main sensor, samples of the QA pieces from each delivery batch are tested both before and after irradiation with results after exposure to neutrons, gammas or protons to fluences and doses corresponding to those anticipated after operation at the HL-LHC to roughly 1.5 times the ultimate integrated luminosity of 4000 fb -1 . In this paper the procedures are presented and the studies carried out to establish that the seven ITk QA Strip Sensor irradiation and test sites meet all the requirements to support this very extensive programme throughout the strip sensor production phase for the ITk project.

47 OTHER INSTRUMENTATION↗

High rate studies of the ATLAS sTGC detector and optimization of the filter circuit on the input of the front-end amplifier

Abstract The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5–7.5 × 10 34 cm -2 s -1 . This represents a more than 3–4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficiently in this high background rate environment. In this article, we summarize multiple performance studies of the small-strip Thin Gap Chamber (sTGC) at high rate using nearly final front-end electronics. We demonstrate that the efficiency versus rate distribution can be well described by an exponential decay with electronics dead-time being the primary cause of loss of efficiency at high rate. We then demonstrate several methods that can decrease the electronics dead-time and therefore minimize efficiency loss. One such method is to install either a pi-network input filter or pull-up resistor to minimize the charge input into the amplifier. We optimized the pi-network capacitance and pull-up resistor resistance using the results from our measurements. The results shown here were not only critical to finalizing the components on the front-end board, but also are critical for setting the optimal operating parameters of the sTGC detector and electronics in the ATLAS cavern.

Instruments & Instrumentation↗

Laser calibration of the ATLAS Tile Calorimeter during LHC Run 2

This article reports the laser calibration of the hadronic Tile Calorimeter of the ATLAS experiment in the LHC Run 2 data campaign. The upgraded Laser II calibration system is described. The system was commissioned during the first LHC Long Shutdown, exhibiting a stability better than 0.8% for the laser light monitoring. The methods employed to derive the detector calibration factors with data from the laser calibration runs are also detailed. These allowed to correct for the response fluctuations of the 9852 photomultiplier tubes of the Tile Calorimeter with a total uncertainty of 0.5% plus a luminosity-dependent sub-dominant term. Finally, we report the regular monitoring and performance studies using laser events in both standalone runs and during proton collisions. These studies include channel timing and quality inspection, and photomultiplier linearity and response dependence on anode current.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of the ATLAS Liquid Argon Front-End ASIC ALFE2 for the HL-LHC upgrade

In this study, ALFE2 is an ATLAS Liquid Argon Calorimeter (LAr) Front-End ASIC designed for the HL-LHC upgrade. ALFE2 comprises four channels of pre-amplifiers and CR-(RC) 2 shapers with adjustable input impedance. ALFE2 features two separate gain outputs to provide 16-bit dynamic-range coverage and an optimum resolution. ALFE2 is characterized using a Front-End Test Board (FETB) based on a Zynq UltraScale+ MPSoC and two octal-channel 16-bit high-speed ADCs. The test results indicate that ALFE2 fulfills or greatly exceeds all specifications on gain, noise, linearity, uniformity, and radiation tolerance.

47 OTHER INSTRUMENTATION↗

How the discovery of Cold Noise delayed the production of ATLAS ITk strip tracker modules by a year

Here, the construction of the ATLAS strip tracker barrel will require the assembly of 12,000 barrel detector modules over the course of 3.5 years. In 2022, during the module pre-production phase, modules were found to display clusters of noisy channels outside required specifications when tested at operating temperatures (-35°C), called “Cold Noise”. Extensive investigations into the cause and mechanism of Cold Noise interrupted pre-production and occupied most barrel module assembly sites. This contribution presents an overview of the year-long investigations into Cold Noise, the final identification of the underlying mechanism and necessary changes for the transition to production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accuracy versus precision in boosted top tagging with the ATLAS detector

The identification of top quark decays where the top quark has a large momentum transverse to the beam axis, known as top tagging , is a crucial component in many measurements of Standard Model processes and searches for beyond the Standard Model physics at the Large Hadron Collider. Machine learning techniques have improved the performance of top tagging algorithms, but the size of the systematic uncertainties for all proposed algorithms has not been systematically studied. This paper presents the performance of several machine learning based top tagging algorithms on a dataset constructed from simulated proton-proton collision events measured with the ATLAS detector at $\sqrt{s}$ = 13 TeV. The systematic uncertainties associated with these algorithms are estimated through an approximate procedure that is not meant to be used in a physics analysis, but is appropriate for the level of precision required for this study. The most performant algorithms are found to have the largest uncertainties, motivating the development of methods to reduce these uncertainties without compromising performance. To enable such efforts in the wider scientific community, the datasets used in this paper are made publicly available.

47 OTHER INSTRUMENTATION↗

An extreme thermal cycling reliability test of ATLAS ITk Strips barrel modules

At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracker, called the ITk. The ITk will be composed of pixel and strip sub-detectors, where the strips portion will be composed of 17,888 silicon strip detector modules. During the HL-LHC running period, the ITk will be cooled and warmed a number of times from about -35°C to room temperature as part of the operational cycle, including warm-ups during yearly shutdowns. To ensure ITk Strips modules are functional after these expected temperature changes, and to ensure modules are mechanically robust, each module must undergo ten thermal cycles and pass a set of electrical and mechanical criteria before it is placed on a local support structure. This paper describes the thermal cycling Quality Control (QC) procedure, and results from the barrel pre-production phase (about 5% of the production volume). Additionally, in order to assess the headroom of the nominal QC procedure of 10 cycles and to ensure modules don't begin failing soon after, four representative ITk Strips barrel modules were thermally cycled 100 times — this study is also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RD53 pixel readout integrated circuits for ATLAS and CMS HL-LHC upgrades

The RD53 collaboration has since 2013 developed new hybrid pixel detector chips with 50 × 50 μm2 pixels for the HL-LHC upgrades of the ATLAS and CMS experiments at CERN. A common architecture, design and verification framework has been developed to enable final pixel chips of different sizes to be designed, verified and tested to handle extreme hit rates of 3 GHz/cm2 (up to 12 GHz per chip) together with an increased trigger rate of 1 MHz and efficient readout of up to 5.12 Gbits/s per pixel chip. Tolerance to an extremely hostile radiation environment with 1 Grad over 10 years and induced SEU (Single Event Upset) rates of up to 100 upsets per second per chip have been major challenges to make reliable pixel chips. Three generations of pixel chips, and many specific mixed signal building blocks and radiation test chips, have been submitted and extensively tested to get to final production chips. The large, complex and high rate pixel chips have been developed with a strong emphasis on low power consumption together with a concurrent development and qualification of novel serial powering at chip, module and system level, to minimize detector material budget.

Alimonti, G↗

The AMACStar ASIC for the HL-LHC ATLAS ITk Strip detector: design, verification, testing, and quality assurance

For the high-luminosity upgrade to the LHC (HL-LHC), the ATLAS detector at CERN requires an all-new inner detector, the Inner Tracker (ITk). The ITk Strip subdetector is made up of silicon modules, which include three types of radiation-hard ASICs. One of these is the Autonomous Monitor and Control (AMAC). The AMAC is manufactured by Global Foundries using 130 nm CMOS8RF DM technology and is approximately 3 by 5 mm in size. This ASIC autonomously monitors the temperatures, voltages, and currents in the module components while controlling critical values in order to prevent these quantities from reaching dangerous levels. The final design, AMACStar, was verified, tested, and ensured to perform all necessary functions. A quality control procedure using an in-house probe station set-up was developed in order to ensure that every individual chip on each wafer of AMACStars required by the ITk Strip project met performance requirements. The average per wafer yield of usable AMACStars is 92.33%, exceeding the design-specific 90% yield estimated for project costing. This estimate was based on actual yields for similar designs in this process.

Analogue electronic circuits↗