Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ASTM Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

638 records · Page 36

Measuring microfocal spots using digital radiography

Measurement of microfocus spot size can be important for several reasons: (1) Quality assurance during manufacture of microfocus tubes; (2) Tracking performance and stability of microfocus tubes; (3) Determining magnification is especially important for digital radiography where the native spatial resolution of the digital system is not adequate for the application; and (4) Knowledge of unsharpness from the focal spot alone. The European Standard EN 12543-5 is based on a simple geometrical method of calculating focal spot size from unsharpness of high magnification film radiographs. The following equations are used for the focal spot size measurement: By similar triangles the following equations are presupposed: f/a = U/b and M = (a+b)/a. These equations can be combined to yield the well known expression: U = f(M - 1). Solving for f, f = U/(M-1). Therefore, the focal spot size, f, can be calculated by measuring the radiographic unsharpness and magnification of a known object. This is the basis for these tests. The European standard actually uses one-half of the unsharpness (which are then added together) from both sides of the object to avoid additional unsharpness contributions due to edge transmission unsharpness of the round test object (the outside of the object is measured). So the equation becomes f = (1/2 U{sub 1} + 1/2 U{sub 2})/(M-1). In practice 1/2 U is measured from the 50% to the 90% signal points on the transition profile from ''black'' to ''white,'' (positive image) or attenuated to unattenuated portion of the image. The 50% to 90% points are chosen as a best fit to an assumed Gaussian radiation distribution from the focal spot and to avoid edge transmission effects. 1/2 U{sub 1} + 1/2 U{sub 2} corresponds about to the full width at half height of a Gaussian focal spot. A highly absorbing material (Tungsten, Tungsten Alloy, or Platinum) is used for the object. Either wires or a sphere are used as the object to eliminate alignment issues. One possibility is to use the wires in the ASTM E2002 unsharpness gage and take two orthogonal images. The signal levels in the image need to be linear with radiation exposure and so may need conversion if a nonlinear detector is used to acquire the image.

47 OTHER INSTRUMENTATION↗

Impact Forces From Artificial and Real Birds on a Large Diameter Hopkinson Bar

Forces were measured from normal impacts with two different artificial bird recipes and two species of real birds on a very rigid flat surface. The tests were conducted by launching the soft body projectiles axially into a Hopkinson bar in accordance with the SAE AS6940 test standard at three different nominal impact conditions: (a) a 1 kg projectile at an impact velocity of 49 m/sec; (b) a 1.8 kg projectile at an impact velocity of 110 m/sec; and (c) a 1.8 kg projectile at an impact velocity of 310 m/sec. At each condition two artificial birds and one real bird projectile were tested with at least three test repeats. Simulations were conducted to assess the effects of projectile orientation and velocity on predicted forces. The Hopkinson bar consisted of an Aluminum 6061 solid cylindrical bar with a diameter of 305 mm and a length of 7.31 m, made up of two 3.66 m long sections that were in axial contact with each other. The bar was instrumented for strain measurement at two locations, 457.2 mm and 609.6 mm (1.5 and 2 diameters) from the impacted face. Forces were calculated from the measured strain. In addition, digital image correlation (DIC) was used to measure the velocity of the free end of the bar. The real bird projectiles were 1 kg Mallard ducks and 1.8 kg Golden Comet chickens that were prepared per ASTM F330-21. Prior to testing, the real birds were placed in muslin bags to minimize tumbling during flight. Two artificial bird formulations were tested, one produced by the University of Dayton Research Institute (UDRI) and the other by the German Aerospace Center, DLR. The UDRI projectile was a homogeneous, relatively soft solid, formulated with a mixture of water, gelatin and phenolic micro-balloons to achieve a nominal density of 0.95 g/cc. The DLR projectile consisted of a printed plastic shell with internal plastic ribs and filled with a gel material. The projectiles were designed such that the overall average density was the desired value of 0.95 g/cc. Initial testing showed that contact between the two Hopkinson bar segments was not sufficient to allow full transmission of the waves through the interface. For the 49 m/sec and 110 m/sec tests this resulted in reflections returning to the strain measurement site prior to the end of the impact. For these tests only a portion of the force pulse could be accurately measured. For the highest velocity tests at 310 m/sec the force pulse was complete by the time reflected waves interfered with the response. Despite this limitation, useful force data were obtained for all velocities. Impact forces were very sensitive to the impact orientation and velocity. The force history generally consisted of an initial region with varying amplitude followed by a relatively constant amplitude response. The steady state region was similar among all projectiles and similar to what would be predicted for an inviscid fluid with a density of 0.95 g/cc. The initial part of the force response exhibited varying degrees of test-to-test repeatability associated with each projectile type. Forces calculated from DIC velocity measurements of the free end of the bar compared favorably those from the strain measurements. In general, the artificial projectile impact forces were quite repeatable from test to test, with some exceptions which could be explained by issues associated with either the projectile itself or with how the projectile exited the gun barrel. For all impact velocities the initial portion of the impact force from the bird projectiles exhibited large test-to-test variability. In this paper, impact forces for three types of projectiles at three impact velocities will be presented with an emphasis on the test-to-test repeatability of the results. Based on test and simulation results a proposed method for normalizing the impact force to minimize effects of differences in projectile orientation, impact velocity and density will also be discussed.

Bird strike↗

Review: Fuel Volatility Standards and Spark-Ignition Vehicle Driveability

We've put spark-ignition engine fuel standards in place in order to ensure acceptable hot and cold weather driveability (HWD and CWD). Vehicle manufacturers and fuel suppliers have developed systems that meet our driveability requirements so effectively that drivers overwhelmingly find that their vehicles reliably start up and operate smoothly and consistently throughout the year. For HWD, fuels that are too volatile perform more poorly than those that are less volatile. Vapor lock is the apparent cause of poor HWD, but there is conflicting evidence in the literature as to where in the fuel system it occurs. Most studies have found a correlation between degraded driveability and higher dry vapor pressure equivalent or lower TV/L = 20, and less consistently with a minimum T50. For CWD, fuels with inadequate volatility can cause difficulty in starting and rough operation during engine warmup. The Driveability Index (DI)-a function of T10, T50, and T90-is well correlated with CWD in hydrocarbon fuels. For ethanol-containing fuels, a correction factor to the DI equation improves the correlation with CWD, although the best value for that factor has still not been determined. Ethanol increases the heat of vaporization. But, this is likely insignificant for E15 and lower concentration fuels. The impact of ethanol on driveability is likely due to its direct effect on vapor pressure at cold temperatures. For E51-E83 or flex-fuel blends, ASTM sets a minimum vapor pressure; however, published data suggest that a correction for the amount of ethanol in the fuel is needed to accurately predict CWD, possibly because ethanol has a higher lower-flammability limit.

30 DIRECT ENERGY CONVERSION↗

Effect of Anoxic Iron Corrosion on WIPP Brine Geochemistry FY23 Final Report (U)

A 280-day study was completed to evaluate the effect of zero-valent iron (Fe 0 ) on the Waste Isolation Pilot Plant (WIPP) brine geochemistry under anticipated reducing conditions. Hydrogen (H 2 ) gas is expected to be present in the repository after closure due to the anoxic corrosion of a vast quantity of iron contained in the waste forms disposed at WIPP; therefore, a background argon atmosphere containing H 2 was chosen for this study. WIPP groundwater brine pH and E h will impact the mobility and fate of plutonium within the repository. Modeling and laboratory results for Castile WIPP brine indicate that equilibrium fa values relative to the standard hydrogen electrode (SHE) are 40 mV more reducing (i.e., more negative) than those for Salado WIPP brine (-480 mV vs. -440 mV, respectively) because of the higher pH of the Castile brine (pH 9 .3 for Castile vs. pH 8.8 for Salado). The E h and pH data were corrected for the effects of high ionic strength. The experimental results for both brines are consistent with thermodynamic predictions using OLI Systems' Mixed Solvent Electrolyte chemical equilibrium model. The measured and corrected pH and E h data from this study are provided in Table ES-I and Table ES-2, respectively. The experimental study, with four test conditions in triplicate, was performed in a dual glovebox with a nominally 3 vol.% H 2 in argon atmosphere (target H 2 range: 3 ± I vol.%). Simulants containing MgO only ( experimental control) and MgO+Fe 0 (WIPP base case) were prepared for both the Salado and Castile brines. MgO was included in all simulants to account for the use of bulk magnesium oxide in the WIPP repository. Fe 0 was included in some simulants to incorporate the effects of the anoxic corrosion of iron and in-situ hydrogen generation in the study. The brine compositions were developed by Sandia National Laboratory (SNL; Xiong, 2008) and have been used in previous WIPP evaluations. The test method (agitation, etc.) is partially based on ASTM D3987-12. Twelve rounds of periodic measurements of pH and E h were performed over the course of the study. Chemical analysis results for liquids and solids (ICP-MS, ICP-ES, IC Anion, TIC, SEM-EDX) are consistent with the pH, E h , and thermodynamic modeling results. This study included the following conditions that deviate from anticipated post-closure conditions following brine intrusion, but were selected to facilitate bench-scale testing to validate modeling of pH and E h for the post-closure WIP P repository: an anoxic glove box atmosphere containing ≤ 4 vol. % H 2 vs. substantially higher H 2 gas concentrations assumed in the WIPP Performance Assessment (PA); a significantly higher liquid-to-solid test ratio compared to the much lower phase ratio anticipated in the WIP P repository; agitation of the simulant bottles to maximize mass transfer; and finally the use of Fe 0 reagents having a much greater surface area than expected in the WIP P repository. Non-representative conditions were chosen for various reasons such as: to provide bounding conservative results, to provide a margin of safety for testing, or to facilitate simulant sub-sampling and analysis. In a parallel effort, aqueous electrolyte thermodynamic models were developed for the synthetic Salado and Castile brines to inform the experimental design, facilitate laboratory data interpretation, and allow extension of evaluations beyond the parameters tested. Thermodynamic modeling simulations including the MgO and Fe 0 additives that are directly relevant to the experimental measurements (e.g., pH calibration curve, ORP corrections) are included in this report. The measured fa of the simulants was close to the OLI model predictions for both brines and was largely controlled by the background H 2 partial pressure in the vapor phase as well as H 2 generated in situ in the aqueous phase by the Fe 0 corrosion. The H 2 gas-phase concentration tested and thermodynamically evaluated was much lower than is assumed in the WIPP PA; however, H 2 (g) concentrations significantly below this level are still predicted to result in very reducing conditions. In conclusion: • The experimental results are consistent with thermodynamic model predictions for fa, pH, and the effects of high ionic strength. • Evidence to date suggests that the H2 concentration in the glovebox atmosphere ultimately determined the final E h values of the simulants and resulted in highly reducing conditions. As a result, little difference was observed between the control simulants containing only MgO and the WIPP base-case simulants that contained MgO and Fe 0 . • This test methodology is recommended for future studies evaluating WIPP repository conditions. The methodology includes: (1) background H 2 in argon with agitation ( or could alternatively include in-situ-generated H 2 in sealed bottles); (2) carefully measured and corrected ORP data ( with much effort focused on allowing the probes to fully stabilize); and (3) ionic-strength-corrected pH data. Other best practices, such as simulant sparging/handling, ORP probe replacement, etc., should also be considered. • The coupling of experimental studies and thermodynamic modeling is also highly recommended because these methods inform and direct one another leading to greater confidence in and understanding of the results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preprocessing of municipal solid waste towards thermal insulating material

Municipal solid waste (MSW) is one of the significant challenges in today’s world. A continuous surge in population, increasing living standards, and rapid urbanization are generating an enormous quantity of MSW. For example, the Environmental Protection Agency (EPA) reported that the total generation of MSW in the United States in 2018 was 292.4 million tons. Improper management of this MSW often leads to the release of greenhouse gases, emission of particulate matters, and formation of dioxins, which all ultimately contributes to climate change. Recycling these wastes via landfills with gas recovery and/or energy and material production via thermal and chemical conversions could be viable options to manage these challenges. Depending on the inherent chemical and structural properties of unrecycled wastes, the carbon structures can be tailored for processing and reuse in manufacturing of structural composites, building materials such as insulation, carbon dense reactant materials such as activated carbon, and so on. According to the EPA’s estimation, MSW in the United States is approximately 23% paper and paperboard, 12% plastics, 6% wood and 6% is textiles. Thus, this research focused on the feasibility of using the MSW as insulation material for the construction sector. The goal of this work was to determine the range of particle sizes, consolidation ratios, and component blends that can achieve insulation R-values within at least 70% that of traditional blown cellulose fiber. To achieve this goal, we designed the testing matrix based on five different component blends, three different particle sizes, and three different compaction level. An American Society for Testing and Materials (ASTM) method (C-739) was used to measure the R-value of the insulation material. Results showed that, adding more paper component in addition to smaller particle size and loose compaction made the insulation similar to the traditional blown cellulose fiber insulation as the R-value was within a range of 2.5-3.0 per inch.

42 ENGINEERING↗

History of Sulphur Content Effects on the Thermal Stability of RP-1 under Heated Conditions

As technologies advance in the aerospace industry, a strong desire has emerged to design more efficient, longer life, reusable liquid hydrocarbon fueled rocket engines. To achieve this goal, a more complete understanding of the thermal stability and chemical makeup of the hydrocarbon propellant is needed. Since the main fuel used in modern liquid hydrocarbon systems is RP-1, there is concern that Standard Grade RP-1 may not be a suitable propellant for future-generation rocket engines due to concern over the outdated Mil-Specification for the fuel. This current specification allows high valued limits on contaminants such as sulfur compounds, and also lacks specification of required thermal stability qualifications for the fuel. Previous studies have highlighted the detrimental effect of high levels of mercaptan sulfur content (^50 ppm) on copper rocket engine materials, but the fuel itself has not been studied. While the role of sulfur in other fuels (e.g., aviation, diesel, and automotive fuels) has been extensively studied, little has been reported on the effects of sulfur levels in rocket fuels. Lower RP-1 sulfur concentrations need to be evaluated and an acceptable sulfur limit established before RP-1 can be recommended for use as the propellant for future launch vehicles. (5 tables, 8 figures, 9 refs.)

ASTM METHOD D-5623↗

IAEA Coordinated Research Project on Master Curve Approach to Monitor Fracture Toughness of RPV Steels: Final Results of the Experimental Exercise to Support Constraint Effects

The precracked Charpy single-edge notched bend, SE(B), specimen (PCC) is the most likely specimen type to be used for determination of the reference temperature, T0, with reactor pressure vessel (RPV) surveillance specimens. Unfortunately, for many RPV steels, significant differences have been observed between the T0 temperature for the PCC specimen and that obtained from the 25-mm thick compact specimen [1TC(T)], generally considered the standard reference specimen for T0. This difference in T0 has often been designated a specimen bias effect, and the primary focus for explaining this effect is loss of constraint in the PCC specimen. The International Atomic Energy Agency (IAEA) has developed a coordinated research project (CRP) to evaluate various issues associated with the fracture toughness Master Curve for application to light-water RPVs. Topic Area 1 of the CRP is focused on the issue of test specimen geometry effects, with emphasis on determination of T0 with the PCC specimen and the bias effect. Topic Area 1 has an experimental part and an analytical part. Participating organizations for the experimental part of the CRP performed fracture toughness testing of various steels, including the reference steel JRQ (A533-B-1) often used for IAEA studies, with various types of specimens under various conditions. Additionally, many of the participants took part in a round robin exercise on finite element modeling of the PCVN specimen, discussed in a separate paper. Results from fracture toughness tests are compared with regard to effects of specimen size and type on the reference temperature T0. It is apparent from the results presented that the bias observed between the PCC specimen and larger specimens for Plate JRQ is not nearly as large as that obtained for Plate 13B (-11 C vs -37 C) and for some of the results in the literature (bias values as much as -45 C). This observation is consistent with observations in the literature that show significant variations in the bias that are dependent on the specific materials being tested. There are various methods for constraint adjustments and two methods were used that reduced the bias for Plate 13B from -37 C to -13 C in one case and to -11 C in the second case. Unfortunately, there is not a consensus methodology available that accounts for the differences observed with different materials. Increasing the Mlim value in the ASTM E-1921 to ensure no loss of constraint for the PCC specimen is not a practicable solution because the PCC specimen is derived from CVN specimens in RPV surveillance capsules and larger specimens are normally not available. Resolution of these differences are needed for application of the master curve procedure to operating RPVs, but the research needed for such resolution is beyond the scope of this CRP.

36 MATERIALS SCIENCE↗

The liquidus temperature of nuclear waste glasses: an international Round-Robin Study

Ten institutions from five countries participated in a Round Robin study to contribute to the Precision and Bias section of an American Society for Testing and Materials standard procedure that Pacific Northwest National Laboratory (PNNL) is developing for measuring the liquidus temperature (TL) of radioactive and simulated waste glasses. In this study, three separate TL measurement methods were a gradient temperature (GT) method, a uniform temperature (UT) method, and a crystal fraction extrapolation (CF) method. Three different glasses were measured with a combination of these three methods. The TL values reported by different institutions are generally consistent and vary within a narrow range. The precision of a TL measurement was evaluated as ±10°C regardless of the method used for making the measurement. The Round Robin glasses were all previously studied at PNNL and included ARG-1 (Glass A), Zr-9 (Glass B), and AmCm2-19 (Glass C), with measured TL values spanning the temperature range ~960-1240°C. The three methods discussed here in more detail are the GT, UT, and CF methods. A best-case precision for TL has been obtained from the data, even though the data were not acquired for all three glasses using all three methods from each participating organization.

ASTM↗