Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “101”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

641 records · Page 36

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating the impacts of Variable Message Signs on Airport Curbside Performance Using Microsimulation

Curbs play a vital role in facilitating vehicle access and egress for individuals at airports. Inefficiently allocating this resource hinders airport accessibility and productivity, resulting in congestion, longer travel times, and increased pollution. As airport demand fluctuates throughout the day and grows over time, airports face intensified curbside pressure. Yet, curb management research is significantly less robust at airports than in urban areas. Given the unbalanced nature of airport demand—riders tend to arrive simultaneously at specific entrances at certain hours—Variable Message Sign (VMS) arises as a cost-effective technology to divert vehicles from congested to underutilized curbs. Still, VMS implementation faces a significant challenge. Historically, airports have managed VMS heuristically and by intuition rather than an evidence-based approach. This research investigates the impacts of implementing VMS on curb performance at airports. By considering different driver compliance rates (DCR), we aim to determine when the sign should be turned on and off to diverge traffic to avoid undesired externalities while enhancing curb performance. Using a validated agent-based microsimulation model, VISSIM, we analyzed the Seattle-Tacoma (SeaTac) Airport as a case study. We modeled sixteen VMS management scenarios and a baseline where the message sign is not displayed, diverging vehicles between the departures and arrivals access levels at four different moments (early morning, morning, afternoon, and late night). We quantified the effects of VMS using seven metrics, including curb productivity index (CPI), curb accessibility (CA), queue length, queue duration, delay, vehicle counts, and emissions. The results of each scenario were compared against the baseline using absolute and relative changes and Repeated Measures ANOVA. Overall, VMS improved curb performance and traffic conditions at the airport, reducing emissions by 14.8% to 8.9%. Moreover, significant reductions in queue length (1,150 ft to 100 ft) and duration (15 to 144 minutes) were observed in the sending link under all VMS policies. However, impacts on the receiving link varied based on congestion, with significant increases in queue duration (9.8 to 24 min) when congested but no substantial changes in free flow. Notably, diverging vehicles to congested links resulted in non-significant results, and activating late and deactivating late VMS affected curb productivity (-5.8% to -61.4%), curb accessibility (-16.5% to -25.8%), cumulative counts (-33.4% to -59.4%), and vehicle delay (95.98% to 594.3%). Activating VMS before congestion begins in the sending link and deactivating before a queue forms in the receiving link yield the most significant improvements: 8.1% to 10.1% in CPI, 9.4% to9.6% in CA, -29.3% to -77.9% in total delay, -11.6% to -13.9% in total emissions, and 101% to 103% in cumulative counts. As the analysis was made with a wide range of time periods, access levels, driver compliance rates, and scenarios, we believe our findings can provide valuable insights into how airports should manage VMS. Our work introduces a novel approach to the scientific airport literature, as some of our metrics were previously unexplored. Additionally, we propose a methodology that other airports can adopt to maximize their curb performance.

Gutierrez, Jorge D.↗

Nearby stellar substructures in the Galactic halo from DESI Milky Way Survey Year 1 Data Release

We report five nearby ($d_{\mathrm{helio}} < 5$ kpc) stellar substructures in the Galactic halo from a subset of 138 661 stars in the Dark Energy Spectroscopic Instrument (DESI) Milky Way Survey Year 1 Data Release. With an unsupervised clustering algorithm, HDBSCAN*, these substructures are independently identified in Integrals of Motion ($E_{\rm tot}$, $L_{\rm z}$, $\log {J_r}$, $\log {J_z}$) space and Galactocentric cylindrical velocity space ($V_{R}$, $V_{\phi }$, $V_{z}$). We associate all identified clusters with known nearby substructures (Helmi streams, M18-Cand10/MMH-1, Sequoia, Antaeus, and ED-2) previously reported in various studies. With metallicities precisely measured by DESI, we confirm that the Helmi streams, M18-Cand10, and ED-2 are chemically distinct from local halo stars. We have characterized the chemodynamic properties of each dynamic group, including their metallicity dispersions, to associate them with their progenitor types (globular cluster or dwarf galaxy). Our approach for searching substructures with HDBSCAN* reliably detects real substructures in the Galactic halo, suggesting that applying the same method can lead to the discovery of new substructures in future DESI data. With more stars from future DESI data releases and improved astrometry from the upcoming Gaia Data Release 4, we will have a more detailed blueprint of the Galactic halo, offering a significant improvement in our understanding of the formation and evolutionary history of the Milky Way Galaxy.

dynamics↗

Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events, and quasiparticle poisoning in superconducting sensors

Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE $v$ NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from subthreshold bursts. Here, in this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm 2 silicon detectors that differ only in the thickness of their substrate (1 vs 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for subthreshold noise events is 0.68 ± 0.38 meV. In our final dataset, we report a world-leading energy resolution of 258.5 ± 0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.

Chang, C. L. [Argonne National Laboratory 1 , 9700↗

Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD

DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.

Front-end electronics for detector readout↗

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Lahaina Energy System Context [Slides]

This presentation is for the Lahaina Energy Partnership Project and provides an overview of the electricity system in Lahaina on the island of Maui in Hawaii.

101 community↗

Cybersecurity at the Grid Edge: Protecting LA's Energy Systems in a Connected World

Join SoCalGas and the National Laboratory of the Rockies (NLR) for an insightful webinar on securing operational technology and energy systems. Los Angeles has the second-largest metro by population in the nation, making it vital to protect the energy infrastructure that powers day-to-day life. However, cybersecurity for energy systems is an immense challenge due to an increasing number of interconnected devices and stakeholders. While there was traditionally a limited need to secure energy infrastructure, the grid is only becoming smarter and more software-defined. Amid aging infrastructure and evolving cyber threats, the need to ensure the security of energy is at an all-time high. Together, SoCalGas and NLR are assessing the current state-of-the-art of the energy ecosystem to understand gaps in current best practices and technologies relevant to powering the city of Los Angeles.

97 MATHEMATICS AND COMPUTING↗

MCL005

Omics-Lethal Human Virus, MERS - MCL005

101 BASIC BIOLOGICAL SCIENCES↗

Using Knowledge-Based Systems to Support Learning of Organizational Knowledge: A Case Study

This paper describes the deployment of a knowledge system to support learning of organizational knowledge at the Jet Propulsion Laboratory (JPL), a US national research laboratory whose mission is planetary exploration and to 'do what no one has done before.' Data collected over 19 weeks of operation were used to assess system performance with respect to design considerations, participation, effectiveness of communication mechanisms, and individual-based learning. These results are discussed in the context of organizational learning research and implications for practice.

knowledge management↗