Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “(Automated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Automated piezoresponse force microscopy domain tracking during fast thermally stimulated phase transition in CuInP 2 S 6

Real-time tracking of dynamic nanoscale processes such as phase transitions by scanning probe microscopy is a challenging task, typically requiring extensive and laborious human supervision. Smart strategies to track specific regions of interest (ROI) in the system during such transformations in a fast and automated manner are necessary to study the evolution of the microscopic changes in such dynamic systems. In this work, we realize automated ROI tracking in piezoresponse force microscopy during a fast (≈0.8 °C s –1 ) thermally stimulated ferroelectric-to-paraelectric phase transition in CuInP 2 S 6 . We use a combination of fast (1 frame per second) sparse scanning with compressed sensing image reconstruction and real-time offset correction via phase cross correlation. The applied methodology enables in situ fast and automated functional nanoscale characterization of a certain ROI during external stimulation that generates sample drift and changes local functionality.

36 MATERIALS SCIENCE↗

Decarbonizing US passenger vehicle transport under electrification and automation uncertainty has a travel budget

Abstract The transportation sector is at the beginning of a transition represented by electrification, shared mobility, and automation, which could lead to either increases or decreases in total travel and energy use. Understanding the factors enabling deep decarbonization of the passenger vehicle sector is essential for planning the required infrastructure investments and technology adoption policies. We examine the requirements for meeting carbon reduction targets of 80% and higher for passenger vehicle transport in the United States (US) by midcentury under uncertainty. We model the changes needed in vehicle electrification, electricity carbon intensity, and travel demand. Since growth in fleet penetration of electric vehicles (EVs) is constrained by fleet stock turnover, we estimate the EV penetration rates needed to meet climate targets. We find for a base case level of passenger vehicle travel, midcentury deep decarbonization of US passenger transport is conditional on reducing the electricity generation carbon intensity to close to zero along with electrification of about 67% or 84% of vehicle travel to meet decarbonization targets of 80% or 90%, respectively. Higher electricity generation carbon intensity and degraded EV fuel economy due to automation would require higher levels of fleet electrification and/or further constrain the total vehicle travel allowable. Transportation deep decarbonization not only depends on electricity decarbonization, but also has a total travel budget, representing a maximum total vehicle travel threshold that still enables meeting a midcentury climate target. This makes encouraging ride sharing, reducing total vehicle travel, and increasing fuel economy in both human-driven and future automated vehicles increasingly important to deep decarbonization.

Alarfaj, Abdullah F. (ORCID:0000000157360662)↗

32 examples of LLM applications in materials science and chemistry: towards automation, assistants, agents, and accelerated scientific discovery

Abstract Large language models (LLMs) are reshaping many aspects of materials science and chemistry research, enabling advances in molecular property prediction, materials design, scientific automation, knowledge extraction, and more. Recent developments demonstrate that the latest class of models are able to integrate structured and unstructured data, assist in hypothesis generation, and streamline research workflows. To explore the frontier of LLM capabilities across the research lifecycle, we review applications of LLMs through 32 total projects developed during the second annual LLM hackathon for applications in materials science and chemistry, a global hybrid event. These projects spanned seven key research areas: (1) molecular and material property prediction, (2) molecular and material design, (3) automation and novel interfaces, (4) scientific communication and education, (5) research data management and automation, (6) hypothesis generation and evaluation, and (7) knowledge extraction and reasoning from the scientific literature. Collectively, these applications illustrate how LLMs serve as versatile predictive models, platforms for rapid prototyping of domain-specific tools, and much more. In particular, improvements in both open source and proprietary LLM performance through the addition of reasoning, additional training data, and new techniques have expanded effectiveness, particularly in low-data environments and interdisciplinary research. As LLMs continue to improve, their integration into scientific workflows presents both new opportunities and new challenges, requiring ongoing exploration, continued refinement, and further research to address reliability, interpretability, and reproducibility.

Computer Science↗

Enhancing lipid production in plant cells through automated high-throughput genome engineering and phenotyping

Plant bioengineering is a time-consuming and labor-intensive process with no guarantee of achieving desired traits. Here, we present a fast, automated, scalable, high-throughput pipeline for plant bioengineering (FAST-PB) in maize (Zea mays) and Nicotiana benthamiana. FAST-PB enables genome editing and product characterization by integrating automated biofoundry engineering of callus and protoplast cells with single-cell matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). We first demonstrated that FAST-PB could streamline Golden Gate cloning, with the capacity to construct 96 vectors in parallel. Using FAST-PB in protoplasts, we found that PEG2050 increased transfection efficiency by over 45%. For proof-of-concept, we established a reporter-gene-free method for CRISPR editing and phenotyping via mutation of high chlorophyll fluorescence 136. We show that diverse lipids were enhanced up to 6-fold using CRISPR activation of lipid controlling genes. In callus cells, an automated transformation platform was employed to regenerate plants with enhanced lipid traits through introducing multigene cassettes. Lastly, FAST-PB enabled high-throughput single-cell lipid profiling by integrating MALDI-MS with the biofoundry, protoplast, and callus cells, differentiating engineered and unengineered cells using single-cell lipidomics. Furthermore, these innovations massively increase the throughput of synthetic biology, genome editing, and metabolic engineering and change what is possible using single-cell metabolomics in plants.

59 BASIC BIOLOGICAL SCIENCES↗

On the combination of molecular replacement and single-wavelength anomalous diffraction phasing for automated structure determination

The combination of molecular replacement and single-wavelength anomalous diffraction improves the performance of automated structure determination with Auto-Rickshaw. A combination of molecular replacement and single-wavelength anomalous diffraction phasing has been incorporated into the automated structure-determination platform Auto-Rickshaw. The complete MRSAD procedure includes molecular replacement, model refinement, experimental phasing, phase improvement and automated model building. The improvement over the standard SAD or MR approaches is illustrated by ten test cases taken from the JCSG diffraction data-set database. Poor MR or SAD phases with phase errors larger than 70° can be improved using the described procedure and a large fraction of the model can be determined in a purely automatic manner from X-ray data extending to better than 2.6 Å resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

RCrane: semi-automated RNA model building

RCrane is a new tool for the partially automated building of RNA crystallographic models into electron-density maps of low or intermediate resolution. This tool helps crystallographers to place phosphates and bases into electron density and then automatically predicts and builds the detailed all-atom structure of the traced nucleotides. RNA crystals typically diffract to much lower resolutions than protein crystals. This low-resolution diffraction results in unclear density maps, which cause considerable difficulties during the model-building process. These difficulties are exacerbated by the lack of computational tools for RNA modeling. Here, RCrane, a tool for the partially automated building of RNA into electron-density maps of low or intermediate resolution, is presented. This tool works within Coot, a common program for macromolecular model building. RCrane helps crystallographers to place phosphates and bases into electron density and then automatically predicts and builds the detailed all-atom structure of the traced nucleotides. RCrane then allows the crystallographer to review the newly built structure and select alternative backbone conformations where desired. This tool can also be used to automatically correct the backbone structure of previously built nucleotides. These automated corrections can fix incorrect sugar puckers, steric clashes and other structural problems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Serial crystallography using automated drop dispensing

Automated, pulsed liquid-phase sample delivery has the potential to greatly improve the efficiency of both sample and photon use at pulsed X-ray facilities. In this work, an automated drop on demand (DOD) system that accelerates sample exchange for serial femtosecond crystallography (SFX) is demonstrated. Four different protein crystal slurries were tested, and this technique is further improved here with an automatic sample-cycling system whose effectiveness was verified by the indexing results. Here, high-throughput SFX screening is shown to be possible at free-electron laser facilities with very low risk of cross contamination and minimal downtime. The development of this technique will significantly reduce sample consumption and enable structure determination of proteins that are difficult to crystallize in large quantities. This work also lays the foundation for automating sample delivery.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Implementation of Automated Characterization of T-type based Power Module for PV Inverter Reliability Assessment

Reliability of power electronics holds the key for future power and energy systems since it is essential for system integration with renewables and energy storage systems. Variation of power module characteristics over the converter’s operational lifetime is a critical indicator to assess its reliability. Device characterization consists of different steps to collect, process, and visualize results, which is usually time-consuming, especially for power modules based on a non-phase-leg configuration, such as T-type circuits, widely applied for PV inverters. To reduce the time, ensure repeatability, and guarantee consistency, an automated test bench can be helpful. This paper focuses on a T-type-based power module and proposes a unique characterization platform and corresponding automation procedure and implementation. Considering the major characterization difference between T-type power modules over the conventional phase-leg power module, first, the special consideration for static characterization is highlighted. Second, the unique dynamic characterization design associated with the T-type power module is described. Finally, the automation of the power module characterization and the test platform is presented along with results and special considerations.

Siraj, Ahmed↗

Automated Metadata Extraction: Challenges and Opportunities

Proper application of the FAIR data principles is what separates a vibrant data ecosystem, in which research data are frequently shared and reused, from a lifeless data graveyard. Automated metadata extraction systems have been proposed as a means of bolstering the findability, interoperability, and reusabil- ity of data repositories with little or no human intervention. These extraction systems mine metadata by crawling a repository and applying lightweight extractors that, for various types of file (e.g., image, CSV file), extract or synthesize relevant attributes. In practice, however, the automated creation of generally useful metadata is fraught with challenges. Data consumers may have different perspectives as to what metadata representations are useful, the standards for recording metadata tend to change over time, and the software model for processing updates can introduce unnecessary human and computational effort. Thus, generalizing extraction for a broad audience of data consumers is a difficult and relatively unsolved problem.In this work, we explore these challenges faced by extraction systems in the context of constructing our own extraction system for science data. We first define the metadata extraction problem and provide context to the issues faced in generalizing metadata. Additionally, we identify potential research directions to help alleviate many of these challenges for all automated extraction systems. Ultimately, this work represents a first step in designing ubiquitous metadata extraction systems that can maximize the value of research data while minimizing the human efforts required in doing so.

Skluzacek, Tyler↗

An Improved Automated Method to Detect Landfast Ice Edge off Zhongshan Station Using SAR Imagery

Landfast ice is an important component of the Antarctic sea ice. Its edge generally advances offshore to its annual maximum extent by mid-winter before retreating later in spring. This study presents an automated method to detect the seaward landfast ice edge (SLIE) at its maximum extent in the beginning in the austral spring (October) for a region northeast of the Amery Ice Shelf, East Antarctic. Here, the net gradient difference algorithm developed by Mahoney has been extended to include the medium edge detection method to automatically delineate the SLIE using the sequential SAR data. The underlying method is to use a spatial gradient operation to identify potential edge pixels, before applying the noise removal using a baseline (2000–2008) SLIE, and a pixel connection technique to generate a contiguous edge. We show that in 2016, the SLIE extended 20 km (25%) further equatorward than in 2008. Good agreement has been achieved between the SLIE derived from our automated method and the manual SLIE extraction using the original SAR as well as a near-coincident Landsat-8 OLI image. The error in the automated approach is minimized when using three to four calibrated SAR images, all with the same incident angle and the maximum separation between them is less than 20 days. Lastly, our results confirm the potential of the method for operational application, and we expect it to promote the study of Antarctic landfast ice.

47 OTHER INSTRUMENTATION↗

Traffic Smoothing Using Explicit Local Controllers: Experimental Evidence for Dissipating Stop-and-go Waves with a Single Automated Vehicle in Dense Traffic

This article presents experimental evidence of the ability of a single automated vehicle acting as a controller to effectively dissipate stop-and-go waves in real traffic. The automated vehicle succeeded in stabilizing the speed profile by reducing oscillations in time and speed variations between vehicles during rush hour on I-24 in the Nashville area. Here, we detail the control design, deployment and results obtained in this experiment, conducted as part of the CIRCLES consortium’s “MegaVanderTest” 2022, which involved a total of 100 automated vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RE-INTEGRATE EMT Simulation Software: DAE Solvers and Automation

Existing electromagnetic transient (EMT) simulation tools face challenges in accelerating EMT simulations, especially for very large-scale power networks. To tackle this issue, next generation EMT simulation tools such as RE-INTEGRATE EMT are being researched upon. Such tools should be equipped with automation capabilities and advanced numerical differential-algebraic equation (DAE) solvers. In this paper, the DAE solvers incorporated within the RE-INTEGRATE EMT simulation tool are discussed. In particular, a modified ODEINT-based DAE solver and the ARKODE solver from SUN-DIALS are leveraged within RE-INTEGRATE EMT. In addition, the automation implemented within RE-INTEGRATE EMT to automate the DAE generation (replacing the need of manual discretization and assembling DAEs) is discussed. Different use cases were implemented using the RE-INTEGRATE EMT tool and were validated with respect to baseline simulations.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

Breast Imaging Reporting and Data System (BI-RADS) breast composition descriptors: Automated measurement development for full field digital mammography

Purpose: The Breast Imaging Reporting and Data System (BI-RADS) breast composition descriptors are used for standardized mammographic reporting and are assessed visually. This reporting is clinically relevant because breast composition can impact mammographic sensitivity and is a breast cancer risk factor. New techniques are presented and evaluated for generating automated BI-RADS breast composition descriptors using both raw and calibrated full field digital mammography (FFDM) image data.Methods: A matched case-control dataset with FFDM images was used to develop three automated measures for the BI-RADS breast composition descriptors. Histograms of each calibrated mammogram in the percent glandular (pg) representation were processed to create the new BR{sub pg} measure. Two previously validated measures of breast density derived from calibrated and raw mammograms were converted to the new BR{sub vc} and BR{sub vr} measures, respectively. These three measures were compared with the radiologist-reported BI-RADS compositions assessments from the patient records. The authors used two optimization strategies with differential evolution to create these measures: method-1 used breast cancer status; and method-2 matched the reported BI-RADS descriptors. Weighted kappa (κ) analysis was used to assess the agreement between the new measures and the reported measures. Each measure's association with breast cancer was evaluated with odds ratios (ORs) adjusted for body mass index, breast area, and menopausal status. ORs were estimated as per unit increase with 95% confidence intervals.Results: The three BI-RADS measures generated by method-1 had κ between 0.25–0.34. These measures were significantly associated with breast cancer status in the adjusted models: (a) OR = 1.87 (1.34, 2.59) for BR{sub pg}; (b) OR = 1.93 (1.36, 2.74) for BR{sub vc}; and (c) OR = 1.37 (1.05, 1.80) for BR{sub vr}. The measures generated by method-2 had κ between 0.42–0.45. Two of these measures were significantly associated with breast cancer status in the adjusted models: (a) OR = 1.95 (1.24, 3.09) for BR{sub pg}; (b) OR = 1.42 (0.87, 2.32) for BR{sub vc}; and (c) OR = 2.13 (1.22, 3.72) for BR{sub vr}. The radiologist-reported measures from the patient records showed a similar association, OR = 1.49 (0.99, 2.24), although only borderline statistically significant.Conclusions: A general framework was developed and validated for converting calibrated mammograms and continuous measures of breast density to fully automated approximations for the BI-RADS breast composition descriptors. The techniques are general and suitable for a broad range of clinical and research applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-9A-02: Structured Noise Index as An Automated Quality Control for Nuclear Medicine: A Two Year Experience

Purpose: Flood-field uniformity evaluation is an essential element in the assessment of nuclear medicine (NM) gamma cameras. It serves as the central element of the quality control (QC) program, acquired and analyzed on a daily basis prior to clinical imaging. Uniformity images are traditionally analyzed using pixel value-based metrics which often fail to capture subtle structure and patterns caused by changes in gamma camera performance requiring additional visual inspection which is subjective and time demanding. The goal of this project was to develop and implement a robust QC metrology for NM that is effective in identifying non-uniformity issues, reporting issues in a timely manner for efficient correction prior to clinical involvement, all incorporated into an automated effortless workflow, and to characterize the program over a two year period. Methods: A new quantitative uniformity analysis metric was developed based on 2D noise power spectrum metrology and confirmed based on expert observer visual analysis. The metric, termed Structured Noise Index (SNI) was then integrated into an automated program to analyze, archive, and report on daily NM QC uniformity images. The effectiveness of the program was evaluated over a period of 2 years. Results: The SNI metric successfully identified visually apparent non-uniformities overlooked by the pixel valuebased analysis methods. Implementation of the program has resulted in nonuniformity identification in about 12% of daily flood images. In addition, due to the vigilance of staff response, the percentage of days exceeding trigger value shows a decline over time. Conclusion: The SNI provides a robust quantification of the NM performance of gamma camera uniformity. It operates seamlessly across a fleet of multiple camera models. The automated process provides effective workflow within the NM spectra between physicist, technologist, and clinical engineer. The reliability of this process has made it the preferred platform for NM uniformity analysis.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-168: Automated Pancreas Segmentation Based On Dynamic MRI

Purpose: MRI guided radiotherapy is particularly attractive for abdominal targets with low CT contrast. To fully utilize this modality for pancreas tracking, automated segmentation tools are needed. A hybrid gradient, region growth and shape constraint (hGReS) method to segment 2D upper abdominal dynamic MRI is developed for this purpose. Methods: 2D coronal dynamic MR images of 2 healthy volunteers were acquired with a frame rate of 5 f/second. The regions of interest (ROIs) included the liver, pancreas and stomach. The first frame was used as the source where the centers of the ROIs were annotated. These center locations were propagated to the next dynamic MRI frame. 4-neighborhood region transfer growth was performed from these initial seeds for rough segmentation. To improve the results, gradient, edge and shape constraints were applied to the ROIs before final refinement using morphological operations. Results from hGReS and 3 other automated segmentation methods using edge detection, region growth and level set were compared to manual contouring. Results: For the first patient, hGReS resulted in the organ segmentation accuracy as measure by the Dices index (0.77) for the pancreas. The accuracy was slightly superior to the level set method (0.72), and both are significantly more accurate than the edge detection (0.53) and region growth methods (0.42). For the second healthy volunteer, hGReS reliably segmented the pancreatic region, achieving a Dices index of 0.82, 0.92 and 0.93 for the pancreas, stomach and liver, respectively, comparing to manual segmentation. Motion trajectories derived from the hGReS, level set and manual segmentation methods showed high correlation to respiratory motion calculated using a lung blood vessel as the reference while the other two methods showed substantial motion tracking errors. hGReS was 10 times faster than level set. Conclusion: We have shown the feasibility of automated segmentation of the pancreas anatomy based on dynamic MRI.

60 APPLIED LIFE SCIENCES↗

SU-E-T-398: Feasibility of Automated Tools for Robustness Evaluation of Advanced Photon and Proton Techniques in Oropharyngeal Cancer

Purpose: Advanced radiotherapy (RT) techniques such as proton pencil beam scanning (PBS) and photon-based volumetric modulated arc therapy (VMAT) have dosimetric advantages in the treatment of head and neck malignancies. However, anatomic or alignment changes during treatment may limit robustness of PBS and VMAT plans. We assess the feasibility of automated deformable registration tools for robustness evaluation in adaptive PBS and VMAT RT of oropharyngeal cancer (OPC). Methods: We treated 10 patients with bilateral OPC with advanced RT techniques and obtained verification CT scans with physician-reviewed target and OAR contours. We generated 3 advanced RT plans for each patient: proton PBS plan using 2 posterior oblique fields (2F), proton PBS plan using an additional third low-anterior field (3F), and a photon VMAT plan using 2 arcs (Arc). For each of the planning techniques, we forward calculated initial (Ini) plans on the verification scans to create verification (V) plans. We extracted DVH indicators based on physician-generated contours for 2 target and 14 OAR structures to investigate the feasibility of two automated tools (contour propagation (CP) and dose deformation (DD)) as surrogates for routine clinical plan robustness evaluation. For each verification scan, we compared DVH indicators of V, CP and DD plans in a head-to-head fashion using Student's t-test. Results: We performed 39 verification scans; each patient underwent 3 to 6 verification scan. We found no differences in doses to target or OAR structures between V and CP, V and DD, and CP and DD plans across all patients (p > 0.05). Conclusions: Automated robustness evaluation tools, CP and DD, accurately predicted dose distributions of verification (V) plans using physician-generated contours. These tools may be further developed as a potential robustness screening tool in the workflow for adaptive treatment of OPC using advanced RT techniques, reducing the need for physician-generated contours.

60 APPLIED LIFE SCIENCES↗

SU-E-T-497: Semi-Automated in Vivo Radiochromic Film Dosimetry Using a Novel Image Processing Algorithm

Purpose: To validate an automated image processing algorithm designed to detect the center of radiochromic film used for in vivo film dosimetry against the current gold standard of manual selection. Methods: An image processing algorithm was developed to automatically select the region of interest (ROI) in *.tiff images that contain multiple pieces of radiochromic film (0.5x1.3cm{sup 2}). After a user has linked a calibration file to the processing algorithm and selected a *.tiff file for processing, an ROI is automatically detected for all films by a combination of thresholding and erosion, which removes edges and any additional markings for orientation. Calibration is applied to the mean pixel values from the ROIs and a *.tiff image is output displaying the original image with an overlay of the ROIs and the measured doses. Validation of the algorithm was determined by comparing in vivo dose determined using the current gold standard (manually drawn ROIs) versus automated ROIs for n=420 scanned films. Bland-Altman analysis, paired t-test, and linear regression were performed to demonstrate agreement between the processes. Results: The measured doses ranged from 0.2-886.6cGy. Bland-Altman analysis of the two techniques (automatic minus manual) revealed a bias of -0.28cGy and a 95% confidence interval of (5.5cGy,-6.1cGy). These values demonstrate excellent agreement between the two techniques. Paired t-test results showed no statistical differences between the two techniques, p=0.98. Linear regression with a forced zero intercept demonstrated that Automatic=0.997*Manual, with a Pearson correlation coefficient of 0.999. The minimal differences between the two techniques may be explained by the fact that the hand drawn ROIs were not identical to the automatically selected ones. The average processing time was 6.7seconds in Matlab on an IntelCore2Duo processor. Conclusion: An automated image processing algorithm has been developed and validated, which will help minimize user interaction and processing time of radiochromic film used for in vivo dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-C-304-04: A Compact Modular Computational Platform for Automated On-Board Imager Quality Assurance

Purpose: Traditionally, the assessment of X-ray tube output and detector positioning accuracy of on-board imagers (OBI) has been performed manually and subjectively with rulers and dosimeters, and typically takes hours to complete. In this study, we have designed a compact modular computational platform to automatically analyze OBI images acquired with in-house designed phantoms as an efficient and robust surrogate. Methods: The platform was developed as an integrated and automated image analysis-based platform using MATLAB for easy modification and maintenance. Given a set of images acquired with the in-house designed phantoms, the X-ray output accuracy was examined via cross-validation of the uniqueness and integration minimization of important image quality assessment metrics, while machine geometric and positioning accuracy were validated by utilizing pattern-recognition based image analysis techniques. Results: The platform input was a set of images of an in-house designed phantom. The total processing time is about 1–2 minutes. Based on the data acquired from three Varian Truebeam machines over the course of 3 months, the designed test validation strategy achieved higher accuracy than traditional methods. The kVp output accuracy can be verified within +/−2 kVp, the exposure accuracy within 2%, and exposure linearity with a coefficient of variation (CV) of 0.1. Sub-millimeter position accuracy was achieved for the lateral and longitudinal positioning tests, while vertical positioning accuracy within +/−2 mm was achieved. Conclusion: This new platform delivers to the radiotherapy field an automated, efficient, and stable image analysis-based procedure, for the first time, acting as a surrogate for traditional tests for LINAC OBI systems. It has great potential to facilitate OBI quality assurance (QA) with the assistance of advanced image processing techniques. In addition, it provides flexible integration of additional tests for expediting other OBI quality assurance tests, such as 2D/3D image quality, making completely automated QA possible. Research Funding from Varian Medical Systems Inc. . Dr. Sasa Mutic receives compensation for providing patient safety training services from Varian Medical Systems, the sponsor of this study.

60 APPLIED LIFE SCIENCES↗