Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “well location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calculation of self-diffusion coefficients in supercritical carbon dioxide using mean force kinetic theory

This paper presents an application of mean force kinetic theory (MFT) to the calculation of the self-diffusivity of CO 2 in the supercritical fluid regime. Two modifications to the typical application of MFT are employed to allow its application to a system of molecular species. Therefore, the first is the assumption that the inter-particle potential of mean force can be obtained from the molecule center-of-mass pair correlation function, which in the case of CO 2 is the C–C pair correlation function. The second is a new definition of the Enskog factor that describes the effect of correlations at the surface of the collision volume. The new definition retains the physical picture that this quantity represents a local density increase, resulting from particle correlations, relative to that in the zero density homogeneous fluid limit. These calculations are facilitated by the calculation of pair correlation functions from molecular dynamics (MD) simulations using the FEPM2 molecular CO2 model. The self-diffusivity calculated from theory is in good agreement with that from MD simulations up to and slightly beyond the density at the location of the Frenkel line. The calculation is compared with and is found to perform similarly well to other commonly used models but has a greater potential for application to systems of mixed species and to systems of particles with long range interatomic potentials due to electrostatic interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automatic Traffic Queue-End Identification using Location-Based Waze User Reports

Traffic queues, especially queues caused by non-recurrent events such as incidents, are unexpected to high-speed drivers approaching the end of queue (EOQ) and become safety concerns. Though the topic has been extensively studied, the identification of EOQ has been limited by the spatial-temporal resolution of traditional data sources. This study explores the potential of location-based crowdsourced data, specifically Waze user reports. It presents a dynamic clustering algorithm that can group the location-based reports in real time and identify the spatial-temporal extent of congestion as well as the EOQ. The algorithm is a spatial-temporal extension of the density-based spatial clustering of applications with noise (DBSCAN) algorithm for real-time streaming data with an adaptive threshold selection procedure. Here, the proposed method was tested with 34 traffic congestion cases in the Knoxville, Tennessee area of the United States. It is demonstrated that the algorithm can effectively detect spatial-temporal extent of congestion based on Waze report clusters and identify EOQ in real-time. The Waze report-based detection are compared to the detection based on roadside sensor data. The results are promising: The EOQ identification time of Waze is similar to the EOQ detection time of traffic sensor data, with only 1.1 min difference on average. In addition, Waze generates 1.9 EOQ detection points every mile, compared to 1.8 detection points generated by traffic sensor data, suggesting the two data sources are comparable in respect of reporting frequency. The results indicate that Waze is a valuable complementary source for EOQ detection where no traffic sensors are installed.

99 GENERAL AND MISCELLANEOUS↗

Chemical Blast Standard (1 kg)

Chemical explosions create blast waves with large overpressure disturbances. It is important to develop a standard blast model based on data to accurately predict acoustic blast-wave amplitudes near detonations and invert for explosion energy from distant observations of blast-wave signals. However, open data from large, controlled chemical explosions with reliable ground truth can be challenging to find. The lack of access to such data could limit the number of contributions to related research and potentially stifle the rate of discoveries or validation of existing models. Here, to address these data scarcity problem, we have curated and compiled a standardized set of 817 blast-wave waveforms from 19 distinct high-explosive events. The blast-wave waveforms are standardized to a 1 kg trinitrotoluene explosion using scaling laws and corrections for location effects. A brief overview of the dataset is presented along with explosion feature models as well as recommendations for extracting explosion features. The resulting dataset is distributed to an open repository in both Seismic Analysis Code and pandas DataFrame formats containing the waveforms, the scaled distances, and the sample rates.

58 GEOSCIENCES↗

Simulating Buildings While the Design is Still in the Architect's Imagination

Very early in the design process, prior to drawing a single line, architects get information from their client or prospective client trying to understand the nature and requirements of the building that needs to be designed. The design of the building is completely fluid, as the architect considers many options in their imagination. The overall massing of the building, the general shape and form, are being considered during this early step. Even for a simple box-shaped building, the aspect ratio between the east-west and the north-south dimensions of the building can greatly impact energy consumption due to daylighting availability. The prevailing winds and building orientation can impact natural ventilation. The locations of high and low population density spaces can also impact energy use. Deciding the floor area per office workstation or the size of the auditorium will impact energy use. Does making a building two stories instead of one reduce energy impacts by reducing roof area or does the additional volume for stairs and elevators result in more energy use. Since certain types of spaces require more windows for occupants than others, the locations of those spaces will determine how much glazing each building orientation has impacting daylighting as well as heating and cooling energy. The project was an attempted first step toward creating a system tailored toward architects for this very early stage in the design process to help them understand the energy impacts of design options. The approach was not to be based on drawing the building, and instead, the main inputs would have been the size of each type of space in the building. This report describes information gathered during the development that might be of use to others developing similar software as well as some of the software that was developed during the project. Phase II funding to continue this work was not pursued due to intellectual property issues discovered during the development of the commercialization plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Collaborative VR/AR Data Visualization Tool

This is the final report on Phase II SBIR for the development of a collaborative VR data visualization tool. In the 15 months of the Phase II, we have met and exceeded most objectives that we outlined for ourselves in the proposal. COVID19 has caused us to do some thing differently, but in fact the outcome is better for the development - we were meant to have traveled to institutions in the UK and EU to show the capabilities in April, but instead we have got into an iterative cycle in-house of weekly testing of the new features and functions. This is working well, so we will soon have the ability to share the application with collaborators in remote locations, without the need to travel. We are also making short videos of the features to share with those afar, again mitigating the need to travel and demonstrate in-person our new capabilities. That said, we are behind on getting input from the Beta testers, but when we do get their input it will be to test features and functions that are working, and not failing due to some glitch, which in turn will more likely lead to the acceptance of the product. One of our goals is to have a near-term commercial product, and we are tantalizingly close to it with commercial interest from LANL, Survice and other entities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predicting Rupture Pressure and Leak Rate of Alloy 600 U-bend Tubes with PWSCC and Comparing with Test Results (Technical Letter Report)

This report summarizes structural integrity work performed for the US NRC that predicts the structural integrity of steam generator (SG) tubes with flaws in the U-bend. The work covers model development and validation for U-bend tubes containing lab-induced primary water stress corrosion cracks (PWSCC). Limit load models for plastic collapse predicting ligament rupture pressure and leak rate of cracked U-bend tubes were developed and validated with pressure tests and finite element analyses (FEAs). Failure pressure and leak rate tests were conducted at room temperature on Alloy 600 U-bend tubes containing flaws located at various locations around the U-bend. Existing models for predicting structural integrity of straight tubes with well defined, rectangular, electro-discharge-machined (EDM) flaws were modified and used to predict the ligament rupture and unstable burst pressures as well as leak rates for the PWSCC flaws in the U-bend section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

THERMS Technology Commercialization Fund Final Report

The technology commercialization fund assisted with the design and development of an intermediate scale packed be thermal energy storage system. Presented in this final report is the design, testing, and modeling of a 100 kWh th radial packed-bed. Air is used as a heat transfer fluid and 3/8” pea gravel is used as the storage medium. Testing has demonstrated the formation of a thermocline within the packed-bed. An air charging temperature of 450 °C was achieved resulting in a charging power of 26.5 kWh th . The radial packed-bed was charged for 5 hours and discharged for 5 hours. Minimal temperature variation was observed at the bottom, middle, and top axial locations of the radial packed-bed which suggests that buoyancy and hydrodynamics in the injection well had a minimal effect on the uniformity of air flow through the bed during charging and discharging. This indicates that the forced convection in a radial direction is dominating the flow regime compared to the buoyancy. The findings of this study suggest an increased air duct diameter through the air heater will increase the charging temperature and increase air mass flow through the system. Increased mass flow through the packed-bed is hypothesized to shorten the thermocline length. Modeled and measured results are compared, and it is here determined that a more comprehensive CFD model will aid in the understanding of air flow and thermocline evolution within the packed-bed.

25 ENERGY STORAGE↗

Development of a Modular Tissue Phantom for Evaluating Vascular Access Devices

Central vascular access (CVA) may be critical for trauma care and stabilizing the casualty. However, it requires skilled personnel, often unavailable during remote medical situations and combat casualty care scenarios. Automated CVA medical devices have the potential to make life-saving therapeutics available in these resource-limited scenarios, but they must be properly designed. Unfortunately, currently available tissue phantoms are inadequate for this use, resulting in delayed product development. Here, we present a tissue phantom that is modular in design, allowing for adjustable flow rate, circulating fluid pressure, vessel diameter, and vessel positions. The phantom consists of a gelatin cast using a 3D-printed mold with inserts representing vessels and bone locations. These removable inserts allow for tubing insertion which can mimic normal and hypovolemic flow, as well as pressure and vessel diameters. Trauma to the vessel wall is assessed using quantification of leak rates from the tubing after removal from the model. Lastly, the phantom can be adjusted to swine or human anatomy, including modeling the entire neurovascular bundle. Overall, this model can better recreate severe hypovolemic trauma cases and subject variability than commercial CVA trainers and may potentially accelerate automated CVA device development.

59 BASIC BIOLOGICAL SCIENCES↗

Viability Assessment of Wind and Solar Renewable Energy Generation in Support of Nationwide Vehicle Electrification

In 2022, the U.S. transportation sector was the largest source of greenhouse gas emissions in the country, with the combination of passenger and commercial vehicles contributing 80% of these emissions. As adoption of passenger electric vehicles continues to climb, sights are being set on the electrification of heavy-duty commercial vehicle (HDCV) fleets. The sustainability of these shifts relies in part on the addition of significant renewable energy generation resources to both bolster the grid in the face of increased demand, and to prevent a shift in the source of greenhouse gas (GHG) emissions to the grid, as opposed to a true net reduction. Additionally, it is necessary to quantify the variations in economic viability across the country for these technologies as it pertains to their productive capabilities. Doing so will encourage investment and ensure that the transition to electrified HDCV fleets is commercially viable, as well as sustainable. In an effort to meet these goals, multiple computational frameworks are used to locate suitable land for renewable infrastructure development, and to quantify spatiotemporal variations in the potential energy generation and financial viability of development sites across the Unites States. First, the Oak Ridge Siting Analysis for power Generation Expansion tool (OR-SAGE) is used to assess the suitability of land for potential wind and solar energy development across the contiguous U.S. From there, resource data from the National Solar Radiation Database (NSRDB) and the Wind Integration National Dataset (WIND) are used in concert with the National Renewable Energy Laboratory (NREL) Renewable Energy Potential (ReV) model to calculate the variation in potential generation capacity for each resource. Additionally, the capital and operational expenditures are calculated for an example configuration of each renewable technology. These measures are then used to calculate the levelized cost of energy (LCOE) of potential sites. All of these results are then processed and analyzed to determine where in the U.S. solar and wind energy are most viable. This viability is based on available generation potential, consistency and stability of energy generation over time, and economic viability with respect to LCOE.

Miller, Brandon [ORNL] (ORCID:0009000300169201)↗

Panel Session 46: Final Closure of Unlined LLW Disposal Facilities Worldwide (R3.5)

This panel discussed the on-going and emerging issues with the design and construction of final cover system of unlined disposal facilities (e.g., material disposal areas (MDAs), subsurface disposal areas (SDAs), burial grounds, and similar historical waste trenches, pits and vaults). The discussion focused on key technical and regulatory issues as well as lessons learned from years of engineering and construction in US and non-US locations. Panelists with presentations: Closure of Unlined LLW Disposal Sites (Craig Benson); Closure of LLW Facilities (Paul Pointon); Final Closure of Unlined LLW Disposal Facilities - Lessons Learned (Kevin Foye)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvements in Optical Surface Measurement Using Reflected Computer Vision Targets

Since 2021, NREL has been developing a system to measure heliostats by measuring the deflection of printed computer vision targets, called the Reflected Target Non-intrusive Assessment (ReTNA) [6], [7]. While this system will have lower resolution than a fringe deflectometry system, it has several important advantages that make it a complimentary technology: 2D surface slope measurement can be generated from a single image, it can operate in ambient lighting, target points can be directly located in 3D space with photogrammetry allowing for a non-flat target, and it's well suited to using a smaller target, and multiple images to measure larger optical surfaces. ReTNA has undergone several significant changes and improvements, described below. This talk will summarize new system layouts designed for commercial use, new computer vision algorithms used to automate the analysis process and validation campaigns for the ReTNA software.

computer vision↗

A phased workflow to define permit‐ready locations for large volume CO 2 injection and storage

Abstract To‐date, only two UIC Class VI permits have been issued by the US Environmental Protection Agency. We illustrate a four‐phase workflow to first identify regional storage resources and then down‐select sites to yield permit‐ready locations that can accept and store large volumes of CO 2 . Specific permit requirements should guide objectives and define deliverables of respective workflow phases. In the first phase we used available regional data and screened structure and injection zones to locate resources that match CO 2 volumes planned to be captured. Available data were also used to assess presence and depth of usable groundwater, the key resource being protected via permitting. We then used advanced, closed‐form, analytical solutions (EASiTool) to estimate CO 2 injectivity into each hydrologically connected injection compartment. In the second phase we acquired and conditioned additional wireline logs and leased available seismic datasets. We interpreted the depositional systems from wireline well‐log character and mapped sandbody geometry to interpolate injection and confining‐zone distribution. Using available data, we mapped faults and locations of freshwater and overpressure (or other capacity‐limiting geologic parameters) in more detail. In the third phase, we used the augmented geologic data to develop a static model for the selected area, extracted the areas of highest interest, and generated and ran dynamic (flow) models. In a fourth phase, we reduced major uncertainties identified in earlier phases. Our case study indicates that to complete preparation of a permit application requires (1) improved lithologic characterization information (thicknesses and horizontal and vertical connectivity) and (2) better definition of poorly defined local faults. © 2023 The Authors. Greenhouse Gases: Science and Technology published by Society of Chemical Industry and John Wiley & Sons Ltd.

58 GEOSCIENCES↗

Ground surface temperature derived Snow Cover Properties, Seward Peninsula, Alaska, 2019-2023

Snow-ground interface temperatures have been collected at the Teller mile marker 27 and Kougarok mile marker 64 field sites on the Seward Peninsula, Alaska from 2019 through 2023 (with data missing from Fall 2020 through Summer 2021 due to COVID). Temperatures were measured using iButton Link DS1921G-F5# Thermochron miniature temperature sensors and Tinytag TGP-4017 internal sensors deployed across the Kougarok 64 and Teller 27 field sites. These sensors are a cost-efficient way to collect snow-ground interface temperatures at a high spatial resolution, and when paired with air temperature data these measurements can provide insight into fine-scale variability in snowpack characteristics across the study sites. From this data, snow process metrics were calculated at each sensor location based on the methods outlined in Staub and Delaloye, 2017. Metrics are calculated daily for each sensor as well as over the entire season. These metrics include ground surface temperature (°C), the number of days under snow cover (number of days), the insulation effect of snow (unitless), the length of the transitional snow periods (number of days), as well as intermediaries such as temperature variability. Calculating these snow processes relies on the assumption that when snow covers a temperature sensor, it is buffered from diurnal fluctuations in air temperature by the insulating snow layer. More information on the calculated metrics can be found in the User Guide of this dataset, as well as in Staub and Delaloye’s 2017 publication Using Near-Surface Ground Temperature Data to Derive Snow Insulation and Melt Indices for Mountain Permafrost Applications. This dataset includes one daily and one seasonal *.csv file of metrics for every year of data, a daily and a seasonal *.csv data dictionary, and one User Guide document (*.pdf) describing data collection and processing.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Applying Machine Learning and Bayesian Inference to Identify and Locate Moving Anthropogenic Sources Using Distributed Acoustic Sensing Data

Distributed acoustic sensing (DAS) systems, which use existing telecommunication fibers, offer high‐resolution capabilities ideal for recording anthropogenic sources. However, the complexity of urban environments and the large amount of data recorded by DAS require automated methods to efficiently detect and categorize anthropogenic sources. Here, we evaluate how well three machine learning models (k‐nearest neighbor [k‐NN], convolutional neural networks, and recurrent‐convolutional neural networks) can identify various anthropogenic sources recorded by DAS. Our findings reveal that both k‐NN and neural network methods perform well in high signal‐to‐noise ratio (SNR) settings. However, their accuracy decreases at SNRs <4. We also use Kalman filtering, a form of Bayesian inference, on backprojected locations of these sources to recover locations that generally fall within standard smartphone Global Positioning System errors. By combining machine learning and Kalman filter results, we calculate a multidimensional model of moving anthropogenic sources. These results demonstrate the potential of DAS data in urban seismology for accurately identifying and locating such sources. Depending on the research objectives, these sources can be further studied or filtered out to improve the quality of seismic data for earthquake studies. Such methods provide a valuable tool for urban seismology and seismic hazard analysis.

Luckie, Thomas William [Sandia National Laboratori↗

A reduced model for the ITER divertor based on SOLPS solutions for ITER Q = 10 baseline conditions: A. identifying options for the control parameters*

Edge codes such as SOLPS coupled to neutral codes such as EIRENE have become so comprehensive and sophisticated that they now constitute, in effect, 'code-experiments' that, as for actual experiments, can benefit from interpretation using simple models and conceptual frameworks, i.e. reduced models. The first task is the identification of options for the reduced model control parameters that are best suited for control of the action of the divertor, i.e. for control of target power loading and sputter-erosion, primarily. A strong correlation between the electron temperature at the divertor target, T e,t , and the neutral deuterium D 2 density at the target, n D2,t , flux-tube resolved, has recently been reported for a number of code studies including SOLPS-4.3 modeling of a set of ~50 ITER baseline cases: Q DT = 10, q 95 = 3, P SOL = 100 MW, metallic walls, and Ne seeding. This part A of the present study reports new results for largely the same ITER cases, confirming the strong correlations reported earlier between local values of T e,t , and (i) n D2,t , and (ii) normalized volumetric losses of power and pressure in the divertor. Strong correlations have now also been found, and are reported here for the first time, between T e,t and all of the divertor target quantities of practical interest. A physical explanation for this surprising result has not been fully identified; nevertheless it has encouraging implications for reduced modeling of the ITER divertor. For such ITER conditions, (i) the global Ne injection rate, Inj Ne [Ne/s], and (ii) the electron temperature at the location on the target where the peak power deposition occurs, T e,t @q ⊥,pk (eV), are found to be promising reduced model control parameters. In the companion report, part B, a reduced model for the ITER divertor is developed and described in detail, based on reversed-direction 2 point modelling, Rev2PM. The input to the reduced model is a value of the variable pair (T et @q ⟂,pk ,Inj Ne ) and the output are values of the various target as well as divertor-entrance quantities of practical interest, e.g. q ⊥,pk , n e,Xpt (the electron density at the poloidal location of the X-point), etc. In part B the reduced model is quantitatively characterized using one half of the code cases; it is then used to successfully predict (replicate) the code values of e.g. n e,Xpt for the other half of the cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Groundwater characterization and monitoring at a complex industrial waste site using electrical resistivity imaging

A contaminated industrial waste site in Washington State (USA) containing buried, metallic-waste storage tanks, pipes, and wells, was evaluated to determine the feasibility of monitoring groundwater remediation activities associated with an underlying perched aquifer system using electrical resistivity tomography. The perched aquifer, located ~65 m below ground surface and ~10 m above the regional water table, contains high concentrations of nitrate, uranium, and other contaminants of concern from past tank leaks and intentional releases of wastes to surface disposal sites. The extent of the perched water aquifer is not well known, and the effectiveness of groundwater extraction for contaminant removal is uncertain, so supplemental characterization and monitoring technologies are being evaluated. Numerical simulations of subsurface flow and contaminant transport were performed with a highly resolved model of the hydrogeologic system and waste site infrastructure, and these simulations were used as the physical basis for electrical resistivity tomography modeling. The modeling explicitly accounted for metallic infrastructure at the site. The effectiveness of using surface electrodes versus surface and horizontal subsurface electrodes, for imaging groundwater extraction from the perched water aquifer, was investigated. Although directional drilling is a mature technology, its use for electrode emplacement in the deep subsurface under a complex industrial waste site via horizontal wells has not yet been demonstrated. Results from this study indicate that using horizontal subsurface electrode arrays could significantly improve the ability of electrical resistivity tomography to image deep subsurface features and monitor remediation activities under complex industrial waste sites.

54 ENVIRONMENTAL SCIENCES↗

Whose Gas is it anyway? Differentiating the Source of a Large Soil Vapor Plume beneath Two Adjacent Waste Sites - 20487

DOE contractor CH2M Hill Plateau Remediation Company is currently responsible for conducting groundwater contamination monitoring at several RCRA treatment, storage, and disposal units located on the Hanford Site in Richland, Washington State. The Nonradioactive Dangerous Waste Landfill treatment, storage, and disposal unit presents a distinct groundwater monitoring problem because of a large multi-contaminant soil vapor plume beneath it that is a likely source of low-level volatile organic compound groundwater contamination. Adjacent to Nonradioactive Dangerous Waste Landfill is the Solid Waste Landfill. Volatile organic compounds are inventory components of both the Nonradioactive Dangerous Waste Landfill and the Solid Waste Landfill. Therefore, it is possible that both sites could be contributing to the soil vapor plume. For regulatory purposes, it is important to differentiate which site is the primary contributor of volatile organic compounds to the plume. An approach was developed to identify the primary volatile organic compound source of the soil vapor plume beneath Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. The site conceptual model hypothesis of vapor-phase volatile organic compound transport to the dissolved phase in groundwater was tested by a simple mathematical model of vapor/liquid equilibrium concentrations at the groundwater/air interface. Once it was shown that vapor-phase volatile organic compound transport to groundwater was a valid conceptual model for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill, spatial and statistical methods were used to determine the primary site contributing to the majority of volatile organic compounds to the soil vapor plume. Average groundwater chloroform, tetrachloroethene, and trichloroethene concentrations from Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring network wells were plotted on maps of the facilities and immediate vicinities and compared to soil vapor sampling probe locations. Principal component analysis and mixing ratios were used to identify source contributions of each treatment, storage, and disposal unit to the plume. Results of the vapor/liquid equilibrium concentrations mathematical model showed that transport phenomena outweigh steady-state equilibria. Estimated vapor/liquid equilibrium concentrations were considerably lower than soil vapor measurements. The results indicate that dynamic vadose zone and groundwater factors such as decreased vapor concentrations with depth, vapor dilution from dispersion in the vadose zone, and advective and diffusional volatile organic compound dilution in groundwater result in groundwater volatile organic compound concentrations much less than would be measured under steady-state equilibrium conditions. Site source contribution differentiation by principal component analysis and mixing ratios was inconclusive using actual soil gas data because of the similarity in concentration values in both datasets for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. Similar data populations suggest mixing of the vapor contributions from both sites by dispersion through the soil matrix pore spaces. However, when groundwater volatile organic compound data were compared between the Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring networks, Solid Waste Landfill mean concentrations were higher, suggesting more vapor-phase volatile organic compound transport to groundwater at those locations. Simulated volatile organic compound soil vapor and groundwater datasets created to test the methods developed for this study show that the method can be successful in source differentiation when significantly different datasets are compared. This paper will describe a method of testing a conceptual model for vapor-phase contaminant transport to groundwater and for differentiating site sources of contaminants comprising a mixed-constituent soil vapor plume. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗