Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

How variable are the volumetric measurements from gated perfusion SPECT when a one-day stress-rest protocol is used?

Background: Using myocardial perfusion scintigraphy (MPS), an increase in left ventricular (LV) volumes or a decrease in ejection fraction (EF) from rest to stress may be clinically important. The variation in these measures between the low-dose stress acquisition and high-dose rest acquisition in a one-day stress-rest protocol has not been established. We assessed the reproducibility of gated volumetric indices between stress and rest and the normal variation in ungated TID ratio for a one-day stress-rest {sup 99m}Tc-tetrofosmin protocol. Methods: Two thousand and one hundred and fifty eight (2158) {sup 99m}Tc-tetrofosmin MPS patient studies were analyzed retrospectively. Studies were excluded for incomplete data, significant technical difficulties, or (for gated analysis but not for analysis of TID ratio) if the LV EF was > 75%. An analysis of gated data was undertaken to establish the reproducibility of ventricular volumes and EF between stress and rest scans. Ungated volume data were analyzed to determine the confidence limits of TID ratio according to ventricular volume. Results: Gated data were analyzed for 621 patients without inducible hypoperfusion. Mean EF at rest was slightly higher than after stress (62.4% ± 10.3% vs 61.2% ± 10.4%, P < 0.001), and the standard deviation of the difference was 5.2% (95% CI 4.9% to 5.5%). Ungated volumes were available for 992 non-ischaemic patients. The upper 95% CI for TID ratio was 1.23. This increased from 1.20 to 1.37 between the highest and lowest deciles of rest ungated volume. Conclusion: Using a one-day stress-rest {sup 99m}Tc-tetrofosmin protocol, a fall in LV EF between rest and stress of > 11.6% or a TID ratio of > 1.23 is likely to be clinically reliable. The upper limit of normal for TID ratio needs to be increased for patients with small LV chamber volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Empirical beam hardening correction (EBHC) for CT

Purpose: Due to x-ray beam polychromaticity and scattered radiation, attenuation measurements tend to be underestimated. Cupping and beam hardening artifacts become apparent in the reconstructed CT images. If only one material such as water, for example, is present, these artifacts can be reduced by precorrecting the rawdata. Higher order beam hardening artifacts, as they result when a mixture of materials such as water and bone, or water and bone and iodine is present, require an iterative beam hardening correction where the image is segmented into different materials and those are forward projected to obtain new rawdata. Typically, the forward projection must correctly model the beam polychromaticity and account for all physical effects, including the energy dependence of the assumed materials in the patient, the detector response, and others. We propose a new algorithm that does not require any knowledge about spectra or attenuation coefficients and that does not need to be calibrated. The proposed method corrects beam hardening in single energy CT data. Methods: The only a priori knowledge entering EBHC is the segmentation of the object into different materials. Materials other than water are segmented from the original image, e.g., by using simple thresholding. Then, a (monochromatic) forward projection of these other materials is performed. The measured rawdata and the forward projected material-specific rawdata are monomially combined (e.g., multiplied or squared) and reconstructed to yield a set of correction volumes. These are then linearly combined and added to the original volume. The combination weights are determined to maximize the flatness of the new and corrected volume. EBHC is evaluated using data acquired with a modern cone-beam dual-source spiral CT scanner (Somatom Definition Flash, Siemens Healthcare, Forchheim, Germany), with a modern dual-source micro-CT scanner (TomoScope Synergy Twin, CT Imaging GmbH, Erlangen, Germany), and with a modern C-arm CT scanner (Axiom Artis dTA, Siemens Healthcare, Forchheim, Germany). A large variety of phantom, small animal, and patient data were used to demonstrate the data and system independence of EBHC. Results: Although no physics apart from the initial segmentation procedure enter the correction process, beam hardening artifacts were significantly reduced by EBHC. The image quality for clinical CT, micro-CT, and C-arm CT was highly improved. Only in the case of C-arm CT, where high scatter levels and calibration errors occur, the relative improvement was smaller. Conclusions: The empirical beam hardening correction is an interesting alternative to conventional iterative higher order beam hardening correction algorithms. It does not tend to over- or undercorrect the data. Apart from the segmentation step, EBHC does not require assumptions on the spectra or on the type of material involved. Potentially, it can therefore be applied to any CT image.

60 APPLIED LIFE SCIENCES↗

Fluorescent Amplification of Next Generation Sequencing Libraries Tools (FA-NGS tools) v1

This is a software utility for calculating pooling volumes and graphing quality control data of next generation sequencing libraries amplified with fluorescent intercalating agents and monitored by real-time quantitative PCR (qPCR). The tool is used to calculate pooling volumes of individual next generation sequencing libraries based on experimentally determined fluorescence values. To do this, fluorescent values are used as a proxy for relative concentration to determine the ratio of transfer volumes. The output is a "transfer file" that specifies the transfer volume and destination well of a given library. The tool can also be used to assess the quality of individual next generation sequencing libraries by melting curve analysis. The output are small-multiples graphs of the melting curves of individual sequencing libraries according to the specified plate layout.

Garber, Megan↗

Comparison of High Level Waste Glass Feeds Containing Frit and Glass Forming Chemicals - 16154

This study compares the impact of frit and glass forming-chemicals on high level waste feed melting behavior. Feeds formulated to yield high-boron (lower waste loading) and low-boron (higher waste loading) glass compositions were prepared by blending a simulated high-level waste with glass-forming additives either in the form of chemicals or pre-melted as glass frit. The feeds were pressed into cylindrical disc-shaped pellets using a die tool and a hydraulic press. Each pellet was heat-treated in a high-temperature furnace equipped with a window to view the pellet's response to increasing temperature, usually up to 1100 deg. C, until the pellet turned into a molten glass droplet. A camera mounted in front of the viewing window was used to take high-quality pictures at predetermined intervals. Images were analyzed using a program that calculated the pellet profile area and volume as functions of temperature. The analyses are used to determine characteristic temperatures and associated volume expansions including foam onset and collapse. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ageing and water homeostasis

This review outlines current knowledge concerning fluid intake and volume homeostasis in ageing. The physiology of vasopressin is summarized. Studies have been carried out to determine orthostatic changes in plasma volume and to assess the effect of water ingestion in normal subjects, elderly subjects, and patients with dysautonomias. About 14% of plasma volume shifts out of the vasculature within 30 minutes of upright posture. Oral ingestion of water raises blood pressure in individuals with impaired autonomic reflexes and is an important source of noise in blood pressure trials in the elderly. On the average, oral ingestion of 16 ounces (473ml) of water raises blood pressure 11 mmHg in elderly normal subjects. In patients with autonomic impairment, such as multiple system atrophy, strikingly exaggerated pressor effects of water have been seen with blood pressure elevations greater than 75 mmHg not at all uncommon. Ingestion of water is a major determinant of blood pressure in the elderly population. Volume homeostasis is importantly affected by posture and large changes in plasma volume may occur within 30 minutes when upright posture is assumed.

Review↗

MO-DE-207B-11: Reliability of PET/CT Radiomics Features in Functional and Morphological Components of NSCLC Lesions: A Repeatability Analysis in a Prospective Multicenter Cohort

Purpose: The goal of this study was to evaluate the repeatability of radiomics features (intensity, shape and heterogeneity) in both PET and low-dose CT components of test-retest FDG-PET/CT images in a prospective multicenter cohort of 74 NSCLC patients from ACRIN 6678 and a similar Merck trial. Methods: Seventy-four patients with stage III-IV NCSLC were prospectively included. The primary tumor and up to 3 additional lesions per patient were analyzed. The Fuzzy Locally Adaptive Bayesian algorithm was used to automatically delineate metabolically active volume (MAV) in PET. The 3D SlicerTM software was exploited to delineate anatomical volumes (AV) in CT. Ten intensity first-order features, as well as 26 textural features and four 3D shape descriptors were calculated from tumour volumes in both modalities. The repeatability of each metric was assessed by Bland-Altman analysis. Results: One hundred and five lesions (primary tumors and nodal or distant metastases) were delineated and characterized. The MAV and AV determination had a repeatability of −1.4±11.0% and −1.2±18.7% respectively. Several shape and heterogeneity features were found to be highly or moderately repeatable (e.g., sphericity, co-occurrence entropy or intensity size-zone matrix zone percentage), whereas others were confirmed as unreliable with much higher variability (more than twice that of the corresponding volume determination). Conclusion: Our results in this large multicenter cohort with more than 100 measurements confirm the PET findings in previous studies (with <30 lesions). In addition, our study is the first to explore the repeatability of radiomics features in the low-dose CT component of PET/CT acquisitions (previous studies considered dosimetry CT, CE-CT or CBCT). Several features were identified as reliable in both PET and CT components and could be used to build prognostic models. This work has received a French government support granted to the CominLabs excellence laboratory and managed by the National Research Agency in the “Investing for the Future” program under reference ANR-10-LABX-07-01, and support from the city of Brest.

60 APPLIED LIFE SCIENCES↗

Design and testing of an energy-absorbing crewseat for the F/FB-111 aircraft, volume 1

A program to determine if the injury potential could be reduced by replacing the existing crewseats with energy absorbing crewseats is explored. An energy-absorbing test seat was designed using much of the existing seat hardware. An extensive dynamic seat test series, designed to duplicate various crew module ground impact conditions, was conducted at a sled test facility. Comparative tests with operational F-111 crewseats were also conducted. After successful dynamic testing of the seat, more testing was conducted with the seats mounted in an F-111 crew module. Both swing tests and vertical drop tests were conducted. The vertical drop tests were used to obtain comparative data between the energy-absorbing and operational seats. Volume 1 describes the energy absorbing test seat and testing conducted, and evaluates the data from both test series.

Shane, S. J.↗

Assessment of Tumor Volumes in Skull Base Glomus Tumors Using Gluc-Lys[{sup 18}F]-TOCA Positron Emission Tomography

Purpose: To assess a threshold for Gluc-Lys[{sup 18}F]-TOCA positron emission tomography (PET) in target volume delineation of glomus tumors in the skull base and to compare with MRI-based target volume delineation. Methods and Materials: The threshold for volume segmentation in the PET images was determined by a phantom study. Nine patients with a total of 11 glomus tumors underwent PET either with Gluc-Lys[{sup 18}F]-TOCA or with {sup 68}Ga-DOTATOC (in 1 case). All patients were additionally scanned by MRI. Positron emission tomography and MR images were transferred to a treatment-planning system; MR images were analyzed for lesion volume by two observers, and PET images were analyzed by a semiautomated thresholding algorithm. Results: Our phantom study revealed that 32% of the maximum standardized uptake value is an appropriate threshold for tumor segmentation in PET-based target volume delineation of gross tumors. Target volume delineation by MRI was characterized by high interobserver variability. In contrast, interobserver variability was minimal if fused PET/MRI images were used. The gross tumor volumes (GTVs) determined by PET (GTV-PET) showed a statistically significant correlation with the GTVs determined by MRI (GTV-MRI) in primary tumors; in recurrent tumors higher differences were found. The mean GTV-MRI was significantly higher than mean GTV-PET. The increase added by MRI to the common volume was due to scar tissue with strong signal enhancement on MRI. Conclusions: In patients with glomus tumors, Gluc-Lys[{sup 18}F]-TOCA PET helps to reduce interobserver variability if an appropriate threshold for tumor segmentation has been determined for institutional conditions. Especially in patients with recurrent tumors after surgery, Gluc-Lys[{sup 18}F]-TOCA PET improves the accuracy of GTV delineation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatiotemporal Reaction Dynamics Control in Two‐Photon Polymerization for Enhancing Writing Characteristics

Since 2001, 3D microfabrication based on two‐photon polymerization (TPP) has drawn extensive attention and interest in biology, optics, photonics, material science, and high‐energy physics. The in‐volume fabrication capability due to the threshold behavior of two‐photon absorption enables TPP higher flexibility compared with other nanofabrication techniques. However, as determined by the in‐volume fabrication feature as well as various reaction dynamics, the writing characteristics of TPP, such as throughput, accuracy, surface quality, and fabrication capability, are still limited. Herein, a comprehensive study is performed on the spatiotemporal behavior of reaction dynamics during TPP fabrication, mainly focusing on spatiotemporal characteristics of radical diffusion, photothermal effect, microscale mechanics, and voxel stacking process. Based on the study, a nonsequential fabrication method is established to simultaneously improve key writing characteristics of TPP and realize sharp features, high speeds, large overhang structure, and smooth surfaces. The method established in this work can be applied to improve the performance of functional devices for various fields.

36 MATERIALS SCIENCE↗

An investigation of the 0.0091 scale External Tank ogive nose (MSFC model 470) in the MSFC 14 inch TWT to determine the pressure distribution around the External Tank Nose (TA3F), volume 1

The model tested was a 0.0091 scale representation of the ogive nose section of the External Tank with nose cap and lightning rod and protuberances. Pressure distribution around the nose cap was determined. Pressure data were also obtained along the ogive nose. Data were obtained over an angle of attack range of + or -5 degrees and over a Mach number range of .6 to 4.96. The Reynolds number per unit length (ft.) ranged from 4.1 million to 4.96 million. There were 22 pressure ports in a single row. Circumferential positions of 0, 22.5, 45, 67.5 and 90 degrees were simulated by rotating the model. The LO2 feed line and LO2 recirculation line were simulated. The effects of the nose spike were investigated over a range of Mach numbers. The data will be useful for venting analyses. Photographs showing flow visualization of the test configuration are given.

Ramsey, P. E.↗

Improved Method For Experiments In Vertical-Flow Boiling

Improved method of experimentation in boiling and adiabatic vertical flows provides for simultaneous determination of two-phase frictional pressure drop and vapor-volume fraction. Gravitational pressure drop determined from precise measurements of temperatures and differential pressures in conjunction with quick closure of valves.

Klausner, J. F.↗

Alpha Shape Analysis (ASA) Framework for Post- Clustering Property Determination in Atom Probe Tomographic Data

While application of clustering algorithms to atom probe tomography data have enabled quantification of solute clusters in terms of number density, size, and subcomposition there exist other properties (e.g., volume, surface area, and composition) that are better determined by defining an interface between the cluster and the surrounding matrix. The limitation in composition results from an ion selection step where the expected matrix ion types are omitted from the cluster search algorithm to enhance the contrast between the matrix and cluster and to reduce the complexity of the search. Previously, composition determination within solute clusters has utilized a secondary envelopment and erosion step on top of conventional methods such as maximum separation. In this work, we present a novel stochastic method that combines the particle identification fidelity of a conventional clustering algorithm with the analytical flexibility of mesh-based approaches through the generation of alpha shapes for each identified cluster. Furthermore, the corresponding mesh accounts for concave components of the clusters and determines the volume and surface area of the clusters; additionally, the mesh boundary is utilized to update the total composition according to the internal ions.

42 ENGINEERING↗

Cervix Regression and Motion During the Course of External Beam Chemoradiation for Cervical Cancer

Purpose: To evaluate the magnitude of cervix regression and motion during external beam chemoradiation for cervical cancer. Methods and Materials: Sixteen patients with cervical cancer underwent computed tomography scanning before, weekly during, and after conventional chemoradiation. Cervix volumes were calculated to determine the extent of cervix regression. Changes in the center of mass and perimeter of the cervix between scans were used to determine the magnitude of cervix motion. Maximum cervix position changes were calculated for each patient, and mean maximum changes were calculated for the group. Results: Mean cervical volumes before and after 45 Gy of external beam irradiation were 97.0 and 31.9 cc, respectively; mean volume reduction was 62.3%. Mean maximum changes in the center of mass of the cervix were 2.1, 1.6, and 0.82 cm in the superior-inferior, anterior-posterior, and right-left lateral dimensions, respectively. Mean maximum changes in the perimeter of the cervix were 2.3 and 1.3 cm in the superior and inferior, 1.7 and 1.8 cm in the anterior and posterior, and 0.76 and 0.94 cm in the right and left lateral directions, respectively. Conclusions: Cervix regression and internal organ motion contribute to marked interfraction variations in the intrapelvic position of the cervical target in patients receiving chemoradiation for cervical cancer. Failure to take these variations into account during the application of highly conformal external beam radiation techniques poses a theoretical risk of underdosing the target or overdosing adjacent critical structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-604: Dosimetric Evaluation of Intracranial Stereotactic Radiotherapy Plans On a LINAC

Purpose: To evaluate the dosimetry of cranial stereotactic radiotherapy (SRT) plans of varying techniques on linac that meets appropriate TG-142 tolerances using 1 cm leaf width multileaf collimator (MLC). Methods: Seventeen spherical targets were generated in the center of a head phantom with diameters ranging 8 mm to 40 mm. SRT plans used 100° non-coplanar arcs and 5 couch angles with 35° spacing. The field size was target plus 1 mm margin. Four plans were created for each target: symmetrical jaws blocking for 5 arcs with 0° collimator (J1C), symmetrical jaws blocking with 5 clockwise arcs with 0° collimator and 5 counter-clockwise arcs with 45° collimator (J2C), MLC blocking for 5 dynamic conformal arcs with 0° collimator (M1C), and MLC blocking for 5 clockwise dynamic conformal arcs with 0° collimators and 5 counter-clockwise dynamic conformal arcs with 45° collimator (M2C).Conformity was evaluated using a ratio of Rx to target volume (PITV). Heterogeneity was determined using a ratio of maximum dose to Rx dose. Falloff was scored using CGIg: difference of effective radii of spheres equal to half and full Rx volumes. Results: All plans met RTOG SRS criteria for conformity and heterogeneity. The mean PITV was 1.52±0.07, 1.49±0.08, 1.39±0.05, and 1.37±0.04 for J1C, J2C, M1C, and M2C plans respectively. The mean CGIg was 75.35±15.79, 74.19±16.66, 77.14±15.12, and 76.28±15.78 for J1C, J2C, M1C, and M2C plans respectively. The mean MDPD was 1.25±0.00 for all techniques. Conclusion: Clinically acceptable SRT plans for spherical targets were created on a linac with 1 cm MLC. Adding two collimator angles and MLC to arcs each improved conformity. The MLC improved the dose falloff while two collimator angles degraded it. This technique can expand the availability of SRT to patients especially to those who cannot travel to a facility with a dedicated stereotactic radiosurgery machine.

60 APPLIED LIFE SCIENCES↗

First experimental measurements with the Segmented Inverted-coaxial GerMAnium (SIGMA) detector

The SIGMA project aims to develop a p-type segmented inverted coaxial point contact germanium detector for gamma-ray tracking and imaging. Here the performance of the first prototype of this type of detector is reported. The measurements performed verified the size and shape of the crystal and determined the location of the complex active volumes of the detector segments. The latter determines the charge collection times that are related to the position of interaction. Good agreement is found between the results and the specified crystal design. The energy resolution of the point contact has been measured to be 0.84 keV and 2.21 keV at 122 keV and 1332 keV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-119: What Effect Have the Volume Defined in the Alignment Clipbox for Cervical Cancer Using Automatic Registration Methods for Cone- Beam CT Verification?

Purpose: To investigate the impact of different clipbox volumes with automated registration techniques using commercially available software with on board volumetric imaging(OBI) for treatment verification in cervical cancer patients. Methods: Fifty cervical cancer patients received daily CBCT scans(on-board imaging v1.5 system, Varian Medical Systems) during the first treatment week and weekly thereafter were included this analysis. A total of 450 CBCT scans were registered to the planning CTscan using pelvic clipbox(clipbox-Pelvic) and around PTV clip box(clipbox- PTV). The translations(anterior-posterior, left-right, superior-inferior) and the rotations(yaw, pitch and roll) errors for each matches were recorded. The setup errors and the systematic and random errors for both of the clip-boxes were calculated. Paired Samples t test was used to analysis the differences between clipbox-Pelvic and clipbox-PTV. Results: . The SD of systematic error(σ) was 1.0mm, 2.0mm,3.2mm and 1.9mm,2.3mm, 3.0mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. The average random error(Σ)was 1.7mm, 2.0mm,4.2mm and 1.7mm,3.4mm, 4.4mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. But, only the SI direction was acquired significantly differences between two image registration volumes(p=0.002,p=0.01 for mean and SD). For rotations, the yaw mean/SD and the pitch SD were acquired significantly differences between clipbox-Pelvic and clipbox-PTV. Conclusion: The defined volume for Image registration is important for cervical cancer when 3D/3D match was used. The alignment clipbox can effect the setup errors obtained. Further analysis is need to determine the optimal defined volume to use the image registration in cervical cancer. Conflict of interest: none.

60 APPLIED LIFE SCIENCES↗

SU-E-T-320: Dosimetric Evaluation of Intracranial Stereotactic Radiotherapy Plans Using Jaws-Only Collimation On a LINAC

Purpose: To evaluate the dosimetry of cranial stereotactic radiotherapy (SRT) plans using jaws-only collimation on linac that meets appropriate TG-142 tolerances. Methods: Seventeen spherical targets were generated in the center of a head phantom with diameters ranging from 8 mm to 40 mm. Plans balanced treatment time with dose gradient and conformity using 13 static fields and 3 couch angles: 9 non-opposed and coplanar fields and 4 non-coplanar fields. The symmetrical jaws field size was target diameter plus 2 mm. The prescription (Rx) was 7 Gy per fraction to the 80% isodose line. Two plans were created for each target: one kept the collimator at 0° (C0), one adjusted the collimator angle 40° for each field to create a 360° sweep over the 9 coplanar fields (CR).Conformity of the Rx to the target was evaluated using a ratio of Rx to target volume (PITV). Heterogeneity was determined using a ratio of maximum dose to Rx dose. Falloff was scored using CGIg: the difference of effective radii of spheres equal to half and full Rx volumes. Results: All plans met RTOG SRS criteria for conformity and heterogeneity. The use of collimator rotation improved conformity by 3.2% on average, the mean PITV was 1.7±0.1 for C0 plans and 1.6±0.1 for CR. Mean heterogeneity was 1.25±0.0 for both C0 and CR. The mean CGIg was 75.9±16.4 for C0 plans and 74.4±17.0 for CR; with a mean dose falloff degradation of 2.5% by CR. Conclusion: Clinically acceptable SRT plans for spherical targets were created using jaws-only collimation with static fields. The addition of sweeping collimator rotation improves conformity at the expense of gradient. This technique can expand the availability of SRT to patients especially to those who cannot travel to a facility with a dedicated stereotactic radiosurgery machine.

60 APPLIED LIFE SCIENCES↗