Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “version control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Drug-Inducible Gene Therapy Effectively Reduces Spontaneous Seizures in Kindled Rats but Creates Off-Target Side Effects in Inhibitory Neurons

Over a third of patients with temporal lobe epilepsy (TLE) are not effectively treated with current anti-seizure drugs, spurring the development of gene therapies. The injection of adeno-associated viral vectors (AAV) into the brain has been shown to be a safe and viable approach. However, to date, AAV expression of therapeutic genes has not been regulated. Moreover, a common property of antiepileptic drugs is a narrow therapeutic window between seizure control and side effects. Therefore, a long-term goal is to develop drug-inducible gene therapies that can be regulated by clinically relevant drugs. In this study, a first-generation doxycycline-regulated gene therapy that delivered an engineered version of the leak potassium channel Kcnk2 (TREK-M) was injected into the hippocampus of male rats. Rats were electrically stimulated until kindled. EEG was monitored 24/7. Electrical kindling revealed an important side effect, as even low expression of TREK M in the absence of doxycycline was sufficient to cause rats to develop spontaneous recurring seizures. Treating the epileptic rats with doxycycline successfully reduced spontaneous seizures. Localization studies of infected neurons suggest seizures were caused by expression in GABAergic inhibitory neurons. In contrast, doxycycline increased the expression of TREK-M in excitatory neurons, thereby reducing seizures through net inhibition of firing. These studies demonstrate that drug-inducible gene therapies are effective in reducing spontaneous seizures and highlight the importance of testing for side effects with pro-epileptic stressors such as electrical kindling. These studies also show the importance of evaluating the location and spread of AAV-based gene therapies in preclinical studies.

60 APPLIED LIFE SCIENCES↗

Development of Improved Graphical Displays for an Advanced Outage Control Center, Employing Human Factors Principles for Outage Schedule Management

The long-term viability of existing nuclear power plants in the United States (U.S.) is dependent upon a number of factors, including maintaining high capacity factors, maintaining nuclear safety, and reducing operating costs, particularly those associated with refueling outages. Refueling outages typically take 20-30 days, and for existing light water NPPs in the U.S., the reactor cannot be in operation during the outage. Furthermore, given that many NPPs generate between $1-1.5 million/day in revenue when in operation, there is considerable interest in shortening the length of refueling outages. Yet refueling outages are highly complex operations, involving multiple concurrent and dependent activities that are somewhat challenging to coordinate; therefore, finding ways to improve refueling outage performance, while maintaining nuclear safety has proven to be difficult. The Advanced Outage Control Center (AOCC) project is a research and development (R&D) demonstration activity under the LWRS Program. LWRS is an R&D program that works closely with industry R&D programs to establish technical foundations for the licensing and managing of long-term, safe, and economical operation of current fleet of NPPs. As such, the LWRS Advanced Outage Control Center project has the goal of improving the management of commercial NPP refueling outages. To accomplish this goal, INL is developing an advanced outage control center (OCC) that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. The overall focus is on developing an AOCC with the following capabilities that enables plant and OCC staff to; Collaborate in real-time to address emergent issues; Effectively communicate outage status to all workers involved in the outage; Effectively communicate discovered conditions in the field to the OCC; Provide real-time work status; Provide automatic pending support notifications; Provide real-time requirements monitoring; Maximize their collective situational awareness to improve decision-making; and Leverage macro data to better support resource allocation. INL has partnered with several commercial NPP utilities to develop a number of advanced outage management technologies. These outage management technologies have focused on both collaborative technologies for control centers and developing mobile technologies for NPP field workers. This report describes recent efforts made in developing a suite of outage technologies to support more effective schedule management. Currently, a master outage schedule is created months in advance using the plant’s existing scheduling software (e.g., Primavera P6). Typically, during the outage, the latest version of the schedule is printed at the beginning of each shift. INL and its partners are developing technologies that will have capabilities such as Automatic Schedule Updating, Automatic Pending Support Notifications, and the ability to allocate and schedule outage support task resources on a sub-hour basis (e.g., outage Micro-Scheduling). The remaining sections of this report describe in more detail the scheduling challenges that occur during outages, how the outage scheduling technologies INL is developing helps address those challenges, and the latest developments on this task (e.g., work accomplished to date and the path forward)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Subject Matter Expert (SME) Feedback on the First Version of the Biosurveillance Analytics Resource directory (BaRD)

As part of a recently funded project, LANL was tasked with the development of the BaRD, a reference tool in support of the Biosurveillance Ecosystem (BSVE) that will serve to enhance situational awareness during an infectious disease outbreak and provide timely and relevant information to support effective decision making to prevent, stop or control an outbreak or epidemic. The BaRD is being designed to enable rapid selection of appropriate models for use in disease prediction, monitoring, or forecasting at various population levels. It is a searchable, relational database that catalogs and classifies model specific information to allow facile reporting on tools of interest.

60 APPLIED LIFE SCIENCES↗

Multicenter, Phase 3 Trial Comparing Selenium Supplementation With Observation in Gynecologic Radiation Oncology

Purpose: We assessed whether adjuvant supplementation with selenium improves the selenium status and reduces side effects of patients treated by radiotherapy (RT) for cervical and uterine cancer. Methods and Materials: Whole-blood selenium concentrations were measured in patients with cervical cancer (n = 11) and uterine cancer (n = 70) after surgical treatment, during RT, at the end of RT, and 6 weeks after RT. Patients with initial selenium concentrations of less than 84{mu}g/L were randomized before RT either to receive 500 {mu}g of selenium (in the form of sodium selenite [selenase (registered) , biosyn Arzneimittel GmbH, Fellbach, Germany]) by mouth on the days of RT and 300 {mu}g of selenium on the days without RT or to receive no supplement during RT. The primary endpoint of this multicenter Phase 3 study was to assess the efficiency of selenium supplementation during RT; the secondary endpoint was to decrease radiation-induced diarrhea and other RT-dependent side effects. Results: A total of 81 patients were randomized. We enrolled 39 in the selenium group (SG) and 42 in the control group (CG). Selenium levels did not differ between the SG and CG upon study initiation but were significantly higher in the SG at the end of RT. The actuarial incidence of diarrhea of Grade 2 or higher according to Common Toxicity Criteria (version 2) in the SG was 20.5% compared with 44.5% in the CG (p = 0.04). Other blood parameters, Eastern Cooperative Oncology Group performance status, and self-reported quality of life were not different between the groups. Conclusions: Selenium supplementation during RT is effective in improving blood selenium status in selenium-deficient cervical and uterine cancer patients and reduces the number of episodes and severity of RT-induced diarrhea.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Features of Controlled Laser Thermal Cleavage of Crystalline Silicon

Controlled laser thermal cleavage of crystalline silicon has been numerically simulated. A 3D analysis of the thermoelastic fields formed in a single-crystal silicon wafer as a result of successive laser heating and exposure to a coolant was performed for three different versions of anisotropy. The simulation was performed for laser irradiation with different wavelengths: 1.06 and 0.808 {mu}m. The calculation results have been experimentally verified using a YAG laser. The results can be used in the electronics industry to optimize the precise separation of silicon wafers into crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time Series Analysis of Photovoltaic Soiling Station Data: Version 1.0, August 2017

The time series data from PV soiling stations, operating in the USA, at different time periods are analyzed and presented. The current version of the paper includes twenty stations operating between 2013 and 2016, but the paper is intended to be periodically updated as more stations and more data become available. The challenges in working with soiling stations data are discussed, including measurement methodology, quality controls, and measurement uncertainty. The soiling profiles of the soiling stations are made available so that the PV community can make use of this data to guide operations and maintence decisions, estimate soiling derate in performance models, and more generally come to a better understanding of the challenges associated with the variability of PV soiling.

14 SOLAR ENERGY↗

Development of Design Guidance for K-12 Schools: From 30% to 50% Energy Savings

This paper describes the development of energy efficiency recommendations for achieving 30% whole-building energy savings in K-12 Schools over levels achieved by following the ANSI/ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings (1999 and 2004 versions). Exhaustive simulations were run to create packages of energy design solutions available over a wide range of K-12 schools and climates. These design recommendations look at building envelope, fenestration, lighting systems (including electrical lights and daylighting), HVAC systems, building automation and controls, outside air treatment, and service water heating. We document and discuss the energy modeling performed to demonstrate that the recommendations will result in at least 30% energy savings over ASHRAE 90.1-1999 and ASHRAE 90.1-2004. Recommendations are evaluated based on the availability of daylighting for the school and by the type of HVAC system. Compared to the ASHRAE 90.1-1999 baseline, the recommendations result in more than 30% savings in all climate zones for both daylit and nondaylit elementary, middle, and high schools with a range of HVAC system types. These recommendations have been included in the Advanced Energy Design Guide for K-12 School Buildings. Compared to the more stringent ASHRAE 90.1-2004 baseline, the recommendations result in more than 30% savings in all climate zones, for only the daylit elementary, middle, and high schools, with a range of HVAC system types. To inform the future development of recommendations for higher level of energy savings, we analyzed a subset of recommendations to understand which energy efficiency technologies would be needed to achieve 50% energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Structured Emission Thermometry Sensor for Burner Control

The overall objective of the program is to control furnace flames for more efficient operation by applying an appropriate sensor technology in a control loop. In Phase I we measured spectra and multispectral imagery from a test furnace at Eclipse, Inc., in Rockford, IL. The test furnace was run at a variety of operating conditions with an oxy-fuel flame, fueled in some tests by natural gas and in others by propane. Using spatial, spectral, and temporal processing, several properties of the flame became observable, including the locations of principal heat release, the extent of the non-luminous portion of the flame, and the local gas temperature. Among the spectra and imagery recorded, the multi-spectral images showed the most promise as a field-compatible measurement system. In Phase II we developed algorithms, driver software, and hardware for what eventually became two independent prototypes: a sophisticated burner-mounted single line-of-sight spectral sensor and a more-mature version of the multispectral furnace imager from Phase I. The maturity of the furnace imager was advanced through significant automation of acquisition, exposure, data recording, and processing to data products. The single line of sight spectral sensor was developed using insights from the test campaigns and was applied in a practical application in an industrial facility where it was used in a control loop. The active control benefits depend on the final applications engineering but show promise to offer smaller excess-air or excess-oxygen requirements, improved response to changing fuel feed stocks, and tighter control on flame properties, resulting in a more consistent product. This thus reduces waste of fuel due to conservative excess-oxidizer requirements and also waste due to off-specification product quality.

30 DIRECT ENERGY CONVERSION↗

Understanding processes that control dust spatial distributions with global climate models and satellite observations

Dust aerosol is important in modulating the climate system at local and global scales, yet its spatiotemporal distributions simulated by global climate models (GCMs) are highly uncertain. In this study, we evaluate the spatiotemporal variations of dust extinction profiles and dust optical depth (DOD) simulated by the Community Earth System Model version 1 (CESM1) and version 2 (CESM2), the Energy Exascale Earth System Model version 1 (E3SMv1), and the Modern-Era Retrospective analysis for Research and Applications version 2 (MERRA-2) against satellite retrievals from Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP), Moderate Resolution Imaging Spectroradiometer (MODIS), and Multi-angle Imaging SpectroRadiometer (MISR). We find that CESM1, CESM2, and E3SMv1 underestimate dust transport to remote regions. E3SMv1 performs better than CESM1 and CESM2 in simulating dust transport and the northern hemispheric DOD due to its higher mass fraction of fine dust. CESM2 performs the worst in the Northern Hemisphere due to its lower dust emission than in the other two models but has a better dust simulation over the Southern Ocean due to the overestimation of dust emission in the Southern Hemisphere. DOD from MERRA-2 agrees well with CALIOP DOD in remote regions due to its higher mass fraction of fine dust and the assimilation of aerosol optical depth. The large disagreements in the dust extinction profiles and DOD among CALIOP, MODIS, and MISR retrievals make the model evaluation of dust spatial distributions challenging. Our study indicates the importance of representing dust emission, dry/wet deposition, and size distribution in GCMs in correctly simulating dust spatiotemporal distributions.

54 ENVIRONMENTAL SCIENCES↗

Concurrent Chemoradiotherapy With Helical Tomotherapy for Oropharyngeal Cancer: A Preliminary Result

Purpose: To review the experience with and evaluate the treatment plan for helical tomotherapy for the treatment of oropharyngeal cancer. Methods and Materials: Between November 1, 2006 and January 31, 2009, 10 histologically confirmed oropharyngeal cancer patients were enrolled. All patients received definitive concurrent chemoradiation with helical tomotherapy. The prescription dose to the gross tumor planning target volume, the high-risk subclinical area, and the low-risk subclinical area was 70Gy, 63Gy, and 56Gy, respectively. During radiotherapy, all patients were treated with cisplatin, 30mg/m{sup 2}, plus 5-fluorouracil (425mg/m{sup 2})/leucovorin (30mg/m{sup 2}) intravenously weekly. Toxicity of treatment was scored according to the Common Terminology Criteria for Adverse Events, version 3.0. Several parameters, including maximal or median dose to critical organs, uniformity index, and conformal index, were evaluated from dose-volume histograms. Results: The mean survival was 18 months (range, 7-22 months). The actuarial overall survival, disease-free survival, locoregional control, and distant metastasis-free rates at 18 months were 67%, 70%, 80%, and 100%, respectively. The average for uniformity index and conformal index was 1.05 and 1.26, respectively. The mean of median dose for right side and left side parotid glands was 23.5 and 23.9Gy, respectively. No Grade 3 toxicity for dermatitis and body weight loss and only one instance of Grade 3 mucositis were noted. Conclusion: Helical tomotherapy achieved encouraging clinical outcomes in patients with oropharyngeal carcinoma. Treatment toxicity was acceptable, even in the setting of concurrent chemotherapy. Long-term follow-up is needed to confirm these preliminary findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spot Scanning-Based Proton Therapy for Intracranial Meningioma: Long-Term Results From the Paul Scherrer Institute

Background: To assess the long-term clinical results of spot scanning proton therapy (PT) in the treatment of intracranial meningiomas. Patients and Methods: Thirty-nine patients with meningioma (histologically proven 34/39) were treated with PT between July 1997 and January 2010. Thirty-two (82.1%) patients were treated as primary treatment (exclusive PT, n = 8; postoperative PT, n = 24). Mean age was 48.3 {+-} 17.9 years and 32 (82.1%) patients had skull base lesions. For patients undergoing surgery, 24 patients had a diagnosis of World Health Organization (WHO) Grade I and 10 of a WHO Grade II/III meningioma, respectively. The female-to-male ratio was 3.3. The median administered dose was 56.0 Gy (relative biologic effectiveness [RBE]) (range, 52.2-66.6) at 1.8-2.0 Gy (RBE) per fraction. Gross tumor volume (GTV) ranged from 0.76 to 546.5 cm{sup 3} (median, 21.5). Late toxicity was assessed according to Common Terminology Criteria for Adverse Events version 3.0. Mean follow-up time was 62.0 months and all patients were followed for >6 months. Results: Six patients presented with tumor recurrence and 6 patients died during follow-up, of which 4 of tumor progression. Five-year actuarial local control and overall survival rates were 84.8% and 81.8%, respectively, for the entire cohort and 100% for benign histology. Cumulative 5-year Grade {>=}3 late toxicity-free survival was 84.5%. On univariate analysis, LC was negatively influenced by WHO grade (p = 0.001), GTV (p = 0.013), and male gender (p = 0.058). Conclusions: PT is a safe and effective treatment for patients with untreated, recurrent, or incompletely resected intracranial meningiomas. WHO grade and tumor volume was an adverse prognostic factor for local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Key Role of Internal Ocean Dynamics in Atlantic Multidecadal Variability During the Last Half Century

Abstract This study presents multiple lines of evidence from observations and model simulations that support a key role for ocean dynamics, rather than external forcings, in Atlantic multidecadal variability (AMV) during the last half century. Observed AMV fingerprints considered here include the low‐frequency spatiotemporal evolution of sea surface temperature, surface heat fluxes, and deep ocean hydrography. While largely absent in the forced response of a large ensemble historical simulations (LENSs), these fingerprints are clearly discernible in a long control simulation where the variability is purely internal. Further evidence derives from initialized decadal prediction simulations, which exhibit much higher skill at predicting the observed AMV of the past 50 years than LENS. The high correlation between the observed AMV and the externally forced version derived from LENS, which has been invoked as evidence for externally driven AMV, is shown to be largely an artifact of concurrent warming since the 1990s.

Kim, Who M.↗

ADEPT Final Report: Dynamic Control of Grid Assets Using Direct AC Converter Cells

Seedling funding was secured through the ARPA-E program to develop a robust, utility-scale Power Converter Augmented Transformer (PCAT). The project designed, fabricated, and tested two 13 kV, 1 MW PCATs operating at an effective switching frequency of up to 50 kHz and at an efficiency of greater than 99%. Two versions of the PCAT were fabricated – one using an imputed DC link (IDCL) topology and the other using a back-to-back (BTB) topology. The IDCL avoids the use of electrolytic capacitors for bulk energy storage, thus improving the lifetime and decreasing the size of the converter, while the BTB topology uses an industry-proven topology that is more commercially viable in the short term. To give the PCAT a lifetime and maintenance profile compatible with typical existing utility assets, a novel Passive Thermal Management System (PTMS) was designed and integrated into both PCATs. The PTMS uses a thermosiphon to remove heat from the power electronic devices without forced cooling and reject it to the ambient environment. In addition, a fail-normal feature was implemented to ensure that in the event of PCAT failure the functionality of the underlying transformer is retained. Attainment of project objectives was verified through testing at the Georgia Tech National Electrical Energy Testing Research and Applications Center (NEETRAC). The IDCL-based PCAT had an efficiency of more than 99.10% and the BTB-based PCAT had an efficiency of more than 99.75%. During testing, the PTMS exceeded project requirements by rejecting the 5 kW output of the converters to a 40 °C environment while keeping devices junction temperatures within their tolerances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the reheat coil adds additional heat to maintain the supply air temperature close to the return air temperature (100% latent cooling). Project Outcomes Key Phase II objectives were to develop a pre-production version of the system and to demonstrate its performance in an actual house. The system was first tested in the laboratory and subsequently underwent field-testing at a new house in Gainesville, Florida. Field testing began in 2006 with monitoring of a 'conventional best practices' system that included a two stage air conditioner and Energy Star dehumidifier. In September 2007, the I-HVCD components were installed for testing. Both systems maintained uniform indoor temperatures, but indoor RH control was considerably better with the I-HVCD system. The daily variation from average indoor humidity conditions was less than 2% for the I-HVCD vs. 5-7% for the base case system. Data showed that the energy use of the two systems was comparable. Preliminary installed cost estimates suggest that production costs for the current I-HVCD integrated design would likely be lower than for competing systems that include a high efficiency air conditioner, dehumidifier, and fresh air ventilation system. Project Benefits This project verified that the I-HVCD refrigeration compacts are compact (for easy installation and retrofit) and can be installed with air conditioning equipment from a variety of manufacturers. Project results confirmed that the system can provide precise indoor temperature and RH control under a variety of climate conditions. The I-HVCD integrated approach offers numerous benefits including integrated control, easier installation, and reduced equipment maintenance needs. Work completed under this project represents a significant step towards product commercialization. Improved indoor RH control and fresh air ventilation are system attributes that will become increasingly important in the years ahead as building envelopes improve and sensible cooling loads continue to fall. Technologies like I-HVCD will be instrumental in meeting goals set by Building America and other programs to reduce energy use while improving the indoor environment. Next Steps The following steps are needed to bring the product to commercialization: (1) Value engineering to reduce costs; (2) Addition of zoning capability to improve marketability; (3) Fabrication and testing of additional prototypes; and (4) Identification of a manufacturer. Initial efforts to interest large air conditioner manufacturers has shown some interest, but the preferred path to market may be to employ a boutique manufacturer that markets to HVAC contractors. Distribution of the results of this work will improve opportunities for attracting manufacturers. Additional funding is needed to prepare the product for this final step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Waste Compliance and Tracking System (WCATS) Version 3 Requirements Document

This document describes the end-user requirements for the Waste Compliance and Tracking System (WCATS) project in accordance with the WCATS Software Quality Management Plan, EPC-WMP-WCATSPLAN-001. The WCATS application shall support the generation, characterization, processing, and shipment of LANL radioactive, hazardous, and industrial waste. Regulatory drivers include RCRA hazardous waste, DOT shipping, NNSA nuclear material control and accountability, DOE nuclear safety, TSDF permit, and transuranic waste certification requirements. The system will utilize a task-based architecture that supports the spectrum of treatment, storage, disposal, administrative, and characterization based unit operations necessary to manage waste from cradle to grave. The application design shall readily accommodate new facilities, processes, workflow, signature requirements, and so forth, via end-user established metadata. WCATS will provide support for representing waste storage and disposal facilities, buildings, rooms, and grid layouts (x, y, z) to support waste and radioactive material inventory management. Nuclear material at risk (MAR), DOE hazard rating (e.g., Category II facility) compliance per DOE-STD-1027, and permit inventory requirements will be configurable for any storage or disposal facility, or waste operation, and the system will automatically evaluate and enforce those requirements. In addition, the application will support the characterization and management of the entire range of hazardous and radioactive wastes (TRU, MTRU, LLW, MLLW, hazardous waste, etc.) that might be colocated or processed at a permitted facility. Some capabilities not found in traditional systems include user-defined tank systems for liquid waste, user-defined work paths (i.e., sequence of operations), and an equipment subsystem for tracking the calibration, maintenance, and inspection of tools used to process waste, such as torque wrenches, scales, pH probes, etc. The application incorporates a desktop and mobile user interface as shown in Figure 1. The mobile interface supports field operations, such as waste item characterization, intra-facility transfers, internal and external audits, and shipment preparation and receipt.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutrino-assisted early dark energy: theory and cosmology

Abstract The tension between measurements of the Hubble constant obtained at different redshifts may provide a hint of new physics active in the relatively early universe, around the epoch of matter-radiation equality. A leading paradigm to resolve the tension is a period of early dark energy, in which a scalar field contributes a subdominant part of the energy budget of the universe at this time. This scenario faces significant fine-tuning problems which can be ameliorated by a non-trivial coupling of the scalar to the standard model neutrinos. These become non-relativistic close to the time of matter-radiation equality, resulting in an energy injection into the scalar that kick-starts the early dark energy phase, explaining its coincidence with this seemingly unrelated epoch. We present a minimal version of this neutrino-assisted early dark energy model, and perform a detailed analysis of its predictions and theoretical constraints. We consider both particle physics constraints — that the model constitute a well-behaved effective field theory for which the quantum corrections are under control, so that the relevant predictions are within its regime of validity — and the constraints provided by requiring a consistent cosmological evolution from early through to late times. Our work paves the way for testing this scenario using cosmological data sets.

Astronomy & Astrophysics↗

SU-D-213-01: Transparent Photon Detector For The Online Monitoring Of IMRT Beams

Purpose: An innovative Transparent Detector for Radiotherapy (TraDeRa) has been developed. The detector aims at real-time monitoring of modulated beam ahead of the patient during delivery sessions, with a field cover up to 40×40 cm {sup 2}. Methods: TraDeRa consists in a pixelated matrix of ionization chambers with a patented electrodes design. An in-house designed specific integrated circuit allows to extract the signal and provides a real-time map of beam intensity and shape, at the linac pulse-scale. The measurements under irradiation are made with a 6 MV clinical X-Ray beam. Dose calculations are performed with the Monte Carlo code PENELOPE, modeling the full accelerator head and the TraDeRa detector. Results: A 2 % attenuation of the beam was measured in the presence of TraDeRa and the PENELOPE dosimetric study showed no significant modification of the photon beam properties. TraDeRa detects error leaf position as small as 1 mm compared to a reference field, for both static and modulated fields. In addition, measurements are accurate over a large dynamic range from low intensity signals, as inter-leaves leaks, to very high intensities as obtained on the medical line of the European Synchrotron Radiation Facility. The detector is fully operational for conventional and high dose rate beams as FFF modes (up to 2400 MU/min). Conclusion: The current version of TraDeRa shows promising results for IMRT quality assurance (QA), allowing pulse-scale monitoring of the beam and high sensitivity for errors detection. The attenuation is small enough not to hinder the irradiation while keeping the beam upstream of the patient under constant control. A final prototype under development will include 1600 independent electrodes, half of them with a high resolution centered on the beam axis. This compact detector provides an independent set of measurements for a better QA. Funding support : This work was supported by the LABEX PRIMES (ANR-11-LABX-0063) of Universite de Lyon, within the program “Investissements d’Avenir” (ANR-11-IDEX-0007) operated by the French National Research Agency (ANR) and within the project “INSPIRA” operated by the OSEO institution.

60 APPLIED LIFE SCIENCES↗