Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “utility rate analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Input/output behavior of supercomputing applications

The collection and analysis of supercomputer I/O traces and their use in a collection of buffering and caching simulations are described. This serves two purposes. First, it gives a model of how individual applications running on supercomputers request file system I/O, allowing system designer to optimize I/O hardware and file system algorithms to that model. Second, the buffering simulations show what resources are needed to maximize the CPU utilization of a supercomputer given a very bursty I/O request rate. By using read-ahead and write-behind in a large solid stated disk, one or two applications were sufficient to fully utilize a Cray Y-MP CPU.

Miller, Ethan L.↗

Concurrent Probabilistic Simulation of High Temperature Composite Structural Response

A computational structural/material analysis and design tool which would meet industry's future demand for expedience and reduced cost is presented. This unique software 'GENOA' is dedicated to parallel and high speed analysis to perform probabilistic evaluation of high temperature composite response of aerospace systems. The development is based on detailed integration and modification of diverse fields of specialized analysis techniques and mathematical models to combine their latest innovative capabilities into a commercially viable software package. The technique is specifically designed to exploit the availability of processors to perform computationally intense probabilistic analysis assessing uncertainties in structural reliability analysis and composite micromechanics. The primary objectives which were achieved in performing the development were: (1) Utilization of the power of parallel processing and static/dynamic load balancing optimization to make the complex simulation of structure, material and processing of high temperature composite affordable; (2) Computational integration and synchronization of probabilistic mathematics, structural/material mechanics and parallel computing; (3) Implementation of an innovative multi-level domain decomposition technique to identify the inherent parallelism, and increasing convergence rates through high- and low-level processor assignment; (4) Creating the framework for Portable Paralleled architecture for the machine independent Multi Instruction Multi Data, (MIMD), Single Instruction Multi Data (SIMD), hybrid and distributed workstation type of computers; and (5) Market evaluation. The results of Phase-2 effort provides a good basis for continuation and warrants Phase-3 government, and industry partnership.

Abdi, Frank↗

Time-Extended Payoffs for Collectives of Autonomous Agents

A collective is a set of self-interested agents which try to maximize their own utilities, along with a a well-defined, time-extended world utility function which rates the performance of the entire system. In this paper, we use theory of collectives to design time-extended payoff utilities for agents that are both aligned with the world utility, and are "learnable", i.e., the agents can readily see how their behavior affects their utility. We show that in systems where each agent aims to optimize such payoff functions, coordination arises as a byproduct of the agents selfishly pursuing their own goals. A game theoretic analysis shows that such payoff functions have the net effect of aligning the Nash equilibrium, Pareto optimal solution and world utility optimum, thus eliminating undesirable behavior such as agents working at cross-purposes. We then apply collective-based payoff functions to the token collection in a gridworld problem where agents need to optimize the aggregate value of tokens collected across an episode of finite duration (i.e., an abstracted version of rovers on Mars collecting scientifically interesting rock samples, subject to power limitations). We show that, regardless of the initial token distribution, reinforcement learning agents using collective-based payoff functions significantly outperform both natural extensions of single agent algorithms and global reinforcement learning solutions based on "team games".

Tumer, Kagan↗

Three Dimensional Instantaneous Spray Measurements of Additively Manufactured Candidate Injector Schemes at Varying Pressure Drops

Additively manufactured (AM) injectors have the potential to improve upon the combustion performance achieved using traditionally manufactured (TM) injectors. Traditionally manufactured injector combustion performance decreases greatly in off-design conditions. Additively manufactured injectors hold the potential to sustain high combustion performance over a broader range of operating conditions than currently seen in TM injectors. Additively manufactured injectors promise to offer higher resistances to instability and achieve better overall propellant mixing and atomization for all types of combustion devices. This study expands upon previous studies that used 2-D imaging techniques to characterize the injector spray pattern of candidate AM injector elements. In this study, 3-D instantaneous measurements of the injector spray pattern are taken, allowing for deeper insight into the liquid spray breakup, an inherently 3-D phenomena. Stereo imaging is used for three dimensional analysis, which utilizes two cameras at different angles to reconstruct a three dimensional reconstruction. With this information, AM injectors can be designed to improve propellant mixing and atomization and reduce breakup length. As part of this work, a high-pressure, cold flow experimental spray facility was modified to measure each injector’s spray characteristics in terms of 𝑅𝑒 𝐿 and 𝑊𝑒 𝑔 . This facility is operated to capture instantaneous stereo photographic images, mass flow rates, and injector element thrust for pressure drop across the injector face ranging from 100 to 200 psig at a stiffness ratio of 1.0.

Murphy Mitchell↗

Analysis of static Wilson line correlators from lattice QCD at finite temperature with T -matrix approach

The thermodynamic T-matrix approach is used to study Wilson line correlators (WLCs) for a static quark-antiquark pair in the quark-gluon plasma (QGP). Selfconsistent results that incorporate constraints from the QGP equation of state can approximately reproduce WLCs computed in 2+1-flavor lattice-QCD (lQCD), provided the input potential exhibits less screening than in previous studies. Utilizing the updated potential to calculate pertinent heavylight T-matrices we evaluate thermal relaxation rates of heavy quarks in the QGP. We find a more pronounced temperature dependence for low-momentum quarks than in our previous results (with larger screening), which turns into a weaker temperature dependence of the (temperature-scaled) spatial diffusion coefficient, in fair agreement with the most recent lQCD data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

North Carolina Water Utility Builds Resilience with Distributed Energy Resources

As the frequency and duration of grid outages increase, backup power systems are becoming more important for ensuring that critical infrastructure continues to provide essential services. Most facilities rely on diesel generators, which may be ineffective during long outages owing to limited fuel supplies and high generator failure rates. Distributed energy resources such as solar, storage, and combined-heat-and-power systems, coupled with on-site biofuel production, offer an alternative source of on-site generation that can provide both cost savings and resilience (i.e., the ability to respond to catastrophic events with longer-term consequences). A mixed-integer linear program minimizes costs and maximizes resilience at a wastewater treatment plant in Wilmington, North Carolina. We find that the plant can reduce life-cycle energy costs by 3.1% through the installation of a hybrid combined-heat-and-power, photovoltaic, and storage system. When paired with existing diesel generators, this system can sustain full load for seven days while saving $664,000 over 25 years and reducing diesel fuel use by 48% compared with the diesel-only solution. This analysis informed a decision by the Cape Fear Public Utility Authority to allocate funds for the implementation of a combined-heat-and-power system at the wastewater treatment plant in fiscal year 2023. Finally, the benefits of deploying hybrid combined-heat-and-power technologies and the utilization of on-site biofuel production extend, on a national scale, to thousands of wastewater treatment facilities and other types of critical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrification Analysis: Container Ports' Cargo Handling Equipment

This one-page highlight details the key takeaways from a project that utilized NREL's Fleet Research, Energy Data, and Insights (FleetREDI) data analysis pipeline, the Electrification Analysis of Container Ports' Cargo Handling Equipment project. This project created a scalable solution to model energy demand per shipping container moved (kWh/TEU) for an all-electric cargo handling equipment fleet located at a maritime port. The model allows stakeholders to understand energy demand at each electric vehicle (EV) equipment level and is easily scalable to container demand and EV adoption rate projections.

ADVANCED PROPULSION SYSTEMS↗

Cryogenic Carbon Capture™ Technoeconomic Analysis

The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.

20 FOSSIL-FUELED POWER PLANTS↗

Man-rated flight software for the F-8 DFBW program

The design, implementation, and verification of the flight control software used in the F-8 DFBW program are discussed. Since the DFBW utilizes an Apollo computer and hardware, the procedures, controls, and basic management techniques employed are based on those developed for the Apollo software system. Program assembly control, simulator configuration control, erasable-memory load generation, change procedures and anomaly reporting are discussed. The primary verification tools are described, as well as the program test plans and their implementation on the various simulators. Failure effects analysis and the creation of special failure generating software for testing purposes are described.

Bairnsfather, R. R.↗

Glovebox CFD Analysis: Low-Flow, Laminar CFD Analysis of Glovebox Ventilation and Humidity Transport in Ansys Fluent 2025 R1

There are gloveboxes that frequently exceed the 30% relative humidity level required for operations. These exceedances result in alternative operations needing to be utilized. This report documents a computational fluid dynamics (CFD) analysis performed to characterize airflow and humidity transport within a representative glovebox under nominal, low-flow conditions. The analysis focuses on establishing the flow regime, identifying transport-limited regions, and evaluating the implications of laminar flow on humidity removal. A single-phase, laminar flow model with a species transport model was used to represent air and water vapor mixing. Results demonstrate that, at the nominal flow rates, airflow is laminar with weak mixing, which will result in long residence times, tens of minutes long or more, in low-velocity regions. These conclusions suggests that humidity reduction is transport-limited. This analysis provides qualitative insight into airflow structure and humidity transport trends. In addition to characterization of glovebox airflow and humidity transport, results are intended to inform experimental validation and future transient modeling efforts.

42 ENGINEERING↗

A comprehensive solar energy system analysis data base in Huntsville, Alabama

The history of a comprehensive solar energy system analysis data base developed by NASA/Marshall Space Flight Center and the University of Alabama is presented, along with its current status. The Marshall Information Retrieval and Data Storage (MIRADS) system was chosen for the data base, and feedback systems were arranged to cope with changes in the needs of the program management for the type of data gathered. The final structure of the data base consists of 22 files divided into 6 topical sections: summaries, climatological, utility rates, architectural, equipment, and economics. The data base offers help to the solar industry in two ways: it provides information and it serves as a model for users trying to establish the climatic and socioeconomic variables they should take into account when they examine a potential market for solar energy equipment.

Goddard, J. P.↗

Constraining the Sulfur Dioxide Degassing Flux from Turrialba Volcano, Costa Rica Using Unmanned Aerial System Measurements

Observed sulfur dioxide (SO2)mixing ratios onboard unmanned aerial systems (UAS) duringMarch 11-13, 2013 are used to constrain the three-day averaged SO2 degassing flux fromTurrialba volcanowithin a Bayesian inverse modeling framework. A mesoscale model coupled with Lagrangian stochastic particle backward trajectories is used to quantify the source-receptor relationships at very high spatial resolutions (i.e., b1 km). The model shows better performance in reproducing the near-surface meteorological properties and observed SO2 variations when using a first-order closure non-local planetary boundary layer (PBL) scheme. The optimized SO2 degassing fluxes vary from 0.59 +/- 0.37 to 0.83 +/- 0.33 kt d−1 depending on the PBL scheme used. These fluxes are in good agreement with ground-based gas flux measurements, and correspond to corrective scale factors of 8-12 to the posteruptive SO2 degassing rate in the AeroCom emission inventory. The maximum a posteriori solution for the SO2 flux is highly sensitive to the specification of prior and observational errors, and relatively insensitive to the SO2 loss term and temporal averaging of observations. Our results indicate relatively low degassing activity but sustained sulfur emissions from Turrialba volcano to the troposphere during March 2013. This study demonstrates the utility of low-cost small UAS platforms for volcanic gas composition and flux analysis.

Xi, Xin↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen (N)—a noncondensable gas (NCG), simulating air in the reactor containment—to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted—utilizing iterative and nodalized mass and heat transfer calculation—to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results—a ratio of experimental and Nusselt’s theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An economic analysis of the role of materials, system engineering, and performance in electrochemical carbon dioxide conversion to formate

The development of technologies that utilize carbon dioxide is important to mitigating climate change. The electrochemical reduction of carbon dioxide is one technology that can utilize greenhouse gasses that would be otherwise be emitted to the atmosphere by producing chemicals and fuels from carbon dioxide and electricity. Significant progress has been made in the experimental performance of carbon dioxide reduction systems with novel catalyst designs, new materials, and systems engineering; however, no work has linked such changes in stack design and materials to capital costs for the stack itself. In this study, we present an analysis that accounts for and analyzes the impacts of alternative materials and system architectures on manufactured costs of carbon dioxide reduction stacks, thus providing a framework to understand exactly how these advances impact the at-scale capital costs of these systems. Specifically, we consider the impact that the addition of a catholyte buffer layer has on an electrolyzer reducing carbon dioxide to formate, finding that the cost of manufacturing this part only increases stack costs by about $30/m 2 at high manufacturing rates, while previous work finds that this part improves system performance. This work shows that the links between system performance, materials, and costs are nonlinear, and that achieving low-cost scalability requires optimization of not just performance parameters but also the use of low-cost and highly scalable materials. These results bridge experimental and techno-economic analysis of processes for carbon dioxide reduction, informing researchers by providing a quantifiable estimate of the impact of advances in electrochemical carbon dioxide reduction technology on manufactured stack capital costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Aerodynamic Analysis of a Spinning Missile with Dithering Canards

A generic spinning missile with dithering canards is used to demonstrate the utility of an overset structured grid approach for simulating the aerodynamics of rolling airframe missile systems. The approach is used to generate a modest aerodynamic database for the generic missile. The database is populated with solutions to the Euler and Navier-Stokes equations. It is used to evaluate grid resolution requirements for accurate prediction of instantaneous missile loads and the relative aerodynamic significance of angle-of-attack, canard pitching sequence, viscous effects, and roll-rate effects. A novel analytical method for inter- and extrapolation of database results is also given.

Meakin, Robert L.↗

Computational Analysis of Different Sparging Systems and their Influence in the Fluid-Dynamic Behavior of Bubble Column Reactors

Bubble column bioreactors are being actively considered for gas fermentation applications, specifically for CO2 utilization, and sugars to fuels conversion. Their main advantages include good mass transfer without any moving parts and low-cost of operation and maintenance. However, the design and scale-up of such reactors is challenging specifically for carbon capture applications where a mixture of gases (e.g. CO2/CO/H2) with variable solubilities is used. The overall performance of scaled-up bioreactors (e.g., mass transfer rate) is largely affected by gas holdup, bubble size distribution (BSD), and multiphase hydrodynamics. We investigate the effect of gas sparger designs on the performance of these large-scale bioreactors using computational fluid dynamics simulations in this work, so as to improve CO2 conversion at scale. The gas distribution systems in bubble column reactors not only determines operational regime, but also affects the evolution of the BSD, which in turn influences interfacial mass transfer and ultimately the efficiency of the gas-liquid exchange process. In addition to the BSD, uniformity in gas sparging affects gas holdup and bubble residence time which constitute important metrics of performance in gas-liquid systems. In this work, we use computational models to simulate high fidelity representations of different sparger designs and their effect on the operation of a bubble column reactor. Four different types of spargers have been selected for the computational study (Fig. 1): ladder, multi-ring, single-ring and toroidal. Their effect on superficial velocity, gas holdup mixing efficiency, and BSD will be evaluated in this work. The model uses a multiphase Eulerian framework similar to [1] and include a composition of mixtures of H2/CO/CO2 gases, common in fermentation applications.

BIOMASS FUELS,MATHEMATICS AND COMPUTING↗