Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “unit testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Development of a Low Cost 10kW Tubular SOFC Power System

The DOE program funded from 2003 through early 2013 has brought the Acumentrics SOFC program from an early stage R&D program to an entry level commercial product offering. The development work started as one of the main core teams under the DOE Solid State Energy Conversion Alliance (SECA) program administered by the National Energy Technology Laboratory (NETL) of the DOE. During the first phase of the program, lasting approximately 3-4 years, a 5kW machine was designed, manufactured and tested against the specification developed by NETL. This unit was also shipped to NETL for independent verification testing which validated all of the results achieved while in the laboratory at Acumentrics. The Acumentrics unit passed all criteria established from operational stability, efficiency, and cost projections. Passing of the SECA Phase I test allowed the program to move into Phase II of the program. During this phase, the overall objective was to further refine the unit meeting a higher level of performance stability as well as further cost reductions. During the first year of this new phase, the NETL SECA program was refocused towards larger size units and operation on coal gasification due to the severe rise in natural gas prices and refocus on the US supply of indigenous coal. At this point, the program was shifted to the U.S. DOE’s Energy Efficiency and Renewable Energy (EERE) division located in Golden, Colorado. With this shift, the focus remained on smaller power units operational on gaseous fuels for a variety of applications including micro combined heat and power (mCHP). To achieve this goal, further enhancements in power, life expectancy and reductions in cost were necessary. The past 5 years have achieved these goals with machines that can now achieve over 40% electrical efficiency and field units that have now operated for close to a year and a half with minimal maintenance. The following report details not only the first phase while under the SECA program and the key achievements but also the results while under EERE’s leadership and the transition to an early commercial product offering.

10 SYNTHETIC FUELS↗

Fast neutron irradiation capability in existing thermal test reactors

In today’s nuclear industry, momentum towards the design, licensing, and construction of advanced nuclear demonstration plants, including fast reactors, is at a remarkably high level. However, there are currently no dedicated fast spectrum irradiation test facilities in the United States to support the development of fast spectrum technologies. As a result, a unique situation is developing where most of these plants will likely be designed by leveraging historic nuclear material technologies, but where the further optimization and advancement is impeded by the lack of fast neutron irradiation test facilities. While these circumstances present a challenge, there are some near-term opportunities that, if seized, can still help develop advanced fast reactor materials to a meaningful level of readiness to support future commercial fast reactors. Here, in this paper, we assess the feasibility of using thermal neutron filtering materials in existing experiment positions in the Advanced Test Reactor (ATR) at Idaho National Laboratory and the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory to simulate fast reactor test environments for nonfuel test specimens. Items investigated include the incident neutron flux (both fast and thermal), the total neutron fluence and cumulative atom displacements, helium production rate due to thermal neutron capture in nickel, and the potential impact that the thermal neutron filter material has on the cycle length of a given reactor. It is concluded that while HFIR provides the highest fast flux of all the options investigated, it is limited in the amount of thermal neutron filtering material that can be introduced into an experiment position without significantly affecting the operation of the reactor. Irradiation in Outboard-A positions in the ATR was found to be the most realistic near-term experiment avenue due to having ample space for several capsules in a moderately fast flux.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design, Development, Pre-Testing and Preparation for Full Scale Cold Testing of a System for Field Remediation of Vertical Pipe Units at the Hanford Site 618-10 Burial Grounds -12495

At the Hanford site, in the 1950's and 60's, radioactive waste materials, including Transuranic (TRU) wastes from a number of laboratories were stored in vertical pipe units (VPUs) in what are now the 618-10 and 618-11 burial grounds. Although the current physical condition of the VPUs is unknown, initial R and D studies had shown that in-ground size reduction and stabilization of VPU contents was feasible. This paper describes the R and D work and testing activities to validate the concept of in-ground size reduction and stabilization of VPU contents, and the design and pre-testing of major plant items and augering systems on full size simulated VPUs. The paper also describes the full size prototype equipment which will be used in full size cold testing of simulated VPUs off the Hanford site, to prove the equipment, develop operating procedures, and train operators prior to deployment on site. Safe and effective field remediation, removal and disposal of the VPUs in the 600 area are critical to the success of the River Corridor Closure Contract at the U.S. Department of Energy's Hanford Site. Safe and effective field remediation, removal and disposal of the VPUs in the 600 area are critical to the success of the River Corridor Closure Contract at the U.S. Department of Energy's Hanford Site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Activity Waste Pretreatment System Bench-Scale Testing: Supporting Integrated Testing and Facility Safety Analyses - 17171

The Low Activity Waste Pretreatment System (LAWPS) is being designed to enable the direct feed of waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) facility to be immobilized. Prior to construction of the LAWPS, pilot-scale integrated testing of the key unit operations (crossflow filtration, ion exchange using spherical resorcinol-formaldehyde (sRF) resin) will be conducted by a team led by Washington River Protection Solutions (WRPS) to increase the technology maturation level of the facility's critical technology elements. As a part of this effort, Pacific Northwest National Laboratory (PNNL) has conducted a series of tests to perform two major objectives: (1) support pilot-scale integrated testing of the LAWPS by supplying information or performance data in advance of operating the pilot-scale facility (1/9. scale); and (2) collect data needed to establish or confirm assumptions/approaches planned for implementation in the LAWPS safety basis. The first objective was focused in two technical areas: developing simulants that are representative of expected waste feed and can be produced at larger scales, and using these simulants in a bench-scale crossflow filter to establish expected solid-liquid separation performance. The crossflow filter was also used to observe the efficacy (with respect to filter production rate) of selected operational strategies. The second objective also included two technical areas: measuring the effect of sRF resin on hydrogen generation rate under irradiation, and demonstrating that the planned hydrogen management approach is effective and robust. The hydrogen management strategy involves fluidization of the sRF resin bed in the ion exchange columns and recirculating the liquid, a scenario that is planned for testing at full column height. The full height tests at PNNL also supported full-scale IX column testing conducted as part of the technology maturation plan. The experimental approaches used at PNNL in these four technical areas are summarized and selected key preliminary results are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Test Reactor National Scientific User Facility Partnerships

In 2007, the United States Department of Energy designated the Advanced Test Reactor (ATR), located at Idaho National Laboratory, as a National Scientific User Facility (NSUF). This designation made test space within the ATR and post-irradiation examination (PIE) equipment at INL available for use by researchers via a proposal and peer review process. The goal of the ATR NSUF is to provide researchers with the best ideas access to the most advanced test capability, regardless of the proposer's physical location. Since 2007, the ATR NSUF has expanded its available reactor test space, and obtained access to additional PIE equipment. Recognizing that INL may not have all the desired PIE equipment, or that some equipment may become oversubscribed, the ATR NSUF established a Partnership Program. This program enables and facilitates user access to several university and national laboratories. So far, seven universities and one national laboratory have been added to the ATR NSUF with capability that includes reactor-testing space, PIE equipment, and ion beam irradiation facilities. With the addition of these universities, irradiation can occur in multiple reactors and post-irradiation exams can be performed at multiple universities. In each case, the choice of facilities is based on the user's technical needs. Universities and laboratories included in the ATR NSUF partnership program are as follows: (1) Nuclear Services Laboratories at North Carolina State University; (2) PULSTAR Reactor Facility at North Carolina State University; (3) Michigan Ion Beam Laboratory (1.7 MV Tandetron accelerator) at the University of Michigan; (4) Irradiated Materials at the University of Michigan; (5) Harry Reid Center Radiochemistry Laboratories at University of Nevada, Las Vegas; (6) Characterization Laboratory for Irradiated Materials at the University of Wisconsin-Madison; (7) Tandem Accelerator Ion Beam. (1.7 MV terminal voltage tandem ion accelerator) at the University of Wisconsin-Madison; (8) Illinois Institute of Technology (IIT) Materials Research Collaborative Access Team (MRCAT) beamline at Argonne National Laboratory's Advanced Photon Source; and (9) Nanoindenter in the University of California at Berkeley (UCB) Nuclear Engineering laboratory Materials have been analyzed for ATR NSUF users at the Advanced Photon Source at the MRCAT beam, the NIST Center for Neutron Research in Gaithersburg, MD, the Los Alamos Neutron Science Center, and the SHaRE user facility at Oak Ridge National Laboratory (ORNL). Additionally, ORNL has been accepted as a partner facility to enable ATR NSUF users to access the facilities at the High Flux Isotope Reactor and related facilities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Whole metagenome sequencing and 16S rRNA gene amplicon analyses reveal the complex microbiome responsible for the success of enhanced in-situ reductive dechlorination (ERD) of a tetrachloroethene-contaminated Superfund site

The North Railroad Avenue Plume (NRAP) Superfund site in New Mexico, USA exemplifies successful chlorinated solvent bioremediation. NRAP was the result of leakage from a dry-cleaning that operated for 37 years. The presence of tetrachloroethene biodegradation byproducts, organohalide respiring genera (OHRG), and reductive dehalogenase (rdh) genes detected in groundwater samples indicated that enhanced reductive dechlorination (ERD) was the remedy of choice. This was achieved through biostimulation by mixing emulsified vegetable oil into the contaminated aquifer. This report combines metagenomic techniques with site monitoring metadata to reveal new details of ERD. DNA extracts from groundwater samples collected prior to and at four, 23 and 39 months after remedy implementation were subjected to whole metagenome sequencing (WMS) and 16S rRNA gene amplicon (16S) analyses. The response of the indigenous NRAP microbiome to ERD protocols is consistent with results obtained from microcosms, dechlorinating consortia, and observations at other contaminated sites. WMS detects three times as many phyla and six times as many genera as 16S. Both techniques reveal abundance changes in Dehalococcoides and Dehalobacter that reflect organohalide form and availability. Methane was not detected before biostimulation but appeared afterwards, corresponding to an increase in methanogenic Archaea. Assembly of WMS reads produced scaffolds containing rdh genes from Dehalococcoides, Dehalobacter, Dehalogenimonas, Desulfocarbo, and Desulfobacula. Anaerobic and aerobic cometabolic organohalide degrading microbes that increase in abundance include methanogenic Archaea, methanotrophs, Dechloromonas, and Xanthobacter, some of which contain hydrolytic dehalogenase genes. Aerobic cometabolism may be supported by oxygen gradients existing in aquifer microenvironments or by microbes that produce O 2 via microbial dismutation. The NRAP model for successful ERD is consistent with the established pathway and identifies new taxa and processes that support this syntrophic process. This project explores the potential of metagenomic tools (MGT) as the next advancement in bioremediation.

59 BASIC BIOLOGICAL SCIENCES↗

Smart Monitoring and Diagnostic System (SMDS) for Packaged Air Conditioners and Heat Pumps for Small/Medium Commercial Buildings: Preparation for Commercialization: CRADA 478 [Abstract only]

This project will enable Pacific Northwest National Laboratory (PNNL) and industry partner, mCloud Technologies, to work collaboratively to ready the Smart Monitoring and Diagnostic System (SMDS) for commercial deployment and validate its performance under real-world conditions at field sites. This project will specifically focus on 1) implementing the SMDS algorithms in a scalable cloud-based software architecture, 2) designing new, innovative, complimentary commercial services based on the SMDS, 3) enhancing the SMDS energy and cost impact algorithms to reduce uncertainty in estimates, 4) determining the lower limits on SMDS performance degradation detection, 5) validating algorithm performance and default values of adjustable thresholds with existing data from controlled physical testing and from customer packaged air conditioners and heat pumps (commonly referred to as rooftop units or RTUs), 6) field testing to validate the system on multiple customer buildings in diverse environments, and 7) expanding field deployment to a larger set of mCloud’s customer buildings. Project results by validating, enhancing, and quantifying the performance of the SMDS will position mCloud, and potential future licensees, to implement the SMDS in commercial offerings that encourage and enable use of condition-based and predictive maintenance, leading to significant reductions in energy use and greenhouse gas emissions associated with space conditioning by RTUs. Furthermore, these enhancements will increase the value of the SMDS for users and increase the potential market for its use and impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sulfur-Modified Zero-Valent Iron for Remediation Applications at DOE Sites - 13600

Many DOE remediation sites have chemicals of concern that are compounds in higher oxidation states, which make them both more mobile and more toxic. The chemical reduction of these compounds both prevents the migration of these chemicals and in some cases reduces the toxicity. It has also been shown that zero-valent iron is a very effective substance to use in reducing oxygenated compounds in various treatment processes. These have included the treatment of halogenated hydrocarbons in the form volatile organic compounds used as solvents and pesticides. Zero-valent iron has also been used to reduce various oxidized metals such as chromium, arsenic, and mercury in order to immobilize them, decrease their toxicity, and prevent further transport. In addition, it has been used to immobilize or break down other non-metallic species such as selenium compounds and nitrates. Of particular interest at several DOE remediation sites is the fact that zero-valent iron is very effective in immobilizing several radioactive metals which are mobile in their oxidized states. These include both technetium and uranium. The main difficulty in using zero-valent iron has been its tendency to become inactive after relatively short periods of time. While it is advantageous to have the zero-valent iron particles as porous as possible in order to provide maximum surface area for reactions to take place, these pores can become clogged when the iron is oxidized. This is due to the fact that ferric oxide has a greater volume for a given mass than metallic iron. When the surfaces of the iron particles oxidize to ferric oxide, the pores become narrower and will eventually shut. In order to minimize the degradation of the chemical activity of the iron due to this process, a modification of zero-valent iron has been developed which prevents or slows this process, which decreases its effectiveness. It is called sulfur-modified iron, and it has been produced in high purity for applications in municipal water treatment applications. Sulfur-modified iron has been found to not only be an extremely economical treatment technology for municipal water supplies, where very large quantities of water must be treated economically, but it has also been demonstrated to immobilize technetium. It has the added benefit of eliminating several other harmful chemicals in water supplies. These include arsenic and selenium. In one large-scale evaluation study an integrated system implemented chemical reduction of nitrate with sulfur-modified iron followed by filtration for arsenic removal. The sulfur-modified iron that was used was an iron-based granular medium that has been commercially developed for the removal of nitrate, co-contaminants including uranium, vanadium and chromium, and other compounds from water. The independent study concluded that 'It is foreseen that the greatest benefit of this technology (sulfur-modified iron) is that it does not produce a costly brine stream as do the currently accepted nitrate removal technologies of ion exchange and reverse osmosis. This investigation confirmed that nitrate reduction via sulfur-modified iron is independent of the hydraulic loading rate. Future sulfur-modified iron treatment systems can be designed without restriction of the reactor vessel dimensions. Future vessels can be adapted to existing site constraints without being limited to height-to-width ratios that would exist if nitrate reduction were to depend on hydraulic loading rate'. Sulfur-modified iron was studied by the Pacific Northwest National Laboratory (PNNL) for its effectiveness in the reduction and permanent sequestration of technetium. The testing was done using Hanford Site groundwater together with sediment. The report stated, 'Under reducing conditions, TcO{sub 4} is readily reduced to TcIV, which forms highly insoluble oxides such at TcO{sub 2}.nH{sub 2}O. However, (re)oxidation of TcIV oxides can lead to remobilization. Under sulfidogenic conditions, most TcIV will be reduced and immobilized as Tc{sub 2}S{sub 7}, which is less readily re-mobilized, even under oxic conditions. This process should be favored by stimulation of sulfidogenic conditions'. The sulfur-modified iron provides the sulfur, together with the iron, to maintain this stable sequestration of technetium. As a result of these and other studies demonstrating the cost-effectiveness of sulfur-modified iron in treating technetium and other hazardous compounds in Hanford Site groundwater and its cost-effectiveness in reducing nitrate, the Richland Operations Office of the Department of Energy issued a change order to the Central Plateau Contractor providing for the testing of sulfur-modified iron in a mobile pilot unit at the Hanford Site. Further testing is anticipated to produce refinements in operating conditions and further optimization of the existing process. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

Low Activity Waste Pretreatment System Bench-Scale Testing: Supporting Integrated Testing and Facility Safety Analyses - 17171

The Low Activity Waste Pretreatment System (LAWPS) is being designed to enable the direct feed of waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) facility to be immobilized. Prior to construction of the LAWPS, pilot-scale integrated testing of the key unit operations (crossflow filtration, ion exchange using spherical resorcinol-formaldehyde (sRF) resin) will be conducted by a team led by Washington River Protection Solutions (WRPS) to increase the technology maturation level of the facility’s critical technology elements. As a part of this effort, Pacific Northwest National Laboratory (PNNL) has conducted a series of bench-scale (or engineering-scale) tests to perform two major objectives: (1) support pilot-scale integrated testing of the LAWPS by supplying information or performance data in advance of operating the pilot-scale facility; and (2) collect data needed to establish or confirm assumptions/approaches planned for implementation in the LAWPS safety basis. The first objective was focused in two technical areas: developing simulants that are representative of expected waste feed and can be produced at larger scales, and using these simulants in a bench-scale crossflow filter to establish expected solid-liquid separation performance. The crossflow filter was also used to observe the efficacy (with respect to filter production rate) of selected operational strategies. The second objective also included two technical areas: measuring the effect of sRF resin on hydrogen generation rate under irradiation, and demonstrating that the planned hydrogen management approach is effective and robust. The hydrogen management strategy involves fluidization of the sRF resin bed in the ion exchange columns and recirculating the liquid, a scenario that is planned for testing at full column height. The full height tests at PNNL also supported full-scale IX column testing conducted as part of the technology maturation plan. The experimental approaches used at PNNL in these four technical areas are summarized and selected key preliminary results are provided.

cross flow filtration↗

Truck Thermoacoustic Generator and Chiller

This Final Report describes the accomplishments of the US Department of Energy (DOE) cooperative agreement project DE-FC26-04NT42113 - Truck Thermoacoustic Generator and Chiller - whose goal is to design, fabricate and test a thermoacoustic piezoelectric generator and chiller system for use on over-the-road heavy-duty-diesel trucks, driven alternatively by the waste heat of the main diesel engine exhaust or by a burner integrated into the thermoacoustic system. The thermoacoustic system would utilize engine exhaust waste heat to generate electricity and cab air conditioning, and would also function as an auxiliary power unit (APU) for idle reduction. The unit was to be tested in Volvo engine performance and endurance test cells and then integrated onto a Class 8 over-the-road heavy-duty-diesel truck for further testing on the road. The project has been a collaboration of The Pennsylvania State University Applied Research Laboratory, Los Alamos National Laboratory, Clean Power Resources Inc., and Volvo Powertrain (Mack Trucks Inc.). Cost share funding was provided by Applied Research Laboratory, and by Clean Power Resources Inc via its grant from Innovation Works - funding that was derived from the Commonwealth of Pennsylvania. Los Alamos received its funding separately through DOE Field Work Proposal 04EE09.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Radon Results in 4- Versus 6-Plex Townhouse Units

In this work, to determine whether there were any significant differences in radon frequency between 4-unit (4-plex) and 6- unit (6-plex) multifamily buildings, an analysis was performed on three different populations of townhouses: one located within an Environmental Protection Agency (EPA) Radon Zone 1 site (Population A) and two others, both located in an EPA Radon Zone 3 site (Populations B and C). Within their respective population grouping, all units were two stories, identical in construction and floor plan, and were constructed by the same contractor over a 1- to 2-year period. In addition, each unit had its own separate, ducted forced-air heat pump. Long-term radon testing was performed using alpha track detectors (ATDs) for a period of 180 days. All detectors were placed in accordance with EPA residential sampling protocols (EPA 402-R-92-003) along the centerline of each unit. Followup testing (short-term, 7-day electret) was performed in all units in which the ATD test results were ≥4 pCi/L, and all elevated results were confirmed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Needs and Opportunities for Testing of Hydropower Technology Innovations

Despite hydropower’s status as a well-established technology, changes in the global energy sector have prompted a variety of necessary hydropower technological innovations. Examples include efficient lowhead turbines, more flexible and dispatchable hydropower and pumped storage systems to complement variable and intermittent renewable resources, and technologies providing higher environmental performance. However, while innovative technologies are currently being proposed to meet these development challenges, small hydropower facility owners do not have sufficient risk-bearing capacity to adopt new, unvalidated technologies. This discourages manufacturers from bringing nascent technologies to market and stalls the technological growth of the sector. To reduce the risks associated with new technologies and promote further innovation, systemic (and sometimes unconventional) validation activities and new testing capabilities for hydropower are highly desired. These testing capabilities must demonstrate the safety, environmental acceptability, reliability, and performance of innovative technologies to quantify their value compared with existing technologies. Establishing these capabilities through dedicated testing facilities will be key to promoting hydropower growth in the United States. Following direction from the House Energy and Water Development Committee, the US Department of Energy’s Water Power Technologies Office (WPTO) has been tasked with understanding the state of hydropower testing in the United States. This scoping report discusses the needs and opportunities of hydropower testing in the United States, with a specific focus on small hydropower. Future developments will likely mostly target low-head sites with less than 30 ft (9.1 m) from new stream-reach developments, non-powered dam retrofits, and rehabilitation/upgrade of existing plants.

13 HYDRO ENERGY↗

Existing and Past Methods of Test and Rating Standards Related to Integrated Heat Pump Technologies

This report evaluates existing and past US methods of test and rating standards related to electrically operated air, water, and ground source air conditioners and heat pumps, 65,000 Btu/hr and under in capacity, that potentiality incorporate a potable water heating function. Two AHRI (formerly ARI) standards and three DOE waivers were identified as directly related. Six other AHRI standards related to the test and rating of base units were identified as of interest, as they would form the basis of any new comprehensive test procedure. Numerous other AHRI and ASHRAE component test standards were also identified as perhaps being of help in developing a comprehensive test procedure.

Reedy, Wayne R.↗

Melt Rate Enhancement for High Aluminum HLW Glass Formulation (Final Report)

The principal objective of the work reported here was to develop and identify HLW glass compositions that maximize waste processing rates for the aluminum limted waste composition specified by ORP while maintaining high waste loadings and acceptable glass properties. This was accomplished through a combination of crucible-scale tests, confirmation tests on the DM100 melter system, and demonstration at pilot scale (DM1200). The DM100-BL unit was selected for these tests since it was used previously with the HLW waste streams evaluated in this study, was used for tests on HLW glass compositions to support subsequent tests on the HLW Pilot Melter, conduct tests to determine the effect of various glass properties (viscosity and conductivity) and oxide concentrations on glass production rates with HLW feed streams, and to assess the volatility of cesium and technetium during the vitrification of an HLW AZ-102 composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Analysis of FFTF Loss-of-Flow Tests with SAS4A/SASSYS-1

The Fast Flux Test Facility (FFTF) was the most recent Sodium-cooled Fast Reactor (SFR) built in the United States. The Passive Safety Test (PST) program was carried out on FFTF between 1984 and 1986 to demonstrate the capability of passive reactor shutdown and decay heat removal in response to protected and unprotected transients. In order to recover the information and knowledge that has been gained from FFTF, a research project was initiated focusing on the simulation of Unprotected Loss of Flow Without Scram (LOFWOS) tests similar to the knowledge preservation activities conducted for EBR-II by Argonne National Laboratory in earlier years. These knowledge preservation activities are intended to support the validation of computational tools and methods in the area of SFR passive safety. Comparisons with experimental data and other safety codes provide opportunities to improve SFR design and safety analysis codes and methods.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Case Study of Envelope Sealing in Existing Multiunit Structures

Envelope air sealing was included in the retrofit of a 244 unit low-rise multifamily housing complex in Durham, N.C. Pre- and post-retrofit enclosure leakage tests were conducted on 51 units and detailed diagnostics were performed on 16. On average, total leakage was reduced by nearly half, from 19.7 ACH50 to 9.4 ACH50. Costs for air sealing were $\$$0.31 per square foot of conditioned floor area,lower than estimates found in the National Residential Efficiency Measures Database (NREMD) and other sources, perhaps due in part to the large-scale production nature of the project. Modeling with BEopt software -- using an estimate of 85% of the envelope air leakage going to the outside (based on guarded tests performed at the site) -- calculated a space conditioning energy cost savings of 15%to 21% due to the air sealing retrofit. Important air leakage locations identified included plumbing and electrical penetrations, dropped ceilings/soffits, windows, ducts and wall-to-floor intersections. Previous repair activity had created significant leakage locations as well. Specifications and a pictorial guide were developed for contractors performing the work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Graphene oxide coated side polished surface plasmon resonance optical fibre sensor with varying polishing losses

Four batches of side-polished SMF optical fibres with different polishing losses, − 0.5 dBm, − 5 dBm, − 10 dBm and − 15 dBm were coated with a graphene oxide layer of ~ 0.5 μm via drop casting. TE polarized light was propagated through the light during experiments and four different transformer oils with different water contents were dropped onto the sensor. The drop in the power of transmitted light was recorded. The responses of the sensors showed good linearity for all, but the least polished fibre showed the weakest response in terms of power drop towards change in concentration. The − 5 dBm fibre showed the best response per unit concentration change. Additional tests showed the increased response for a GO coated side polished sensor compared to an uncoated side polished sensor. Simulation using COMSOL was performed to show the effects on the electric field of a sensor with and without GO coating. Another set of simulations were performed to show the effects of reducing cladding thickness on the coupling of the electric field. Simulations show that the optimal cladding thickness is not the most polished fibre, coinciding with our results that − 15 dBm loss fibre did not show the most response per unit change in the analyte.

77 NANOSCIENCE AND NANOTECHNOLOGY↗