Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “uncertainty relation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

CMOS Integrated Single Electron Transistor Electrometry (CMOS-SET) circuit design for nanosecond quantum-bit read-out.

Novel single electron transistor (SET) read-out circuit designs are described. The circuits use a silicon SET interfaced to a CMOS voltage mode or current mode comparator to obtain a digital read-out of the state of the qubit. The design assumes standard submicron (0.35 um) CMOS SOI technology using room temperature SPICE models. Implications and uncertainties related to the temperature scaling of these models to 100mK operation are discussed. Using this technology, the simulations predict a read-out operation speed of approximately Ins and a power dissipation per cell as low as 2nW for single-shot read-out, which is a significant advantage over currently used radio frequency SET (RF-SET) approaches.

42 ENGINEERING↗

INTEGRATION OF SYSTEM COMPONENTS AND UNCERTAINTY ANALYSIS - HANFORD EXAMPLES

{sm_bullet} Deterministic 'One Off' analyses as basis for evaluating sensitivity and uncertainty relative to reference case {sm_bullet} Spatial coverage identical to reference case {sm_bullet} Two types of analysis assumptions - Minimax parameter values around reference case conditions - 'What If' cases that change reference case condition and associated parameter values {sm_bullet} No conclusions about likelihood of estimated result other than' qualitative expectation that actual outcome should tend toward reference case estimate

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multifidelity Monte Carlo estimation for efficient uncertainty quantification in climate-related modeling

Abstract. Uncertainties in an output of interest that depends on the solution of a complex system (e.g., of partial differential equations with random inputs) are often, if not nearly ubiquitously, determined in practice using Monte Carlo (MC) estimation. While simple to implement, MC estimation fails to provide reliable information about statistical quantities (such as the expected value of the output of interest) in application settings such as climate modeling, for which obtaining a single realization of the output of interest is a costly endeavor. Specifically, the dilemma encountered is that many samples of the output of interest have to be collected in order to obtain an MC estimator that has sufficient accuracy – so many, in fact, that the available computational budget is not large enough to effect the number of samples needed. To circumvent this dilemma, we consider using multifidelity Monte Carlo (MFMC) estimation which leverages the use of less costly and less accurate surrogate models (such as coarser grids, reduced-order models, simplified physics, and/or interpolants) to achieve, for the same computational budget, higher accuracy compared to that obtained by an MC estimator – or, looking at it another way, an MFMC estimator obtains the same accuracy as the MC estimator at lower computational cost. The key to the efficacy of MFMC estimation is the fact that most of the required computational budget is loaded onto the less costly surrogate models so that very few samples are taken of the more expensive model of interest. We first provide a more detailed discussion about the need to consider an alternative to MC estimation for uncertainty quantification. Subsequently, we present a review, in an abstract setting, of the MFMC approach along with its application to three climate-related benchmark problems as a proof-of-concept exercise.

54 ENVIRONMENTAL SCIENCES↗

NASA Team 2 Sea Ice Concentration Algorithm Retrieval Uncertainty

Satellite microwave radiometers are widely used to estimate sea ice cover properties (concentration, extent, and area) through the use of sea ice concentration (IC) algorithms. Rare are the algorithms providing associated IC uncertainty estimates. Algorithm uncertainty estimates are needed to assess accurately global and regional trends in IC (and thus extent and area), and to improve sea ice predictions on seasonal to interannual timescales using data assimilation approaches. This paper presents a method to provide relative IC uncertainty estimates using the enhanced NASA Team (NT2) IC algorithm. The proposed approach takes advantage of the NT2 calculations and solely relies on the brightness temperatures (TBs) used as input. NT2 IC and its associated relative uncertainty are obtained for both the Northern and Southern Hemispheres using the Advanced Microwave Scanning Radiometer for the Earth Observing System (AMSR-E) TB. NT2 IC relative uncertainties estimated on a footprint-by-footprint swath-by-swath basis were averaged daily over each 12.5-km grid cell of the polar stereographic grid. For both hemispheres and throughout the year, the NT2 relative uncertainty is less than 5%. In the Southern Hemisphere, it is low in the interior ice pack, and it increases in the marginal ice zone up to 5%. In the Northern Hemisphere, areas with high uncertainties are also found in the high IC area of the Central Arctic. Retrieval uncertainties are greater in areas corresponding to NT2 ice types associated with deep snow and new ice. Seasonal variations in uncertainty show larger values in summer as a result of melt conditions and greater atmospheric contributions. Our analysis also includes an evaluation of the NT2 algorithm sensitivity to AMSR-E sensor noise. There is a 60% probability that the IC does not change (to within the computed retrieval precision of 1%) due to sensor noise, and the cumulated probability shows that there is a 90% chance that the IC varies by less than +/-3%. We also examined the daily IC variability, which is dominated by sea ice drift and ice formation/melt. Daily IC variability is the highest, year round, in the MIZ (often up to 20%, locally 30%). The temporal and spatial distributions of the retrieval uncertainties and the daily IC variability is expected to be useful for algorithm intercomparisons, climate trend assessments, and possibly IC assimilation in models.

Sea Ice↗

Run-09 pC polarimeter analysis

Analysis of PC polarimeter data at {radical}s = 200 and 500 GeV from Run9 is presented. Final polarization results, fill-by-fill, for blue and yellow beams, as to be used by RHIC experiments (in collisions) are released and collected in http://www4.rcf.bnl.gov/cnipol/pubdocs/Run09Offline/. Global relative systematic uncertainties {delta}P/P (to be considered as correlated from fill to fill) are 4.7% for 100 GeV beams, and 8.3% (12.1%) for blue (yellow) 250 GeV beams. For a product of two beam polarizations P{sub B} {center_dot} P{sub Y} (used in double spin asymmetry measurements) the relative uncertainty {delta}(P{sub B} {center_dot} P{sub Y})/(P{sub B} {center_dot} P{sub Y}) 8.8% for 100 GeV beams and 18.5% for 250 GeV beams. For the average between two beam polarization (P{sub B} + P{sub Y})/2 (used in single spin asymmetry measurements, when data from two polarized beams are combined) the relative uncertainty is 4.4% for 100 GeV beams and 9.2% for 250 GeV beams. Larger uncertainties for 250 GeV beams relate to significant rate related systematic effects experienced in the first part of Run9 (due to thicker targets used and smaller trans. beam size at higher beam energy).

43 PARTICLE ACCELERATORS↗

Partitioning uncertainty in projections of Arctic sea ice

Abstract Improved knowledge of the contributing sources of uncertainty in projections of Arctic sea ice over the 21st century is essential for evaluating impacts of a changing Arctic environment. Here, we consider the role of internal variability, model structure and emissions scenario in projections of Arctic sea-ice area (SIA) by using six single model initial-condition large ensembles and a suite of models participating in Phase 5 of the Coupled Model Intercomparison Project. For projections of September Arctic SIA change, internal variability accounts for as much as 40%–60% of the total uncertainty in the next decade, while emissions scenario dominates uncertainty toward the end of the century. Model structure accounts for 60%–70% of the total uncertainty by mid-century and declines to 30% at the end of the 21st century in the summer months. For projections of wintertime Arctic SIA change, internal variability contributes as much as 50%–60% of the total uncertainty in the next decade and impacts total uncertainty at longer lead times when compared to the summertime. In winter, there exists a considerable scenario dependence of model uncertainty with relatively larger model uncertainty under strong forcing compared to weak forcing. At regional scales, the contribution of internal variability can vary widely and strongly depends on the calendar month and region. For wintertime SIA change in the Greenland-Iceland-Norwegian and Barents Seas, internal variability contributes 60%–70% to the total uncertainty over the coming decades and remains important much longer than in other regions. We further find that the relative contribution of internal variability to total uncertainty is state-dependent and increases as sea ice volume declines. These results demonstrate that internal variability is a significant source of uncertainty in projections of Arctic sea ice.

Bonan, David B. (ORCID:0000000338676009)↗

Novel Approach for Evaluating Detector Systematics in the MicroBooNE LArTPC

One of the primary challenges in current and future precision neutrino experiments using liquid argon time projection chambers (LArTPCs) is understanding detector effects and quantifying the associated systematic uncertainties. MicroBooNE has pioneered the evaluation of detector-related systematic uncertainties for such experiments. This note presents a novel technique for assessing detector systematics based on low-level comparisons between data and simulation. The method can be used to better understand detector-related uncertainties while remaining agnostic to the details of the detector model in simulation. We believe similar approaches could be applied to future LArTPC experiments, including SBN and DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localization of infrasonic sources via Bayesian back projection

SUMMARY A Bayesian framework is investigated for event-specific localization of infrasonic sources using back projection ray tracing. Direction-of-arrival information from array-based detection analysis is used to initialize a back projection ray path originating from the detecting array location and quantifying propagation characteristics from hypothetical source locations. The Fisher statistic, computed from the array’s beam coherence, is mapped into uncertainty in the launch angles of the ray path. Auxiliary parameters previously introduced for solving the Transport equation to compute geometric spreading along ray paths are used to map uncertainty in the ray launch angles into spatial and temporal uncertainties in the ray path. An atmospheric ensemble approach is applied to account for atmospheric uncertainty, and the relation between uncertainties in the atmospheric state and confidence in estimated localization are evaluated using several ensembles with specified variances. The method is evaluated using a synthetic event in the western United States constructed via forward propagation simulations as well as a single-station, multi-arrival detection from a surface explosion in the western United States. Localization results using this event-specific approach are more accurate and exhibit improved precision than existing Bayesian localization methods that leverage generalized, pre-computed propagation statistics.

58 GEOSCIENCES↗

Quantifying Effects of Departure and Flight Time Uncertainty on Urban Air Mobility Operations

Demand capacity balancing is a key mechanism for maintaining safe and efficient Urban Air Mobility (UAM) operations. However, uncertainties such as departure delays and flight time variation may reduce the effectiveness of algorithms used for balancing and detrimentally impact the safety and efficiency of UAM operations. In this paper, the effects of these uncertainties on UAM operations are quantified by modeling a distribution of departure and flight time errors. A route network in the Dallas/Fort Worth metropolitan area was used to simulate traffic demand with and without uncertainty. Simulations were conducted with three main models of uncertainty – first uncertainty in departure time delay resulting in late takeoffs, second with uncertainty in flight times in addition to departure delays, and finally, uncertainty in departure times that cause either late or early takeoffs. Each of these simulations were performed using varied standard deviations to fully understand the effects of uncertainties. Results from these simulations were compared to a baseline simulation using the same parameters, but without any uncertainty. The results suggest that both safety and efficiency are significantly impacted by uncertainty even with relatively low uncertainty introduced. These results work towards quantifying the effects of uncertainty in flight scheduling for UAM. They will also aid in the further development of the demand capacity balancing algorithms for UAM operations and associated air traffic management.

Urban Air Mobility↗

Quantifying the Effects of Departure and Flight Time Uncertainty on Urban Air Mobility Operations

Demand capacity balancing is a key mechanism for maintaining safe and efficient Urban Air Mobility (UAM) operations. However, uncertainties such as departure delays and flight time variation may reduce the effectiveness of algorithms used for balancing and detrimentally impact the safety and efficiency of UAM operations. In this paper, the effects of these uncertainties on UAM operations are quantified by modeling a distribution of departure and flight time errors. A route network in the Dallas/Fort Worth metropolitan area was used to simulate traffic demand with and without uncertainty. Simulations were conducted with three main models of uncertainty – first uncertainty in departure time delay resulting in late takeoffs, second with uncertainty in flight times in addition to departure delays, and finally, uncertainty in departure times that cause either late or early takeoffs. Each of these simulations were performed using varied standard deviations to fully understand the effects of uncertainties. Results from these simulations were compared to a baseline simulation using the same parameters, but without any uncertainty. The results suggest that both safety and efficiency are significantly impacted by uncertainty even with relatively low uncertainty introduced. These results work towards quantifying the effects of uncertainty in flight scheduling for UAM. They will also aid in the further development of the demand capacity balancing algorithms for UAM operations and associated air traffic management.

Urban Air Mobility↗

Reactor simulations with nuclear data uncertainties

This work demonstrates the influence of uncertainties in microscopic nuclear data on the results of reactor simulations, both for stationary and transient states. It gives an overview on the methods in use for uncertainty and sensitivity analyses with respect to nuclear data, and discusses the pros and cons. For full-scale reactor simulations, in particular with coupled neutron transport and thermo-hydraulics, random sampling provides a powerful means to propagate nuclear data uncertainties through the complete calculation sequence. Results of uncertainty analyses performed with the GRS XSUSA – “cross section (XS) Uncertainty and Sensitivity Analysis” methodology are shown for radial power distributions from steady-state PWR calculations and for the time evolution of the reactor power in the course of a control rod withdrawal from a PWR mini-core. In all cases, the output uncertainties are considerable. For the radial power distributions, relative 1σ uncertainties of up to 10% are observed, and for the power peak during the transient, the relative 1σ uncertainty reaches 20%. These large uncertainties strongly suggest to routinely accompany best-estimate simulations by uncertainty analyses with respect to nuclear data, in particular for systems beyond LWR for which much less operation experience is available.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calibration of EBT2 film using a red-channel PDD method in combination with a modified three-channel technique

Purpose: Ashland Inc. EBT2 and EBT3 films are widely used in quality assurance for radiation therapy; however, there remains a relatively high degree of uncertainty [B. Hartmann, M. Martisikova, and O. Jakel, “Homogeneity of Gafchromic EBT2 film,” Med. Phys. 37, 1753–1756 (2010)]. Micke et al. (2011) recently improved the spatial homogeneity using all color channels of a flatbed scanner; however, van Hoof et al. (2012) pointed out that the corrected nonuniformity still requires further investigation for larger fields. To reduce the calibration errors and the uncertainty, the authors propose a new red-channel percentage-depth-dose method in combination with a modified three-channel technique. Methods: For the ease of comparison, the EBT2 film image used in the authors’ previous study (2012) was reanalyzed using different approaches. Photon beams of 6-MV were delivered to two different films at two different beam on times, resulting in the absorption doses of ranging from approximately 30 to 300 cGy at the vertical midline of the film, which was set to be coincident with the central axis of the beam. The film was tightly sandwiched in a 30{sup 3}-cm{sup 3} polystyrene phantom, and the pixel values for red, green, and blue channels were extracted from 234 points on the central axis of the beam and compared with the corresponding depth doses. The film was first calibrated using the multichannel method proposed by Micke et al. (2010), accounting for nonuniformities in the scanner. After eliminating the scanner and dose-independent nonuniformities, the film was recalibrated via the dose-dependent optical density of the red channel and fitted to a power function. This calibration was verified via comparisons of the dose profiles extracted from the films, where three were exposed to a 60° physical wedge field and three were exposed to composite fields, and all of which were measured in a water phantom. A correction for optical attenuation was implemented, and treatment plans of intensity modulated radiation therapy and volumetric modulated arc therapy were evaluated. Results: The method described here demonstrated improved accuracy with reduced uncertainty. The relative error compared with the measurements of a water phantom was less than 1%, and the overall calibration uncertainty was less than 2%. Verification tests revealed that the results were close to those of the authors’ previous study, and all differences were within 3%, except those with a high-dose gradient. The gamma pass rates (2%/2 mm) of the treatment plan evaluated using the method described here were greater than 99%, and no obvious stripe patterns were observed in the dose-difference maps. Conclusions: Spatial homogeneity was significantly improved via the calibration method described here. This technique is both convenient and time-efficient because it does not require cutting the film, and only two exposures are necessary.

60 APPLIED LIFE SCIENCES↗

Providing radiometric traceability for the calibration home base of DLR by PTB

A dedicated calibration technique was applied for the calibration of the spectral radiance transfer standard (RASTA) of the German Aerospace Center (DLR) at the Physikalisch-Technische Bundesanstalt (PTB), consisting of two independent but complementing calibration procedures to provide redundancy and smallest possible calibration uncertainties. Procedure I included two calibration steps: In a first step the optical radiation source of RASTA, an FEL lamp, was calibrated in terms of its spectral irradiance E{sub {lambda}}({lambda}) in the wavelength range from 350 nm to 2400 nm using the PTB Spectral Irradiance Calibration Equipment (SPICE), while in a second step the spectral radiance factor {beta}{sub 0 Degree-Sign :45 Degree-Sign }({lambda}) of the RASTA reflection standard was calibrated in a 0 Degree-Sign :45 Degree-Sign -viewing geometry in the wavelength range from 350 nm to 1700 nm at the robot-based gonioreflectometer facility of PTB. The achieved relative standard uncertainties (k= 1) range from 0.6 % to 3.2 % and 0.1 % to 0.6 % respectively. Procedure II was completely independent from procedure I and allowed to cover the entire spectral range of RASTA from 350 nm to 2500 nm. In the second procedure, the 0 Degree-Sign :45 Degree-Sign -viewing geometry spectral radiance L{sub {lambda},0 Degree-Sign :45 Degree-Sign }({lambda}) of RASTA was directly calibrated at the Spectral Radiance Comparator Facility (SRCF) of PTB. The relative uncertainties for this calibration procedure range from 0.8 % in the visible up to 7.5 % at 2500 nm (k= 1). In the overlapping spectral range of both calibration procedures the calculated spectral radiance L{sub {lambda},0 Degree-Sign :45 Degree-Sign ,calc}({lambda}) from procedure I is in good agreement with the direct measurement of procedure II, i.e. well within the combined expanded uncertainties (k= 2) of both procedures.

43 PARTICLE ACCELERATORS↗

A COMPREHENSIVE ANALYSIS OF UNCERTAINTIES AFFECTING THE STELLAR MASS-HALO MASS RELATION FOR 0 < z < 4

We conduct a comprehensive analysis of the relationship between central galaxies and their host dark matter halos, as characterized by the stellar mass-halo mass (SM-HM) relation, with rigorous consideration of uncertainties. Our analysis focuses on results from the abundance matching technique, which assumes that every dark matter halo or subhalo above a specific mass threshold hosts one galaxy. We provide a robust estimate of the SM-HM relation for 0 < z < 1 and discuss the quantitative effects of uncertainties in observed galaxy stellar mass functions (including stellar mass estimates and counting uncertainties), halo mass functions (including cosmology and uncertainties from substructure), and the abundance matching technique used to link galaxies to halos (including scatter in this connection). Our analysis results in a robust estimate of the SM-HM relation and its evolution from z = 0 to z = 4. The shape and the evolution are well constrained for z < 1. The largest uncertainties at these redshifts are due to stellar mass estimates (0.25 dex uncertainty in normalization); however, failure to account for scatter in stellar masses at fixed halo mass can lead to errors of similar magnitude in the SM-HM relation for central galaxies in massive halos. We also investigate the SM-HM relation to z = 4, although the shape of the relation at higher redshifts remains fairly unconstrained when uncertainties are taken into account. We find that the integrated star formation at a given halo mass peaks at 10%-20% of available baryons for all redshifts from 0 to 4. This peak occurs at a halo mass of 7 x 10{sup 11} M{sub sun} at z = 0 and this mass increases by a factor of 5 to z = 4. At lower and higher masses, star formation is substantially less efficient, with stellar mass scaling as M{sub *} {approx} M {sup 2.3}{sub h} at low masses and M{sub *} {approx} M {sup 0.29}{sub h} at high masses. The typical stellar mass for halos with mass less than 10{sup 12} M{sub sun} has increased by 0.3-0.45 dex for halos since z {approx} 1. These results will provide a powerful tool to inform galaxy evolution models.

79 ASTRONOMY AND ASTROPHYSICS↗

A Novel Approach to Postmastectomy Radiation Therapy Using Scanned Proton Beams

Purpose: Postmastectomy radiation therapy (PMRT), currently offered at Massachusetts General Hospital, uses proton pencil beam scanning (PBS) with intensity modulation, achieving complete target coverage of the chest wall and all nodal regions and reduced dose to the cardiac structures. This work presents the current methodology for such treatment and the ongoing effort for its improvements. Methods and Materials: A single PBS field is optimized to ensure appropriate target coverage and heart/lung sparing, using an in–house-developed proton planning system with the capability of multicriteria optimization. The dose to the chest wall skin is controlled as a separate objective in the optimization. Surface imaging is used for setup because it is a suitable surrogate for superficial target volumes. In order to minimize the effect of beam range uncertainties, the relative proton stopping power ratio of the material in breast implants was determined through separate measurements. Phantom measurements were also made to validate the accuracy of skin dose calculation in the treatment planning system. Additionally, the treatment planning robustness was evaluated relative to setup perturbations and patient breathing motion. Results: PBS PMRT planning resulted in appropriate target coverage and organ sparing, comparable to treatments by passive scattering (PS) beams but much improved in nodal coverage and cardiac sparing compared to conventional treatments by photon/electron beams. The overall treatment time was much shorter than PS and also shorter than conventional photon/electron treatment. The accuracy of the skin dose calculation by the planning system was within ±2%. The treatment was shown to be adequately robust relative to both setup uncertainties and patient breathing motion, resulting in clinically satisfying dose distributions. Conclusions: More than 25 PMRT patients have been successfully treated at Massachusetts General Hospital by using single-PBS fields. The methodology and robustness of both the setup and the treatment have been discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Executive summary of error sources in dynamic surface temperature measurements

Obtaining bulk T requires measuring apparent sample interface T surface , knowledge of any window conditions T window , and knowledge of thermal transport from the sample to the window. To obtain bulk T with uncertainties below 5% requires relatively small uncertainties in each of these areas, and large uncertainties in one area require smaller uncertainties in others to maintain the error budget. For example, if T window is known to 10%, a 5% total uncertainty can be obtained if T surface is known to 1% and combined transport uncertainties are known to 20%. If T surface can only be measured to 2%, combined transport uncertainties must be 17% to reach the same overall uncertainty. As the form of transport is unknown at high pressure, and window temperatures are difficult to measure by their very nature, reducing surface T uncertainties is the practical first step. Here we will discuss various error sources in the measurement of apparent T surface , and which ones must be correctly obtained prior to the experiment.

36 MATERIALS SCIENCE↗