Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Ultrasensitive Photothermal Spectroscopy: Harnessing the Seebeck Effect for Attogram-Level Detection

Molecular-level spectroscopy is crucial for sensing and imaging applications, yet detecting and quantifying minuscule quantities of chemicals remain a challenge, especially when they surface adsorb in low numbers. Here, we introduce a photothermal spectroscopic technique that enables the high selectivity sensing of adsorbates with an attogram detection limit. Our approach utilizes the Seebeck effect in a microfabricated nanoscale thermocouple junction, incorporated into the apex of a microcantilever. We observe minimal thermal mass exhibited by the sensor, which maintains exceptional thermal insulation. The temperature variation driving the thermoelectric junction arises from the nonradiative decay of molecular adsorbates’ vibrational states on the tip. We demonstrate the detection of photothermal spectra of physisorbed trinitrotoluene (TNT) and dimethyl methylphosphonate (DMMP) molecules, as well as representative polymers, with an estimated mass of 10 -18 g.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature and Pressure Instrumentation for LYNM PE1 Chemical Explosive Testing

Underground chemical explosive testing has been conducted at the Nevada National Security Site under the Physics Experiment 1 (PE1) to validate explosive computer modeling and, ultimately, improve the accuracy of subsurface explosive detection. This SAND Report describes the dynamic temperature and pressure measurements within the chamber induced by the chemical explosive for the first of three experiments, PE1-A. The report details the instrumentation used for the experiment, the emplacement of the hardware, and the measured results. Dynamic temperature measurements were accomplished with the use of optical spectrometers and dynamic pressure was measured with a series of high-rated pressure transducers. This report includes details of the design and results of four cavity sensor systems used to measure early-time temperature, early-time pressure, late-time temperature, and late time pressure. The outcomes of PE1-A were used to inform the design of the remaining PE1 series experiments, PE1-B and PE1-DL.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Integrating Radio-Over-Fiber Communication System and BOTDR Sensor System

In this paper, we propose and experimentally demonstrate for the first time, the integration of a radio-over-fiber (RoF) communication system and a Brillouin optical time-domain reflectometry (BOTDR) distributed sensor system using a single optical fiber link. In this proof-of-concept integrated system, the communication system is composed of three modulation formats of quadrature phase-shift keying (QPSK), 16-quadrature amplitude modulation (16-QAM) and 64-QAM, which are modulated onto an orthogonal frequency division multiplexing (OFDM) signal. Whereas, the BOTDR sensor system is used for strain and/or temperature monitoring over the fiber distance with a spatial resolution of 5 m using a 25 km single-mode silica fiber. The error vector magnitude (EVM) is analyzed in three modulation formats in the presence of various BOTDR input pump powers. Using QPSK modulation, optimized 18 dBm sensing and 10 dBm data power, the measured EVM values with and without bandpass filter are 3.5% and 14.5%, respectively. The proposed system demonstrates a low temperature measurement error (±0.49 °C at the end of 25 km) and acceptable EVM values, which were within the 3GPP requirements. The proposed integrated system can be effectively applied for practical applications, which significantly reduces the fiber infrastructure cost by effective usage of a single optical fiber link.

42 ENGINEERING↗

COMPASS-FME Synoptic Sites Level 1 Sensor Data v1-2

This is the version 1-2 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our synoptic field sites. COMPASS-FME is studying sites in two distinct regions, the Chesapeake Bay and the Western Lake Erie Basin. We established the network at seven "synoptic" (observational) sites along the Chesapeake Bay and Lake Erie coastlines, collectively generating over three million observations per month, to track and comprehend environmental changes where land and water intersect. Additionally, the two regions provide an interesting contrast of saltwater and freshwater coasts that allow us to differentiate the impacts of inundation and coastal water chemistries in two nationally important coastal systems.L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds and out-of-service flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project**This dataset includes:- An overall dataset README file that describes the current version, gives citation and contact information, etc.- Site- and year-specific folders, each holding up to 12 CSV (comma separated value) data files for each site and plot in that year.- Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, as well as a general description of the site.- Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes. Please see v1-2 Synoptic L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning.

54 ENVIRONMENTAL SCIENCES↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Unravelling the sintering temperature-induced phase transformations in Ba(Fe 0.7 Ta 0.3 )O 3-δ ceramics

This work reports on the fundamental details of the crystal structure and phase transformations in Ba(Fe 0.7 Ta 0.3 )O 3-δ , the best known temperature-independent oxygen-sensing ceramic material for applications in extreme environments. Ba(Fe 0.7 Ta 0.3 )O 3-δ ceramics were synthesized using conventional solid-state ceramic reaction under variable sintering temperatures (T s = 1200–1350 °C). Combined X-ray diffraction (XRD) and high-resolution transmission electron microscopy (TEM) measurements revealed the T s -induced phase transformations and their origin in Ba(Fe 0.7 Ta 0.3 )O 3-δ . Associated with phase transformations, pseudo-cubic (PC) reflections, such as {200} PC , {211} PC , and {220} PC , exhibited distinct anomalies with increasing T s . At T s = 1200 °C, Ba(Fe 0.7 Ta 0.3 )O 3-δ stabilized in mixed orthorhombic + rhombohedral phases (Amm2 + R3m). With increasing T s (≥1250 °C), Ba(Fe 0.7 Ta 0.3 )O 3-δ ceramics stabilized in tetragonal/rhombohedral [P4mm + R3m] mixed phases, while variations in the quantity of the respective phases were observed. Because both structure and crystal chemistry play key roles in achieving enhanced performance in chemical sensing and catalytic converters, detailed understanding of the phase transformations and crystal structure of Ba(Fe 0.7 Ta 0.3 )O 3-δ ceramics, as derived in this work, will be useful to develop chemical sensors with optimum performance for high-temperature and corrosive environments.

36 MATERIALS SCIENCE↗

Irradiation of ultrasonic sensors and adhesive couplants for application in light water reactor primary loop piping and components

The Electric Power Research Institute (EPRI) Nuclear Sector and US Department of Energy Light Water Reactor Sustainability Program are committed to engaging in research and development endeavors to address materials aging issues specific to long term operation of light water power reactors. To this effect, EPRI launched an industry initiative to develop nondestructive evaluation systems for online monitoring of existing cracks in light water reactor primary coolant loop piping and components. One of the goals of this initiative is to develop a sensor system (or systems) that can determine nondestructively if cracks are growing or arrested and, in the case of the former, to characterize their growth rates. A missing component of this initiative is an experimental assessment of how sensors and adhesive couplants will perform in service when exposed to chronic energetic neutron radiation, particularly at the primary coolant loop hot and cold leg dissimilar metal welds, which join the primary loop piping to the reactor pressure vessel and reside in the vicinity of the reactor core. The objective of this experimental study was to determine how ultrasonic transducers and adhesive couplants perform when exposed to irradiation in a test reactor to simulate and accelerate in-service exposure. Further, to achieve this objective, the signal stability of piezoelectric transducers and performance of adhesive couplants as a function of accumulated fast neutron fluence were characterized by collecting ultrasonic data in-situ during irradiation. Of particular interest were the ultrasonic signal quality and time decay of the amplitude of acoustic reflections as a function of fast neutron fluence. The results of the study showed that, of the 8 transducer/substrate sample assemblies tested, only 3 generated usable ultrasonic signals through the conclusion of the irradiation campaign. It was found that high temperature epoxy tends to ultrasonically couple the sensors to the substrates better than three types of refractory ceramic cements studied, as is supported by post irradiation examination. The results obtained through this experimental study will be utilized in the achievement of the overall goal of development of a sensor system to perform online monitoring of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensor Recommendations for Long Term Monitoring of the F-Area Seepage Basins

In mid-2018, a new paradigm for long-term monitoring was developed after of decade of applied research projects funded by the Department of Energy’s office of Environmental Management Technology Development program. The program at SRNL was focused on transitioning complex environmental waste sites from active to passive remediations strategies. A key result of these studies was that the use of enhanced attenuation approaches at radiologically contaminated sites will result in the creation of secondary source areas in the subsurface that will require monitoring for decades. Alternative monitoring approaches are being developed and tested at the Savannah River Site’s F-Area Hazardous Waste Management Facility, the new paradigm provides innovative solutions that will significantly lower costs of monitoring through the coupling of data collection, machine learning and deterministic groundwater modeling. The foundation of this approach is a well-optimized network of sensors for measuring hydrogeochemical master variables that control, and therefore act as indicators of groundwater contaminant transport. By monitoring changes in the controlling master variables over time arising from geological and environmental shifts, predictive modelling can assist with identifying new strategies for ensuring regulatory requirements are met if trends toward conditions for potential remobilization of attenuated contaminants are detected. In this report, we evaluated commercially available single parameter sensor platforms (e.g., temperature/depth) and configurable multi-parameter sensor platforms (e.g., pH, oxidation-reduction potential, temperature, depth, dissolved oxygen, and conductivity). Each was scored using an optimization function based on how well the system supports the proposed long-term monitoring paradigm, in general, and the site-specific conditions at F-Area, in particular. Several viable sensor systems were identified. Of these, a combined platform including the In-Situ Aqua TROLL 500 multi-parameter sensor platform and the In-Situ temperature/depth sensor had the highest rating and was identified as the most suitable candidate for installation and monitoring of the master variables and potentiometric surface that control groundwater contaminant plumes emanating from the F-Area Seepage Basins. The discussion of recommended potential deployment locations builds upon recommendations made by Denham et al (2019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fiber-Based Distributed Hydrogen Measurement at High Temperatures

In this work, we discuss the implementation of evanescent field optical fiber sensors for distributed gas sensing of H2, focusing on results using a Ni / Gd-doped CeO2 nanocomposite sensing material for detection of low levels of H2 (0-4%) at 700 °C. This approach utilizes sensors prepared using a low-cost, wet chemical deposition process, in conjunction with a custom-built interrogator system leveraging optical time domain reflectometry (OTDR). Using a specially designed dual-gas flow reactor system, the sensor is tested by establishing a controlled equilibrium gradient of gas concentration. Initial results are shown using silica fiber, but provides a pathway for utilization with high temperature stable single crystal optical fiber for operation at higher temperatures and higher levels of H2 relevant for solid oxide fuel cell (SOFC) operating conditions.

Wuenschell, Jeffrey↗

Data and scripts associated with "Coupled primary production and respiration in a large river contrasts with smaller rivers and streams."

This data package is associated with the publication "Coupled primary production and respiration in a large river contrasts with smaller rivers and streams." in review at Limnology and Oceanography (Roley et al. 2023). This study focuses on understanding ecosystem metabolism for the Hanford Reach of the Columbia River in Washington state, a free-flowing stretch with a substantial discharge. Large rivers have been overlooked compared to small and medium rivers due to the challenges associated with measurements. Our study presents novel ways to address these challenges and highlights that metabolism patterns in large rivers differ from those observed in small-medium rivers and requires the application of knowledge and tools beyond those implemented for smaller rivers.This data package includes the data and R scripts for the analyses described in Roley et al. 2023. It includes dissolved oxygen and temperature data from a dissolved oxygen HOBO sensor, light data collected from the National Solar Radiation Database (https://nsrdb.nrel.gov/) and hydrologic variables estimated from the MASS-1 model (Niehus et al.; 2014). It also includes metabolism estimates (gross primary production, ecosystem respiration, and net ecosystem production) estimated via streamMetabolizer (Appling et al.; 2018). All analyses in the paper can be replicated with these data and scripts.The data package is comprised of one main data folder. The folder includes (1) file-level metadata (flmd); (2) a data dictionary (dd) for each data file; (3) data files; and (4) R scripts for metabolism estimates and data analysis. All files are .R, .csv, or .pdf.

54 ENVIRONMENTAL SCIENCES↗

Behavior of the Fused Quartz Suspended Core Acoustic Waveguide Sensor in Gamma Radiation

Previously, a fused-quartz acoustic waveguide named the suspended core waveguide with tight-field confinement in a small diameter was developed and its sensing potential in harsh environment was demonstrated with the fabricated periodic acoustic fiber Bragg grating. In this paper, the acoustic sensor was exposed to around 70 Gy/h gamma radiation at room temperature for 3550 h at Oak Ridge National Laboratory. For comparisons, a thermocouple and two optical fiber Bragg gratings were tested under the same conditions. The central frequency reading of the acoustic sensor was found to encounter a relatively fast decrease of 0.5 kHz in the first 800 hours. The reading then became stable, centering at 478.5 kHz with a fluctuation of ±0.2 kHz, and responded to small environmental temperature variations less than 1.2 °C. The major effect to the fluctuation was concluded to be radiation-induced material compaction and expansion. For optical fiber Bragg gratings, the same one-directional fast change of readings in the first 500 hours were observed as well. Although the optical gratings were able to track temperature changes, they also showed continuous drifts. The survivability and consistency of the acoustic sensor under long-term gamma radiation could lead to new sensing methods in nuclear applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Optimal sensor network design for multi-scale, time-varying differential algebraic equation systems: Application to an entrained-flow gasifier refractory brick

An algorithm for optimal sensor network design for multi-scale, time-varying differential algebraic equation systems with non-separable dynamics is presented. As the process is time-varying, an integral normalized posterior error covariance of a multi-scale filter is minimized to obtain the optimal sensor locations. For reducing the computational cost, an adaptive sampling rate approach is considered for the slowly-varying variables. The algorithm is applied to a smart refractory brick with embedded sensors as part of an entrained-flow gasifier. Thermistors and interdigital capacitors are considered as candidate measurement technologies for estimating temperature and slag penetration profile along the gasifier wall. Finally, when the optimal set of sensors obtained from the algorithm is used for estimating temperature and slag penetration profiles in a multi-scale Kalman filter framework, satisfactory estimates are obtained despite high measurement noise and model mismatch.

42 ENGINEERING↗

Thermally-Induced Breakouts: Insights from True-Triaxial Tests with Acoustic Emission Monitoring

Borehole breakouts are used to constrain the magnitude of maximum horizontal stress. However, when the borehole wall strength is higher than the in situ tangential stress, borehole wall failure does not develop. Additional compressive stress can be induced by heating borehole walls. To validate this concept experimentally, we conducted room-temperature and elevated temperature true-triaxial tests on Berea sandstone and Niagaran dolomite samples. We used acoustic emission sensors to capture the onset of breakout development, and we measured the temperature close to borehole wall to assess the magnitude of induced thermal hoop stress. The test results show that within a specific rock type, the breakouts develop in similar manner in room-temperature and elevated-temperature tests. Therefore, the maximum horizontal stress can be constrained from the following dataset: critical tangential stress at which breakout develops, minimum horizontal stress, elastic and thermal properties, and temperature change at the borehole wall.

Trzeciak, Maciej↗

Sub-second and ppm-level optical sensing of hydrogen using templated control of nano-hydride geometry and composition

Abstract The use of hydrogen as a clean and renewable alternative to fossil fuels requires a suite of flammability mitigating technologies, particularly robust sensors for hydrogen leak detection and concentration monitoring. To this end, we have developed a class of lightweight optical hydrogen sensors based on a metasurface of Pd nano-patchy particle arrays, which fulfills the increasing requirements of a safe hydrogen fuel sensing system with no risk of sparking. The structure of the optical sensor is readily nano-engineered to yield extraordinarily rapid response to hydrogen gas (<3 s at 1 mbar H 2 ) with a high degree of accuracy (<5%). By incorporating 20% Ag, Au or Co, the sensing performances of the Pd-alloy sensor are significantly enhanced, especially for the Pd 80 Co 20 sensor whose optical response time at 1 mbar of H 2 is just ~0.85 s, while preserving the excellent accuracy (<2.5%), limit of detection (2.5 ppm), and robustness against aging, temperature, and interfering gases. The superior performance of our sensor places it among the fastest and most sensitive optical hydrogen sensors.

36 MATERIALS SCIENCE↗

Ultrasonic Measurements of Temperature Distribution in Extreme Environments: Results of Power Plant Testing

The most hardened insertion sensors do not perform reliably in extreme environmental conditions. We address this problem by developing an ultrasonic thermometry system for the measurements of segmental temperature distributions (MSTD) in solid materials and, specifically, across containments of energy conversion processes. The MSTD approach uses an echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features. In pulse-echo mode, these features produce a train of echoes in response to an external pulse of ultrasonic excitation created and acquired by a transducer located outside the extreme environment. The delays between the echoes encode the information on the temperature distribution in the corresponding segments of the ultrasonic propagation path, which we use to reconstruct an unknown temperature profile. This note describes the preliminary results and initial experience in applying the developed MSTD ultrasonic thermometry system to the measurements of temperatures in a utility-scale 500MW coal-fired boiler.

John, Mason↗

A Predictive Model for Internal Magazine Temperatures

This report describes data and methodology used to predict temperatures inside magazines used to store explosive devices, based on outside temperatures from a local weather station and data logged by sensors inside a single magazine over a limited period. It follows on earlier work and predictive models. In conjunction with aging models, predicted temperatures can be used to estimate degradation in the performance of explosives over long periods of storage.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Chemiresistor sensor based on ion-imprinted polymer (IIP)-functionalized rGO for Cd(II) ions in water

This study reports the design and development of a novel chemiresistor (CR) sensor using ion imprinted polymer (IIP)-functionalized reduced graphene oxide (rGO) [IIP/rGO-CR] for cadmium ions (Cd(II)) determination in water. The sensor consisted of a CR transducer made of rGO channel bridging source and drain electrodes prepared by self-assembly and thermal reduction of graphene oxide (GO) on Au interdigitated electrodes chip fabricated on Si/SiO 2 substrate. The IIP was then grafted on rGO using surface-initiated reversible addition-fragmentation chain transfer (RAFT) polymerization with polyethylenimine (PEI) and methylacrylic acid (MAA) as dual functional monomers and Cd(II) ions as template through UV light-initiated copolymerization. The IIP functionalized on rGO acted as an effective recognition element that modulated the resistance of rGO-CR upon binding of Cd(II), enabling Cd(II) detection at ppb level in aqueous solutions. The prepared IIP/rGO-CR sensor worked effectively in the linear range of 2~200ppb and achieved a limit of detection (LOD) of 0.83 ppb, which is lower than the World Health Organization guidelines of 3ppb for drinking water quality. The developed sensor of IIP/rGO-CR showed a high selectivity against a variety of trace and heavy metal ions found in water and good stability for up to 60 days when stored at room temperature for Cd(II) determination in water. Further, the sensor was successfully applied to analyzing Cd(II) spiked in tap, lake and river waters with a 94.5%–113.5% recovery, demonstrating a high degree of accuracy even in complex water samples. Finally, our results illustrated that the CR sensor of IIP functionalized rGO provides a potential platform for sensitive, robust and low-cost environmental analysis of Cd(II) in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

JHU Baltimore iButton data

Temperature and Relative Humidity data from a low cost sensor ("iButton") network deployed in Baltimore in summer 2015, 2016, 2017, 2021, and 2022. Initial deployment described in Scott, A., Zaitchik, B., Waugh, D., O'Meara, K. 2017. Intra-Urban temperature variability in Baltimore. Journal of Applied Meteorology and Climatology, 56(1): 159-171. doi: 10.1175/JAMC-D-16-0232.1

applied meteorology↗