Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Spectral studies of soft x-ray radiation of laser-produced plasma of various target materials in a wide spectral range

Here, the work is devoted to experimental study of soft X-ray radiation spectra of laser produced plasma in a wide spectral range 5–100 Å at the “Kamerton” facility (GPI) with pulse duration 70 ps, pulse energy 1–5 J, wavelength 0.53 microns at which the laser intensity (power flux density) of 7×10 14 – 3.5×10 15 W/cm 2 was achieved. A spectrograph was used, which had transmission diffraction gratings with a ratio of the elementary gap to the period of the structure of 0.25 and 0.41. Detection was performed on both UV-4 X-ray photo film and Fuji TR fluorescent imaging plate. Solid samples from Al, Si, Ti, Cu, Ta and W were used as targets. The ionization states of the plasma corresponding to various electron temperatures were calculated, which made it possible to estimate the electron temperature by comparison these calculation results with the experimentally obtained spectra. The estimated electron temperature, which depends on the laser pulse energy and the target material, varied within the range of 100–450 eV. To verify the correctness of the temperature estimations obtained by such comparison a numerical simulation of plasma radiation was carried out by the use of PrismSPECT computer program. It was found that the results of this simulation are in a good agreement with estimations on the base of experimentally obtained spectra. The analysis of these spectra showed that tantalum, tungsten or titanium targets are the best candidates among the tested ones for the use of laser produced plasma as a radiation source in the "water window" spectral range (23–44 Å) for applications in biology and medicine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bioverse: A Comprehensive Assessment of the Capabilities of Extremely Large Telescopes to Probe Earth-like O 2 Levels in Nearby Transiting Habitable-zone Exoplanets

Molecular oxygen is a strong indicator of life on Earth and may indicate biological processes on exoplanets too. Recent studies proposed that Earth-like O 2 levels might be detectable on nearby exoplanets using high-resolution spectrographs on future extremely large telescopes (ELTs). However, these studies did not consider constraints like relative velocities, planet occurrence rates, and target observability. We expanded on past studies by creating a homogeneous catalog of 286,391 main-sequence stars within 120 pc using Gaia DR3 and used the Bioverse framework to simulate the likelihood of finding nearby transiting Earth analogs. We also simulated a survey of M dwarfs within 20 pc accounting for η ⊕ estimates, transit probabilities, relative velocities, and target observability to determine how long ELTs and theoretical 50–100 m ground-based telescopes need to observe to probe for Earth-like O 2 levels with an R = 100,000 spectrograph. This would only be possible within 50 yr for up to ~21% of nearby M-dwarf systems if a suitable transiting habitable-zone Earth analog was discovered, assuming signals from every observable partial transit from each ELT can be combined. If so, Earth-like O 2 levels could be detectable on TRAPPIST-1 d–g within 16–55 yr, respectively, and about half that time with an R = 500,000 spectrograph. These results have important implications for whether ELTs can survey nearby habitable-zone Earth analogs for O 2 via transmission spectroscopy. Our work provides the most comprehensive assessment to date of the ground-based capabilities to search for life beyond the solar system.

79 ASTRONOMY AND ASTROPHYSICS↗

A critical review of cyber-physical security for building automation systems

Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.

97 MATHEMATICS AND COMPUTING↗

VERITAS and Multiwavelength Observations of the Blazar B3 2247+381 in Response to an IceCube Neutrino Alert

While the sources of the diffuse astrophysical neutrino flux detected by the IceCube Neutrino Observatory are still largely unknown, one of the promising methods to improve our understanding of them is investigating the potential temporal and spatial correlations between neutrino alerts and the electromagnetic radiation from blazars. We report on the multiwavelength target-of-opportunity observations of the blazar B3 2247+381, taken in response to an IceCube multiplet alert for a cluster of muon neutrino events compatible with the source location between 2022 May 20 and 2022 November 10. B3 2247+381 was not detected with VERITAS during this time period. The source was found to be in a low-flux state in the optical, ultraviolet, and gamma-ray bands for the time interval corresponding to the neutrino event, but was detected in the hard X-ray band with NuSTAR during this period. We find the multiwavelength spectral energy distribution is described well using a simple one-zone leptonic synchrotron self-Compton radiation model. Moreover, assuming the neutrinos originate from hadronic processes within the jet, the neutrino flux would be accompanied by a photon flux from the cascade emission, and the integrated photon flux required in such a case would significantly exceed the total multiwavelength fluxes and the VERITAS upper limits presented here. The lack of flaring activity observed with VERITAS, combined with the low multiwavelength flux levels, as well as the significance of the neutrino excess being at a 3σ level (uncorrected for trials), makes B3 2247+381 an unlikely source of the IceCube multiplet. We conclude that the neutrino excess is likely a background fluctuation.

79 ASTRONOMY AND ASTROPHYSICS↗

The MUSE Target Chamber Post Veto

The Muon Scattering Experiment (MUSE) was developed to address the proton radius puzzle through simultaneous electron–proton and muon-proton scattering using the Paul Scherrer Institute’s πM1 secondary beamline. MUSE uses a large-solid-angle, non-magnetic spectrometer to detect beam particles scattering from a liquid hydrogen cell contained within a vacuum chamber. Due to the large scattering windows, the structural integrity of the chamber is supported by posts located at small scattering angles. While out of the acceptance, particles in the tails of the beam distribution can strike these posts, causing a significant trigger background. We describe the design and performance of the Target Chamber Post Veto (TCPV) detector installed inside the vacuum chamber to remove these background events at the trigger level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Management of Risks Associated with Application of Novel Materials in Novel Operating Environments in Novel Reactor Designs

There is currently no widely agreed, detailed general method for licensing a novel plant incorporating novel materials (or materials being deployed in novel environments); in many such situations, there are no directly applicable engineering code cases for decision-makers (including regulators) to rely on. This paper discusses a framework for solving this problem that is based on the Reliability and Integrity Management (RIM) approach delineated in ASME BPVC Section XI Division 2. NRC Regulatory Guide 1.246, Rev. 0, endorses, with conditions, the subject portion of the ASME Code. The proposed framework is meant to support development of a licensing case by addressing certain technical challenges. The framework discussed here is compatible with the Licensing Modernization Project, but applying it in a specific case will call for advances in the state of practice, if not the state of the art. The RIM approach calls for applicants to (a) allocate reliability targets to plant structures, systems, and components (SSCs), (b) show that they are able to relate the currently observed physical condition of each SSC in the program to its failure probability well enough to determine whether the target reliability allocations are being satisfied, allowing for uncertainty related to the novelty of the materials/designs/operating environments, and (c) be able to demonstrate that the proposed program of surveillances will reliably detect unacceptable degradation of an SSC before SSC failure occurs. These challenges are discussed in the paper, and a potentially applicable modeling approach based on cumulative damage rather than failure rates is briefly illustrated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and evaluation of a Novel RT‐PCR system for reliable and rapid SARS‐CoV ‐2 screening of blood donations

Abstract Background The ongoing outbreak of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) has caused great global concerns. In contrast to SARS, some SARS‐CoV‐2–infected people can be asymptomatic or have only mild nonspecific symptoms. Furthermore, there is evidence that SARS‐CoV‐2 may be infectious during an asymptomatic incubation period. With the discovery that SARS‐CoV‐2 can be detected in plasma or serum, blood safety is worthy of consideration. Study Design and Methods We developed a nucleic acid test (NAT) screening system for SARS‐CoV‐2 targeting nucleocapsid protein (N) and open reading frame 1ab (ORF 1ab) gene that could screen 5076 samples every 24 hours. The 2019 novel coronavirus RNA standard was used to evaluate linearity of standard curves. Diagnostic sensitivity and reproducibility were evaluated using artificial SARS‐CoV‐2. Specificity was evaluated with 61 other respiratory pathogens. Diagnostic performance was evaluated by testing two sputum and nine oropharyngeal swab specimens. The reverse transcription polymerase chain reaction (RT‐PCR) assay was used to screen SARS‐CoV‐2 RNA in blood donor specimens collected during the outbreak of SARS‐CoV‐2 in Chengdu. Results Limits of detection of the SARS‐CoV‐2 RT‐PCR assay for N and ORF 1ab gene were 12.5 and 27.58 copies/mL, respectively. Intra‐assay and interassay for the SARS‐CoV‐2 RT‐PCR assay based on cycle threshold were acceptably low. No cross‐reactivity was observed with other respiratory virus and bacterial isolates. The overall agreement value between the SARS‐CoV‐2 RT‐PCR assay and clinical diagnostic results was 100%. A total of 16 287 blood specimens collected from blood donors during SARS‐CoV‐2 surveillance were tested negative. Conclusions A high‐throughput NAT screening system was developed for SARS‐CoV‐2 screening of blood donations during the outbreak of SARS‐CoV‐2.

Li, Meng↗

Detecting thermal crack growth on a large additive manufactured structure using acoustic emission

Large format additive manufacturing (LFAM) proved to have a great potential to become an adjacent technology to traditional manufacturing methods. One of the sectors LFAM is targeting is rapid tool/mold development for composites. This includes large mold structures used for high-temperature molding techniques (in-oven or autoclave). Although, these large printed structures (reaching hundreds of pounds) develop thermal-residual stress during cool-down and can eventually crack, turning the structure into waste. Acoustic emission (AE), a passive non-intrusive global nondestructive evaluation (NDE) technique, was used to monitor crack growth and can provide the right tools that can be used for feedback loop for corrective action. This research performs thermal testing on a large AM mold with preexisting cracks, in an attempt to monitor crack growth using AE. AE was able to detect, identify and locate the crack source by means of acoustic features, waveform characteristics, spectrum analysis, and difference in arrival times.

Spencer, Ryan↗

A Deep Learning Approach for Detection and Localization of Leaf Anomalies

The detection and localization of possible diseases in crops are usually automated by resorting to supervised deep learning approaches. In this work, we tackle these goals with unsupervised models, by applying three different types of autoencoders to a specific open-source dataset of healthy and unhealthy pepper and cherry leaf images. CAE, CVAE and VQ-VAE autoencoders are deployed to screen unlabeled images of such a dataset, and compared in terms of image reconstruction, anomaly removal, detection and localization. The vector-quantized variational architecture turns out to be the best performing one with respect to all these targets.

Calabro', Davide↗

Could Irradiation Introduce Oxidized Oxygen Signals in Resonant Inelastic X-ray Scattering of Battery Electrodes?

The characterization of oxidized oxygen states through high-efficiency mapping of resonant inelastic X-ray scattering (mRIXS) has become a crucial approach for studying the oxygen redox activities in high-energy battery cathodes. However, this approach has been recently challenged due to the concern of irradiation damage. In this work, we revisited a typical Li-rich electrode, Li 1.144 Ni 0.136 Mn 0.544 Co 0.136 O 2 , in both lithiated and delithiated states and evaluated the X-ray irradiation effect in the lengthy mRIXS experiments. Our results show that irradiation cannot introduce any oxidized oxygen feature, and the features of oxidized oxygen are weakened with a high X-ray dose. The results confirm again that mRIXS detects the intrinsic oxidized oxygen state in battery electrodes. However, the distinct irradiation effects in different systems imply that irradiation could selectively target the least stable elemental or chemical states, which should be analyzed with caution in the study of active chemical states.

25 ENERGY STORAGE↗

Cloud micro- and macrophysical properties from ground-based remote sensing during the MOSAiC drift experiment

In the framework of the Multidisciplinary drifting Observatory for the Study of Arctic Climate Polarstern expedition, the Leibniz Institute for Tropospheric Research, Leipzig, Germany, operated the shipborne OCEANET-Atmosphere facility for cloud and aerosol observations throughout the whole year. OCEANET-Atmosphere comprises, amongst others, a multiwavelength Raman lidar, a microwave radiometer, and an optical disdrometer. A cloud radar was operated aboard Polarstern by the US Atmospheric Radiation Measurement program. These measurements were processed by applying the so-called Cloudnet methodology to derive cloud properties. To gain a comprehensive view of the clouds, lidar and cloud radar capabilities for low- and high-altitude observations were combined. Cloudnet offers a variety of products with a spatiotemporal resolution of 30 s and 30 m, such as the target classification, and liquid and ice microphysical properties. Additionally, a lidar-based low-level stratus retrieval was applied for cloud detection below the lowest range gate of the cloud radar. Based on the presented dataset, e.g., studies on cloud formation processes and their radiative impact, and model evaluation studies can be conducted.

54 ENVIRONMENTAL SCIENCES↗

Reporter-Spin-Assisted T 1 Relaxometry

A single-spin quantum sensor can quantitatively detect and image fluctuating electromagnetic fields via their effect on the sensor spin’s relaxation time, thus revealing important information about the target solid-state or molecular structures. However, the sensitivity and spatial resolution of spin relaxometry are often limited by the distance between the sensor and target. Here, we propose an alternative approach that leverages an auxiliary reporter spin in conjunction with a single-spin sensor, a diamond nitrogen-vacancy (N-V) center. We show that this approach can realize a 100-fold measurement sensitivity improvement for realistic working conditions and we experimentally verify the proposed method using a single shallow N-V center. Our work opens up a broad path of inquiry into a range of possible spin systems that can serve as relaxation sensors without the need for optical initialization and readout capabilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In search of autophagy biomarkers in breast cancer: Receptor status and drug agnostic transcriptional changes during autophagy flux in cell lines

Autophagy drives drug resistance and drug-induced cancer cell cytotoxicity. Targeting the autophagy process could greatly improve chemotherapy outcomes. The discovery of specific inhibitors or activators has been hindered by challenges with reliably measuring autophagy levels in a clinical setting. We investigated drug-induced autophagy in breast cancer cell lines with differing ER/PR/Her2 receptor status by exposing them to known but divergent autophagy inducers each with a unique molecular target, tamoxifen, trastuzumab, bortezomib or rapamycin. Differential gene expression analysis from total RNA extracted during the earliest sign of autophagy flux showed both cell- and drug-specific changes. We analyzed the list of differentially expressed genes to find a common, cell- and drug-agnostic autophagy signature. Twelve mRNAs were significantly modulated by all the drugs and 11 were orthogonally verified with Q-RT-PCR (Klhl24, Hbp1, Crebrf, Ypel2, Fbxo32, Gdf15, Cdc25a, Ddit4, Psat1, Cd22, Ypel3). The drug agnostic mRNA signature was similarly induced by a mitochondrially targeted agent, MitoQ. In-silico analysis on the KM-plotter cancer database showed that the levels of these mRNAs are detectable in human samples and associated with breast cancer prognosis outcomes of Relapse-Free Survival in all patients (RSF), Overall Survival in all patients (OS), and Relapse-Free Survival in ER + Patients (RSF ER + ). High levels of Klhl24, Hbp1, Crebrf, Ypel2, CD22 and Ypel3 were correlated with better outcomes, whereas lower levels of Gdf15, Cdc25a, Ddit4 and Psat1 were associated with better prognosis in breast cancer patients. This gene signature uncovers candidate autophagy biomarkers that could be tested during preclinical and clinical studies to monitor the autophagy process.

60 APPLIED LIFE SCIENCES↗

5ω Optical Thomson Scattering Report

The 5ω Optical Thomson Scattering system on the National Ignition Facility (NIF) is a diagnostic designed to measure temporally and spatially resolved plasma conditions in Inertial Confinement Fusion (ICF) Hohlraums. The system was proposed in 2014 and a phased approach to implementation was developed. In phase one the collection system was designed, built, and fielded on the NIF to be used for 3ω Thomson scattering measurements and background measurements near 211 nm (5ω. The initial commissioning experiment for the collection system was completed in Oct. 2016. Commissioning of the collection system continued through 2017 and the system is now fielded for a range of user experiments and regularly produces publication quality data. A dedicated 5ω probe laser was designed and built to allow Thomson scattering measurements in the presence of 2 MJ of 3ω drive energy. Due to scattered light (spectral reflections, laser-plasma instabilities, and unconverted drive energy) from the 3w drive lasers typical wavelengths (2ω and 4ω) fielded at other laser facilities like the Nova Laser Facility and the Omega Laser Facility were unable to meeting the signal to background requirements in design studies. A 10 Joule 5ω probe was proposed as a solution that met requirements. This 10 Joule laser was more energetic than previously fielded 5w lasers by 2-3 orders of magnitude. As part of a risk reduction plan, phase two of the project was to develop a 1 Joule, 5ω laser to demonstrate conversion efficiency >20% from 1ω to 5ω and make initial Thomson scattering measurements in the first few nanoseconds of an ICF laser pulse. Initial tests of the 5w conversion were completed at the Laboratory for Laser Energetics (LLE) and produced record 5ω energies. Based on these results from LLE, a 1 Joule, 5w laser system was designed for the NIF in 2018 and commissioning began in 2019. Commissioning of the 5ω laser system continued through 2023 and was eventually paused in Q1 of FY24 due to completing resource constraints. Commissioning of the 5w laser system proved incredibly challenging. Multiple issues were identified during commissioning and resolved, but issues remain. Currently there is not a clear understanding of why 5ω scattered has not been detected on the OTS collection system. Based on offline measurements, calculations, and preshot measurements the system appears to meet all requirements. Potential target physics issues have been investigated and do not appear to be an issue. The current hypothesis is that there is an error in one or more aspects of the offline testing not translating to expected performance when the system is fielded on the NIF. Additional full system testing in-situ utilizing the complete OTS system and NIF target chamber center time is needed to further test potential failure modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanopore Readable Activity Probes for Ribosomal Inactivating Protein (RIP) Toxins

Ribosome inactivating proteins (RIPs) such as ricin and abrin depurinate an adenine base in the sarcin/ricin loop in the large ribosomal subunit, leading to inhibtion of protein synthesis and cell death. Here, we demonstrate that RIP toxin activity can be detected via nanopore-based DNA sequencing using synthetic oligonucleotide substrates. This is achieved by monitoring the mismatch proportion at the canonical target sequences incorporated into the synthetic substrate and determining the sequence length distribution throughout the entire substrate sequence. The mismatch proportion increases and sequence length distribution decreases with increasing toxin concentration for both ricin and abrin in buffer as well as in more complex backgrounds such as saliva and nasal secretions.

Turner, Matthew W [Pacific Northwest National Labo↗

A Time-Gated, Time-Correlated Single-Photon-Counting Lidar to Observe Atmospheric Clouds at Submeter Resolution

Most lidars used for cloud observations have the range resolution of about 10 m, so they are incapable of resolving submeter-scale processes that are crucial to cloud evolution. This article describes a prototype of a ground-based, vertically pointing, time-gated, time-correlated single-photon-counting lidar (referred to as the T2 lidar) developed to explore atmospheric clouds at range resolution two orders of magnitude finer than traditional atmospheric lidars. The T2 lidar emits green-light pulses (532 nm) at a repetition rate of 20.6 kHz and a pulse width of ∼650 ps, which enables the observation of aerosol and cloud layers at heights from a few hundred meters to 7.28 km above the ground level at range resolution down to 10 cm. In addition, a digital delay pulse generator controls the detector to only receive photons for a short period after each laser pulse. This time-gated technique blocks photons arriving from regions outside the target zone, thus significantly reducing the noise level and allowing observation even inside clouds. Initial observations show that the T2 lidar can detect sharp cloud boundaries and fine structures near the cloud base. Such refined measurements of cloud structure could lead to an improved understanding of microphysical processes such as droplet activation, entrainment and mixing, and precipitation.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

J/ψ Near-Threshold Photoproduction off the Proton and Neutron with CLAS12

In recent years, J/? photoproduction in the near-threshold region has seen a renewed theoretical interest due to the wealth of information it has to offer. Near-threshold J/? photopro-duction proceeds through the exchange of gluons in the t-channel and is expected to provide unique insight about the nucleon gluonic gravitational form factors (GFFs). Previous studies at the Thomas Jefferson National Accelerator Facility (JLab) in Virginia, USA, have already measured the total and differential cross section of J/? near-threshold photoproduction on the free proton. This thesis presents the first measurements of J/? near-threshold photoproduction on the bound proton and bound neutron in a deuteron target. The CEBAF Large Acceptance Spectrometer at 12 GeV (CLAS12) based at JLab?s Hall B uses a 11 GeV electron beam impinging on a fixed liquid deuteron target. J/? is then produced via the exchange of a quasi-real photon and decays to a lepton pair which is detected along-side the recoil nucleon by CLAS12. Analysis procedures and in particular machine learning based techniques were developed in order to correctly identify final state particles and select J/? photoproduction events. The total and differential cross section of J/? near-threshold photoproduction on the bound proton and bound neutron were then measured from the detected J/? photoproduction events. The measurements of the cross sections on the bound proton and bound neutron agree well within their statistical uncertainty. This is consistent with the assumed two-gluon exchange production mechanism which is isospin invariant. Overall a first measurement of the J/? near-threshold photoproduction cross sections on the bound proton and bound neutron was achieved. A better understanding of the mechanical properties of the nucleon, such as pressure and mass distributions, can be obtained by relating J/? production to the nucleon GFFs. This opens the way for exciting new insights into the internal structure of the nucleon, and in particular of the nucleon?s gluonic content. An upcoming overhaul of the CLAS12 reconstruction will increase the reconstruction efficiency and the statis- tical precision of the preliminary measurements described in this thesis, with an expected gain in statistics of at least 50%. Future upgrades at JLab will allow to test some of the theoretical assumptions made in relating J/? near-threshold photoproduction to the nucleon GFFs

Tyson, Richard↗