Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stream operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Electrolyte chemistry and improved stack performance in high brine concentration electrodialysis

Methods for improving ion flux and energy efficiency in a membrane stack of an electrodialysis unit wherein the membrane stack is disposed between an anode and a cathode each in an electrolyte of a selected concentration. Methods include increasing the concentration of the electrolyte, adding a strong base to the electrolyte and adding buffering anions to the electrolyte. Methods for cleaning the electrodes of such a unit involving involve applying a pulsed polarity reversal to the electrodes. Also provided are methods for improving unit operation by increasing the basicity of the electrolyte to the anode and increasing the acidity of the electrolyte to the cathode or alternatively or in addition, by applying heat to increase the operating temperature of at least one of the electrolyte and the treated water stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flow assisted anti-fouling geometries for compact heat exchangers

A header for a heat exchanger and method for cleaning a heat exchanger in a loop without disconnecting loop components is provided. The header is in flow communication with the heat exchanger for distributing fluid through a plurality of adjacent channels. The header is connected between a main heat exchanger inlet nozzle and a channel flow distributor. A filter element is disposed within the header between the nozzle and channel flow distributor. Under normal operation, the filter element removes particulates and fouling material from the main flow stream before it enters the heat exchanger channels. During the cleaning process, fluid is injected on or through the filter element to remove particulates and fouling material through at least one outlet port. The header arrangement allows the filter element to be ‘cleaned in place’ without draining the system and disconnecting the heat exchanger or other components from the flow loop.

Carlson, Matthew David↗

Peroxide Decomposer Module Catalyst Testing to Support Preparations for Increased Demand - 19052

The Hanford Site Effluent Treatment Facility's (ETF) mission is to receive, treat, and dispose of liquid effluents from on-site programs and projects. Its roles in the management and mitigation of tank waste volume is integral to the overall Hanford tank farms mission, as tank space is limited. ETF's role will become even more essential as the Direct-Feed Low Activity Waste process comes online at the Waste Treatment and Immobilization Plant (WTP). In order to accommodate the additional liquid effluent streams, the ETF will undergo a number of facility and equipment upgrades. Included in this is the reinstatement of the Peroxide Decomposer Module (PDM) into the ETF's main treatment train. The PDM is used to remove any residual hydrogen peroxide not fully consumed in the preceding ultraviolet/oxidation (UV/OX) treatment stage for organic destruction. Future waste stream estimates have been shown to contain organic content requiring excess hydrogen peroxide addition. Restoration of the PDM will ensure the ETF can accommodate the higher anticipated levels of organic content in these new influent streams. Due to low organic content levels in the current influents and some operability issues with the PDM, it has not been in operation since 1998. One aspect of the repair and upgrade of the PDM is the usability of manganese dioxide on alumina catalyst, Sud-Chemie T-2525, which was purchased in 2008 but has remained in storage since. The manufacturer of the catalyst states there is no known shelf life for the product and no current data to indicate the catalyst's performance after long-term storage. To determine the usability of the stored catalyst, a laboratory test was developed. The testing of this stored catalyst was based on testing methods and information collected from initial catalyst product testing performed in 2008. This test involved spiking the catalyst with 200 ppm hydrogen peroxide and then testing the resulting solution to determine the extent of peroxide destruction. Initial testing results of the Sud-Chemie T-2525 catalyst indicated reduced performance, so additional catalyst materials were selected for inclusion in the testing. These materials included Carulite{sup R} 200 catalyst, LayneOx{sup R}, natural manganese ore - pyrolusite (Pro-Ox{sup R}), and EnviCat{sup R} 2531 SPH 4-6. With the expansion of the test scope, fines generation testing was added to provide additional data for product selection, as excessive fines cause plugging in the PDM. The resulting test data are compared to the 2008 catalyst product testing data in order to evaluate performance of each product to determine whether the Sud-Chemie T-2525 is still viable and to determine the best candidate for its replacement. This testing provides essential information to the engineering and operations organizations managing the facility and equipment upgrades for the ETF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Leveraging Hydropower Multi-Sensor Data for Inference and Age-Informed Modeling

Increased demand of operational flexibility such as faster ramp up/down in generation, and more frequent start/stops are putting hydropower plants and their associated components in unprecedented stress. Consequently, these plants are at the high risk of extended and more frequent outage to accommodate unscheduled, and unexpected maintenance. Therefore, hydropower plants are in critical need of data driven and age-informed analysis for their regular and unscheduled operation. Yet not all hydropower plants are exhaustively equipped with sensors and/or measurement streams for their respective components – demanding solutions on how to detect, identify, and locate the cause of any event from the unobservable. Idaho National Laboratory (INL) analyzed the anonymized measurements and event records from the Hydropower Research Institute (HRI) to address this issue, as part of the Water Power Technologies Office (WPTO) funded one year multi-lab project. First, we investigated how time series of multiple sensor measurements can be leveraged to identify an event “root cause” as well as to develop an inference (i.e., estimate the unobservable) problem. INL also investigated how individual hydropower components’ reaction or response times vary across the pre-event, during event, and post-event conditions – enabling the hydropower dynamic models to be age-informed. Finally, the impact of clustering multi-sensor time series on short-term vibration prediction is analyzed. INL will present key findings from these analyses and recommend next steps for stakeholder adoption.

13 HYDRO ENERGY↗

Acoustic levitator for containerless measurements on low temperature liquids

A single-axis acoustic levitator was constructed and used to levitate liquid and solid drops at temperatures from -40 to +40 C. The levitator consisted of: (i) two acoustic transducers mounted on a rigid vertical support that was bolted to an optical breadboard, (ii) a acoustic power supply that controlled acoustic intensity, relative phase of the drive to the transducers, and could modulate the acoustic forces at frequencies up to 1kHz, (iii) a video camera, and (iv) a system for providing a stream of controlled temperature gas flow over the sample. The acoustic transducers were operated at their resonant frequency of ~ 22 kHz and could produce sound pressure levels up to 160 dB. The force applied by the acoustic field could be modulated using a frequency generator to excite oscillations in the sample. Sample temperature was controlled using a modified Cryostream Plus and measured using thermocouples and an infrared thermal imager. The levitator was installed at x-ray beamline 11 ID-C at the Advanced Photon Source and used to investigate the structure of supercooled liquids.

Acoustic levitation↗

A decision support tool for e-waste recycling operations using the hen-and-chicks bio-inspired optimization metaheuristic

E-waste from end-of-life electrical and electronic devices is one of the fastest growing waste streams from households and businesses. E-waste recycling yields environmental sustainability and economic benefits. Due to continuous changes in e-waste types and compositions, recycling businesses face challenges to optimize their operational configuration to achieve better economic and environmental performance. To help e-waste recyclers mitigate this problem, we have developed a modular decision support tool called the Comprehensive Manufacturing Assessment Tool (CMAT) that can simulate both e-waste recycling operations and economics. This tool can give valuable insights regarding the profitability of the entire operation and different e-waste types. In addition, a new bio-inspired metaheuristic optimization algorithm, hen-and-chicks optimization (HACO), was developed to assign manpower to different workstations to maximize operational efficiencies. According to the results of our case study, laptops, desktops, and computer peripherals are the three electronic waste products that produce the most profit. Our examination of the sensitivity of material prices shows that the price of steel has the most significant influence on total profit, because it is the most widely used material in the majority of electronic devices. We have released the decision support tool as open-source software under a general public license. It could be customized for other recycling industries beyond e-waste to achieve business sustainability by making their operations more efficient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Three-dimensional, Gas Phase Fuel Cell with a Laccase Biocathode

A fuel cell using an enzymatic biocathode operating in a gas phase mode is reported. The electrode was prepared using a three-dimensional conductive electrode matrix. An enzyme solution containing laccase and a mediator was distributed into a hydrophilic matrix of carbon felt fibers creating a porous gas-flowing electrode. A Pt-based gas diffusion electrode served as the anode. A maximum power density of 9.4 W/m2 (2.9 kW/m3) was obtained with 15 U of enzyme/cm2, with hydrogen as the fuel. Power density was found to be a function of the enzyme loading, air flow rate, volume of the liquid phase and the humidity of the air stream. The ability to use methanol and ethanol as fuel in the form of vapors in an inert gas stream was also shown. The introduction of three-dimensionality into the electrode architecture and operation of the fuel cell in a gas phase mode to supply the fuel and the oxidant demonstrates an avenue for improving the power density of EFCs.

08 HYDROGEN↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

Evaluation of Hydrogen Production Feasibility for a Light Water Reactor in the Midwest

Increased electricity production from renewable energy resources coupled with low natural gas prices has caused existing light-water reactor (LWRs) to experience ever diminishing returns from the electricity market. Via partnership among Idaho National Laboratory (INL), The National Renewable Energy Laboratory (NREL), Argonne National Laboratory (ANL), Exelon, and Fuel Cell Energy a techno-economic analysis on the viability of retrofitting existing pressurized water reactors (PWRs) to produce hydrogen (H2) via high temperature steam electrolysis (HTSE) has been conducted. Such integration would allow nuclear facilities to expand into additional markets that may be more profitable in the long-term. To accommodate such an integration, a detailed analysis of HTSE process operation, requirements, and flexibility was conducted. Technical analysis includes proposed nuclear system control scheme modifications to allow dynamic operation of the HTSE via both thermal and electrical connection to the nuclear plant. High fidelity Modelica simulations showcase the viability of such control schemes. However, due to limited knowledge of solid oxide fuel cell (SOFC) stack degradation due to thermal gradients; thermal cycling of the HTSE was not included. Therefore, the control schemes proposed are only utilized to re-distribute steam at startup and only the portion of electricity utilized in the electrolyzers is cycled. From the detailed analysis of the nuclear integration and the HTSE process design, a comprehensive cost estimation was conducted in the APEA and H2A models to elucidate capital and operational costs associated with the production, compression, and distribution of hydrogen from a nuclear facility. Alongside this costing analysis, market analyses were conducted by NREL and ANL on the electric and hydrogen markets respectively in the PJM interconnect. Utilizing the electricity data market projections in the PJM interconnect from NREL and hydrogen demand/pricing projections from ANL a five variable sweep over component capacities, discount rates, and hydrogen pricing was completed using the stochastic framework RAVEN (Risk Analysis Virtual ENVironment) through its resource dispatch plugin HERON (Heuristic Energy Resource Optimization Network). Each combination of variables was evaluated stochastically four times over a seventeen year timespan from 2026-2042 (inclusive) to determine the most economically advantageous solution. Following the five variable sweep an optimization was conducted about the best sweep point to determine optimal component sizing and setpoints. Results suggest positive gain is achievable at all projected hydrogen market pricing levels and at all discount rates. However, exact component sizing and net returns vary based on these values and if incorrect sizing is selected; major net losses can occur. The optimal result occurred with set points as follows: high hydrogen prices, the largest possible HTSE unit in the sweep set at 7.47 kg/sec [645.4 tpd], a contractual hydrogen market agreement 7.29 kg/sec [629.8 tpd], and a hydrogen storage size 115,188 kg. The analysis suggested that with a discount rate of 8%, a ΔNPV = 1.2 billion over the seventeen year span can be achieved. The results illuminate that by operating in multiple markets the nuclear facility is capable of avoiding sale of electricity during times of low electricity market pricing, while maintaining the ability to capitalize on the high electricity market pricing. It should be noted that the analysis conducted in this report is a differential cash flow analysis and as such does not present profit levels. Instead it highlights the net benefit between building and competing in the hydrogen market utilizing nuclear facilities and conducting business as usual in the electricity markets. Additionally, results presented in this report exhibit conservatism due to four key assumptions: Given the limited knowledge on SOFC stack degradation due to thermal gradients the high temperature steam electrolysis plant is not allowed to thermally cycle. This limitation decreases electricity generation capacity in the nuclear plant, reducing capacity payments and the maximum output to the electrical grid. This analysis considers building a separate hydrogen pipeline for use in the nuclear facility. Research is currently being conducted to determine if existing natural gas pipelines can accommodate direct hydrogen injection. If hydrogen can be integrated into existing natural gas pipelines then a capital savings of ~$19,000,000 per kg/sec [1 kg/sec = 86.4 tpd] of installed HTSE capacity could be realized. Fast transients in the electric grid are typically served by flywheels and electric batteries. With electrolysis only operation the nuclear plant can flex its electricity just as quickly. However, for this analysis, the ancillary services market has been neglected. Should the nuclear plant have the ability to operate in the ancillary services market during periods when it is producing hydrogen, an additional substantial income stream that would increase overall system profitability could be considered. Subsidies for non-emitting generation technologies are not introduced in the cash flow analysis, but instead are completed assuming zero subsidies. Profitability is based solely on electricity pricing. Electric pricing is assumed to never go negative. Instead, it is assumed overall system curtailment by the Independent System Operator (ISO) will occur in such a manner that pricing remains at or above zero. This assumption inflates the “business as usual” scenario, thus decreasing the ΔNPV calculated. If negative pricing scenarios continue to occur as they do today, one would expect a further increase in ΔNPV. Overall, results advocate that, through market diversification, nuclear power plants have the potential to substantially increase current profit margins, increase market penetration, and ultimately solidify their place as a mainstay in energy production.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantification of Lanthanides in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy

To enable the deployment of molten salt reactor technology, the development of off-gas treatment systems and advanced monitoring tools capable of operating with high temperatures and radiation fields while delivering near real-time information is necessary. Here, we aim to fulfill this requirement and proposes laser-induced breakdown spectroscopy (LIBS) for monitoring molten salt aerosol streams. A sheath gas measuring method was developed to protect optical elements from aerosol particles and to ensure a relatively constant aerosol stream for measurement. An aqueous system was studied to demonstrate the utility of LIBS for monitoring possible fission products in an aerosol stream: Gd, Nd, and Sm up to 2000 parts per million (ppm). A calibration model was built using partial least squares (PLS) regression with five, six, and nine latent variables for Gd, Nd, and Sm, respectively. This calibration model successfully estimated the concentrations of three test samples, which were validated with inductively charged plasma optical emission spectroscopy measurements at a 99.9% confidence interval. To enhance these models, a genetic algorithm was used to filter the spectra before entering the PLS model, thereby limiting the spectral features being regressed to those with greater correlations to concentration. This allowed for the number of latent variables used in the PLS models to be reduced to four, three, and three for Gd, Nd, and Sm, respectively. Finally, the genetic algorithm-filtered PLS models were used to predict the concentrations of the aerosol stream on a real-time dataset and resulted in a 73%, 18%, and 25% improvement in root mean squared error of prediction compared to the original PLS models developed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Python Package for Fuel Cycle and Waste Management Analysis - 19545

The future of nuclear power utilization in the United States may involve a transition from the once-through light water reactor fuel cycle to a so-called advanced fuel cycle. An advanced fuel cycle may offer improvements in natural resource utilization, reactor safety, and environmental impact. In addition, adoption of an advanced fuel cycle will result in changes in the amount, composition, and disposal of the nuclear wastes they produce. Characteristics intrinsic to the wastes themselves, such as mass and radioactivity at specific times, were used as waste management metrics in the Department of Energy 2014 Fuel Cycle Evaluation and Screening (FCES) study. Binning of these metrics informed fuel cycle according to relative potential benefit. However, waste properties alone cannot qualify management strategy. Therefore, comparing fuel cycles from the perspective of waste management can provide additional insights. To that end, an object-oriented Python package has been developed to perform fuel cycle waste management calculations. The package, named nwpy (short for Nuclear Waste analysis in Python), mimics the mass flow operations reported in the FCES study and interfaces with the ORIGEN-S code to assess metric data as reported in the FCES. In addition, this Python package determines the loading of waste streams into forms suitable for final disposal in a geological repository and uses such data for repository performance assessment. This work describes the Python package methodology, assumptions, and capabilities. As input data, the package requires information about the fuel cycle such as the mass of fuel discharged, the cooling time between reactor discharge and subsequent operations, and the separations process efficiencies and waste forms it produces. In addition, the isotopic composition of the reactor discharge stream, such as that available from the FCES database, is required. With that, it can perform prescribed mass flow and decay operations throughout the back end of the fuel cycle, the latter carried out by the ORIGEN-S code distributed with the SCALE6.2 software suite. The result is time-dependent data characterizing the waste on a per-package basis. Package loading for waste streams depends on the stream form (i.e. UNF vs. HLW, or glass HLW from aqueous reprocessing vs. ceramic HLW from electrochemical processing) and is based on literature review and engineering assumption. As an example of the application of the code, calculations for the areal footprint of direct-contact repositories for different fuel cycles is shown. Development is ongoing, and the package is expected to grow incorporating capabilities for waste management analyses such as waste transportation and radionuclide transport through the biosphere. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combined Raman and Turbidity Probe for Real-Time Analysis of Variable Turbidity Streams

We know that real-time and in situ process monitoring is a powerful tool that can empower operators of hazardous processes to better understand and control their chemical systems without increased risk to themselves. However, applying monitoring techniques to complex chemical processes can face challenges. An example of this is the application of optical spectroscopy, otherwise capable of providing detailed chemical composition information, to processes exhibiting variable turbidity. Here, details on a novel combined Raman spectroscopy and turbidimetry probe are discussed. Furthermore, the analytical approach to accurately account for both Raman signal and turbidity while quantifying chemical targets is detailed. Through leveraging Raman and turbidity data simultaneously collected from the combined probe within chemometric models, accurate quantification of multiple chemical targets can be achieved under conditions of variable concentrations and turbidity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of historical operations information for supporting remedial investigation work at the former Harshaw Chemical Site - 8279.

In the early stages of hazardous, toxic, and radioactive waste (HTRW) site investigations, basic record searches are performed to help direct the agencies investigating contaminated sites to areas of concern and to identify contaminants of interest (COI). Plans developed on the basis of this preliminary research alone are often incomplete and result in unexpected discoveries either while in the field investigating the site or after the reports have been written. Many of the sites investigated under the Formerly Utilized Sites Remedial Action program (FUSRAP) have complex histories that are slowly uncovered over the life of the project. Because of programmatic constraints, nuances of these sites are often discovered late in their programs and result in increased expenditures in order to fully characterize the site, perform a robust feasibility study, and recommend appropriate alternatives for remediation. By identifying resources for public records, classified records, historic aerial photographs, and other sources of site-specific historical information, a process can be established to optimize the collection of information and to develop efficient and complete project plans. In many cases, interviews with past site employees are very useful tools. In combining what is found in the records, observed on historic aerial photographs, and heard from former employees and family members, teams investigating these sites can begin to compile sound and more complete conceptual site models (CSMs). The former Harshaw Chemical Site (HCS) illustrates this discovery process. HCS is part of FUSRAP. Preliminary investigations by the US Department of Energy (DOE) in the 1970s provided an initial CSM of activities that had taken place that may have resulted in contamination. The remedial investigation (RI) conducted by the US Army Corps of Engineers (USACE) was designed around this CSM. The RI work, however, identified a number of site conditions that were unexpected, including new potential COI associated with recycled uranium and contaminant locations that were inconsistent with the original CSM. As part of an RI Addendum effort, the USACE reconsidered its understanding of HCS historical activities. This effort included an intensive review of available historical aerial photography, an in-depth Potentially Responsible Parties (PRP) investigation, additional analysis of the production processes in place at HCS, and targeted supplemental data collection. The result of this effort was a revised CSM that included a number of previously unidentified potential COI and a much clearer understanding of the processes and resulting waste streams potentially associated with environmental contamination. Because of their complex and often poorly documented operational histories, unexpected discoveries will always be a part of investigating sites such as HCS. Taking advantage of available resources and expending funds for thorough historical research early in the life of a project will help to reduce the chances for expensive field remobilizations and significant schedule delays. A complete and accurate site history also allows for more efficient long-term technical and budgetary planning, thus eliminating many obstacles associated with the ultimate disposition of HTRW sites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Role of Historical Operations Information for Supporting Remedial Investigation Work at the Former Harshaw Chemical Site

In the early stages of hazardous, toxic, and radioactive waste (HTRW) site investigations, basic record searches are performed to help direct the agencies investigating contaminated sites to areas of concern and to identify contaminants of interest (COI). Plans developed on the basis of this preliminary research alone are often incomplete and result in unexpected discoveries either while in the field investigating the site or after the reports have been written. Many of the sites investigated under the Formerly Utilized Sites Remedial Action Program (FUSRAP) have complex histories that are slowly uncovered over the life of the project. Because of programmatic constraints, nuances of these sites are often discovered late in their programs and result in increased expenditures in order to fully characterize the site, perform a robust feasibility study, and recommend appropriate alternatives for remediation. By identifying resources for public records, classified records, historic aerial photographs, and other sources of site-specific historical information, a process can be established to optimize the collection of information and to develop efficient and complete project plans. In many cases, interviews with past site employees are very useful tools. In combining what is found in the records, observed on historic aerial photographs, and heard from former employees and family members, teams investigating these sites can begin to compile sound and more complete conceptual site models (CSM(s). The former Harshaw Chemical Site (HCS) illustrates this discovery process. HCS is part of FUSRAP. Preliminary investigations by the U.S. Department of Energy (DOE) in the 1970's provided an initial CSM of activities that had taken place that may have resulted in contamination. The remedial investigation (RI) conducted by the U.S. Army Corps of Engineers (USACE) was designed around this CSM. The RI work, however, identified a number of site conditions that were unexpected, including new potential COI associated with recycled uranium and contaminant locations that were inconsistent with the original CSM. As part of an RI Addendum effort, the USACE reconsidered its understanding of HCS historical activities. This effort included an intensive review of available historical aerial photography, an in-depth Potentially Responsible Parties (PRP) investigation, additional analysis of the production processes in place at HCS, and targeted supplemental data collection. The result of this effort was a revised CSM that included a number of previously unidentified potential COI and a much clearer understanding of the processes and resulting waste streams potentially associated with environmental contamination. Because of their complex and often poorly documented operational histories, unexpected discoveries will always be a part of investigating sites such as HCS. Taking advantage of available resources and expending funds for thorough historical research early in the life of a project will help to reduce the chances for expensive field re-mobilizations and significant schedule delays. A complete and accurate site history also allows for more efficient long-term technical and budgetary planning, thus eliminating many obstacles associated with the ultimate disposition of HTRW sites. (authors)

54 ENVIRONMENTAL SCIENCES↗

A White Paper: Disposition Options for a High-Temperature Gas-Cooled Reactor

The high-temperature gas-cooled reactor (HTGR) is a uranium-fueled, graphite-moderated, gas-cooled nuclear reactor design concept capable of producing very high core outlet temperatures. Both types of HTGR have the tristructural isotropic (TRISO) fuel kernel at the heart of the fuel design. For the prismatic block-type HTGR, the TRISO particles are overcoated with a resinated graphitic matrix and pressed into fuel compacts, which are then heat treated and placed in the fuel channels of the prismatic-block-shaped fuel assemblies. For the pebble-bed-type HTGR, the TRISO particles are dispersed in a graphitic-matrix sphere, which is the basic unit for the reactor core. Despite having very different fuel designs, both types of HTGR are graphite-moderated, gas-cooled, thermal reactors using many of the same materials. As a result, both prismatic-block-type and pebble-bed-type HTGRs have similar radioactive waste streams, all of which require safe and secure storage and eventual disposition. Modern HTGR designs are based on a long and rich operating history of several different graphite-moderated, gas-cooled, thermal reactors. Several of these reactors have been shut down, the fuel has been placed in safe storage, and they have undergone some degree of decommissioning. As such, there is significant experience in the management of the spent nuclear fuel (SNF) and radioactive wastes associated with operating these reactors. This white paper will, (1) identify the definitions and regulations that apply to the safe and secure management, storage, and disposal of radioactive waste; and (2) identify the key radioactive waste streams from HTGRs and their characteristics. Idaho National Laboratory (INL) has significant experience in the management of SNF from HTGR predecessors. This experience should form the basis for the management and disposition efforts of the radioactive waste from any new HTGR-type small modular reactor, or microreactor intended for deployment at the INL site.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

POLYMER ELECTROLYTE MEMBRANE ELECTROLYZER OPERATION WITH VARYING INLET WATER FEED CONFIGURATIONS

Proton Exchange Membrane (PEM) electrolysis is a potential alternative technology to crack water in specialty applications where a dry gas stream is needed, such as isotope production. One design proposal is to feed the cathode of the electrolyzer with vapor phase water. This feed configuration would allow isotopic water to be isolated on the cathode side of the electrolyzer and the isotope recovery system could be operated in a closed loop. Tests were performed to characterize the difference in the current-voltage behavior between a PEM electrolyzer operated with a cathode water vapor feed and with an anode liquid water feed. The cathode water vapor feed cell had a maximum limiting current density of 100 mA/cm2 at 70 C compared to a current density of 800 mA/cm2 for the anode liquid feed cell at 70 C. The limiting current densities for the cathode water vapor feed cell were approximately 3 times lower than predicted by a water mass transfer model. It is estimated that a cathode water vapor feed electrolyzer system will need to be between 8-14 times larger in active area or number of cells than an anode liquid feed system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Role of the Consequence Management Home Team in the Fukushima Daiichi Response

The Consequence Management Home Team (CMHT) is a U.S. Department of Energy/National Nuclear Security Administration asset and played an important role in the U.S. response effort to the Fukushima Daiichi accident, ranging from the early days of the response to a continued involvement in supporting late phase efforts. Each stage of their work had distinct characteristics in terms of management of incoming data streams and creation of products. The CMHT assisted a variety of response organizations with modeling; radiological operations planning; field monitoring techniques; and the analysis, interpretation, and distribution of radiological data. In the Fukushima Daiichi response, the CMHT grew to include a broader range of support than was historically planned. Through their work, the social and economic impacts of a nuclear or radiological incident were minimized. The CMHT was an integral component of the response in Japan and acted as the central point from which all of the data and products flowed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

One System Overview - 16579

The U.S. Department of Energy (DOE), Office of River Protection (ORP) is responsible for managing and completing the River Protection Project mission, which is to 'safeguard the nuclear waste stored in Hanford's 177 underground tanks, and to manage the waste safely and responsibly until it can be treated in the Waste Treatment and Immobilization Plant for final disposition'. The Office of River Protection's work scope is currently performed through two primary contracts: - The Tank Operations Contract, held by Washington River Protection Solutions LLC, (WRPS) includes the construction, operation, and maintenance activities necessary to safely store, retrieve, and transfer tank wastes; provide supplemental tank waste treatment; provide storage and/or disposal of primary and secondary waste streams; design, construction and commissioning of the Low-Activity Waste Pretreatment System; and support ORP to integrate Hanford Tank Waste Treatment and Immobilization Plant (WTP) completion and startup with Tank Farms operations. - The WTP Contract, held by Bechtel National, Inc. (BNI), includes the design, construction, and commissioning of a Pretreatment Facility, two vitrification facilities (one for high-level waste and one for low-activity waste), a dedicated analytical laboratory, and supporting facilities to treat radioactive tank wastes by immobilizing them into a stable glass waste form. One System was established as a means to improve the integration between the tank farms and the WTP project to support its safe and successful startup. One System's scope and purpose focus on mission integration consistent with DOE's plans to treat tank waste in phases, starting with direct feed of the low-activity waste stream to the WTP's Low-Activity Waste (LAW) Vitrification Facility (referred to as DFLAW). The One System organization now has four major focus areas: - Flowsheet Integration? Integrated River Protection Project (RPP) flowsheet development and management; developing a gaps, risks, and opportunities management plan and technical roadmap; and waste feed qualification. - Mission Analysis and Planning? Strategic planning, system planning, and modeling integration. - WTP Startup, Commissioning, and Operations Integration? Interface Control Document (ICD) management, coordinating facilities startup-to-commissioning-to-operations, contract directives and standards identification, and DFLAW program integration. - Project Integration and Controls? Integrated schedule, metrics/dashboards monitoring, and One System risk register. ORP established the DFLAW Program Office in February 2015 as one of its key performance goals. ORP staff, along with contractor managers, have identified roles and responsibilities for the each of the four major focus areas. One System has established an Executive Council and Governance Board to drive program progress and make decisions on DFLAW. This approach allows appropriate government and contractor senior management involvement in the DFLAW Program. Monthly critical path analysis on the integrated DFLAW schedule is being performed. Interface control documents specific to DFLAW have been developed, and system planning and modeling tools are being used to help define the DFLAW flowsheet. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗