Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software tools”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Ion Mobility Spectrometry-Mass Spectrometry for High-Throughput Analysis

Ion mobility spectrometry is a widely used analytical technique providing gas phase separation of molecules. It has received increasing attention in the recent years with the advancement in technology development and the availability of commercial instruments. In this chapter, we introduced the ion mobility fundamental theory and provided examples of IMS applications, especially for isomer separation, collision cross section database generation, high throughput analysis workflows, software tools for IMS data analysis, and ongoing high resolution SLIM IMS development. While IMS is not yet routinely utilized in drug discovery and pharmaceutical industry, there has been increased interest in high throughput library screening and antibody characterization. With all the ongoing development in IMS technology and informatics, we foresee more and more exciting applications of high throughput IMS analysis in different fields including omics studies, drug discovery and clinical applications in the near future.

Ross, Dylan H.↗

Unambiguous metabolite identification in high-throughput metabolomics by hybrid 1D 1 H NMR/ESI MS 1 approach: Hybrid 1D 1 H NMR/ESI MS 1 metabolomics method

We present a novel approach to improve accuracy of metabolite identification by combining direct infusion ESI MS1 with 1D 1H NMR spectroscopy. The new approach first applies standard 1D 1H NMR metabolite identification protocol by matching the chemical shift, J-coupling and intensity information of experimental NMR signals against the NMR signals of standard metabolites in metabolomics library. This generates a list of candidate metabolites. The list contains false positive and ambiguous identifications. Next, we constrained the list with the chemical formulas derived from high-resolution direct infusion ESI MS1 spectrum of the same sample. Detection of the signals of a metabolite both in NMR and MS significantly improves the confidence of identification and eliminates false positive identification. 1D 1H NMR and direct infusion ESI MS1 spectra of a sample can be acquired in parallel in several minutes. This is highly beneficial for rapid and accurate screening of hundreds of samples in high-throughput metabolomics studies. In order to make this approach practical, we developed a software tool, which is integrated to Chenomx NMR Suite. The approach is demonstrated on a model mixture, tomato and Arabidopsis thaliana metabolite extracts, and human urine.

Environmental Molecular Sciences Laboratory↗

Proteome and Transcriptome Profiles of a Her2/Neu-driven Mouse Model of Breast Cancer

In recent years, mouse models have proven to be invaluable in expanding our understanding of cancer biology. We have amassed a tremendous amount of proteomics and transcriptomics data profiling blood and tissues from a Her2-driven mouse model of breast cancer that closely recapitulates the pathology and natural history of human breast cancer. The purpose of this report is to make all of these data publicly available in raw and processed forms, as a resource to the community. Importantly, high quality biospecimens from this same mouse model are freely available through a sample repository that we established, so researchers can readily obtain samples to test biological hypotheses without the need of breeding animals and collecting biospecimens. Specifically, six proteomics and six transcriptomics datasets are available, with the former encompassing 841 liquid chromatography-tandem mass spectrometry (LC-MS/MS) experiments of both plasma and tissue samples, and the latter including 255 individual microarray analyses of five different tissue types (thymus, spleen, liver, blood cells, and breast ± laser capture microdissection). A total of 18,880 unique peptides were identified with a PeptideProphet error rate ≤1%, with 3884 non-redundant protein groups identified in five plasma datasets, and 1659 non-redundant protein groups in a tissue dataset (4977 non-redundant protein groups in total). We anticipate that these data will be of use to the community for software tool development, investigations of analytical variation in MS/MS data, development of quality control tools (multiple technical replicates are provided for a subset of the data), empirical selection of proteotypic peptides for multiple reaction monitoring mass spectrometry, and for advancing our understanding of cancer biology.

59 BASIC BIOLOGICAL SCIENCES↗

De novo design and Rosetta-based assessment of high-affinity antibody variable regions (Fv) against the SARS-CoV -2 spike receptor binding domain ( RBD )

The continued emergence of new SARS-CoV-2 variants has accentuated the growing need for fast and reliable methods for the design of potentially neutralizing antibodies (Abs) to counter immune evasion by the virus. Here, we report on the de novo computational design of high-affinity Ab variable regions (Fv) through the recombination of VDJ genes targeting the most solvent-exposed hACE2-binding residues of the SARS-CoV-2 spike receptor binding domain (RBD) protein using the software tool OptMAVEn-2.0. Subsequently, we carried out computational affinity maturation of the designed variable regions through amino acid substitutions for improved binding with the target epitope. Immunogenicity of designs was restricted by preferring designs that match sequences from a 9-mer library of “human Abs” based on a human string content score. We generated 106 different antibody designs and reported in detail on the top five that trade-off the greatest computational binding affinity for the RBD with human string content scores. We further describe computational evaluation of the top five designs produced by OptMAVEn-2.0 using a Rosetta-based approach. We used Rosetta SnugDock for local docking of the designs to evaluate their potential to bind the spike RBD and performed “forward folding” with DeepAb to assess their potential to fold into the designed structures. Ultimately, our results identified one designed Ab variable region, P1.D1, as a particularly promising candidate for experimental testing. This effort puts forth a computational workflow for the de novo design and evaluation of Abs that can quickly be adapted to target spike epitopes of emerging SARS-CoV-2 variants or other antigenic targets.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluating causal‐based feature selection for fuel property prediction models

Abstract In‐silico screening of novel biofuel molecules based on chemical and fuel properties is a critical first step in the biofuel evaluation process due to the significant volumes of samples required for experimental testing, the destructive nature of engine tests, and the costs associated with bench‐scale synthesis of novel fuels. Predictive models are limited by training sets of few existing measurements, often containing similar classes of molecules that represent just a subset of the potential molecular fuel space. Software tools can be used to generate every possible molecular descriptor for use as input features, but most of these features are largely irrelevant and training models on datasets with higher dimensionality than size tends to yield poor predictive performance. Feature selection has been shown to improve machine learning models, but correlation‐based feature selection fails to provide scientific insight into the underlying mechanisms that determine structure–property relationships. The implementation of causal discovery in feature selection could potentially inform the biofuel design process while also improving model prediction accuracy and robustness to new data. In this study, we investigate the benefits causal‐based feature selection might have on both model performance and identification of key molecular substructures. We found that causal‐based feature selection performed on par with alternative filtration methods, and that a structural causal model provides valuable scientific insights into the relationships between molecular substructures and fuel properties.

Nguyen, Bernard↗

Industrial Inspection with Open Eyes: Advance with Machine Vision Technology

Machine vision systems have evolved significantly with the technology advances to tackle the challenges from modern manufacturing industry. A wide range of industrial inspection applications for quality control are benefiting from visual information captured by different types of cameras variously configured in a machine vision system. This chapter screens the state of the art in machine vision technologies in the light of hardware, software tools, and major algorithm advances for industrial inspection. The inspection beyond visual spectrum offers a significant complementary to the visual inspection. The combination with multiple technologies makes it possible for the inspection to achieve a better performance and efficiency in varied applications. The diversity of the applications demonstrates the great potential of machine vision systems for industry.

acoustic↗

Developing Ultrahigh-Resolution E3SM Land Model for GPU Systems

Designing and refactoring complex scientific code, such as the E3SM land model (ELM), for new computing architectures is challenging. This paper presents design strategies and technical approaches to develop a data-oriented, GPU-ready ELM model using compiler directives (OpenACC/OpenMP). We first analyze the datatypes and processes in the original ELM code. Then we present design considerations for ultrahigh-resolution ELM (uELM) development for massive GPU systems. These techniques include the global data-oriented simulation workflow, domain partition, code porting and data copy, memory reduction, parallel loop restructure and flattening, and race condition detection. We implemented the first version of uELM using OpenACC targeting the NVidia GPUs in the Summit supercomputer at Oak Ridge National Laboratory. During the implementation, we developed a software tool (named SPEL) to facilitate code generation, verification, and performance tuning using these techniques. The first uELM implementation for Nvidia GPUs on Summit delivered promising results: 1) over 98% of the ELM code was automatically generated and tuned by scripts. Most ELM modules had better computational performances than the original ELM code for CPUs. The GPU-ready uELM is more scalable than the CPU code on fully-loaded Summit nodes. Example profiling results from several modules are also presented to illustrate the performance improvements and race condition detection. The lessons learned and toolkit developed in the study are also suitable for further uELM deployment using OpenMP on the first US exascale computer, Frontier, equipped with AMD CPUs and GPUs.

Schwartz, Peter↗

Dynamic Operations Wayfinding System (DOWS) for Nuclear Power Plants

A novel software tool is proposed to aid reactor operators in respond- ing to upset plant conditions. The purpose of the Dynamic Operations Wayfind- ing System (DOWS) is to diagnose faults, prioritize those faults, identify paths to resolve those faults, and deconflict the optimal path for the operator to fol- low. The objective of DOWS is to take the guesswork out of the best way to combine procedures to resolve compound faults, mitigate low threshold events, or respond to severe accidents. DOWS represents a uniquely flexible and dy- namic computer-based procedure system for operators.

computer-based procedure↗

Bootstrapping the 3d Ising stress tensor

We compute observables of the critical 3d Ising model to high precision by applying the numerical conformal bootstrap to mixed correlators of the leading scalar operators σ and ϵ, and the stress tensor T μν . We obtain new precise determinations of scaling dimensions (∆ σ , ∆ ϵ ) = (0.518148806(24), 1.41262528(29)) as well as OPE coefficients involving σ, ϵ, and T μν . We also describe several improvements made along the way to algorithms and software tools for the numerical bootstrap.

Conformal and W Symmetry↗

Estimation of split renal function using different volumetric methods: inter- and intraindividual comparison between MRI and CT

Purpose: This study aims to determine whether contrast-enhanced (CE)-magnetic resonance imaging (MRI) is comparable to CE-computed tomography (CT) for estimation of split renal function (SRF). For this purpose, two different kidney volumetry methods, the renal cortex volumetry (RCV) and modified ellipsoid volume (MELV), are compared for both acquisition types (CT vs. MRI) with regard to accuracy and reliability, subsequently referred to as RCV{sub CT}/RCV{sub MRI} and MELV{sub CT}/MELV{sub MRI}. Methods: This retrospective study included 29 patients (18 men and 11 women; mean age 62.8 ± 12.4 years) who underwent CE-MRI and CE-CT of the abdomen within a period of 3 months. Two independent readers (R1/R2) performed RCV and MELV in all datasets with corresponding semiautomated software tools. RCV was performed with datasets in the arterial phase and MELV in the venous phase. Statistics were calculated using one-way ANOVA, two-tailed Student’s t test, Pearson´s correlation, and Bland–Altman plots with p ≤ 0.05 being considered statistically significant. Results: In all datasets, SRF was almost identical for both volumetry methods with a mean difference of < 1%. Bland–Altman analysis comparing RCV in CT and MRI showed very good agreement for R1/R2. Interreader agreement was strong for RCV{sub CT} and good for RCV{sub MRI} (r = 0.89; r = 0.69). MELV{sub CT/MRI} interreader agreement was only moderate (r = 0.54; r = 0.50) with a high range of values. Intrareader agreement was excellent for all measurements, except MELV{sub MRI} which showed a high mean bias and range of values (RCV{sub CT}: r = 0.93, RCV{sub MRI}: r = 0.98, MELV{sub CT}: r = 0.89, MELV{sub MRI}: r = 0.54). Conclusion: Renal volumetric estimates of SRF are almost as accurate and reliable with CE-MRI as with CE-CT using RCV method. In distinction, the calculation of SRF using MELV was inferior to RCV with respect to accuracy and reliability. Thus, RCV method is recommended to estimate SRF, primarily using CT datasets. However, RCV with MRI datasets for kidney volumetry allows for comparable accuracy and reliability while sparing patients and healthy donors of unnecessary radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation of Liver Metastases-Software-Assisted Evaluation of the Ablation Zone in MDCT: Tumor-Free Follow-Up Versus Local Recurrent Disease

The purpose of this study was to investigate differences in change of size and CT value between local recurrences and tumor-free areas after CT-guided radiofrequency ablation (RFA) of hepatic metastases during follow-up by means of dedicated software for automatic evaluation of hepatic lesions. Thirty-two patients with 54 liver metastases from breast or colorectal cancer underwent triphasic contrast-enhanced multidetector-row computed tomography (MDCT) to evaluate hepatic metastatic spread and localization before CT-guided RFA and for follow-up after intervention. Sixteen of these patients (65.1 {+-} 10.3 years) with 30 metastases stayed tumor-free (group 1), while the other group (n = 16 with 24 metastases; 62.0 {+-} 13.8 years) suffered from local recurrent disease (group 2). Applying an automated software tool (SyngoCT Oncology; Siemens Healthcare, Forchheim, Germany), size parameters (volume, RECIST, WHO) and attenuation were measured within the lesions before, 1 day after, and 28 days after RFA treatment. The natural logarithm (ln) of the quotient of the volume 1 day versus 28 days after RFA treament was computed: lnQ1//28/0{sub volume}. Analogously, ln ratios of RECIST, WHO, and attenuation were computed and statistically evaluated by repeated-measures ANOVA. One lesion in group 2 was excluded from further evaluation due to automated missegmentation. Statistically significant differences between the two groups were observed with respect to initial volume, RECIST, and WHO (p < 0.05). Furthermore, ln ratios corresponding to volume, RECIST, and WHO differed significantly between the two groups. Attenuation evaluations showed no significant differences, but there was a trend toward attenuation assessment for the parameter lnQ28/0{sub attenuation} (p = 0.0527), showing higher values for group 1 (-0.4 {+-} 0.3) compared to group 2 (-0.2 {+-} 0.2). In conclusion, hepatic metastases and their zone of coagulation necrosis after RFA differed significantly between tumor-free and local-recurrent ablation zones with respect to the corresponding size parameters. A new parameter (lnQ1//28/0{sub volume/RECIST/WHO/attenuation}) was introduced, which appears to be of prognostic value at early follow-up CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Approach for Preoperative Planning and Performance of MR-guided Interventions Demonstrated With a Manual Manipulator in a 1.5T MRI Scanner

Purpose: The aim of this work was to develop and test a general methodology for the planning and performance of robot-assisted, MR-guided interventions. This methodology also includes the employment of software tools with appropriately tailored routines to effectively exploit the capabilities of MRI and address the relevant spatial limitations. Methods: The described methodology consists of: (1) patient-customized feasibility study that focuses on the geometric limitations imposed by the gantry, the robotic hardware, and interventional tools, as well as the patient; (2) stereotactic preoperative planning for initial positioning of the manipulator and alignment of its end-effector with a selected target; and (3) real-time, intraoperative tool tracking and monitoring of the actual intervention execution. Testing was performed inside a standard 1.5T MRI scanner in which the MR-compatible manipulator is deployed to provide the required access. Results: A volunteer imaging study demonstrates the application of the feasibility stage. A phantom study on needle targeting is also presented, demonstrating the applicability and effectiveness of the proposed preoperative and intraoperative stages of the methodology. For this purpose, a manually actuated, MR-compatible robotic manipulation system was used to accurately acquire a prescribed target through alternative approaching paths. Conclusions: The methodology presented and experimentally examined allows the effective performance of MR-guided interventions. It is suitable for, but not restricted to, needle-targeting applications assisted by a robotic manipulation system, which can be deployed inside a cylindrical scanner to provide the required access to the patient facilitating real-time guidance and monitoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mesh generation for confined fusion plasma simulation

XGC1 and M3D-C 1 are two fusion plasma simulation codes being developed at Princeton Plasma Physics Laboratory. XGC1 uses the particle-in-cell method to simulate gyrokinetic neoclassical physics and turbulence. M3D-C 1 solves the two-fluid resistive magnetohydrodynamic equations with the C 1 finite elements. This paper presents the software tools and libraries that were combined to form the geometry and automatic meshing procedures for these codes. Finally, specific consideration has been given to satisfy the mesh configuration and element shape quality constraints of XGC1 and M3D-C 1 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-Center Experience Implementing the LOINC-RSNA Radiology Playbook for Adult Abdomen/Pelvis CT and MR Procedures Using a Semi-Automated Method

The LOINC-RSNA Radiology Playbook represents the future direction of standardization for radiology procedure names. We developed a software solution (“RadMatch”) utilizing Python 2.7 and FuzzyWuzzy, an open-source fuzzy string matching algorithm created by SeatGeek, to implement the LOINC-RSNA Radiology Playbook for adult abdomen and pelvis CT and MR procedures performed at our institution. Execution of this semi-automated method resulted in the assignment of appropriate LOINC numbers to 86% of local CT procedures. For local MR procedures, appropriate LOINC numbers were assigned to 75% of these procedures whereas 12.5% of local MR procedures could only be partially mapped. For the standardized local procedures, only 63% of CT and 71% of MR procedures had corresponding RadLex Playbook identifier (RPID) codes in the LOINC-RSNA Radiology Playbook, which limited the utility of RPID codes. RadMatch is a semi-automated open-source software tool that can assist radiology departments seeking to standardize their radiology procedures via implementation of the LOINC-RSNA Radiology Playbook.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synthetic biology of polyketide synthases

Abstract Complex reduced polyketides represent the largest class of natural products that have applications in medicine, agriculture, and animal health. This structurally diverse class of compounds shares a common methodology of biosynthesis employing modular enzyme systems called polyketide synthases (PKSs). The modules are composed of enzymatic domains that share sequence and functional similarity across all known PKSs. We have used the nomenclature of synthetic biology to classify the enzymatic domains and modules as parts and devices, respectively, and have generated detailed lists of both. In addition, we describe the chassis (hosts) that are used to assemble, express, and engineer the parts and devices to produce polyketides. We describe a recently developed software tool to design PKS system and provide an example of its use. Finally, we provide perspectives of what needs to be accomplished to fully realize the potential that synthetic biology approaches bring to this class of molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed analysis in CMS

The CMS experiment expects to manage several Pbytes of data each year during the LHC programme, distributing them over many computing sites around the world and enabling data access at those centers for analysis. CMS has identified the distributed sites as the primary location for physics analysis to support a wide community with thousands potential users. This represents an unprecedented experimental challenge in terms of the scale of distributed computing resources and number of user. An overview of the computing architecture, the software tools and the distributed infrastructure is reported. Summaries of the experience in establishing efficient and scalable operations to get prepared for CMS distributed analysis are presented, followed by the user experience in their current analysis activities.

99 GENERAL AND MISCELLANEOUS↗

Applying queueing theory to evaluate wait-time-savings of triage algorithms

Abstract In the past decade, artificial intelligence (AI) algorithms have made promising impacts in many areas of healthcare. One application is AI-enabled prioritization software known as computer-aided triage and notification (CADt). This type of software as a medical device is intended to prioritize reviews of radiological images with time-sensitive findings, thus shortening the waiting time for patients with these findings. While many CADt devices have been deployed into clinical workflows and have been shown to improve patient treatment and clinical outcomes, quantitative methods to evaluate the wait-time-savings from their deployment are not yet available. In this paper, we apply queueing theory methods to evaluate the wait-time-savings of a CADt by calculating the average waiting time per patient image without and with a CADt device being deployed. We study two workflow models with one or multiple radiologists (servers) for a range of AI diagnostic performances, radiologist’s reading rates, and patient image (customer) arrival rates. To evaluate the time-saving performance of a CADt, we use the difference in the mean waiting time between the diseased patient images in the with-CADt scenario and that in the without-CADt scenario as our performance metric. As part of this effort, we have developed and also share a software tool to simulate the radiology workflow around medical image interpretation, to verify theoretical results, and to provide confidence intervals for the performance metric we defined. We show quantitatively that a CADt triage device is more effective in a busy, short-staffed reading setting, which is consistent with our clinical intuition and simulation results. Although this work is motivated by the need for evaluating CADt devices, the evaluation methodology presented in this paper can be applied to assess the time-saving performance of other types of algorithms that prioritize a subset of customers based on binary outputs.

Thompson, Yee Lam Elim (ORCID:0000000196537707)↗

Enabling modern data discovery for atmospheric measurements

The Atmospheric Radiation Measurement (ARM) user facility is a US Department of Energy Office of Science user facility that is managed and operated through a collaborative effort led by nine US Department of Energy national laboratories. The ARM Data Center, located at Oak Ridge National Laboratory, is responsible for the timely collection, processing, and delivery of data products to the scientific community. The ARM Data Center holds more than 11,000 data products, including metadata collected from field campaigns, instruments, value-added products, and principal investigator–contributed data. These data sets are checked for successful transfer (for most data, this transfer is carried out automatically via the network; however, some of the largest data sets and some of the most remote sites require manual shipping of hard disks) and both the data and metadata are processed to a standard format, which is an ARM-standardized structure, via the Network Common Data Form. The Network Common Data Form is a self-describing binary format with many compatible software tools. Once processed, the data are cataloged, stored in the ARM Data Archive, and made discoverable through association with an array of metadata-characterizing information, such as location and measurement classification. These metadata enable powerful search capabilities through the ARM Data Center Data Discovery interface. This paper discusses the workflow of how the new discovery system has been redesigned from user requirements and how the data are distributed to the scientific community.

54 ENVIRONMENTAL SCIENCES↗