Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Automated vehicle guidance using discrete reference markers

Techniques for providing steering control for an automated vehicle using discrete reference markers fixed to the road surface are investigated analytically. Either optical or magnetic approaches can be used for the sensor, which generates a measurement of the lateral offset of the vehicle path at each marker to form the basic data for steering control. Possible mechanizations of sensor and controller are outlined. Techniques for handling certain anomalous conditions, such as a missing marker, or loss of acquisition, and special maneuvers, such as u-turns and switching, are briefly discussed. A general analysis of the vehicle dynamics and the discrete control system is presented using the state variable formulation. Noise in both the sensor measurement and in the steering servo are accounted for. An optimal controller is simulated on a general purpose computer, and the resulting plots of vehicle path are presented. Parameters representing a small multipassenger tram were selected, and the simulation runs show response to an erroneous sensor measurement and acquisition following large initial path errors.

Johnston, A. R.↗

Vibration-based health characterization of multiple IMUs in UAV applications

Inertial measurement units (IMUs) are vital in UAV navigation for vehicle attitude and position estimation, especially in the frequently-occurring case of temporary loss of GPS capabilities. Degradation in these units could yield inaccurate position estimates, resulting in incorrect input for vehicle control systems. A wide variety of these units exist to meet the needs of UAV operators, general aviation, and military vehicles. In recent decades, lightweight and inexpensive MEMS sensors have grown in popularity with respect to UAVs. Studies into the failure modes of MEMS devices suggest that vibration is one of the leading causes of MEMS degradation. MEMS sensors are generally encased in their own hermetic packaging, as their small size and sensitivity cause them to be particularly vulnerable to air damping and particulate contamination when exposed. Exposure to excessive vibration can cause cracking in this packaging as well as damage to connecting electronics, with recorded results that cause sensors to act outside of their specifications, potentially providing unreliable input to controllers. A prior study from the Politecnico di Torino looked into the degradation of MEMS IMUs, specifically the AXIS-AIS402, for aerospace and vibrating environments. In the study, the authors found that after exposing MEMS IMUs to simulated vibrations from working conditions of aerospace applications, the sensors showed increased noise and increased bias instability. At NASA Ames, several widely-used MEMS IMUs were selected for a new IMU degradation study, comparing accelerometer performance before and after exposure to similar levels of vibration simulating aerospace conditions. The IMUs were selected from the Pixhawk autopilot systems, hobby sUAS, or prior experimental studies at NASA. Additionally, the industrial grade VectorNav-100 IMU was selected as a ground truth reference point to which the performance of the test sensors can be compared. In the study, each sensor is exposed to functional levels of UAV vibration as replicated on a single-frequency vibratory table in the NASA Ames SHARP Laboratory, and each accelerometer is characterized for bias, drift, and noise characteristics both before and after vibratory exposure. The focus of this study is to monitor the health of the IMU sensors and determine if sensor degradation can be detected from output error and frequency spectrum analysis, rather than from microscopic examination of the sensors. In this case, sensor degradation and faulty data can be more easily detectable by non-experts hoping to use these sensors as an important piece of an integrated package. In addition, specific sensor degradation modes potentially leading to in-flight hazards could be identified, such as accelerated levels of drift and altered temperature response. The overall goal of this work is to increase levels of safety for future users of these sensors and to provide a clear analysis of sensor limitations currently lacking in most sensor specification documentation.

IMUs↗

Standalone Hazard Evaluation and Refinement From Instrument Findings (S.H.E.R.I.F)

SHERIF is a novel algorithm which defines a unique, non-iterative method for the combination of LiDAR scans into a Digital Elevation Map (DEM) and the simultaneous evaluation of that DEM for Safe Site Selection (SSL) and Hazard Detection (HD). This creates a sensor independent method for a spacecraft conducting Entry Descent and Landing (EDL) operations to synthesize terrain scans and generate a more complete and evolving understanding of the landing site topography as well as the associated hazards. SHERIF aims to increase safety and mission success probability by more effectively using the data from a single sensor to increase situational awareness, knowledge of the landing site and its hazards, as well as informing a more streamlined transition from Terrain Relative Navigation (TRN) to Hazard Relative Navigation (HRN) during descent.

Hazard Detection↗

Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection

Here, a straightforward in situ detection method for dengue infection was demonstrated through the molecular imprinting of a dengue nonstructural protein 1 (NS1) epitope into an electropolymerized molecularly imprinted polyterthiophene (E-MIP) film sensor. The key enabling step in the sensor fabrication is based on an epitope imprinting strategy, in which short peptide sequences derived from the original target molecules were employed as the main template for detection and analysis. The formation of the E-MIP sensor films was facilitated using cyclic voltammetry (CV) and monitored in situ by electrochemical quartz crystal microbalance (EC-QCM). Surface properties were analyzed using different techniques including atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and polarization modulation-infrared reflection-adsorption (PM-IRRAS). The standard calibration curve (R = 0.9830) was generated for the detection of the epitope, Ac-VHTWTEQYKFQ-NH 2 , with a linear range of 0.2 to 30 μg/mL and detection limit of 0.073 μg/mL. A separate calibration curve (R = 0.9786) was obtained using spiked buffered solutions of dengue NS1 protein, which resulted in a linear range of 0.2 to 10 μg/mL and a detection limit of 0.056 μg/mL. The fabricated E-MIP sensor exhibited long-term stability, high sensitivity, and good selectivity towards the targeted molecules. These results indicated that the formation of the exact and stable cavity imprints in terms of size, shape, and functionalities was successful. In our future work, we aim to use our E-MIP sensors for NS1 detection in real-life samples such as serum and blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Label-Free Detection of Cardiac Troponin-I Using Carbon Nanofiber Based Nanoelectrode Arrays

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. A carbon nanofiber (CNF) multiplexed array has been fabricated with 9 sensing pads, each containing 40,000 carbon nanofibers as nanoelectrodes. Here, we report the use of vertically aligned CNF nanoelectrodes for the detection of cardiac Troponin-I for the early diagnosis of myocardial infarction. Antibody, antitroponin, probe immobilization and subsequent binding to human cardiac troponin-I were characterized using electrochemical impedance spectroscopy and cyclic voltammetry techniques. Each step of the modification process resulted in changes in electrical capacitance or resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific antigen. This sensor demonstrates high sensitivity, down to 0.2 ng/mL, and good selectivity making this platform a good candidate for early stage diagnosis of myocardial infarction.

cardiac output↗

In-situ packaging ultra-uniform 3D hematite nanotubes by polyaniline and their improved gas sensing properties

Highlights: • Ultra-uniform 3D α-Fe{sub 2}O{sub 3} nanotubes were packaged by PANI through the two-stage solution processes. • PANI/α-Fe{sub 2}O{sub 3}-based sensor could detect low concentration of acetone (1 ppm) at lower temperature of 180 °C. • The unique structure of α-Fe{sub 2}O{sub 3} support and its synergetic effect with PANI layers improved the sensor performances. - Abstract: This paper reports the PANI (polyaniline)-packaged three-dimensional (3D) α-Fe{sub 2}O{sub 3} nanotubes P/N heterojunction, which was constructed successfully though a facile hydrothermal reaction without adding any surfactant followed by in-situ chemical polymerization in the liquid phase. The structure and morphology of the products were characterized by means of FESEM, XRD, TEM & HRTEM, TGA and FT-IR. Gas sensing test results found that, the PANI/α-Fe{sub 2}O{sub 3} nanocomposite sensor exhibited obviously higher response, lower working temperature (180 °C), fast response and recovery speeds, good selectivity and excellent stability to acetone gas, indicating its promising application for high-performance acetone sensors. The enhanced gas sensing performances can be attributed to the factors like ultra-uniform 3D nanotube-like structure for α-Fe{sub 2}O{sub 3}, the noticeable advantages of PANI, as well as the construction of heterojunction barrier at their interface. The as-prepared PANI/α-Fe{sub 2}O{sub 3} nanocomposite may be also applied in other areas like photocatalysis, water purification, ion batteries, optical devices, and so on.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

EGS Collab Experiment 2: Continuous Active Source Seismic Monitoring (CASSM)

The dataset contains continuous active-source seismic monitoring (CASSM) data collected during EGS Collab Experiment 2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to investigate enhanced geothermal systems through high-pressure fluid injections at depths of 1200-1500 meters. The seismic monitoring system included 16 three-component piezoelectric accelerometers and 24 hydrophones installed in boreholes around the injection zones, recording signals from piezoelectric seismic sources. Data were acquired using both continuous and triggered recording systems, with sampling rates of up to 100 kHz. The raw data are organized by timestamps and stored in .dat format, with accompanying log files. Calibration certificates for selected accelerometers are provided to aid in correcting sensor responses, though users are advised to consider possible effects of enclosures and installation on sensor performance. Users are strongly advised to consult the accompanying report, which outlines the experimental setup, data acquisition, sensor specifications, and recording systems.

15 GEOTHERMAL ENERGY↗

A Data-driven approach to Core Power distribution reconstruction in a Nuclear Reactor

This report presents the initial development of a data-driven approach for reconstructing the core power distribution in a nuclear reactor (power shape synthesis) using ex-core sensors. Traditional techniques rely on deploying a large number of detectors throughout the reactor core. However, this approach is not feasible for innovative reactor concepts like Advanced Reactors and Microreactors. First, the tight lattice pitch, designed to maximize power density, limits the space available for sensors. Secondly, the harsh operating conditions are not compatible with commercially available detectors. The method proposed in this work integrates high-fidelity modeling with data-driven techniques to accurately reconstruct power distribution across various reactor types, thereby reducing the reliance on in-core sensors. Purdue University Reactor One (PUR-1) was selected as the test case. The CAD model representing the latest configuration of the PUR-1 core was imported into the OpenMC simulation framework, and the model was built. Additionally, the previously developed MCNP6 model was updated. The two models were assessed against the data collected during an experimental campaign conducted in July 2024. Thirty gold foils were placed in three Irradiation Assemblies in PUR-1 core. Using the measured activity of the irradiated foils, the neutron flux at different core locations was estimated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Identifying Urban Pluvial Frequency Flooding Hotspots Using the Topographic Control Index and Remote Sensing Radar Images for Early Warning Systems

Identifying areas that frequently experience post-rainfall ponding is essential for effective flood mitigation and planning. This study integrates Sentinel-1 radar imagery and the Topographic Control Index (TCI) to identify 378 flood-prone urban depressions in Beaumont, Texas. Out of 159 major rainfall events, only six had Sentinel-1 radar imagery acquired within six hours of peak rainfall, and these were used to generate the flood frequency map; the ground-based flood sensor data were used to verify that these selected events corresponded to actual peak rainfall and to validate radar-detected water pixels. Validation results showed 100% precision, 70.87% recall, an F1-score of 82.95%, and 71.32% overall accuracy. Approximately 84% of medium-to-high TCI depressions overlapped with Beaumont’s two-year inundation map, confirming a strong relationship between TCI and observed flooding. A total of 124 depressions retained significant water, and after excluding 25 engineered detention ponds, 99 natural depressions remained flood vulnerable. Among these, 74 depressions with medium or high TCI were identified as the highest-priority nuisance flooding hotspots. The results demonstrate that combining TCI with radar imagery provides a reliable and cost-effective approach for identifying areas prone to frequent urban ponding. This framework supports practical decision-making for drainage improvements, hotspot identification, and early-warning system development in urban flood-prone regions.

Sentinel-1 radar imagery↗

Spacecraft orbit/earth scan derivations, associated APL program, and application to IMP-6

The derivation of a time shared, remote site, demand processed computer program is discussed. The computer program analyzes the effects of selected orbit, attitude, and spacecraft parameters on earth sensor detections of earth. For prelaunch analysis, the program may be used to simulate effects in nominal parameters which are used in preparing attitude data processing programs. After launch, comparison of results from a simulation and from satellite data will produce deviations helpful in isolating problems.

Smith, G. A.↗

Ion beam plume and efflux characterization flight experiment study

A flight experiment and flight experiment package for a shuttle-borne flight test of an 8-cm mercury ion thruster was designed to obtain charged particle and neutral particle material transport data that cannot be obtained in conventional ground based laboratory testing facilities. By the use of both ground and space testing of ion thrusters, the flight worthiness of these ion thrusters, for other spacecraft applications, may be demonstrated. The flight experiment definition for the ion thruster initially defined a broadly ranging series of flight experiments and flight test sensors. From this larger test series and sensor list, an initial flight test configuration was selected with measurements in charged particle material transport, condensible neutral material transport, thruster internal erosion, ion beam neutralization, and ion thrust beam/space plasma electrical equilibration. These measurement areas may all be examined for a seven day shuttle sortie mission and for available test time in the 50 - 100 hour period.

Sellen, J. M., Jr.↗

Development and evaluation of a helicopter-borne water-quality monitoring system

A small, helicopter-borne water-quality monitoring package is being developed by the NASA/EPA using a combination of basic in situ water quality sensors and physical sample collector technology. The package is a lightweight system which can be carried and operated by one person as a passenger in a small helicopter typically available by rental at commercial airports. Real-time measurements are made by suspending the water quality monitoring package with a cable from the hovering helicopter. Designed primarily for use in rapidly assessing hazardous material spills in inland and coastal zone water bodies, the system can survey as many as 20 data stations up to 1.5 kilometers apart in 1 hour. The system provides several channels of sensor data and allows for the addition of future sensors. The system will also collect samples from selected sites with sample collection on command. An EPA Spill Response Team member can easily transport, deploy, and operate the water quality monitoring package to determine the distribution, movement, and concentration of the spilled material in the water body.

Wallace, J. W.↗

Report of subpanel on inter-image matching

Research needs in the area inter-image matching for remote Earth observation systems are defined. Correlation considerations include types of correlation algorithms, preprocessing techniques, limits on subpixed accuracy, relief and atmospheric refraction effects, evaluation of success rate, and evaluation of accuracy. Also recommended are investigations of the interaction of inter-image matching procedures and selection of ground control points for a given sensor; global multisensor control point library feasibility; multiple control point considerations; centralized processing systems; and user systems.

Source record↗

NASA climate data catalog

This document provides a summary of information available in the NASA Climate Data Catalog. The catalog provides scientific users with technical information about selected climate parameter data sets and the associated sensor measurements from which they are derived. It is an integral part of the Pilot Climate Data System (PCDS), an interactive, scientific management system for locating, obtaining, manipulating, and displaying climate research data. The catalog is maintained in a machine readable representation which can easily be accessed via the PCDS. The purposes, format and content of the catalog are discussed. Summarized information is provided about each of the data sets currently described in the catalog. Sample detailed descriptions are included for individual data sets or families of related data sets.

Reph, M. G.↗

Quasi-static shape estimation and control of adaptive truss structures

Methods for estimating the deformation of adaptive truss structures are proposed which employ internal displacement sensors to measure changes in the length of selected truss members. Based on the measured data from the instrumented truss member, the total truss deformation pattern can be estimated through direct interpolation. To verify the validity of the methods presented here, numerical simulations are carried out for simple plane trusses, a beam truss, and a tetrahedral truss.

Kuwao, Fumihiro↗

Comparison of ozone profiles obtained with NIES DIAL and SAGE II measurements

Ozone profiles obtained with the Differential Absorption Lidar (DIAL) system at the National Institute for Environmental Studies (NIES) (Tsukuba, Japan) were compared with data provided by the satellite sensor SAGE II. The SAGE II data were selected based on criteria of spatial and temporal differences between the DIAL and the SAGE II measurements: five degrees in latitude and 15 degrees in longitude, within a latitudinal band from 31 deg to 41 deg N, and within one, three and five days after or before the DIAL measurements. Results show very good agreement for the individual and the zonal-mean profiles. The average mean difference between the DIAL and the SAGE II measurements over the altitudes 15-50 km was about 10 percent.

Nakane, Hideaki↗

Analysis of High Order Difference Methods for Multiscale Complex Compressible Flows

Accurate numerical simulations of complex multiscale compressible viscous flows, especially high speed turbulence combustion and acoustics, demand high order schemes with adaptive numerical dissipation controls. Standard high resolution shock-capturing methods are too dissipative to capture the small scales and/or long-time wave propagations without extreme grid refinements and small time steps. An integrated approach for the control of numerical dissipation in high order schemes with incremental studies was initiated. Here we further refine the analysis on, and improve the understanding of the adaptive numerical dissipation control strategy. Basically, the development of these schemes focuses on high order nondissipative schemes and takes advantage of the progress that has been made for the last 30 years in numerical methods for conservation laws, such as techniques for imposing boundary conditions, techniques for stability at shock waves, and techniques for stable and accurate long-time integration. We concentrate on high order centered spatial discretizations and a fourth-order Runge-Kutta temporal discretizations as the base scheme. Near the bound-aries, the base scheme has stable boundary difference operators. To further enhance stability, the split form of the inviscid flux derivatives is frequently used for smooth flow problems. To enhance nonlinear stability, linear high order numerical dissipations are employed away from discontinuities, and nonlinear filters are employed after each time step in order to suppress spurious oscillations near discontinuities to minimize the smearing of turbulent fluctuations. Although these schemes are built from many components, each of which is well-known, it is not entirely obvious how the different components be best connected. For example, the nonlinear filter could instead have been built into the spatial discretization, so that it would have been activated at each stage in the Runge-Kutta time stepping. We could think of a mechanism that activates the split form of the equations only at some parts of the domain. Another issue is how to define good sensors for determining in which parts of the computational domain a certain feature should be filtered by the appropriate numerical dissipation. For the present study we employ a wavelet technique introduced in as sensors. Here, the method is briefly described with selected numerical experiments.

Sjoegreen, Bjoern↗