Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scanning mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Laser Range and Bearing Finder with No Moving Parts

A proposed laser-based instrument would quickly measure the approximate distance and approximate direction to the closest target within its field of view. The instrument would not contain any moving parts and its mode of operation would not entail scanning over of its field of view. Typically, the instrument would be used to locate a target at a distance on the order of meters to kilometers. The instrument would be best suited for use in an uncluttered setting in which the target is the only or, at worst, the closest object in the vicinity; for example, it could be used aboard an aircraft to detect and track another aircraft flying nearby. The proposed instrument would include a conventional time-of-flight or echo-phase-shift laser range finder, but unlike most other range finders, this one would not generate a narrow cylindrical laser beam; instead, it would generate a conical laser beam spanning the field of view. The instrument would also include a quadrant detector, optics to focus the light returning from the target onto the quadrant detector, and circuitry to synchronize the acquisition of the quadrant-detector output with the arrival of laser light returning from the nearest target. A quadrant detector constantly gathers information from the entire field of view, without scanning; its output is a direct measure of the position of the target-return light spot on the focal plane and is thus a measure of the direction to the target. The instrument should be able to operate at a repetition rate high enough to enable it to track a rapidly moving target. Of course, a target that is not sufficiently reflective could not be located by this instrument. Preferably, retroreflectors should be attached to the target to make it sufficiently reflective.

Bryan, Thomas C.↗

Finding (Or Not) New Gamma-Ray Pulsars with GLAST

Young energetic pulsars will likely be the largest class of Galactic sources observed by GLAST, with many hundreds detected. Many will be unknown as radio pulsars, making pulsation detection dependent on radio and/or x-ray observations or on blind periodicity searches of the gamma-rays. Estimates for the number of pulsars GLAST will detect in blind searches have ranged from tens to many hundreds. I argue that the number will be near the low end of this range, partly due to observations being made in a scanning as opposed to a pointing mode. This paper briefly reviews how blind pulsar searches will be conducted using GLAST, what limits these searches, and how the computations and statistics scale with various parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EMT Model Validation of a 2 MVA PV Inverter Using Transient and Frequency-Domain Hardware Testing: Preprint

This paper presents results and new insights gained from a hardware test campaign on a 2 MVA PV inverter for validating its vendor-supplied EMT model. The test campaign was conducted using a 7 MVA grid simulator and a 2 MW PV emulator. It considered both time-domain transient tests and frequency-domain impedance scan tests. The paper highlights the inadequacy of transient tests in capturing all critical resonance modes of the inverter, and the effectiveness of the frequency scan testing in addressing this problem. The paper shows the frequency scan testing as an effective tool for EMT model validation of IBR units which can highlight inaccuracies in the EMT models that are easy to overlook when model validation is performed using only the time-domain transient tests such as voltage ride-through and phase jump tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Three-dimensional magnetohydrodynamics simulations of counter-helicity spheromak merging in the Swarthmore Spheromak Experiment

Recent counter-helicity spheromak merging experiments in the Swarthmore Spheromak Experiment (SSX) have produced a novel compact torus (CT) with unusual features. These include a persistent antisymmetric toroidal magnetic field profile and a slow, nonlinear emergence of the n = 1 tilt mode. Experimental measurements are inconclusive as to whether this unique CT is a fully merged field-reversed configuration (FRC) with strong toroidal field or a partially merged ''doublet CT'' configuration with both spheromak- and FRC-like characteristics. In this paper, the SSX merging process is studied in detail using three-dimensional resistive MHD simulations from the Hybrid Magnetohydrodynamics (HYM) code. These simulations show that merging plasmas in the SSX parameter regime only partially reconnect, leaving behind a doublet CT rather than an FRC. Through direct comparisons, we show that the magnetic structure in the simulations is highly consistent with the SSX experimental observations. We also find that the n = 1 tilt mode begins as a fast growing linear mode that evolves into a slower-growing nonlinear mode before being detected experimentally. A simulation parameter scan over resistivity, viscosity, and line-tying shows that these parameters can strongly affect the behavior of both the merging process and the tilt mode. In fact, merging in certain parameter regimes is found to produce a toroidal-field-free FRC rather than a doublet CT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-A-12A-08: Computing Longitudinal Material Changes in Bone Metastases Using Dual Energy Computed Tomography

Purpose: This study demonstrates a methodology for tracking changes in metastatic bone disease using trajectories in material basis space in serial dual energy computed tomography (DECT) studies. Methods: This study includes patients with bone metastases from breast cancer that had clinical surveillance CT scans using a General Electric CT750HD in dual energy mode. A radiologist defined regions-of-interested (ROI) for bone metastasis, normal bone, and marrow across the serial DECT scans. Our approach employs a Radon transform to forward-projection the basis images, namely, water and iodine, into sinogram space. This data is then repartitioned into fat/bone and effective density/Z image pairs using assumed energy spectrums for the x-ray energies. This approach both helps remove negative material densities and avoids adding spectrum-hardening artifacts. These new basis data sets were then reconstructed via filtered back-projection to create new material basis pair images. The trajectories of these pairs were then plotted in the new basis space providing a means to both visualize and quantitatively measure changes in the material properties of the tumors. Results: ROI containing radiologist defined metastatic bone disease showed well-defined trajectories in both fat/bone and effective density/Z space. ROI that contained radiologist defined normal bone and marrow did not exhibit any discernible trajectories and were stable from scan to scan. Conclusions: The preliminary results show that changes in material composition and effective density/Z image pairs were seen primarily in metastasis and not in normal tissue. This study indicates that by using routine clinical DECT it may be possible to monitor therapy response of bone metastases because healing or worsening bone metastases change material composition of bone. Additional studies are needed to further validate these results and to test for their correlation with outcome.

60 APPLIED LIFE SCIENCES↗

Understanding process-microstructure-property relationships in laser powder bed fusion of non-spherical Ti-6Al-4V powder

Powder feedstock is a major cost driver in metal additive manufacturing (AM). Replacing the spherical powder with the cost-efficient non-spherical one can reduce the feedstock cost up to 50% and attract more interest to adopt AM in production and new alloy development. Here, for this paper, a comprehensive study was conducted to understand process-microstructure-property relationships in laser powder bed fusion of hydride-dehydride Ti-6Al-4V powder. We demonstrated that variation of laser scan speed had a significant impact on the grain structure, pore evolution and properties compared to laser power. Dynamic X-ray radiography showed that with decreasing scan speed at a constant laser power, a transition from conduction to keyhole mode laser processing occurred, in which a deeper melt pool at lower scan speed intensified texture. In other words, an increase in laser scan speed resulted in formation of the refined prior β grains with shape factor of ~5, lowering the anisotropy. Furthermore, the degree of variant selection was evaluated based on the analyzed texture as a function of laser power and scan speed. With increasing laser scan speed, the dominant α/α boundary type was altered from type 2 to 4 and the degree of variant selection was noticeably decreased. On the other hand, increasing laser power left the morphology of prior β grains, their size, and the dominant α/α boundary (type 4) unchanged, while the texture and anisotropy were intensified, and the degree of variant selection was slightly decreased. Finally, dependency of surface roughness and microhardness were discussed as a function of laser processing parameters.

variant selection↗

Determination of Small Animal Long Bone Properties Using Densitometry

Assessment of bone structural property changes due to loading regimens or pharmacological treatment typically requires destructive mechanical testing and sectioning. Our group has accurately and non-destructively estimated three dimensional cross-sectional areal properties (principal moments of inertia, Imax and Imin, and principal angle, Theta) of human cadaver long bones from pixel-by-pixel analysis of three non-coplanar densitometry scans. Because the scanner beam width is on the order of typical small animal diapbyseal diameters, applying this technique to high-resolution scans of rat long bones necessitates additional processing to minimize errors induced by beam smearing, such as dependence on sample orientation and overestimation of Imax and Imin. We hypothesized that these errors are correctable by digital image processing of the raw scan data. In all cases, four scans, using only the low energy data (Hologic QDR-1000W, small animal mode), are averaged to increase image signal-to-noise ratio. Raw scans are additionally processed by interpolation, deconvolution by a filter derived from scanner beam characteristics, and masking using a variable threshold based on image dynamic range. To assess accuracy, we scanned an aluminum step phantom at 12 orientations over a range of 180 deg about the longitudinal axis, in 15 deg increments. The phantom dimensions (2.5, 3.1, 3.8 mm x 4.4 mm; Imin/Imax: 0.33-0.74) were comparable to the dimensions of a rat femur which was also scanned. Cross-sectional properties were determined at 0.25 mm increments along the length of the phantom and femur. The table shows average error (+/- SD) from theory of Imax, Imin, and Theta) over the 12 orientations, calculated from raw and fully processed phantom images, as well as standard deviations about the mean for the femur scans. Processing of phantom scans increased agreement with theory, indicating improved accuracy. Smaller standard deviations with processing indicate increased precision and repeatability. Standard deviations for the femur are consistent with those of the phantom. We conclude that in conjunction with digital image enhancement, densitometry scans are suitable for non-destructive determination of areal properties of small animal bones of comparable size to our phantom, allowing prediction of Imax and Imin within 2.5% and Theta within a fraction of a degree. This method represents a considerable extension of current methods of analyzing bone tissue distribution in small animal bones.

Breit, Gregory A.↗

Physics design requirements for the National Spherical Torus Experiment liquid lithium divertor

Recent National Spherical Tokamak Experiment (NSTX) high-power divertor experiments have shown significant and recurring benefits of solid lithium coatings on plasma facing components (PFCs) to the performance of divertor plasmas in both L- and H-mode confinement regimes heated by high-power neutral beams. The next step in this work is installation of a liquid lithium divertor (LLD) to achieve density control for inductionless current drive capability (e.g., about a 15 25% ne decrease from present highest non-inductionless fraction discharges which often evolve toward the density limit, ne/nGW 1), to enable ne scan capability ( 2) in the H-mode, to test the ability to operate at significantly lower density (e.g., ne/nGW = 0.25), for future reactor designs based on the Spherical Tokamak, and eventually to investigate high heat-flux power handling (10 MW/m2) with long pulse discharges (>1.5 s). The first step (LLD-1) physics design encompasses the desired plasma requirements, the experimental capabilities and conditions, power handling, radial location, pumping capability, operating temperature, lithium filling, MHD forces, and diagnostics for control and characterization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics Design Requirements for the National Spherical Torus Experiment Liquid Lithium Divertor

Recent NSTX high power divertor experiments have shown significant and recurring benefits of solid lithium coatings on PFC's to the performance of divertor plasmas in both L- and H- mode confinement regimes heated by high-power neutral beams. The next step in this work is installation of a liquid lithium divertor (LLD) to achieve density control for inductionless current drive capability (e.g., about a 15-25% ne decrease from present highest non-inductionless fraction discharges which often evolve toward the density limit, ne/nGW~1), to enable ne scan capability (x2) in the H-mode, to test the ability to operate at significantly lower density for future ST-CTF reactor designs (e.g., ne/nGW = 0.25), and eventually to investigate high heat-flux power handling (10 MW/m2) with longpulse discharges (>1.5s). The first step (LLD-1) physics design encompasses the desired plasma requirements, the experimental capabilities and conditions, power handling, radial location, pumping capability, operating temperature, lithium filling, MHD forces, and diagnostics for control and characterization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of SEM induced current and voltage contrast modes to assess semiconductor reliability

The purpose of the scanning electron microscopy study was to review the failure history of existing integrated circuit technologies to identify predominant failure mechanisms, and to evaluate the feasibility of their detection using SEM application techniques. The study investigated the effects of E-beam irradiation damage and contamination deposition rates; developed the necessary methods for applying the techniques to the detection of latent defects and weaknesses in integrated circuits; and made recommendations for applying the techniques.

Beall, J. R.↗

High-speed imaging upgrade for a standard sample scanning atomic force microscope using small cantilevers

We present an atomic force microscope (AFM) head for optical beam deflection on small cantilevers. Our AFM head is designed to be small in size, easily integrated into a commercial AFM system, and has a modular architecture facilitating exchange of the optical and electronic assemblies. We present two different designs for both the optical beam deflection and the electronic readout systems, and evaluate their performance. Using small cantilevers with our AFM head on an otherwise unmodified commercial AFM system, we are able to take tapping mode images approximately 5–10 times faster compared to the same AFM system using large cantilevers. By using additional scanner turnaround resonance compensation and a controller designed for high-speed AFM imaging, we show tapping mode imaging of lipid bilayers at line scan rates of 100–500 Hz for scan areas of several micrometers in size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics design requirements for the National Spherical Torus Experiment liquid lithium divertor

Recent National Spherical Tokamak Experiment (NSTX) high-power divertor experiments have shown significant and recurring benefits of solid lithium coatings on plasma facing components (PFCs) to the performance of divertor plasmas in both L- and H-mode confinement regimes heated by high-power neutral beams. The next step in this work is installation of a liquid lithium divertor (LLD) to achieve density control for inductionless current drive capability (e.g., about a 15–25% n e decrease from present highest non-inductionless fraction discharges which often evolve toward the density limit, n e /n GW ~ 1), to enable n e scan capability (×2) in the H-mode, to test the ability to operate at significantly lower density (e.g., n e /n GW = 0.25), for future reactor designs based on the Spherical Tokamak, and eventually to investigate high heat-flux power handling (10 MW/m 2 ) with long pulse discharges (>1.5 s). Finally, the first step (LLD-1) physics design encompasses the desired plasma requirements, the experimental capabilities and conditions, power handling, radial location, pumping capability, operating temperature, lithium filling, MHD forces, and diagnostics for control and characterization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvement of scanning radiometer performance by digital reference averaging

Most radiometers utilize a calibration technique in which measurements of a known reference are subtracted from measurements of an unknown source so that common-mode bias errors are cancelled. When a radiometer is scanned over a varying scene, it produces a sequence of outputs, each being proportional to the difference between the reference and the corresponding input. A reference averaging technique is presented that employs a simple digital algorithm which exploits the asymmetry between the time-variable scene inputs and the nominally constant reference input by averaging many reference measurements to decrease the statistical uncertainty in the reference value. This algorithm is, therefore, optimized by an asymmetric chopping sequence in which the scene is viewed for more than one-half of the duty cycle (unlike the analog Dicke technique). Reference averaging algorithms are well within the capabilities of small microprocessors. Although this paper develops the technique for microwave radiometry, it may be beneficial for any system which measures a large number of unknowns relative to a known reference in the presence of slowly varying common-mode errors.

Bremer, J. C.↗

Evaluation of the emission capabilities of Spindt-type field emitting cathodes

The electron emitting capabilities of Spindt-type field emitting cathodes (FEC) are being studied at the Lewis Research Center, NASA. These cathodes, having 5000 emitting points in a 1 mm diameter, have been shown to be capable of emission current densities of 10 A/sq cm and higher. The purposes of this study are to (1) demonstrate that the cathodes can be processed and used in a tube-type configuration, (2) determine whether, at a sufficiently high current density, the cathode can operate in the space charge mode, and (3) evaluate failure mechanisms in this unique type of electron emitter. FEC's have been tested in a diode configuration, by the use of pulse techniques, up to current densities of 6 A/sq cm and anode potentials of 3000 V. Space charge effects have been observed in the range of 5 A/sq cm as an apparent linear increase of cathode current with anode voltage for a constant emitter-gate potential. Failed cathodes were studied by means of scanning electron microscopy and the major failure modes encountered are attributed to gas evolution, followed by arcing, which destroys either individual emitters or a large segment of the cathode area.

Forman, R.↗

Resonant mode effects on rotation braking induced by n = 1 resonant magnetic perturbations in the EAST tokamak

Abstract The spectrum effects on toroidal rotation braking, induced by n = 1 resonant magnetic perturbations (RMPs) in the discharges with q 95 = 4.1 and q 95 = 5.1 , are studied in the EAST tokamak. Here n is the toroidal mode number, RMP spectrum is varied by scanning δ ϕ U L , the phase difference between the upper and lower rows of RMP coils. The toroidal rotation changes periodically with the periodic δ ϕ U L scanning and such an effect is stronger in the discharge with lower q 95 = 4.1 . The spectrum dependence of the neoclassical toroidal viscosity (NTV) torque, modeled by NTVTOK based on the magnetic perturbation obtained from MARS-F calculation, agrees well with that of the experimentally observed braking torques in both discharges. The modeled NTV torque is stronger in the discharge with lower q 95 , which also agrees with the observations. The comparisons between the spectrum dependence of the NTV and magnetic perturbations show that the resonant mode of magnetic perturbations near the plasma edge mainly contribute the NTV torque. These agreements between modeling and experiments highlight the capability of NTV theory in explaining the experimental observation in the EAST tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shaping Effects on Non-Ideal Ballooning Mode

The dependence of shaping effects on the growth rate of collisionless and resistive ballooning mode (CBM/RBM) is numerically researched. Furthermore, that of the drift ballooning modes (DCBM/DRBM) is investigated by taking kinetic effects into account. Resistivity scans of linear growth rates of CBM/RBM and DCBM/DRBM in a circular geometry show that both modes have 3 branches in accordance with decreasing resistivity, fast, resistive and collisionless branch. The last two branches are in the edge relevant resistivity regime and are in the scope of this paper. For CBM/RBM, shaping effect on the growth rate becomes weak with increasing resistivity and the growth rate monotonically increases with decrease of the elongation and increase of the triangularity, on the other hand, the opposite tendency appears on the triangularity for DCBM, namely it weakly decreases with increase of the triangularity. This fact indicates that the inverted D-shaped equilibrium can be unstable against DCBM compared with the D-shaped equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-C-18A-12: Evaluation of the Impact of Body Size and Tube Output Limits in the Optimization of Fast Scanning with High-Pitch Dual Source CT

Purpose: To evaluate the impact of body size and tube power limits in the optimization of fast scanning with high-pitch dual source CT (DSCT). Methods: A previously validated MERCURY phantom, made of polyethylene, with circular cross-section of diameters 16, 23, 30 and 37cm, and connected through tapered sections, was scanned using a second generation DSCT system. The DSCT operates with two independently controlled x-ray tube generators offering up to 200 kW power reserve (100 kW per tube). The entire length of the phantom (42cm) was scanned with two protocols using: A)Standard single-source CT (SSCT) protocol with pitch of 0.8, and B) DSCT protocol with high-pitch values ranging from 1.6 to 3.2 (0.2 steps). All scans used 120 kVp with 150 quality reference mAs using automatic exposure control. Scanner radiation output (CTDIvol) and effective mAs values were extracted retrospectively from DICOM files for each slice. Image noise was recorded. All variables were assessed relative to phantom diameter. Results: With standard-pitch SSCT, the scanner radiation output (and tube-current) were progressively adapted with increasing size, from 6 mGy (120 mAs) up to 15 mGy (270 mAs) from the thinnest (16cm) to the thickest diameter (37 cm), respectively. By comparison, using high-pitch (3.2), the scanner output was bounded at about 8 mGy (140 mAs), independent of phantom diameter. Although relative to standard-pitch, the high-pitch led to lower radiation output for the same scan, the image noise was higher, particularly for larger diameters. To match the radiation output adaptation of standard-pitch, a high-pitch mode of 1.6 was needed, with the advantage of scanning twice as fast. Conclusion: To maximize the benefits of fast scanning with high-pitch DSCT, the body size and tube power limits of the system need to be considered such that a good balance between speed of acquisition and image quality are warranted. JCRG is an employee of Siemens Medical Solutions USA Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗