Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Flat and Level Analysis Tool (FLAT) for real-time automated segmentation and analysis of concrete slab point clouds

In the United States, the flatness and levelness of concrete floors during construction is traditionally specified by a maximum allowable gap under a 3 meter straightedge. However, the straightedge method is inexact and rarely representative of the entire floor since the technician is free to choose any location on the floor to perform the measurement. In cases requiring a higher degree of precision and repeatability, concrete floor flatness and levelness can be measured using the standard test method ASTM E1155. With the recent introduction of advanced surveying instruments such as robotic theodolites and terrestrial laser scanners (TLS), the means now exist to modernize and expedite the measurement of floor flatness and levelness. This paper details the development and demonstration of a digital tool, named the Flat and Level Analysis Tool (FLAT), to automate and expedite the segmentation and analysis of flatness and levelness from dense point cloud data of concrete floor slabs. Segmentation algorithms were developed using unsupervised machine learning to extract the set of points belonging to the concrete floor slab from a full 360 scan of a construction site. After segmentation, automated analysis algorithms report the results according to the standard method. The developed algorithms were demonstrated on a dense point cloud captured from a concrete slab-on-grade at a construction site. Results show that the digital tool can quickly provide estimates for floor flatness and levelness with minimal human involvement with comparable accuracy to manual methods.

Hayes, Nolan↗

Michigan experimental multispectral scanner system

A functional description of a multispectral airborne scanner system that provides spectral bands along a single optical line of sight is reported. The airborne scanner consists of an optical telescope for scanning plane perpendicular to the longitudinal axis of the aircraft and radiation detectors for converting radiation to electrical signals. The system makes a linear transformation of input radiation to voltage recorded on analog magnetic tape.

Hasell, P. G., Jr.↗

L Alpha Photometry of Comet Bennett

Results of scanning Comet Bennett in L alpha from OGO-5 are reported. A plot of the comet isophotes in L alpha is presented. The outer envelope of the comet is approximately the 50-Rayleigh contour.

Dubin, M.↗

Nepheline and sodalite in a barred olivine chondrule from the Allende meteorite

The discovery of nepheline and sodalite in association with glass in a barred olivine chondrule from the Allende C3V meteorite is reported, and the possible origin of the minerals is discussed. Scanning electron microscope/energy dispersive analysis indicates that the major minerals of the chondrule are olivine, bronzite and chromite, with olivine bars separated by glass of nearly pure plagioclase composition. The olivine is observed to have a composition richer in Fe than that predicted from olivine-liquid equilibria, indicating, along with the presence of plagioclase glass and small amounts of subcalcic diopside, the nonequilibrium crystallization of the barred olivine chondrule. The textural features of the chondrule are consistent with a liquid origin for nepheline and sodalite from the chondrule-forming liquid under nonequilibrium conditions.

Lumpkin, G. R.↗

Applications of VAS and TOVS to tropical cyclones

The results of the attempts to use VAS (visible IR spin scan radiometer atmospheric sounder) data for predicting tropical cyclones are reported. VAS, mounted on a GEO platform, has 14 detectors for upwelling radiance. The McIDAS software was, by the 1983 hurricane season, upgraded to providing imagery and mass, motion and moisture patterns using the satellite data, which also permitted determinations of accurate temperature and moisture profiles. Comparisons made between VAS and radiosonde data revealed fairly close agreement of satellite and in-situ conditions during the 1983 season. When combined with data from the Tiros operational vertical sounder (TOVS) to define wind streamlines and predict the path of a hurricane from data fed into numerical models, sufficiently good agreement was obtained to initiate plans to forecast a hurricane trajectory during the 1984 season.

Velden, C. S.↗

Transport Modeling for Metallic Electrode: Semiconducting Nanotube Systems

Recently, current-voltage (I-V) characteristics have been reported by Collins et al. for a system with a scanning tunneling microscope (STM) tip and a carbon nanotube. The STM tip was driven forward into a film of many entangled nanotubes on a substrate, and then was retracted, so that one of nanotubes bridged the STM and the film. I-V characteristics had two different patterns for different heights. One showed large dI/ dV with V greater than 0, small dI/dV with V less than 0, and I = 0 near V = 0 (type-I), while the other showed rectification, i.e., I does not equal 0 only with V less than 0 (type-II), with the tip grounded. We propose a physical mechanism to explain the observed I-V patterns. We consider that the observed characteristics strongly reflected the nature of the tip (metal) - nanotube (semiconductor) contact. The other end of the nanotube was entangled well in the film, and simply provided a good Ohmic contact. We will argue that there are two different contact modes: vacuum gap and touching modes, depending on the presence or absence of a tiny vacuum gap d approx. 0.1 - 0.2 nm at the junction. These modes may be related to physisorption and chemisorption, respectively. Once admitting their existence, it is naturally shown that I-V characteristics are type-I in the vacuum gap mode, and type-II in the touching mode. We argue that the nanotube had to be an n-type semiconductor judging from the I-V characteristics, contrary to often observed p-type in the transistor applications, where p-type is probably due to the oxidation in air or the trapped charges in the silicon dioxide. Additional information is contained in the original extended abstract.

Yamada, Toshishige↗

Bone Loss During Spaceflight: Available Models and Counter-Measures

There is ongoing concern for human health during spaceflights. Of particular interest is the uncoupling of bone remodeling and its resultant effect on calcium metabolism and bone loss. The calculated average loss of bone mineral density (BMD) is approximately 1-1.5% per month of spaceflight. The effect of decreased BMD on associated fractures in astronauts is not known. Currently on the International Space Station (ISS), bone loss is managed through dietary supplements and modifications and resistance exercise regimen. As the duration of space flights increases, a review of the current methods available for the prevention of bone loss is warranted. The goal of this project is to review and summarize recent studies that have focused on maintaining BMD during exposure to microgravity. Interventions were divided into physical (Table 1), nutritional (Table 2), or pharmacologic (Table 3) categories. Physical modalities included resistance exercise, low level vibration, and low intensity pulsed ultrasound. Nutritional interventions included altering protein, salt, and fat intake; and vitamin D supplementation. Pharmacologic interventions included the use of bisphosphonates and beta blockers. Studies reported outcomes based on bone density determined by DXA bone scan, micro-architecture of histology and microCT, and serum and urine markers of bone turnover. The ground analog models utilized to approximate osseous physiology in microgravity included human patients previously paralyzed or subjects confined to bedrest. Ground analog animal models include paralysis, immobilization and ovariectomies. As a result of the extensive research performed there is a multi-modality approach available for the management of BMD during spaceflight that includes resistance training, nutrition and dietary supplements. However, there is a paucity of literature describing a formalized tiered protocol to guide investigators through the progression from animal models to human patient ground analogs to experiments on the ISS. With regards to testing, further evaluation to determine the association between non-invasive tests and fracture during and after spaceflight needs to be performed.

Morris, Jonathan↗

X-Ray Diffraction and Reflectance Spectroscopy of Murchison Powders (CM2) After Thermal Analysis Under Reducing Conditions to Final Temperatures Between 300 and 1300°c

The asteroids Ryugu and Bennu have spectral characteristics in common with CI/CM type carbonaceous chondrites and are target bodies for JAXA’s Hayabusa2 and NASA’s OSIRIS-Rex missions, respectively. Analog studies, based primarily on the Murchison CM2 chondrite, provide a pathway to separate spectral properties resulting space weathering from those inherent to parent-body, mineralogy, chemistry, and processes. Ryugu shares spectral properties with thermally metamorphosed and partly dehydrated CI/CM chondrites. We have undertaken a multidisciplinary study of the thermal decomposition of Murchison powder samples as an analog to metamorphic process that may have occurred on Ryugu. Bulk analyses include thermal And evolved gas analysis, X-ray diffraction (XRD), and VIS-NIR and Mössbauer spectroscopy; micro- to nanoscale analyses included scanning and transmission electron microscopy and electron probe micro analysisWe report here XRD and VIS-NIR analyses of pre- and post-heated Murchison powders, and in a companion paper report results from multiple electron beam techniques.

Morris, R. V.↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105.This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mapping of ion beam induced current changes in FinFETs

We report on progress in ion placement into silicon devices with scanning probealignment. The device is imaged with a scanning force microscope (SFM) and an aligned argon beam (20 keV, 36 keV) is scanned over the transistor surface. Holes in the lever of the SFM tip collimate the argon beam to sizes of 1.6 mu m and 100 nm in diameter. Ion impacts upset the channel current due to formation of positive charges in the oxide areas. The induced changes in the source-drain current are recorded in dependence of the ion beam position in respect to the FinFET. Maps of local areas responding to the ion beam are obtained.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Extending the search for neutrino point sources with IceCube above the horizon

Point source searches with the IceCube neutrino telescope have been restricted to one hemisphere, due to the exclusive selection of upward going events as a way of rejecting the atmospheric muon background. We show that the region above the horizon can be included by suppressing the background through energy-sensitive cuts. This approach improves the sensitivity above PeV energies, previously not accessible for declinations of more than a few degrees below the horizon due to the absorption of neutrinos in Earth. We present results based on data collected with 22 strings of IceCube, extending its field of view and energy reach for point source searches. No significant excess above the atmospheric background is observed in a sky scan and in tests of source candidates. Upper limits are reported, which for the first time cover point sources in the southern sky up to EeV energies.

79 ASTRONOMY AND ASTROPHYSICS↗

Unveiling and Mapping Polymorphs in Fluorite Y2TiO5 Using 4D-STEM and Unsupervised Machine Learning

Y2TiO5 belongs to the Ln2TiO5 (Ln = lanthanide or Y) family of ceramic materials and exhibits a range of desirable material properties such as radiation tolerance, frustrated magnetism, and large dielectric constant. However, understanding the complex crystal structure of Y2TiO5 remains elusive, given that Y2TiO5 can adopt multiple polymorphs such as cubic, orthorhombic, and hexagonal phases within the lattice. In this work, we report a detailed structural analysis of Y2TiO5 using four-dimensional scanning transmission electron microscopy coupled with unsupervised machine learning. The pyrochlore nanodomains, characterized by the ordered arrangement of yttrium cations on the A site of their A2BO5 structure, are present within the matrix of a predominantly fluorite-structured Y2TiO5 along with a third polymorph, the hexagonal phase. The pyrochlore phase is found to form 2 nm boundary regions around hexagonal phase stacking faults, highlighting the potential influence of the hexagonal phase on the occurrence and distribution of the pyrochlore phase. Lastly, we identify a unique pyrochlore phase with asymmetric arrangement of cation ordering along a single planar direction. Our findings provide invaluable insights into the possible mechanisms stabilizing pyrochlore nanodomains within the fluorite lattice of Y2TiO5.

36 MATERIALS SCIENCE↗

Exploiting the Autofluorescent Properties of Photosynthetic Pigments for Analysis of Pigmentation and Morphology in Live Fremyella diplosiphon Cells

Fremyella diplosiphon is a freshwater, filamentous cyanobacterium that exhibits light-dependent regulation of photosynthetic pigment accumulation and cellular and filament morphologies in a well-known process known as complementary chromatic adaptation (CCA). One of the techniques used to investigate the molecular bases of distinct aspects of CCA is confocal laser scanning microscopy (CLSM). CLSM capitalizes on the autofluorescent properties of cyanobacterial phycobiliproteins and chlorophyll a. We employed CLSM to perform spectral scanning analyses of F. diplosiphon strains grown under distinct light conditions. We report optimized utilization of CLSM to elucidate the molecular basis of the photoregulation of pigment accumulation and morphological responses in F. diplosiphon.

fluorescence imaging↗

Nanothermal characterization of amorphous and crystalline phases in chalcogenide thin films with scanning thermal microscopy

The thermal properties of amorphous and crystalline phases in chalcogenide phase change materials (PCM) play a key role in device performance for non-volatile random-access memory. Here, we report the nanothermal morphology of amorphous and crystalline phases in laser pulsed GeTe and Ge2Sb2Te5 thin films by scanning thermal microscopy (SThM). By SThM measurements and quantitative finite element analysis simulations of two film thicknesses, the PCM thermal conductivities and thermal boundary conductances between the PCM and SThM probe are independently estimated for the amorphous and crystalline phase of each stoichiometry.

Bosse, J. L. (ORCID:000000032320245X)↗

Search for near-Earth asteroids with the spacewatch camera

The Spacewatch Program began as an engineering development of the discovery of near-earth asteroids and comets, with the firs observations starting in 1983, using an RCA charge coupled device (CCD) that has 320 x 512 pixels. Extensive software was written to scan the sky and learn how to do astrometry for precise orbits of newly discovered objects. The merit of the concept was proven, with many observations reported and comets recovered. The precision of astrometric observations for comets and asteroids was improved. For efficient scanning and discovery of new objects, a Tektronix 2048 x 2048 CCD was obtained and is now permanently on the Spacewatch Telescope. Other aspects of the Spacewatch Program are briefly discussed.

Gehrels, T.↗

Corrected Moments in Antenna Coordinates (CMAC) Technical Report

Various corrections are needed in order to extract the best value of the measurements from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility’s scanning precipitation radars. The Corrected Moments in Antenna Coordinates (CMAC) Value-Added Product provides an application chain for providing radar moments that are corrected for artifacts such as aliasing, attenuation, multi-trip echoes, and beam blockage. This technical report provides details on the entire process of correcting the ARM scanning precipitation radar data using CMAC. CMAC has been used at multiple ARM sites and ARM Mobile Facility deployments including the Tracking Aerosol Convection Interactions Experiment (TRACER), Cloud, Aerosol, and Complex Terrain Interactions (CACTI), and the Surface Atmosphere Integrated Laboratory (SAIL).

54 ENVIRONMENTAL SCIENCES↗

Real-time monitoring of calcification process by Sporosarcina pasteurii biofilm

Sporosarcina pasteurii is known to produce calcite or biocement in the presence of urea and Ca 2+ . Herein, we report the use of novel ultramicrosensors such as pH, Ca 2+ , and redox sensors, along with a scanning electrochemical microscope (SECM), to monitor a real-time, bacteria-mediated urea hydrolysis process and subsequent changes in morphology due to CaCO 3 precipitation. We report that the surface pH of a live biofilm changed rapidly from 7.4 to 9.2 within 2 min, whereas similar fast depletion (10 min) of Ca 2+ was observed from 85 mM to 10 mM in the presence of a high urea (10 g L -1 ) brine solution at 23 °C. Both the pH and the Ca 2+ concentration profiles were extended up to 600 μm from the biofilm surface, whereas the bulk chemical composition of the brine solution remained constant over the entire 4 h of SECM experiments. In addition, we observed a change in biofilm surface morphology and an increase in overall biofilm height of 50 μm after 4 h of precipitation. Electron microscopy confirmed the changes in surface morphology and formation of CaCO 3 crystals. Development of the Ca 2+ profile took 10 min, whereas that of the pH profile took 2 min. This finding indicates that the initial urea hydrolysis process is fast and limited by urease or number of bacteria, whereas later CaCO 3 formation and growth of crystals is a slow chemical process. The ultramicrosensors and approaches employed here are capable of accurately characterizing bioremediation on temporal and spatial scales pertinent to the microbial communities and the processes they mediate.

59 BASIC BIOLOGICAL SCIENCES↗

CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D{sub L}(0) and its rise-to-the-equilibrium curve H(L) = D{sub L}(0)/D{sub eq} from computed tomography (CT) scanning, where D{sub eq} is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessed H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm{sup 3} thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E{sub in}/E or E{sub out}/E) on the phantom central and peripheral axes, where E = LD{sub eq} was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose ratios changed with beam aperture and phantom axis but were insensitive to tube voltage. H(L) was insensitive to tube voltage and CT scanner model. As phantom diameter increased from 6 to 55 cm, E{sub in}/E generally decreased but asymptotically approached constant levels on the peripheral axes of large phantoms. The curve of E{sub in}/E versus scan length was almost identical to that of H(L). Similarly, E{sub out}/E increased with scan length and asymptotically approached the equilibrium for large scan lengths. E{sub out}/D{sub eq} was much less than the equilibrium length L{sub eq} where H(L) = 0.98, even with scan lengths much larger than L{sub eq}. Conclusions: The polyethylene phantom designed by ICRU Report No. 87 Committee and AAPM Task Group 200 is adequately long for assessing the midpoint dose and its equilibration in CT scanning. The short-to-long phantom dose ratios and the H(L) data provided in this paper allow easy evaluations of the midpoint dose, longitudinal dose distribution, and energy absorption in polyethylene phantoms. The results of dose equilibration and energy absorption presented herein may be insightful for the clinical CT scans with various subject sizes and scan lengths.

07 ISOTOPE AND RADIATION SOURCES↗