Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Compounds in airborne particulates - Salts and hydrocarbons

Concentrations of 10 polycyclic aromatic hydrocarbons (PAH), the aliphatics as a group, sulfate, nitrate, fluoride, acidity, and carbon in the airborne particulate matter were measured at 16 sites in Cleveland, OH over a 1-year period during 1971 and 1972. Analytical methods used included gas chromatography, colorimetry, and combustion techniques. Uncertainties in the concentrations associated with the sampling procedures, and the analytical methods are evaluated. The data are discussed relative to other studies and source origins. High concentrations downwind of coke ovens for 3,4 benzopyrene are discussed. Hydrocarbon correlation studies indicated no significant relations among compounds studied.

King, R. B.↗

Report of the Workshop for Life Detection in Samples from Mars

The question of whether there is or was life on Mars has been one of the most pivotal since Schiaparellis' telescopic observations of the red planet. With the advent of the space age, this question can be addressed directly by exploring the surface of Mars and by bringing samples to Earth for analysis. The latter, however, is not free of problems. Life can be found virtually everywhere on Earth. Hence the potential for contaminating the Mars samples and compromising their scientific integrity is not negligible. Conversely, if life is present in samples from Mars, this may represent a potential source of extraterrestrial biological contamination for Earth. A range of measures and policies, collectively termed 'planetary protection', are employed to minimise risks and thereby prevent undesirable consequences for the terrestrial biosphere. This report documents discussions and conclusions from a workshop held in 2012, which followed a public conference focused on current capabilities for performing life-detection studies on Mars samples. The workshop focused on the evaluation of Mars samples that would maximise scientific productivity and inform decision making in the context of planetary protection. Workshop participants developed a strong consensus that the same measurements could be employed to effectively inform both science and planetary protection, when applied in the context of two competing hypotheses: 1) that there is no detectable life in the samples; or 2) that there is martian life in the samples. Participants then outlined a sequence for sample processing and defined analytical methods that would test these hypotheses. They also identified critical developments to enable the analysis of samples from Mars.

Life Detection↗

Developing a Genetic Variant Calling Pipeline for Quantifying the Complex Mutagenic Load Accumulated in BioNutrients-1 Production Pack Samples

Microorganisms hold great promise for on demand production of labile nutrients and pharmaceuticals as well recycling and in situ resource utilization. The utilization of microorganisms for such tasks on space missions is hindered by the limited data on how microbes respond to spaceflight. For example, the genetic stability of microorganisms, and the genomic engineered traits added to deliver desired functions, over long-term storage in the spacecraft environment is poorly understood. The BioNutrients-1 (BN-1) mission conducted a 5-year study of desiccated storage in Low Earth Orbit (LEO) to evaluate the suitability of eight synthetic biology chassis organisms for long-duration space missions. We are employing high-depth, whole genome sequencing (WGS) to determine the mutagenic load that accumulated during long-term storage. Mutation analysis pipelines are well established for homogenous culture grown from a single colony, but the mutational landscape of the BN-1 samples present a unique analysis challenge, as every cell in the BN-1 samples had a unique genetic journey of DNA damage and repair. Consequently, sequence variants are expected at low allele frequency within samples. To address this genetic complexity, we apply two distinct computational approaches to identify mutations in pre-existing WGS data collected from populations of Chlamydomonas reinhardtii that were exposed to UV mutagenesis and growth in LEO. For reference genome free mutation detection, we utilized DiscoSNP++, which is a de Bruijn graph approach. For reference genome-based mutation detection we utilize GATK for Microbes, which is a Bayesian probabilistic approach. We will benchmark these approaches against the mutations originally identified using CRISP, a method optimized for pooled samples. Ultimately, quantifying the mutation load imposed by storage or growth on the ISS will help identify chassis organisms with both high levels of genome stability and viability, which are desirable traits for implementation of bioproduction in long-duration missions.

SNP↗

Tracer techniques for urine volume determination and urine collection and sampling back-up system

The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

Ramirez, R. V.↗

Derivation of Effective Properties Based on Porous Scale Simulations Using Filtering Techniques

This study presents a method for derivation of effective properties at the interface and in-depth of porous materials. The method defines a Representative Elementary Volume (REV) and applies filtering techniques to computer effective properties such as porosity and flow quantities, such as velocity and pressure. The script, developed to process the data was tested on the VTK type files that contain the mesh information and the flow solution. The method allows to choose between two types of filters, such as cellular and top-hat and define the size of the REV and number of samples along the domain. Extraction of the REV from the domain is performed to exact boundaries requested for the user. This is done using a triangulation technique and cutting through the cells to comply to the requested boundaries of the volume. The method can be applied to both structured and unstructured meshes. Filtering the material porosity and flow quantities involves integration of the numerical data. The algorithm provides three integration methods, such as Riemann sum, Monte Carlo and Quadrature rule to perform the integration. The Monte-Carlo technique permits the use of either uniform or linearly spaced distribution of points. The Quadrature rule is currently applicable to tetrahedral element types. The Monte Carlo and Quadrature rule methods require interpolation of the flow quantities at the sample points. For interpolation, two methods were tested and are readily available, Gaussian interpolation and re-sampling. It has been shown that re-sampling method has better consistency and acceptable accuracy in interpolation of the data. The algorithm was written in Python language and uses a number of modules. The major module besides numpy is PyVista. It is used to process the computational domain, clip the REV and interpolate the data. Quadrature rule integration was performed using a quadpy module. ParaView software was used externally to convert the flow solution to the VTK (or more specifically VTU) format. Integration of ParaView in the same environment with PyVista encountered problems and could not be implemented in this work. The developed algorithm is expected to be applicable to unstructured meshes and more complex porous structures as soon as the data can be passed in VTK type format. With the report is provided Python script for filtering the solution and a Matlab script for simple generation and processing of 2-D and 3-D porous channel geometries. The two scripts don't communicate.

Alexsander Zibitsker↗

Combinatorial Reasoning: Selecting Reasons in Generative AI Pipelines via Combinatorial Optimization

Recent Large Language Models (LLMs) have demonstrated impressive capabilities at tasks that require human intelligence and are a significant step towards human-like artificial intelligence (AI). Yet the performance of LLMs at reasoning tasks have been subpar and the reasoning capability of LLMs is a matter of significant debate. While it has been shown that the choice of the prompting technique to the LLM can alter its performance on a multitude of tasks, including reasoning, the best performing techniques require human-made prompts with the knowledge of the tasks at hand. We introduce a framework for what we call Combinatorial Reasoning (CR), a fully-automated prompting method, where reasons are sampled from an LLM pipeline and mapped into a Quadratic Unconstrained Binary Optimization (QUBO) problem. The framework investigates whether QUBO solutions can be profitably used to select a useful subset of the reasons to construct a Chain-of-Thought style prompt. We explore the acceleration of CR with specialized solvers. We also investigate the performance of simpler zero-shot strategies such as linear majority rule or random selection of reasons. Our preliminary study indicates that coupling a combinatorial solver to generative AI pipelines is an interesting avenue for AI reasoning and elucidates design principles for future CR methods.

combinatorial reasoning↗

X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass. These scans show the clast to be approx.4.5 g, however (assuming a density of approx.3.5 g/cc). This is large enough for detailed studies including multiple geo-chronometers. This basalt clast is of particular interest as it is the largest Apollo 16 basalt, and it is the only mid-TiO2 basalt in the Apollo sample suite. By identifying the location of interesting clasts or grains within a sample, we will be able to make more informed decisions about where to cut a sample in order to best expose clasts of interest for future study. Moreover, knowing the location of internal defects (e.g., fractures) will allow more precise chipping and extraction of clasts or grains. By combining micro-CT scans with compositional techniques like micro x-ray fluorescence (particularly on sawn slabs), we will be able to provide even more comprehensive information to scientists trying to best select samples that fit their scientific needs.

Ziegler, R. A.↗

Monitoring occupational exposure to cancer chemotherapy drugs

Reports of the health effects of handling cytotoxic drugs and compliance with guidelines for handling these agents are briefly reviewed, and studies using analytical and biological methods of detecting exposure are evaluated. There is little conclusive evidence of detrimental health effects from occupational exposure to cytotoxic drugs. Work practices have improved since the issuance of guidelines for handling these drugs, but compliance with the recommended practices is still inadequate. Of 64 reports published since 1979 on studies of workers' exposure to these drugs, 53 involved studies of changes in cellular or molecular endpoints (biological markers) and 12 described chemical analyses of drugs or their metabolites in urine (2 involved both, and 2 reported the same study). The primary biological markers used were urine mutagenicity, sister chromatid exchange, and chromosomal aberrations; other studies involved formation of micronuclei and measurements of urinary thioethers. The studies had small sample sizes, and the methods were qualitative, nonspecific, subject to many confounders, and possibly not sensitive enough to detect most occupational exposures. Since none of the currently available biological and analytical methods is sufficiently reliable or reproducible for routine monitoring of exposure in the workplace, further studies using these methods are not recommended; efforts should focus instead on wide-spread implementation of improved practices for handling cytotoxic drugs.

Review, Academic↗

Design and construction of a tensile tester for the testing of simple composites

The following is a design for a tensile tester which will be used to test the tensile strength and anisotropic properties of simple composites. These simple composites are suspected to be anisotropic primarily in a single plane. When the composites undergo a tensile force, they will undergo deformation, causing movement either to the left or right. The composites are suspect due to their method of construction. Each sample has a single layer of unidirectional continuous fibers embedded in a rubbery resin. It has been well established that a serious limitation of unidirectional fiber composites is the very large in-plane anisotropy. The design presented here incorporates a single degree of freedom such that distortion (to the left or right) due to anisotropic tendencies may be measured. The device will spend the vast majority of its time in an undergraduate materials lab. As a result, ease of use and durability are valued more highly than research grade accuracy. Additional concerns focus on the fact that this machine will be built as a student project. Issues which are dealt with during this design include: specimen configuration or shape; a method of applying consistent, linear tension force; a method of gripping specimen without affecting its overall properties; a method of collecting data; repeatability of data; ease of use; ease of construction; and cost. After the device has been constructed, it will be used to test the simple composites which were fabricated in house. A comparison will be made between composites manufactured using aluminum screening as the strengthening fibers and those manufactured using fiberglass screening.

Borst, Mark A.↗

Blood Collection

The method that is used for the collection, storage and real-time analysis of blood and other bodily fluids has been licensed to DBCD, Inc. by NASA. The result of this patent licensing agreement has been the development of a commercial product that can provide serum or plasma from whole blood volumes of 20 microliters to 4 milliliters. The device has a fibrous filter with a pore size of less than about 3 microns, and is coated with a mixture of mannitol and plasma fraction protein. The coating causes the cellular fraction to be trapped by the small pores, leaving the cellular fraction intact on the fibrous filter while the acellular fraction passes through the filter for collection in unaltered form from the serum sample collection chamber. The method used by this product is useful to NASA for blood analysis on manned space missions.

Source record↗

Synthetic seawater as stress-corrosion test medium

Seawater minimizes pitting corrosion of aluminum-alloy test samples. Of three corrosion-inhibiting methods evaluated using (a) chromate inhibitors in saltwater, (b) surface treating sample via anodizing or alodine treatment, and (c) synthetic seawater, synthetic seawater was most effective test medium, since it is more uniform than fresh seawater.

Humphries, T. S.↗

FDDO and DSMC analyses of rarefied gas flow through 2D nozzles

Two different approaches, the finite-difference method coupled with the discrete-ordinate method (FDDO), and the direct-simulation Monte Carlo (DSMC) method, are used in the analysis of the flow of a rarefied gas expanding through a two-dimensional nozzle and into a surrounding low-density environment. In the FDDO analysis, by employing the discrete-ordinate method, the Boltzmann equation simplified by a model collision integral is transformed to a set of partial differential equations which are continuous in physical space but are point functions in molecular velocity space. The set of partial differential equations are solved by means of a finite-difference approximation. In the DSMC analysis, the variable hard sphere model is used as a molecular model and the no time counter method is employed as a collision sampling technique. The results of both the FDDO and the DSMC methods show good agreement. The FDDO method requires less computational effort than the DSMC method by factors of 10 to 40 in CPU time, depending on the degree of rarefaction.

Chung, Chan-Hong↗

Space Algae-2: Preflight Testing for A Long-Duration, Multi-Omics Analysis of Arthrospira Platensis

The cyanobacteria Arthrospira platensis NIES-39, commonly known as spirulina, could provide a fresh supply of nutrients for crew on long-duration spaceflight missions. Spirulina is a readily digestible food that is high in protein with all essential amino acids as well as significant levels of B vitamins, antioxidants, and anti-inflammatory metabolites. Spaceflight has multiple abiotic stressors such as increased ionizing radiation and microgravity, which causes a lack of convective mixing. These environmental conditions may impact productivity, nutritional composition, and in long-duration propagation, spaceflight stress may impact the genetic stability of spirulina cultures. We are developing an International Space Station experiment to continuously culture A. platensis for six months. Multi-omics profiling will be used to monitor for changes in the genome, transcriptome, proteome, and metabolome to determine if A. platensis is a suitable nutritional supplement on long-duration missions. During preflight testing we developed a protocol for inoculated liquid cultures to survive a 10-week storage period prior to photo-incubation. The bioreactor bag, temperature, and lighting conditions that support a 14-day growth cycle between passages were also determined. Media testing identified minimal salts supporting robust growth that can be stored in liquid or dry form. A simple filtration method was developed to dewater cultures and harvest biomass for frozen sample return. We optimized a cryopreservation method to enable return of live cells for isolation of individual A. platensis clones. The concept of operations for Space Algae-2 developed from these test results as well as progress on multi-omics analysis methods will be presented.

Algae↗

Space Algae-2: Preflight Testing for A Long-Duration, Multi-Omics Analysis of Arthrospira Platensis

The cyanobacteria Arthrospira platensis NIES-39, commonly known as spirulina, could provide a fresh supply of nutrients for crew on long-duration spaceflight missions. Spirulina is a readily digestible food that is high in protein with all essential amino acids as well as significant levels of B vitamins, antioxidants, and anti-inflammatory metabolites. Spaceflight has multiple abiotic stressors such as increased ionizing radiation and microgravity, which causes a lack of convective mixing. These environmental conditions may impact productivity, nutritional composition, and in long-duration propagation, spaceflight stress may impact the genetic stability of spirulina cultures. We are developing an International Space Station experiment to continuously culture A. platensis for six months. Multi-omics profiling will be used to monitor for changes in the genome, transcriptome, proteome, and metabolome to determine if A. platensis is a suitable nutritional supplement on long-duration missions. During preflight testing we developed a protocol for inoculated liquid cultures to survive a 10-week storage period prior to photo-incubation. The bioreactor bag, temperature, and lighting conditions that support a 14-day growth cycle between passages were also determined. Media testing identified minimal salts supporting robust growth that can be stored in liquid or dry form. A simple filtration method was developed to dewater cultures and harvest biomass for frozen sample return. We optimized a cryopreservation method to enable return of live cells for isolation of individual A. platensis clones. The concept of operations for Space Algae-2 developed from these test results as well as progress on multi-omics analysis methods will be presented.

Algae↗

Determination of micro amounts of iron, aluminum, and alkaline earth metals in silicon carbide

A colorimetric method for analysis of micro components in silicon carbide used as the raw material for varistors is described. The microcomponents analyzed included iron soluble in hydrochloric acid, iron, aluminum, calcium and magnesium. Samples were analyzed by the method, and the results for iron and aluminum agreed well with the N.B.S. standard values and the values obtained by the other company. The method can therefore be applied to the analysis of actual samples.

Hirata, H.↗

Techniques for improving the Si-SiO2 interface characterization

The two techniques which have provided most of the information on interface states in MIS-C (metal-insulator-semiconductor-capacitor) structures are the 'quasi-static method' and the 'conductance method'. Sher et al. (1979) and Su et al. (1980) have suggested a number of improvements concerning these methods. The present investigation has the objective to extend the earlier results and to offer a new tentative interpretation of the data. A critical review is conducted of the data collection and reduction techniques for the quasi-static method, taking into account the sample, the quasi-static capacitance, and the surface potential. In connection with a discussion of the conductance method, attention is given to parallel conductance and capacitance measurements, interface-state densities, time constants, and measurements on a (110) surface orientation.

Sher, A.↗

Search for Fluid Inclusions in a Carbonaceous Chondrite Using a New X-Ray Micro-Tomography Technique Combined with FIB Sampling

Early solar system aqueous fluids are preserved in some H chondrites as aqueous fluid inclusions in halite (e.g., [1]). Although potential fluid inclusions are also expected in carbonaceous chondrites [2], they have not been surely confirmed. In order to search for these fluid inclusions, we have developped a new X-ray micro-tomography technique combined with FIB sampling and applied this techniqu to a carbanaceous chondrite. Experimental: A polished thin section of Sutter's Mill meteorite (CM) was observed with an optical microscope and FE-SEM (JEOL 7001F) for chosing mineral grains of carbonates (mainly calcite) and sulfides (FeS and ZnS) 20-50 microns in typical size, which may have aqueous fluid inclusions. Then, a "house" similar to a cube with a roof (20-30 microns in size) is sampled from the mineral grain by using FIB (FEI Quanta 200 3DS). Then, the house was atached to a thin W-needle by FIB and imaged by a SR-based imaging microtomography system with a Fresnel zone plate at beamline BL47XU, SPring-8, Japan. One sample was imaged at two X-ray energies, 7 and 8 keV, to identify mineral phases (dual-enegy microtomography: [3]). The size of voxel (pixel in 3D) was 50-80 nm, which gave the effective spatial resolution of approx. 200 nm. A terrestrial quartz sample with an aqueous fluid inclusion with a bubble was also examined as a test sample by the same method. Results and discussion: A fluid inclusion of 5-8 microns in quartz was clearly identified in a CT image. A bubble of approx. 4 microns was also identified as refraction contrast although the X-ray absorption difference between fluid and bubble is small. Volumes of the fluid and bubble were obtained from the 3D CT images. Fourteen grains of calcite, two grains of iron sulfide and one grain of (Zn,Fe)S were examined. Ten calcite, one iron sulfide and one (Zn,Fe)S grains have inclusions >1 micron in size (the maximum: approx. 5 microns). The shapes are spherical or irregular. Tiny inclusions (<1 micron) are also present in all the grains examined. These results show that mineral grains have more inclusions than expected from 2D observations. The X-ray absorption of the inclusions shows that they are not solid inclusions. No bubbles were observed inside, indicating that we cannot determine whether they are really aqueous fluids or merely voids. One calcite grain has an inclusion approx. 2 microns in size, which seems to have a bubble and a tiny solid daughter crystal inside (three-phase inclusion). As we know the exact 3D position of the inclusion, we will anlyze the inclusion by SIMS after freezing the sample as has been done for a halite sample [3]. The present technique is useful for finding small inclusions not only in carbonaceous chondrites but also for terrestrial materials.

Tsuchiyama, A.↗

Parabolized Navier-Stokes methods for hypersonic flows

A representative sampling of the techniques used in the integration of the Parabolized Navier-Stokes (PNS) equations is presented. Special atention is given to recent algorithms developed specifically for application to high speed flows, characterized by the presence of strong embedded shock waves and real gas effects. It is shown that PNS solvers are being used in the analysis of sonic boom signatures. Methods for modeling physical effects are discussed, including an overview of commonly used turbulence models and a more detailed discussion of techniques for including equilibrium and finite rate real gas effects.

Lawrence, Scott L.↗