Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

ExINP NSA Ice Nucleating Particle Concentrations

This data set comprises cumulative ambient ice-nucleating particle (INP) concentrations measured at the National Oceanic and Atmospheric Administration's (NOAA’s) Barrow Atmospheric Baseline Observatory (71.3230° N, 156.6114° W, “BRW” hereafter), next to the Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) site and ~ 6 km northeast of the town of Utqiaġvik. Our INP abundance data were generated using a combination of online instrument, the Portable Ice Nucleation Experiment chamber ver. 3 (PINE-03), and an offline cold stage, the West Texas Cryogenic Refrigerator Applied to Freezing Test system (WT-CRAFT). Our online INP data are all from the Examining the Ice-Nucleating Particles from NSA (ExINP-NSA) campaign conducted from October 19, 2021 to May 24, 2024. The offline INP concentration analysis was performed at West Texas A&M University for aerosol particle samples collected on polycarbonate filters (with 0.2-micron diameter pores). The PINE-03 measurements, as well as sampling activities for offline INP measurements, were conducted using the BRW site. An inset laminar sampling stack was mounted to the instrument platform, allowing PINE-03 to intake particle-laden air. For most of the campaign period, the semi-autonomous PINE-03 chamber was remotely controlled from West Texas A&M University using the LabView interface through the BeyondTrust remote-access console. PINE-03 was set to conduct an immersion freezing expansion experiment (i.e., simulated adiabatic cooling along with RHw at or above 100%). Except during the scheduled maintenance periods, the time resolution of each expansion experiment was approximately 12 minutes. PINE-03 continuously measured INP concentrations during the entire campaign without any substantial breaks. For most of the campaign period, PINE scanned its set-point vessel air temperatures from -14 °C to -31 °C and back to -14 °C about every 120 minutes.

54 ENVIRONMENTAL SCIENCES↗

ExINP NSA Ice Nucleating Particle Concentrations

This data set comprises cumulative ambient ice-nucleating particle (INP) concentrations measured at the National Oceanic and Atmospheric Administration's (NOAA’s) Barrow Atmospheric Baseline Observatory (71.3230° N, 156.6114° W, “BRW” hereafter), next to the Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) site and ~ 6 km northeast of the town of Utqiaġvik. Our INP abundance data were generated using a combination of online instrument, the Portable Ice Nucleation Experiment chamber ver. 3 (PINE-03), and an offline cold stage, the West Texas Cryogenic Refrigerator Applied to Freezing Test system (WT-CRAFT). Our online INP data are all from the Examining the Ice-Nucleating Particles from NSA (ExINP-NSA) campaign conducted from October 19, 2021 to May 24, 2024. The offline INP concentration analysis was performed at West Texas A&M University for aerosol particle samples collected on polycarbonate filters (with 0.2-micron diameter pores). The PINE-03 measurements, as well as sampling activities for offline INP measurements, were conducted using the BRW site. An inset laminar sampling stack was mounted to the instrument platform, allowing PINE-03 to intake particle-laden air. For most of the campaign period, the semi-autonomous PINE-03 chamber was remotely controlled from West Texas A&M University using the LabView interface through the BeyondTrust remote-access console. PINE-03 was set to conduct an immersion freezing expansion experiment (i.e., simulated adiabatic cooling along with RHw at or above 100%). Except during the scheduled maintenance periods, the time resolution of each expansion experiment was approximately 12 minutes. PINE-03 continuously measured INP concentrations during the entire campaign without any substantial breaks. For most of the campaign period, PINE scanned its set-point vessel air temperatures from -14 °C to -31 °C and back to -14 °C about every 120 minutes.

54 ENVIRONMENTAL SCIENCES↗

DOE Cold Climate Heat Pump Challenge: Development, Metrics, and Early Field Observations

Space heating in residential buildings is a major contributor of Greenhouse Gas (GHG) emissions in the United States. New, advanced electric heat pumps are poised to provide a low carbon alternative to traditional fossil-based heating, especially in colder climates. Widespread deployment of cold climate heat pumps could help address the significant portion of building emissions and primary energy used in American households, but these gains will require broader acceptance from consumers and decision makers. As part of the “Energy, Emissions, and Equity” (E3) initiative, the U.S. Department of Energy launched the Cold Climate Heat Pump Challenge (CCHP) in 2021 to accelerate the deployment of the next generation of air source heat pumps. The Challenge is currently focused on residential, centrally ducted, electric heat pumps, with a nominal cooling capacity greater than or equal to 24,000 Btu/h (2 tons) and less than or equal to 65,000 Btu/h (5 tons). The Challenge specifications represent a best-in-class heat pump product that provides high-efficiency heating performance in cold climates, employs environmentally friendly low-Global Warming Potential (GWP) refrigerants, and is designed to be grid interactive. Spearheaded by DOE in partnership with the US Environmental Protection Agency (EPA) and Natural Resources Canada (NRCan), the CCHP Challenge brings together numerous major heat pump manufacturers and key stakeholders including utilities and state agencies across the country. In addition to performance testing in a laboratory environment, a key component of this research is evaluating the in-field performance of the prototype heat pumps developed as part of the Challenge. This paper will discuss the development of the CCHP Challenge, key performance specifications, and the energy and non-energy metrics that will be evaluated through the field study. The types of data that are being collected from the units installed in homes across North America as part of the field validation will be described, including details about the sensors and data acquisition system. Data cleaning and analysis methodologies will be discussed, along with early observations from the winter 2022-2023, spring and summer performance periods, and an assessment of non-energy metrics through pre- and post-installation homeowner surveys. Challenges uncovered and lessons learned throughout the process will also be discussed. Finally, the paper will discuss next steps for the second winter assessment period, areas needing additional research, and potential applications of the data collected and analyzed through this work.

Mendon, Vrushali V.↗

Design and Fabrication of the Mu2e Cryogenic Distribution System

The muon-to-electron conversion (Mu2e) experiment at Fermilab will be used to search for the charged lepton flavor-violating conversion of muons to electrons in the field of an atomic nucleus. The Mu2e experiment is currently in the design and construction stage and is expected to begin operations in 2022. The Mu2e experiment uses four large superconducting solenoid magnets including a Production Solenoid (PS), an Upstream and Downstream Transport Solenoid (TSu and TSd) and a Detector Solenoid (DS). This paper will focus on the cryogenic distribution system for these four solenoid magnets. Liquid helium will be supplied from two re-purposed Tevatron satellite refrigerators. A large cryogenic distribution box (DB) is located in the Mu2e building to distribute the required cryogens to each of the four solenoid magnets. Each solenoid magnet will have a dedicated transfer line and cryogenic feed box (FB). The solenoid magnets each require two liquid helium circuits and two liquid nitrogen circuits. The most unique feature about this cryogenic system is that the assemblies for the start of the superconducting portion of the power leads are mounted in feed boxes that are in the range of 23 m to 31 m away from the solenoid magnets. The cryogenic feed boxes are located remotely to provide protection from radiation damage and high magnetic fields. The power leads are NbTi superconducting cable stabilized with high conductivity aluminum. The 6061-T6 aluminum grade was selected for the transfer line piping so that the piping would thermally contract at the same rate as the power lead. A major concern for this transfer line is that a small helium leak could create an electric discharge arc due to the Paschen effect. This paper includes a description of the design features and testing done to ensure that the power leads are protected from the Paschen effect while still being adequately cooled to liquid helium temperatures.

43 PARTICLE ACCELERATORS↗

Resilient buildings for fire-adapted landscapes: EE and flexible loads integrated with solar and storage microgrids

Energy efficiency (EE) and flexible loads can be part of a resilient buildings packagewhen they are combined with solar and storage in a clean energy microgrid to reduce the carbonfootprint of buildings and enable resilience to extreme events. Recent large wildfires and an emerging understanding of the fire-adapted landscapes in the American West underscore the urgency of work towards scaling and commercializing these systems. For example, a recent power shutoff in Northern California (October 9-12, 2019) resulted in 738k customers disconnected at the peak of the outage and is emblematic of challenges to come. Our paper reports on insights from a clean energy microgrid deployment pilot that integrates a 50 kWAC PV array, a 109 kW / 174 kWh battery system, switchgear to safely isolate from the regional power system, and communicating controllers for HVAC and refrigeration. The project will be commissioned in May 2020 and is sited at a critical infrastructure site in rural Northern California – in this case a gasoline station with convenience store. Our experience and results shed light on capabilities of integrated microgrids to provide value to customers during blue sky conditions and resilience during black sky days with high fire risk, and what opportunities and barriers exist for scaling these integrated microgrid systems in the near term. We use a simulation model to estimate how EE and flexibility can extend the run time of solar and storage, improving the reliability of power at critical sites.

Alstone, Peter↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

Bahar, Bamdad↗

SEASONAL PERFORMANCE SIMULATION OF A GAS-FIRED CHEMISORPTION HEAT PUMP FOR RESIDENTIAL HEATING IN COLD CLIMATE

The gas-fired chemisorption heat pump (CSHP) is a promising technology for high-efficiency cold-climate residential heating. The CSHP utilizes the heat of reversible chemical reactions between sorbent and refrigerant to extract heat from cold ambient and supply high-temperature heat to the indoors. The efficiency of CSHP depends on the ambient and heat rejection temperatures. This study evaluates the seasonal performance of a CSHP by first develop a dynamic system model to generate a performance map for various ambient and heat-supply temperatures; then the bin method is used to evaluate the CSHP seasonal performance in two cold-climate locations for space and water heating.

Yang, Zhiyao↗

Sorption heat pump and control method

A method operates an absorption heat pump system, specifically the flow of hydronic cooling fluid through the condenser during system start-ups, or when the cooling fluid temperature is low. To minimize the time for an absorption heat pump to reach full cooling or heating capacity, it is desirable for the high side pressure to increase as fast as possible, and the low side pressure to decrease as fast as possible. Since the high side pressure is a function of the temperature of the refrigerant exiting the condenser, if the condenser cooling fluid temperature is low, the corresponding high side pressure will be low, which may not permit adequate working fluid flow rates from the high pressure side of the system to the low pressure side.

Garrabrant, Michael A.↗

High-current conduction cooled superconducting radio-frequency cryomodule

A high-current, compact, conduction cooled superconducting radio-frequency cryomodule for particle accelerators. The cryomodule will accelerate an electron beam of average current up to 1 ampere in continuous wave (CW) mode or at high duty factor. The cryomodule consists of a single-cell superconducting radio-frequency cavity made of high-purity niobium, with an inner coating of Nb3Sn and an outer coating of pure copper. Conduction cooling is achieved by using multiple closed-cycle refrigerators. Power is fed into the cavity by two coaxial couplers. Damping of the high-order modes is achieved by a warm beam-pipe ferrite damper.

Ciovati, Gianluigi↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗

Delivering Effective Virtual Energy-Focused Trainings: Successful Strategies and Lessons Learned from the Virtual Cohort In-Plant Training Pilot

While there are always barriers to energy efficiency efforts, few challenges have been as severe as the global COVID-19 pandemic. Many manufacturers throughout the United States and the world have been trying to determine how to safely open and operate their plants. To minimize the number of people working within facilities and maximize the physical distance between workers, only essential facility engineers are allowed into plants to ensure proper operations. The Department of Energy’s Better Plants Program created In-Plant Trainings (INPLTs) to help partners develop in-house expertise in energy efficiency. Delivering INPLTs in the traditional in-person fashion is infeasible under these circumstances. To continue providing INPLTs during this difficult time, the Better Plants Program piloted Virtual Cohort In-Plant Trainings (VINPLTs) on wastewater treatment and ammonia industrial refrigeration systems from October 27 to November 19, 2020. This paper provides an overview of the pilot, then discusses successful strategies and lessons learned from this pilot for delivering effective virtual energy-focused trainings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Role of Competitions in Speeding Energy-Efficient Technology Development and Adoption

This conference paper, which will be submitted for publication in the 2020 ACEEE Summer Study on Energy Efficiency in Buildings, describes competition approaches used by the U.S. Department of Energy (DOE) Building Technologies Office (BTO) and other government agencies to encourage the development and adoption of innovative new energy-efficient, high-performing products while spurring external competition to maximize limited resources. The competition model helps to disrupt traditional thinking and introduce, expand, and evolve what’s possible within limited resource conditions. DOE BTO has sponsored technology competitions, including campaigns, challenges, prizes, and technology procurements to speed the uptake of more efficient refrigerators, clothes washers, air conditioners, and many types of highly efficient lighting technologies, including compact fluorescent lamps (CFLs) and light-emitting diode LED-based home and office luminaires, replacement lamps, and street lighting. In this paper, we will draw upon the technology competition frameworks employed by DOE BTO to support ongoing research and development efforts to illustrate the differences between the approaches and to identify which type is likely to be the most effective in a given technology status and market context. We’ll also share examples of the various technology competition types and results. A question-and-answer table helps readers compare and contrast the four competition types. The paper concludes with a summary of lessons learned from past DOE BTO competitions. The paper will be available in the ACEEE 2020 Summer Study proceedings and a related presentation will be given at the conference.

U.S. Department of Energy Building Technologies Of↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

The Response of Polarized Protons in Solid Hydrogen-Deuteride(HD) to Electron Beams

Solid frozen-spin polarized targets of hydrogen-deuteride(HD) have been proven advantageous in photon beam experiments, where they exhibit immeasurably long spin-relaxation times(T1). The present research investigates their potential applicability to experiments with minimum-ionizing charged-particle beams. Studies have been conducted with sub-nanoAmp CW currents of 10 MeV electron beams at the newly commissioned Upgraded Injector Test Facility (UITF) at Jefferson Lab (JLab). Since the energy deposition is almost independent of electron beam energy, these UITF experiments provide insight on the expected performance at the GeV energies required in typical JLab experiments. A horizontal in-beam dilution refrigerator equipped with superconducting solenoids has been used to maintain solid HD samples at about 0.1K and 1 Tesla. NMR coils sur rounding the HD target have been used to monitor hydrogen polarization. Thermal equilibrium polarizations of targets not in the frozen-spin state (with intentionally short T1) have been used to deduce the in situ temperature of solid HD while under electron bombardment. The behavior of a 40% H-polarized frozen-spin target has been tracked while exposed to beams under various conditions. Polarization loss has been observed to be approximately proportional to dose, with the target polarization dropping to 1/e of its initial value after about 6 µC cm2 , about 4 ? 1013 beam particles/cm2 . A model for depolarization by beam-associated paramagnetic impurities largely accounts for the data, and suggests that improvements in heat removal could lead to significant increases in the in-beam T1

Wei, Kevin↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling systems utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗