Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “real”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

A real-time probabilistic channel flood-forecasting model based on the Bayesian particle filter approach

Reliable real-time probabilistic flood forecasting is critical for effective water management and flood protection all over the world. In this study, we develop a real-time probabilistic channel flood-forecasting model by combining a channel hydraulic model with the Bayesian particle filter approach. The new model is tested in the upstream river reach of Three Gorges Dam (TGD) on the Yangtze River, China. Stage observations at seven hydrological stations are used simultaneously to adjust the Manning's roughness coefficients and to update discharges and stages along the river reach to attain reliable probabilistic flood forecasting. The synthetic experiments are applied to demonstrate the new model's correction and forecasting performances. The real-world experiments show that the new model can make accurate flood forecasting as well as derive reliable intervals for different confidence levels. The new probabilistic flood forecasting model not only outperforms the existing deterministic channel flood-forecasting models in accuracy, but also provides a more robust tool with which to incorporate uncertainty into flood-control efforts.

54 ENVIRONMENTAL SCIENCES↗

Real-time reduction of tungsten impurity influx using lithium powder injection in EAST

We report the first successful use of solid material injection, in powder form, to reduce core tungsten impurities in EAST discharges with tungsten divertor plasma-facing components. Tungsten is the leading plasma-facing material for use in ITER as well as future fusion devices. However, tungsten sometimes accumulates in the plasma core of fusion devices, which is an impediment to the achievement of high-power, long-pulse H-modes. In this work, tungsten impurity influx from the tungsten divertor was reduced by real-time injection of lithium powder into EAST discharges. An increase in stored energy and confinement accompanied the sharp reduction of core tungsten with real-time lithium powder injection in L-mode discharges. In H-mode discharges, real-time lithium powder injection reduced the tungsten core impurity emission while also mitigating ELMs. During powder injection, the divertor electron temperature was reduced, which reduced the tungsten source. In conclusion, the tungsten impurity emission remained low in discharges even after active lithium injection was terminated, a signature of improved and lasting wall conditioning in the tungsten divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time gas cooling of flowing liquid lithium limiter for the EAST

A novel continuously flowing liquid lithium limiter (FLiLi) which employs an in-vessel electro-magnetic pump to drive liquid Li flowing on the surface of limiter has been successfully designed and tested in the experimental advanced superconducting tokamak (EAST) device in 2014. In order to better control the surface temperature, an upgraded design and the real-time gas cooling were performed in 2016. Two kinds of cooling gas, helium (He) and argon (Ar) were tested on the FLiLi system prior to the experiment. It was found that the cooling rates of He and Ar at 2.5 MPa are 34.2 °C/min, 10.2 °C/min or 31.7 °C/kL and 28.1 °C/kL, respectively. The cooling performance of He is more effective than Ar. Experimental results show that the real-time He cooling could effectively contain the FLiLi surface temperature increase and prevent the strong passive evaporation of lithium during plasma discharges. Limiter heat flux up to 0.2 MW/m2 was removed during ohmic discharge with 2.5 MPa He gas. Finally, Because of the upgraded design and real-time gas cooling, the surface of FLiLi was not damaged by heat flux after entire plasma discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MPC-based double-layer real-time conditional cSelf-restoration for interconnected microgrids

In this report, we propose a novel model predictive control(MPC)-based real-time conditional self-restoration energy management system (CSR-EMS) for interconnected microgrids (IMGs) integrated with renewable energy sources (RESs) and energy storage systems (ESSs). Superior to the existing IMG self-restoration methods, the “conditionality” of the proposed CSR-EMS can economically realize self-restoration and grid-assisted restoration during energy deficiency or faults, in both islanded and grid-connected modes. Cost minimization is implemented as the objective function to judge in real-time which restoration mode is economically preferred. The proposed CSR-EMS comprises two layers–the lower layer operates locally to eliminate electricity fluctuations created by RESs and ensure economic effectiveness within an MG, whereas the upper layer oversees the real-time operational status of the IMG system and determines power exchange among microgrids (MGs) during abnormalities. In detail, when a microgrid inside the IMG system experiences an energy deficiency, the CSR-EMS, on an MPC basis, intelligently optimizes power production from each dispatchable distributed generator (DG), ESS, power imported from the main grid, and power exchange among the IMGs to maintain the demand–supply balance, while considering system recovery cost, state of charge (SoC) of ESSs and operation modes of the IMGs (i.e., grid-connected or islanded mode). Simulation results and comparisons with existing IMG self-healing EMSs demonstrate the economic efficacy of the proposed CSR-EMS strategy during normal and abnormal operations, which can be used as an energy control framework for modern power systems with multiple interconnected microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of Real-Time Intraoperative Ultrasound-Based Dosimetry With Postoperative Computed Tomography-Based Dosimetry for Prostate Brachytherapy

Purpose: To evaluate whether real-time intraoperative ultrasound (US)-based dosimetry can replace conventional postoperative computed tomography (CT)-based dosimetry in prostate brachytherapy. Methods and Materials: Between December 2001 and November 2002, 82 patients underwent {sup 103}Pd prostate brachytherapy. An interplant treatment planning system was used for real-time intraoperative transrectal US-guided treatment planning. The dose distribution was updated according to the estimated seed position to obtain the dose-volume histograms. Postoperative CT-based dosimetry was performed a few hours later using the Theraplan-Plus treatment planning system. The dosimetric parameters obtained from the two imaging modalities were compared. Results: The results of this study revealed correlations between the US- and CT-based dosimetry. However, large variations were found in the implant-quality parameters of the two modalities, including the doses covering 100%, 90%, and 80% of the prostate volume and prostate volumes covered by 100%, 150%, and 200% of the prescription dose. The mean relative difference was 38% and 16% for doses covering 100% and 90% of the prostate volume and 10% and 21% for prostate volumes covered by 100% and 150% of the prescription dose, respectively. The CT-based volume covered by 200% of the prescription dose was about 30% greater than the US-based one. Compared with CT-based dosimetry, US-based dosimetry significantly underestimated the dose to normal organs, especially for the rectum. The average US-based maximal dose and volume covered by 100% of the prescription dose for the rectum was 72 Gy and 0.01 cm{sup 3}, respectively, much lower than the 159 Gy and 0.65 cm{sup 3} obtained using CT-based dosimetry. Conclusion: Although dosimetry using intraoperative US-based planning provides preliminary real-time information, it does not accurately reflect the postoperative CT-based dosimetry. Until studies have determined whether US-based dosimetry or postoperative CT-based dosimetry can better predict patient outcomes, the American Brachytherapy Society recommendation of CT-based postimplant dosimetry should remain the standard of care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integration of Real-Time Internal Electromagnetic Position Monitoring Coupled With Dynamic Multileaf Collimator Tracking: An Intensity-Modulated Radiation Therapy Feasibility Study

Purpose: Continuous tumor position measurement coupled with a tumor tracking system would result in a highly accurate radiation therapy system. Previous internal position monitoring systems have been limited by fluoroscopic radiation dose and low delivery efficiency. We aimed to incorporate a continuous, electromagnetic, three-dimensional position tracking system (Calypso 4D Localization System) with a dynamic multileaf collimator (DMLC)-based dose delivery system. Methods and Materials: A research version of the Calypso System provided real-time position of three Beacon transponders. These real-time three-dimensional positions were sent to research MLC controller with a motion-tracking algorithm that changed the planned leaf sequence. Electromagnetic transponders were embedded in a solid water film phantom that moved with patient lung trajectories while being irradiated with two different plans: a step-and-shoot intensity-modulated radiation therapy (S-IMRT) field and a dynamic IMRT (D-IMRT) field. Dosimetric results were recorded under three conditions: no intervention, DMLC tracking, and a spatial gating system. Results: Dosimetric accuracy was comparable for gating and DMLC tracking. Failure rates for gating/DMLC tracking are as follows: {+-}3 cGy 10.9/ 7.5% for S-IMRT, 3.3/7.2% for D-IMRT; gamma (3mm/3%) 0.2/1.2% for S-IMRT, 0.2/0.2% for D-IMRT. DMLC tracking proved to be as efficient as standard delivery, with a two- to fivefold efficiency increase over gating. Conclusions: Real-time target position information was successfully integrated into a DMLC effector system to modify dose delivery. Experimental results show both comparable dosimetric accuracy as well as improved efficiency compared with spatial gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Practical Method of Adaptive Radiotherapy for Prostate Cancer Using Real-Time Electromagnetic Tracking

Purpose: We have created an automated process using real-time tracking data to evaluate the adequacy of planning target volume (PTV) margins in prostate cancer, allowing a process of adaptive radiotherapy with minimal physician workload. We present an analysis of PTV adequacy and a proposed adaptive process. Methods and Materials: Tracking data were analyzed for 15 patients who underwent step-and-shoot multi-leaf collimation (SMLC) intensity-modulated radiation therapy (IMRT) with uniform 5-mm PTV margins for prostate cancer using the Calypso Registered-Sign Localization System. Additional plans were generated with 0- and 3-mm margins. A custom software application using the planned dose distribution and structure location from computed tomography (CT) simulation was developed to evaluate the dosimetric impact to the target due to motion. The dose delivered to the prostate was calculated for the initial three, five, and 10 fractions, and for the entire treatment. Treatment was accepted as adequate if the minimum delivered prostate dose (D{sub min}) was at least 98% of the planned D{sub min}. Results: For 0-, 3-, and 5-mm PTV margins, adequate treatment was obtained in 3 of 15, 12 of 15, and 15 of 15 patients, and the delivered D{sub min} ranged from 78% to 99%, 96% to 100%, and 99% to 100% of the planned D{sub min}. Changes in D{sub min} did not correlate with magnitude of prostate motion. Treatment adequacy during the first 10 fractions predicted sufficient dose delivery for the entire treatment for all patients and margins. Conclusions: Our adaptive process successfully used real-time tracking data to predict the need for PTV modifications, without the added burden of physician contouring and image analysis. Our methods are applicable to other uses of real-time tracking, including hypofractionated treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electromagnetic Detection and Real-Time DMLC Adaptation to Target Rotation During Radiotherapy

Purpose: Intrafraction rotation of more than 45 Degree-Sign and 25 Degree-Sign has been observed for lung and prostate tumors, respectively. Such rotation is not routinely adapted to during current radiotherapy, which may compromise tumor dose coverage. The aim of the study was to investigate the geometric and dosimetric performance of an electromagnetically guided real-time dynamic multileaf collimator (DMLC) tracking system to adapt to intrafractional tumor rotation. Materials/Methods: Target rotation was provided by changing the treatment couch angle. The target rotation was measured by a research Calypso system integrated with a real-time DMLC tracking system employed on a Varian linac. The geometric beam-target rotational alignment difference was measured using electronic portal images. The dosimetric accuracy was quantified using a two-dimensional ion chamber array. For each beam, the following five delivery modes were tested: 1) nonrotated target (reference); 2) fixed rotated target with tracking; 3) fixed rotated target without tracking; 4) actively rotating target with tracking; and 5) actively rotating target without tracking. Dosimetric performance of the latter four modes was measured and compared to the reference dose distribution using a 3 mm/3% {gamma}-test. Results: Geometrically, the beam-target rotational alignment difference was 0.3 Degree-Sign {+-} 0.6 Degree-Sign for fixed rotation and 0.3 Degree-Sign {+-} 1.3 Degree-Sign for active rotation. Dosimetrically, the average failure rate for the {gamma}-test for a fixed rotated target was 11% with tracking and 36% without tracking. The average failure rate for an actively rotating target was 9% with tracking and 35% without tracking. Conclusions: For the first time, real-time target rotation has been accurately detected and adapted to during radiation delivery via DMLC tracking. The beam-target rotational alignment difference was mostly within 1 Degree-Sign . Dose distributions to fixed and actively rotating targets with DMLC tracking were significantly superior to those without tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System

Purpose: To investigate the frequency and amplitude of baseline shift or drift (shift/drift) of lung tumors in stereotactic body radiation therapy (SBRT), using a real-time tumor-tracking radiation therapy (RTRT) system. Methods and Materials: Sixty-eight patients with peripheral lung tumors were treated with SBRT using the RTRT system. One of the fiducial markers implanted near the tumor was used for the real-time monitoring of the intrafractional tumor motion every 0.033 seconds by the RTRT system. When baseline shift/drift is determined by the system, the position of the treatment couch is adjusted to compensate for the shift/drift. Therefore, the changes in the couch position correspond to the baseline shift/drift in the tumor motion. The frequency and amount of adjustment to the couch positions in the left-right (LR), cranio-caudal (CC), and antero-posterior (AP) directions have been analyzed for 335 fractions administered to 68 patients. Results: The average change in position of the treatment couch during the treatment time was 0.45 ± 2.23 mm (mean ± standard deviation), −1.65 ± 5.95 mm, and 1.50 ± 2.54 mm in the LR, CC, and AP directions, respectively. Overall the baseline shift/drift occurs toward the cranial and posterior directions. The incidence of baseline shift/drift exceeding 3 mm was 6.0%, 15.5%, 14.0%, and 42.1% for the LR, CC, AP, and for the square-root of sum of 3 directions, respectively, within 10 minutes of the start of treatment, and 23.0%, 37.6%, 32.5%, and 71.6% within 30 minutes. Conclusions: Real-time monitoring and frequent adjustments of the couch position and/or adding appropriate margins are suggested to be essential to compensate for possible underdosages due to baseline shift/drift in SBRT for lung cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Real-Time Image Gating on Spot Scanning Proton Therapy for Lung Tumors: A Simulation Study

Purpose: To investigate the effectiveness of real-time-image gated proton beam therapy for lung tumors and to establish a suitable size for the gating window (GW). Methods and Materials: A proton beam gated by a fiducial marker entering a preassigned GW (as monitored by 2 fluoroscopy units) was used with 7 lung cancer patients. Seven treatment plans were generated: real-time-image gated proton beam therapy with GW sizes of ±1, 2, 3, 4, 5, and 8 mm and free-breathing proton therapy. The prescribed dose was 70 Gy (relative biological effectiveness)/10 fractions to 99% of the target. Each of the 3-dimensional marker positions in the time series was associated with the appropriate 4-dimensional computed tomography phase. The 4-dimensional dose calculations were performed. The dose distribution in each respiratory phase was deformed into the end-exhale computed tomography image. The D99 and D5 to D95 of the clinical target volume scaled by the prescribed dose with criteria of D99 >95% and D5 to D95 <5%, V20 for the normal lung, and treatment times were evaluated. Results: Gating windows ≤ ±2 mm fulfilled the CTV criteria for all patients (whereas the criteria were not always met for GWs ≥ ±3 mm) and gave an average reduction in V20 of more than 17.2% relative to free-breathing proton therapy (whereas GWs ≥ ±4 mm resulted in similar or increased V20). The average (maximum) irradiation times were 384 seconds (818 seconds) for the ±1-mm GW, but less than 226 seconds (292 seconds) for the ±2-mm GW. The maximum increased considerably at ±1-mm GW. Conclusion: Real-time-image gated proton beam therapy with a GW of ±2 mm was demonstrated to be suitable, providing good dose distribution without greatly extending treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A simple extension of Roe's scheme for real gases

The purpose of this paper is to develop a highly accurate numerical algorithm to model real gas flows in local thermodynamic equilibrium (LTE). The Euler equations are solved using a finite volume method based on Roe's flux difference splitting scheme including real gas effects. A novel algorithm is proposed to calculate the Jacobian matrix which satisfies the flux difference splitting exactly in the average state for a general equation of state. This algorithm increases the robustness and accuracy of the method, especially around the contact discontinuities and shock waves where the gas properties jump appreciably. The results are compared with an exact solution of the Riemann problem for the shock tube which considers the real gas effects. In addition, the method is applied to a blunt cone to illustrate the capability of the proposed extension in solving two dimensional flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Goal-oriented real-time Bayesian inference for linear autonomous dynamical systems with application to digital twins for tsunami early warning

We present a goal-oriented framework for constructing digital twins with the following properties: (1) they employ discretizations of high-fidelity partial differential equation (PDE) models governed by autonomous dynamical systems, leading to large-scale forward problems; (2) they solve a linear inverse problem to assimilate observational data to infer uncertain model components followed by a forward prediction of the evolving dynamics; and (3) the entire end-to-end, data-to-inference-to-prediction computation is carried out without approximation and in real time through a Bayesian framework that rigorously accounts for uncertainties. Several challenges must be overcome to realize this framework, including the large scale of the forward problem, the high dimensionality of the parameter space, and for a class of problems including those we target, the slow decay of the singular values of the parameter-to-observable map. Here we introduce a methodology to overcome these challenges by exploiting the autonomous structure of the forward model to decompose the solution of the inverse problem into a one-time-only offline phase in which the PDE model is solved a limited number of times (equal to the number of sensors), and an online phase that maps well onto GPUs and computes the parameter inference and prediction of quantities of interest in real time, given observational data. Our ultimate goal is to apply this framework to construct digital twins for subduction zones, including Cascadia, to provide early warning for tsunamis generated by megathrust earthquakes. To this end, we demonstrate how our methodology can be used to employ seafloor pressure observations, along with the coupled acoustic–gravity wave equations, to infer the earthquake-induced spatiotemporal seafloor motion (discretized with $\mathscr{O}$ (10 9 ) parameters) and forward predict the tsunami propagation. We present results of an end-to-end inference, prediction, and uncertainty quantification for a representative test problem with $\mathscr{O}$ (10 8 ) inversion parameters for which goal-oriented Bayesian inference is accomplished exactly and in real time, that is, in a matter of seconds.

97 MATHEMATICS AND COMPUTING↗

Forecasting Multi-Step-Ahead Street-Scale Nuisance Flooding using a seq2seq LSTM Surrogate Model for Real-Time Application in a Coastal-Urban City

In coastal-urban cities facing an elevated risk of nuisance flooding (by rain and tide) due to increased heavy rainfall, sea level rise, urbanization, and aging drainage systems, real-time flood forecasting at the street-scale can provide useful information to transportation decision-makers. Physics-Based Models (PBMs) that offer high accuracy come with high computational runtimes and costs that limit their application for real-time flood forecasting. To address this challenge, Machine Learning (ML) surrogate models trained from PBMs have been proposed to provide street-scale flood forecasts. Previous related studies have focused on using Long Short-Term Memory (LSTM) architectures to model hourly flood depth on streets. While LSTM models can capture input sequences effectively, they fall short in accurately preserving output sequences, limiting their suitability for multi-step-ahead forecasts. The seq2seq LSTM architecture offers a key advantage here by capturing the full sequence of input–output, making it potentially more suitable for multi-step-ahead flood forecasts compared to traditional LSTM models. However, seq2seq LSTM has not been tested for street-scale flood forecasting, particularly for rapidly fluctuating nuisance flooding events which require special attention to its temporal sequences. Hence, in this study, we applied the seq2seq LSTM model to explore multi-step-ahead street-scale nuisance flooding and compared its results to the traditional LSTM model as a benchmark model. LSTM and seq2seq LSTM surrogate models were applied to 22 flood-prone streets in Norfolk, Virginia, as a case study with a 4-hr (short-term) and 8-hr (long-term) lead time. The models were trained with environmental (rainfall and tide) and topographic (elevation, Topographic Wetness Index, and Depth-To-Water) features along with PBM-derived water depths for different storm events. The results demonstrated satisfactory performance of both LSTM and seq2seq LSTM surrogate models throughout the forecast period compared to the PBM. However, the seq2seq LSTM showed lower Mean Absolute Error (MAE)/ Root Mean Square Error (RMSE) and higher Nash–Sutcliffe Efficiency (NSE)/ correlation than the LSTM across most lead times, particularly for long-term forecasting due to its supremacy in handling both input–output sequences together, which is missing in the traditional LSTM. For example, in the long-term, the average RMSE ranges were 0.0268–0.0373 m for LSTM and 0.0226–0.0319 m for seq2seq LSTM, while in the short-term, they were 0.0263–0.0293 m and 0.0261–0.0283 m, respectively. Additionally, while both models exhibited similar performance in distinguishing flooded and non-flooded streets for flood depth ≥ 0.1 m, the seq2seq LSTM model demonstrated superior performance for higher flood depths (such as ≥ 0.2 m and ≥ 0.3 m). Once trained, inference took only 0.09 to 0.11 s (short-term) and 0.30 to 0.35 s (long-term) per storm event for the 22 streets, making the application highly suitable for real-time decision-making during nuisance flood events.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty Studies of Real Anode Surface Area in Computational Analysis for Molten Salt Electrorefining

This study examines how much cell potential changes with five differently assumed real anode surface area cases. Determining real anode surface area is a significant issue to be resolved for precisely modeling molten salt electrorefining. Based on a three-dimensional electrorefining model, calculated cell potentials compare with an experimental cell potential variation over 80 hours of operation of the Mark-IV electrorefiner with driver fuel from the Experimental Breeder Reactor II. We succeeded to achieve a good agreement with an overall trend of the experimental data with appropriate selection of a mode for real anode surface area, but there are still local inconsistencies between theoretical calculation and experimental observation. In addition, the results were validated and compared with two-dimensional results to identify possible uncertainty factors that had to be further considered in a computational electrorefining analysis. These uncertainty factors include material properties, heterogeneous material distribution, surface roughness, and current efficiency. Zirconium's abundance and complex behavior have more impact on uncertainty towards the latter period of electrorefining at given batch of fuel. The benchmark results found that anode materials would be dissolved from both axial and radial directions at least for low burn-up metallic fuels after active liquid sodium bonding was dissolved.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flow field design for zero-gap microbial electrolysis cells using synthetic and real wastewater

Increasing performance in microbial electrolysis cells (MECs) requires the development of optimized reactor configurations with minimal internal resistance and capable to operate with real wastewater. Here, the impact of two different flow fields (serpentine and circular) was examined in zero-gap MECs with synthetic and real wastewaters. The serpentine flow field enabled a uniform distribution of the electrolyte in the anode chamber, resulting in larger current densities at lower flow rates compared to the circular flow field. Electrochemical tests using synthetic media with high buffer capacity revealed more stable and higher performance with the serpentine flow field compared to the circular flow path, producing larger current density (23.7 ± 0.8 A/m 2 vs 21.9 ± 5.6 A/m 2 ), hydrogen production rate (75.8 ± 4.1 L/L-d vs 54.3 ± 2.4 L/L-d), cathodic coulombic efficiency (>91 % vs >50 %), and an overall lower internal resistance (12.5 ± 0.5 mΩm 2 vs 14.8 ± 3.7 mΩm 2 ). Continuous operation for over 30 days with real wastewater indicated higher tolerance of the MECs with serpentine flow field toward media with large concentration of suspended solids, producing a current density of 5.4 ± 1.1 A/m 2 and a hydrogen production rate of 22.2 ± 6.2 L/L-d. Furthermore, the results presented here underscore the importance of reactor design and architecture in optimizing MEC performance for hydrogen production from liquid wastes.

flow path↗

On AgRhO{sub 2}, and the new quaternary delafossites AgLi{sub 1/3}M{sub 2/3}O{sub 2}, syntheses and analyses of real structures

Two new quaternary delafossite type oxides with the general formula Ag(Li{sub 1/3}M{sub 2/3})O{sub 2}, M=Rh, Ir, have been synthesized, and their structures characterized. Based on X-ray and electron diffraction analyses the structural similarity with AgRhO{sub 2} delafossite, has been evidenced. The real structures of the quaternary delafossites have been revealed, which has allowed to fully explain the diffuse scattering as observed in X-ray powder diffraction. AgRhO{sub 2} is thermally stable up to 1173 K, the behavior of the two quaternary compounds AgLi{sub 1/3}Rh{sub 2/3}O{sub 2} and AgLi{sub 1/3}Ir{sub 2/3}O{sub 2} is comparable, and they decompose above 950 and 800 K, respectively. AgRhO{sub 2} shows temperature independent paramagnetism, while for the other two an effective magnetic moment of 1.77{mu}{sub B} for Ir, and 1.70{mu}{sub B} for Rh were determined, applying the Curie-Weiss law. All compounds are semiconducting with activation energies of 4.97 kJ mol{sup -1} (AgLi{sub 1/3}Rh{sub 2/3}O{sub 2}), 11.42 kJ mol{sup -1} (AgLi{sub 1/3}Ir{sub 2/3}O{sub 2}) and 17.58 kJ mol{sup -1} (AgRhO{sub 2}). -- graphical abstract: Two new quaternary delafossite type oxides with the general formula Ag(Li{sub 1/3}M{sub 2/3})O{sub 2}, M=Rh, Ir, have been synthesized, and their structures characterized. The real structures of the quaternary delafossites have been revealed, which has allowed to fully explain the diffuse scattering as observed in X-ray powder diffraction. Display Omitted Highlights: {yields}Analysis of the real structures of the Ag(Li{sub 1/3}Rh{sub 2/3})O{sub 2} and Ag(Li{sub 1/3}Ir{sub 2/3})O{sub 2}. {yields} Diffuse scattering has been rationalized by severe disorder in the stacking sequences. {yields} The oxygen atom layer stacking sequence needs to change.

36 MATERIALS SCIENCE↗

New real ternary and pseudoternary phases in the Li-Au-In system

Two real ternary lithium gold indides LiAu{sub 2}In and Li{sub 280}Au{sub 22}In{sub 130} (Li{sub 0.65}Au{sub 0.05}In{sub 0.30}) were found in the Li-Au-In system. They are isostructural to the respective Ag-alloys. LiAu{sub 2}In crystallizes in the MnCu{sub 2}Al-type structure (Fm-3m, Heusler phase, a=6.4982(8) A, based on single crystal XRD-data) and Li{sub 280}Au{sub 22}In{sub 130} in the Li{sub 278}Ag{sub 40}In{sub 114}-type structure (F-43m, a=19.9970(2) A, based on powder XRD-data). The analogy of the two ternary systems Li-Au-In and Li-Ag-In is additionally reaffirmed by the wide homogeneity range of the pseudoternary solid solution with NaTl-type structure (Zintl phase),which expands not only in the direction of the quasibinary cut Li(Au{sub x}In{sub 1-x}) with 0{<=}x{<=}0.5, but also into the directions of both higher and lower Li-concentrations. -- Graphical abstract: Two real ternary compounds (1: Heusler phase, 2: n=6 variant of a cubic nxnxn W-type superstructure) together with one pseudoternary compound (3: Zintl phase with its broad homogeneity range). Display Omitted Highlights: {yields} 'Real' ternary phases were found in the Li-Au-In systems: LiAu{sub 2}In and Li{sub 280}Au{sub 22}In{sub 130}. {yields} The homogeneity range of 'pseudoternary' Li(Au{sub x}In{sub 1-x}) extends to the binary phase x=0. {yields} The three-element sets, both Li, Au, In and Li, Ag, In, are compound formers*. (*in the definition of Villars et al., J. Alloys Compd. 317-318, 2001, 26).

36 MATERIALS SCIENCE↗

Sim-to-real supervised domain adaptation for radioisotope identification

Machine learning has the potential to improve the speed and reliability of radioisotope identification using gamma spectroscopy. However, meticulously labeling an experimental dataset for training is often prohibitively expensive, while training models purely on synthetic data is risky due to the domain gap between simulated and experimental measurements. In this research, we demonstrate that supervised domain adaptation can substantially improve the performance of radioisotope identification models by transferring knowledge between synthetic and experimental data domains. We consider two domain adaptation scenarios: (1) a simulation-to-simulation adaptation, where we perform multi-label proportion estimation using simulated high-purity germanium detectors, and (2) a simulation-to-experimental adaptation, where we perform multi-class, single-label classification using measured spectra from handheld lanthanum bromide (LaBr) and sodium iodide (NaI) detectors. We begin by pretraining a spectral classifier on synthetic data using a custom transformer-based neural network. After subsequent fine-tuning on just 64 labeled experimental spectra, we achieve a test accuracy of 96% in the sim-to-real scenario with a LaBr detector, far surpassing a synthetic-only baseline model (75%) and a model trained from scratch (80%) on the same 64 spectra. Furthermore, we demonstrate that domain-adapted models learn more human-interpretable features than experiment-only baseline models. Overall, our results highlight the potential for supervised domain adaptation techniques to bridge the sim-to-real gap in radioisotope identification, enabling the development of accurate and explainable classifiers even in real-world scenarios where access to experimental data is limited.

Lalor, Peter W.↗