Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Hybrid method for monitoring large Fabry-Pérot cavity displacements with nanometer precision

The change in length of an optical fiber-based Fabry-Pérot cavity (FPC) can be precisely measured using phase tracking, but the displacement range is limited by phase ambiguity. Period tracking techniques determine the absolute FPC length, but with larger uncertainties from tracking the spacing between multiple peaks. A hybrid method is demonstrated that identifies appropriate peaks for phase tracking using a coarse estimate obtained from the free spectral range to effectively maintain the high precision (∼1 nm) of phase tracking techniques to measure ∼24 µ m displacements, well beyond the range limitations (typically <1 µ m) of phase tracking methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technology and times scales in Photonic Doppler Velocimetry (PDV)

Photonic Doppler Velocimetry (PDV) is a fiber-based measurement amenable to a wide range of experimental conditions. Interference between two optical signals—one Doppler shifted and the other not—is the essential principle in these measurements. A confluence of commercial technologies, largely driven by the telecommunication industry, makes PDV particularly convenient at near-infrared wavelengths. This discussion considers how measurement time scales of interest relate to the design, operation, and analysis of a PDV measurement, starting from the steady state through nanosecond resolution. Benefits and outstanding challenges of PDV are summarized, with comparisons to related diagnostics.

47 OTHER INSTRUMENTATION↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 3: Optical properties of black and brown carbon emissions

Residential biomass combustion is a source of carbonaceous aerosol. Inefficient combustion, particularly of solid fuels produces large quantities of black and brown carbon (BC and BrC). These particle types are important as they have noted effects on climate forcing and human health. One method of measuring these quantities is by measurement of aerosol light-absorption and scattering, which can be performed using an aethalometer and nephelometer, respectively. These instruments are widely deployed in the study of ambient air and are frequently used in air quality modeling and source apportionment studies. In this study, we will describe (1) a method for measuring primary BC and BrC emissions from two residential log-fired wood hydronic heaters and (2) the BC and BrC emission from these devices over a wide range of operating conditions, such as cold-starts, warm-starts, four different levels of output ranging from 15% to 100% maximum rated output, and periods of repeated cycling. The range in flue-gas BC concentrations, measured using an aethalometer at the 880 nanometer (nm) wavelength, were between 5.09 × 10 2 and 2.24 × 10 4 micrograms per cubic meter (µg/m 3 ) while the scattering coefficient of the flue-gas, measured by a nephelometer at 880 nm, ranged between 2.20 × 10 3 and 8.56 × 10 5 inverse megameters (Mm –1 ). The BrC concentrations, measured using the 370 nm wavelength of an aethalometer, were between 9.10 × 10 1 and 3.56 × 10 4 µg/m 3 . The calculated Angstrom Absorption Exponent (AAE) of the flue-gas aerosol ranged between 1.54 and 3.63. Performing a comparison between the measured BC concentration and an external particulate matter (PM) concentration showed that overall BC makes up roughly a quarter of the PM emitted by either of the two appliances. Further for both appliances, the cold-start and the test phase immediately following it had the highest BC and BrC concentrations, the highest measured scattering coefficient, as well as a low AAE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

169 Tm(n,2n) 168 Tm and 169 Tm(n,3n) 167 Tm cross-section measurements from 15 to 21 MeV

The 169 Tm(n,2n) 168 Tm and 169 Tm(n,3n) 167 Tm cross sections have been measured in the neutron energy range between 15 and 21 MeV using the 3 H(d,n) 4 He neutron source reaction. The 169 Tm(n,3n) 167 Tm data are intended to provide an accurate database for interpreting so-called reaction-in-flight neutron yields, which provide a sensitive tool for studying properties of the deuterium-tritium plasma created in inertial confinement fusion laser shots at the National Ignition Facility at Lawrence Livermore National Laboratory. The data are compared to previous data and evaluations for the reaction studied and are found to be in good agreement with the ENDF/B-VIII.0 evaluation, although small adjustments are necessary for the 169 Tm(n,3n) 167 Tm reaction. Here, for the first time in any (n,2n) cross-section measurements to date, a comprehensive data set ranging from threshold to 21 MeV has been obtained by the same group.

150 ≤ A ≤ 189↗

Total thermal neutron cross section measurements of yttrium hydride from 0.0005 - 3 eV

Yttrium hydride serves as a neutron moderator material that enables compact, high temperature nuclear reactors. However, in order to accurately design and simulate a nuclear system relying upon yttrium hydride, the fundamental nuclear data of yttrium hydride must be well understood. Thermal neutron scattering law (TSL) evaluations represent an important aspect of nuclear data as thermal scattering can drastically alter the neutron multiplication factor of a system. Therefore, to support evaluation and validation of thermal neutron scattering for yttrium hydride, researchers at Rensselaer Polytechnic Institute (RPI) performed total thermal neutron cross section measurements for YH 1.68 and YH 1.85 over the energy range of 0.0005 - 3 eV. Further, these measurements represent the first total cross section measurements for yttrium hydride that encompass the entire thermal region. Comparisons were made against the ENDF-B/VIII.0, Zerkle & Holmes and Oak Ridge National Laboratory TSL evaluations, where generally good agreement was found.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of the energy response of the ATLAS calorimeter to charged pions from $W^{\pm }\rightarrow \tau ^{\pm }(\rightarrow \pi ^{\pm }\nu _{\tau })\nu _{\tau }$ events in Run 2 data

The energy response of the ATLAS calorimeter is measured for single charged pions with transverse momentum in the range 10 < p T < 300 GeV. The measurement is performed using 139 fb –1 of LHC proton–proton collision data at √s = 13 TeV taken in Run 2 by the ATLAS detector. Charged pions originating from τ-lepton decays are used to provide a sample of high-p T isolated particles, where the composition is known, to test an energy regime that has not previously been probed by in situ single-particle measurements. The calorimeter response to single-pions is observed to be overestimated by ~2% across a large part of the p T spectrum in the central region and underestimated by ~4% in the endcaps in the ATLAS simulation. The uncertainties in the measurements are ≲1% for 15 < p T < 185 GeV in the central region. To investigate the source of the discrepancies, the width of the distribution of the ratio of calorimeter energy to track momentum, the energies per layer and response in the hadronic calorimeter are also compared between data and simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extending water vapor measurement capability of photon-limited differential absorption lidars through simultaneous denoising and inversion

Abstract. The micropulse differential absorption lidar (MPD) was developed at Montana State University (MSU) and the National Center for Atmospheric Research (NCAR) to perform range-resolved water vapor (WV) measurements using low-power lasers and photon-counting detectors. The MPD has proven to produce accurate WV measurements up to 6 km altitude. However, the MPD's ability to produce accurate higher-altitude WV measurements is impeded by the current standard differential absorption lidar (DIAL) retrieval methods. These methods are built upon a fundamental methodology that algebraically solves for the WV using the MPD forward models and noisy observations, which exacerbates any random noise in the lidar observations. The work in this paper introduces the adapted Poisson total variation (PTV) specifically for the MPD instrument. PTV was originally developed for a ground-based high spectral resolution lidar, and this paper reports on the adaptations that were required in order to apply PTV on MPD WV observations. The adapted PTV method, coined PTV-MPD, extends the maximum altitude of the MPD from 6 to 8 km and substantially increases the accuracy of the WV retrievals starting above 2 km. PTV-MPD achieves the improvement by simultaneously denoising the MPD noisy observations and inferring the WV by separating the random noise from the non-random WV. An analysis with 130 radiosonde (RS) comparisons shows that the relative root-mean-square difference (RRMSE) of WV measurements between RS and PTV-MPD exceeds 100 % between 6 and 8 km, whereas the RRMSE between RS and the standard method exceeds 100 % near 3 km. In addition, we show that by employing PTV-MPD, the MPD is able to extend its useful range of WV estimates beyond that of the ARM Southern Great Plains Raman lidar (RRMSE exceeding 100 % between 3 and 4 km); the Raman lidar has a power-aperture product 500 times greater than that of the MPD.

54 ENVIRONMENTAL SCIENCES↗

Elastic scattering of 3 He + 4 He with the SONIK scattering chamber

Measurements of the elastic scattering cross section of 3 He and 4 He are important in order to improve constraints on theoretical models of 4 He ⁢( 3 He ,𝛾)⁢ 7 Be, a key reaction in Big Bang nucleosynthesis and solar neutrino production. The astrophysical 𝑆 factor for this reaction is a significant source of uncertainty in the standard-solar-model prediction of the 7 Be and 8 B solar neutrino fluxes. The elastic scattering measurements reported in the literature do not extend to low energies and lack proper uncertainty quantification. A new measurement of the 4 He ⁢( 3 He, 3 He)⁢ 4 He reaction has been made at center-of-mass energies 𝐸c.m.=0.38−3.13 MeV using the Scattering of Nuclei in Inverse Kinematics (SONIK) scattering chamber: a windowless, extended gas target surrounded by an array of 30 collimated silicon charged particle detectors situated at TRIUMF. This is the first elastic scattering measurement of 3 He + 4 He made below 500 keV and it has greater angular range and better precision than previous measurements. The elastic scattering data were analyzed using both 𝑅-matrix and halo effective field theory frameworks, and values of the 𝑠-wave scattering length and effective range were extracted. Here, the resulting improvement in knowledge of the 𝑠-wave effective-range function at low energies reduces the overall uncertainty in 𝑆 34 at solar energies.

Elastic scattering reactions↗

Quantifying replication through repeated analysis of UVM-A, a liquid reference material for cosmogenic 10 Be and 26 Al studies

In this study, in-situ produced cosmogenic nuclide sample preparation and analysis is a complicated, multi-step process with numerous possible sources of error, many of which have not been robustly quantified. Here, we use a liquid reference material (UVM-A) to test whether the analytic precision associated with individual isotopic ratios (n = 96) measured at two Accelerator Mass Spectrometry facilities (Lawrence Livermore National Laboratory and Purdue Rare Isotope Measurement Laboratory) accurately represents the range of values determined for aliquots prepared in a single laboratory over a period of five years. We find that 10 Be/ 9 Be ratios measured at the different accelerator facilities (n = 26 and n = 70) have statistically indistinguishable central tendencies, matching to within 0.1 %. Based on this large dataset, we suggest preliminary consensus values for UVM-A of 1.45 ± 0.06 x 10 -13 for 10 Be/ 9 Be (mean, one standard deviation, n = 96) and 4.47 ± 0.22 x 10 -13 for 26 Al/ 27 Al (mean, one standard deviation, n = 27). For both 10 Be/ 9 Be and 26 Al/ 27 Al, the relative standard deviations of the measured ratios are similar to the reported analytic uncertainties of sample measurement, suggesting that sample preparation introduced little if any additional scatter beyond the uncertainty of isotopic analysis. This dataset demonstrates that robust sample preparation and measurement can generate isotope ratio data reproducible at the level of counting statistics.

58 GEOSCIENCES↗

Optical and x-ray characterization of the Daedalus ultrafast x-ray imager

The Daedalus ultrafast x-ray imager is the latest generation in Sandia’s hybrid CMOS detector family. With three frames along an identical line of sight, 1 ns minimum integration time, a higher full well than Icarus, and added features, Daedalus brings exciting new capabilities to diagnostic applications in inertial confinement fusion and high energy density science. In this work, we present measurements of time response, dynamic range, spatial uniformity, pixel cross-talk, and absolute x-ray sensitivity using pulsed optical and x-ray sources. Here, we report a measured 1.5 Me — full well, pixel sensitivity at 9.58 × 10 —7 V/e — , and an estimate of spatial uniformity at ~5% across the sensor array.

47 OTHER INSTRUMENTATION↗

Angular Distribution of Dimuons from Drell-Yan Production in p+Fe Interactions at 120 GeV Beam Energy

In the E906/SeaQuest Fermilab experiment, we report a measurement of the angular distributions by measuring the angular parameters $\lambda$, $\mu$, and $\nu$ of Drell-Yan dimuons produced using a 120 GeV proton beam incident on an iron target. The angular distribution in the naive Drell-Yan model does not show any $\cos2\phi$ dependency, where $\phi$ denotes the azimuthal angle of dimuons in the Collins-Soper frame. However, pion-induced Drell-Yan experiments, such as NA10 and E615, have observed a significant dependence on $\cos2\phi$. The Boer–Mulders function, a transverse momentum-dependent distribution function, represents the correlation between the transverse spin and the transverse momentum of the quark. A non-zero Boer-Mulders function or an improved higher-order Drell-Yan model considering QCD effects can produce a $\cos 2\phi$ modulation in the Drell-Yan angular distribution. To measure the angular distributions, we have used an event mixing method to construct the combin atorial background, which was then subtracted from the data to isolate the Drell-Yan signal. Following this, we corrected the detector, trigger, and reconstruction efficiencies using a doubly-iterative Bayesian Unfolding method. This iterative unfolding technique improves the response matrix based on the results of the previous unfolding step, ensuring robust convergence without exaggeration of uncertainties. The angular distributions of the dimuons were measured over the invariant mass range $5.0 < M_{\mu^+ \mu^-} < 8.0$ $GeV/c^2$, with dimuon transverse momentum $P_T < 2$ GeV/c and Feynman-x $-0.18 < x_F < 0.9$. The measured angular distributions are then compared with the QCD calculations for $p + \text{Fe}$ interactions, and proton-induced angular distribution measurements from other experiments. We have observed weak $\cos 2\phi$ modulations as a function of $P_T$. For $P_T > 1.0 \, \text{GeV}/c$, the predicted NNLO perturbative QCD value of $\nu$ is larger than what we have me asured at E906/SeaQuest. Moreover, we have not observed a strong dependence of $\nu$ on the kinematic variables, such as dimuon mass $M_{\mu^+ \mu^-}$ and Bjorken-$x$. The spin alignment of the virtual photon, $\lambda$, measured from the SeaQuest Drell-Yan $p+\text{Fe}$ data, is found to be strongly dependent on $P_T$, decreasing as $P_T$ increases. $\lambda$ also holds to the upper bound condition $\lambda < 1.0$ within the statistical uncertainty, showing a trend similar to that predicted by NNLO perturbative QCD. However, for $1.0 < P_T < 2.0 \, \text{GeV}/c$, the extracted $\lambda$ value from SeaQuest is smaller than that predicted by perturbative QCD at NNLO.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Comparative Radiative Property Evaluation of Sintered Bauxite and AMS4003 Ceramic Particles

The radiative properties of sintered bauxite (ACCUCAST ID80) and AMS4003 particles were measured and compared to assess their performances as direct absorption and heat transfer media for particle-based concentrated solar power (CSP) plants. Reflectance measurements were performed over the spectral range 0.2–20 µm and used to calculate solar and thermal emission properties of the particles. In addition, reflectance was measured as a function of temperature up to 1000 °C for the spectral range 1–20 µm. The solar absorptance of AMS4003 was greater than that of ACCUCAST both before and after thermal cycling of the materials at 1000 °C, although thermal cycling was found to substantially decrease the solar absorptance of both materials. The thermal emittance of AMS4003 was also greater than that of ACCUCAST at all temperatures tested. Finally, the radiaitve properties measured in this study were used to estimate absorber efficiencies as a way to compare the particles in terms of their performance in a solar receiver. AMS4003 yielded greater efficiencies than ACCUCAST, suggesting its potential as a material for CSP.

14 SOLAR ENERGY↗

Efficient loading of reduced data ensembles produced at ORNL SNS/HFIR neutron time-of-flight facilities

We present algorithmic improvements to the loading operations of certain reduced data ensembles produced from neutron scattering experiments at Oak Ridge National Laboratory (ORNL) facilities. Ensembles from multiple measurements are required to cover a wide range of the phase space of a sample material of interest. They are stored using the standard NeXus schema on individual HDF5 files. This makes it a scalability challenge, as the number of experiments stored increases in a single ensemble file. The present work follows up on our previous efforts on data management algorithms, to address identified input output (I/O) bottlenecks in Mantid, an open-source data analysis framework used across several neutron science facilities around the world. We reuse an in-memory binary-tree metadata index that resembles data access patterns, to provide a scalable search and extraction mechanism. In addition, several memory operations are refactored and optimized for the current common use cases, ranging most frequently from 10 to 180, and up to 360 separate measurement configurations. Results from this work show consistent speed ups in wall-clock time on the Mantid LoadMD routine, ranging from 19% to 23% on average, on ORNL production computing systems. The latter depends on the complexity of the targeted instrument-specific data and the system I/O and compute variability for the shared computational resources available to users of ORNL’s Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR) instruments. Nevertheless, we continue to highlight the need for more research to address reduction challenges as experimental data volumes, user time and processing costs increase.

Godoy, William↗

Mapping gas around massive galaxies: cross-correlation of DES Y3 galaxies and Compton- y maps from SPT and Planck

ABSTRACT We cross-correlate positions of galaxies measured in data from the first three years of the Dark Energy Survey with Compton-y maps generated using data from the South Pole Telescope (SPT) and the Planck mission. We model this cross-correlation measurement together with the galaxy autocorrelation to constrain the distribution of gas in the Universe. We measure the hydrostatic mass bias or, equivalently, the mean halo bias-weighted electron pressure 〈bhPe 〉, using large-scale information. We find 〈bhPe 〉 to be $[0.16^{+0.03}_{-0.04},0.28^{+0.04}_{-0.05},0.45^{+0.06}_{-0.10},0.54^{+0.08}_{-0.07},0.61^{+0.08}_{-0.06},0.63^{+0.07}_{-0.08}]$ meV cm−3 at redshifts z ∼ [0.30, 0.46, 0.62, 0.77, 0.89, 0.97]. These values are consistent with previous work where measurements exist in the redshift range. We also constrain the mean gas profile using small-scale information, enabled by the high-resolution of the SPT data. We compare our measurements to different parametrized profiles based on the cosmo-OWLS hydrodynamical simulations. We find that our data are consistent with the simulation that assumes an AGN heating temperature of 108.5 K but are incompatible with the model that assumes an AGN heating temperature of 108.0 K. These comparisons indicate that the data prefer a higher value of electron pressure than the simulations within r500c of the galaxies’ haloes.

79 ASTRONOMY AND ASTROPHYSICS↗

Deuteron-induced reactions on natural Zr from threshold to 50 MeV: production of 86g Y

Two stacks of thin Zr foils were irradiated with 30 and 50 MeV deuterons, respectively, using the Lawrence Berkeley National Laboratory 88-Inch Cyclotron, and 19 excitation functions for nat Zr(d,x) reactions were measured over a beam energy range of 6.3–47.64 MeV, where the independent cross sections for nat Zr(d,x) 88 Nb and nat Zr(d,x) 86m,g Y were measured for the first time. The well-characterized nat Fe(d,x) 56 Co, nat Ni(d,x) 56 Co, nat Ni(d,x) 58 Co, nat Ni(d,x) 61 Cu, nat Ti(d,x) 46 Sc and nat Ti(d,x) 48 V monitor reactions were used to determine the deuteron beam current throughout the stacks. All cross sections were determined using High Purity Germanium (HPGe) detector γ-ray spectroscopy. A variance minimization technique was employed to simultaneously constrain the deuteron beam currents with multiple monitor reactions, thus reducing systematic uncertainties. An additional 16 channels are reported for reactions on the nickel, titanium, and iron monitor foils, leading to a total of 35 excitation functions, with seven reaction channels reported for the first time in this work. The measured excitation functions are compared to calculations provided by the reaction modeling codes TALYS – 2.0, ALICE – 2020, CoH – 3.5.3 and EMPIRE – 3.2.3, as well as the TENDL – 2023 data library. The degree of agreement between theory and experiments is discussed. The possible production of the important PET radionuclide 86g Y via the nat Zr(d,x) route was critically examined. The physical yields for nat Zr(d,x) 86 Y and other yttrium isotopes produced were calculated and compared to other production pathways. Due to high-level of associated radionuclide impurities, this route cannot deliver 86g Y suitable for medical applications.

86gY↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Quantum Frequency Combs with Path Identity for Quantum Remote Sensing

Quantum sensing promises to revolutionize sensing applications by employing quantum states of light or matter as sensing probes. Photons are the clear choice as quantum probes for remote sensing because they can travel to and interact with a distant target. Existing schemes are mainly based on the quantum illumination framework, which requires quantum memory to store a single photon of an initially entangled pair until its twin reflects off a target and returns for final correlation measurements. Existing demonstrations are limited to tabletop experiments, and expanding the sensing range faces various roadblocks, including long-time quantum storage and photon loss and noise when transmitting quantum signals over long distances. We propose a novel quantum sensing framework that addresses these challenges using quantum frequency combs with path identity for remote sensing of signatures (“qCOMBPASS”). The combination of one key quantum phenomenon and two quantum resources—namely, quantum-induced coherence by path identity, quantum frequency combs, and two-mode squeezed light—allows for quantum remote sensing without requiring quantum memory. The proposed scheme is akin to a quantum radar based on entangled frequency-comb pairs that uses path identity to detect, range, or sense a remote target of interest by measuring pulses of one comb in the pair that never traveled to the target but that contains target information “teleported” by quantum-induced coherence by path identity from the other comb in the pair that traveled to the target but is not detected. We develop the basic qCOMBPASS theory, analyze the properties of the qCOMBPASS transceiver, and introduce the qCOMBPASS equation—a quantum analog of the well-known LIDAR equation in classical remote sensing. We also describe an experimental scheme to demonstrate the concept using two-mode squeezed quantum combs. qCOMBPASS can strongly impact various applications in remote quantum sensing, imaging, metrology, and communications. These applications include detection and ranging of low-reflectivity objects, measurement of small displacements of a remote target with precision beyond the standard quantum limit (SQL), standoff hyperspectral quantum imaging, discreet surveillance from space with low detection probability (detect without being detected), very-long-baseline interferometry, quantum Doppler sensing, quantum clock synchronization, and networks of distributed quantum sensors. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermo-acoustoelastic effect of Rayleigh wave: Theory and experimental verification

Previous studies showed that the thermally-induced ultrasonic bulk wave velocity change could be used to measure acoustoelastic coefficients and third-order elastic constants of elastic materials. This method is naturally immune from the ambient temperature effect and has improved sensitivity and a simpler test setup than the conventional acoustoelastic test. However, Rayleigh wave is preferred for thick components or structures with only one accessible surface. In this work, the thermo-hyperelastic constitutive equation, along with acoustoelastic theory, is used to derive the expression of the thermo-acoustoelastic coefficient (TAEC) of Rayleigh wave. The numerical relationship between the TAEC of Rayleigh wave and Murnaghan constants ( l, m and n ) are given for common metals. Further, the TAEC expressions for Rayleigh wave and shear wave are similar, and both are dominated by the constant m . The TAEC of Rayleigh wave was measured on an aluminum 6061 specimen using the thermal modulation experiment in a temperature range of 22 ~ 35°C. The measured TAEC shows good agreement with the theoretical calculation. Then the third-order elastic constants were calculated based on TAECs of bulk waves and Rayleigh wave.

42 ENGINEERING↗