Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quality control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

MO-AB-207-00: ACR Update in MR, CT, Nuclear Medicine, and Mammography

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗

MO-AB-207-03: ACR Update in Nuclear Medicine

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗

MO-AB-207-04: ACR Update in Mammography

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗

TU-A-18C-01: ACR Accreditation Updates in CT, Ultrasound, Mammography and MRI

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, the ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, mammography, ultrasound, and computed tomography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program. To understand the new requirements of the ACR ultrasound accreditation program, and roles the physicist can play in annual equipment surveys and setting up and supervising the routine QC program. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process.

60 APPLIED LIFE SCIENCES↗

MO-AB-207-02: ACR Update in MR

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗

MO-AB-207-01: ACR Update in CT

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗

Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Success in commissioning a key U.S. radioactive waste burial site through the technical support of Dufrane Nuclear Shielding Incorporated (DNSI) - 15476

With the -phase out- of the South Carolina based Barnwell Radioactive Waste Burial Site, and the stockpile and storage of radioactive waste and irradiated components throughout the U.S. Nuclear Industry for decades, the opening of the Texas Low-Level Radioactive Waste Disposal Compact Facility by Waste Control Specialists (WCS), is a game changer in solving this industry-wide issue. For the first time in decades, generators now have the opportunity to send their waste to a site specifically designed to permanently sequester the waste in a licensed facility that will protect public health and the environment, better than any built to date. As history has shown through the many decades of the U.S. Commercial and Federal Nuclear Industry, site operators and management have relied heavily on contractors and vendors with exceptional expertise and decades of experience to achieve success and meet their goals. The commissioning of WCS was no exception as DNSI was contracted to design, develop, build and deploy a major component required for the opening and successful operation of the WCS site. This component, being the Modular Concrete Canister (MCC), is the -work horse- of the site. With its enormous size, weight and strength, it provides many functions that meet and comply with the site performance assessment (PA) under 10 CFR Part 61, the site WAC, and Texas Low-Level Radioactive Waste Disposal Authority. Offsite contracting the production and delivery of this critical component was a major step toward success in meeting schedule and cost for the much needed opening of the Texas Compact and Federal site. In selecting a shielding vendor, WCS partnered with a U.S. Nuclear Service company with over 30 years of experience which spans the entire U.S. Commercial, Federal, and Nuclear Industry. The task given DNSI was not a simple one, it involved every aspect from start to finish of the design, production and delivery of rectangular, cylindrical and -irradiated hardware- (IH) MCCs, that could accept waste up to 100 Sv /Hr contact dose rates. The enormity of this project was quite clear and required extensive quality control, construction of batch plants, purchase of huge quantities of raw materials, setting up a production site in a neighboring city, relocation of personnel from company headquarters, and safely transporting 8,000 Tons of MCC components 75 miles one-way on West Texas highways daily. Most important of all, this was accomplished safely with no incidents, no component failures or rejects, and on schedule. The start of receipt, of -in-compact waste- and -out-of-compact waste- was conducted virtually in a 3 month period time span. To help guarantee success and quality of product, all forms had surfaces machined, heavy duty elastomer coatings were applied to concrete surfaces, only galvanized anchors were used, and the batch plant was run to strict ASME standards thus testing every 50 cubic yards of concrete poured. With significant teamwork and success from Vendors such as DNSI, WCS and the Texas Compact has evolved as one of the leading radioactive waste sites in the U.S. and the world, providing safe, secure and compliant permanent waste disposal services by using technical expertise and innovation of the highest standards. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel Platform for Digitization of Radiation Measurements, Decommissioning and Dismantling and Nuclear Waste Management - 18229

An innovative Platform for a seamless digitization of the information produced during the characterization of radioactive waste, contaminated objects, and in general radioprotection measurements has ben developed by CAEN SyS. The Platform is based on a spectroscopic handheld instrument integrating RFID technology, barcode reader, camera, voice recorder, and geo-localization, a selection of radiation tolerant RFID tags tested above 300 Gy integrated dose, ruggedized portable RFID readers and a secure database framework capable to collect data also from external sources such as gamma scanners and imaging systems. The Platform allows for real-time measurement of dose rate, radiation spectroscopy, tagging, tracking and inventorying of items. All data produced by the Platform are securely stored into the non-volatile memory of the RFID tags and in the database for both onsite and remote access to the information by operators. This paper presents the current development of the Platform and shows the advantages of such approach to achieve an easy yet reliable waste traceability, waste bagging optimization, and a structured methodology for radiation measurements, meeting an excellent quality control as increasingly required by Safety Authorities. Applications here envisaged and explored are dismantling and decontamination operations, radioprotection measurements and patrols, nuclear material management, safeguards and verification inspections. More in general, the Platform can address the needs of all plants, research laboratories and facilities that are looking to improve their Safety Standards, decrease operational costs, have a precise knowledge of the contaminated environment and objects as well as optimization for personnel dose minimization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Public Housing: A Tailored Approach to Energy Retrofits - Raleigh

More than 1 million U.S. Department of Housing and Urban Development-supported public housing units provide rental housing for eligible low-income families across the country. These units range from scattered single-family houses to high-rise apartments. In this project, the Advanced Residential Integrated Energy Solutions Collaborative (ARIES) worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time when units are refurbished between occupancies. ARIES conducted a survey of PHAs to assess their receptiveness to this concept and the applicability of the concept to PHA units. The results of the survey, to which more than 100 PHAs responded, support the proposed approach. The project consisted of a field evaluation in which energy audits were performed on a sample of PHA units at two housing authorities. Energy efficiency turnover protocols were developed for typical units, the protocol was implemented by PHA staff, and the effectiveness of the protocol was quantified through field testing and modeling. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. In the 10 housing units in which ARIES documented implementation, reductions in average air leakage of 16%-20% and duct leakage of 38% were obtained. Total source energy consumption savings was estimated at 6%-10% based on Building Energy Optimization modeling with a simple payback of 1.7-2.2 years. Implementation challenges were encountered, mainly related to required operational changes and budgetary constraints. Lack of complete training and inadequate quality control can prevent PHAs from effectively retrofitting units to their full potential. Nevertheless, despite these hurdles, simple improvements, such as caulking and sealing penetrations, windows, and doors; sealing duct boots; and adding pipe insulation into a standardized turnover protocol can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally. Islip Housing Authority - Single Story Typical home - Raleigh, NC Raleigh Housing Authority - 2 story typical home in Raleigh housing authority - Terrace Park

air filtration↗

A RESTful API for accessing microbial community data for MG-RAST

Metagenomic sequencing has produced significant amounts of data in recent years. For example, as of summer 2013, MGRAST has been used to annotate over 110,000 data sets totaling over 43 Terabases. With metagenomic sequencing finding even wider adoption in the scientific community, the existing web-based analysis tools and infrastructure in MG-RAST provide limited capability for data retrieval and analysis, such as comparative analysis between multiple data sets. Moreover, although the system provides many analysis tools, it is not comprehensive. By opening MG-RAST up via a web services API (application programmers interface) we have greatly expanded access to MG-RAST data, as well as provided a mechanism for the use of third-party analysis tools with MG-RAST data. This RESTful API makes all data and data objects created by the MG-RAST pipeline accessible as JSON objects. As part of the DOE Systems Biology Knowledgebase project (KBase, http:// kbase.us) we have implemented a web services API for MG-RAST. This API complements the existing MG-RAST web interface and constitutes the basis of KBase’s microbial community capabilities. In addition, the API exposes a comprehensive collection of data to programmers. This API, which uses a RESTful (Representational State Transfer) implementation, is compatible with most programming environments and should be easy to use for end users and third parties. It provides comprehensive access to sequence data, quality control results, annotations, and many other data types. Where feasible, we have used standards to expose data and metadata. Code examples are provided in a number of languages both to show the versatility of the API and to provide a starting point for users. We present an API that exposes the data in MG-RAST for consumption by our users, greatly enhancing the utility of the MG-RAST service.

59 BASIC BIOLOGICAL SCIENCES↗

FastProNGS: fast preprocessing of next-generation sequencing reads

Background Next-generation sequencing technology is developing rapidly and the vast amount of data that is generated needs to be preprocessed for downstream analyses. Yet, until now, software that can efficiently make all the quality assessments and filtration of raw data is still lacking. Results We developed FastProNGS to integrate the quality control process with automatic adapter removal. Parallel processing was implemented to speed up the process by allocating multiple threads. Compared with similar up-to-date preprocessing tools, FastProNGS is by far the fastest. Read information before and after filtration can be output in plain-text, JSON, or HTML formats with user-friendly visualization. Conclusions FastProNGS is a rapid, standardized, and user-friendly tool for preprocessing next-generation sequencing data within minutes. It is an all-in-one software that is convenient for bulk data analysis. It is additionally very flexible and can implement different functions using different user-set parameter combinations.

97 MATHEMATICS AND COMPUTING↗

Radiosynthesis and Biodistribution of {sup 99m}Tc-Metronidazole as an Escherichia coli Infection Imaging Radiopharmaceutical

Bacterial infection poses life-threatening challenge to humanity and stimulates to the researchers for developing better diagnostic and therapeutic agents complying with existing theranostic techniques. Nuclear medicine technique helps to visualize hard-to-diagnose deep-seated bacterial infections using radionuclide-labeled tracer agents. Metronidazole is an antiprotozoal antibiotic that serves as a preeminent anaerobic chemotherapeutic agent. The aim of this study was to develop technetium-99m-labeled metronidazole radiotracer for the detection of deep-seated bacterial infections. Radiosynthesis of {sup 99m}Tc-metronidazole was carried by reacting reduced technetium-99m and metronidazole at neutral pH for 30 min. The stannous chloride dihydrate was used as the reducing agent. At optimum radiolabeling conditions, ~ 94% radiochemical was obtained. Quality control analysis was carried out with a chromatographic paper and instant thin-layer chromatographic analysis. The biodistribution study of radiochemical was performed using Escherichia coli bacterial infection-induced rat model. The scintigraphic study was performed using E. coli bacterial infection-induced rabbit model. The results showed promising accumulation at the site of infection and its rapid clearance from the body. The tracer showed target-to-non-target ratio 5.57 ± 0.04 at 1 h post-injection. The results showed that {sup 99m}Tc-MNZ has promising potential to accumulate at E. coli bacterial infection that can be used for E. coli infection imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of cylindrically polarized vector vortex beams with digital micromirror device

We propose a novel technique to directly transform a linearly polarized Gaussian beam into vector-vortex beams with various spatial patterns. Full high-quality control of amplitude and phase is implemented via a Digital Micro-mirror Device (DMD) binary holography for generating Laguerre-Gaussian, Bessel-Gaussian, and helical Mathieu–Gaussian modes, while a radial polarization converter (S-waveplate) is employed to effectively convert the optical vortices into cylindrically polarized vortex beams. Additionally, the generated vector-vortex beams maintain their polarization symmetry after arbitrary polarization manipulation. Due to the high frame rates of DMD, rapid switching among a series of vector modes carrying different orbital angular momenta paves the way for optical microscopy, trapping, and communication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object. Conclusions: Three operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors’ results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.

60 APPLIED LIFE SCIENCES↗

Chromium-Based Mitigation Coatings on SiC Materials for Fuel Cladding

SiC composites are undergoing assessment under the Advanced Fuels Campaign for Light Water Reactors (LWR) as an Accident Tolerant Fuel (ATF) cladding. As noted, the main concern has been the hydrothermal corrosion of SiC under all LWR chemistries, resulting in cladding oxidation and recession unacceptable for the duration of burn-up. Improvements in future fuel burn-up further increase recession mitigation requirements. Hermeticity of ceramic cladding may also be a concern in terms of quality control. Coatings are being investigated as a practical solution to address concerns regarding SiC cladding for both accident conditions and normal operations. SiC materials were coated by various technologies to produce Cr-based mitigation coatings as a corrosion barrier in LWR water chemistry. In all cases, deposition of Cr compounds requires that SiC behave as a cathode during processing, which requires surface electrical conductivity. Morphology and phase analysis of the coatings are still undergoing investigation, mainly for predicting differential swelling, thermal expansion and microcracking. Autoclave corrosion and in-pile irradiation in a PWR water loop will follow in mid-2016. (authors)

36 MATERIALS SCIENCE↗

Maintenance of Maywood Laboratory Operations Support During Contractor Transition and Replacement of the Project Databases - 16329

In December 2013, Cabrera Services (Cabrera) executed transition of the FUSRAP Maywood Superfund Site remediation project operations, including an on-site accredited environmental lab, from a large business that had established technology infrastructure in place for over a decade which required updating to support the expected remediation scope and client needs. As of November 2015, Cabrera has shipped over 116,000 yd{sup 3} of contaminated soil to disposal facilities. During the transition, the USACE FUSRAP Maywood Laboratory (UFML) continued to support project operations, providing the expected timely and reliable results and maintaining their New Jersey Department of Environmental Protection certification for all parameters of concern, while having to cope with new challenges and additional tasks having the potential to disrupt the laboratory's ability to support project operations. This case study examines the challenges with maintaining a certified radiochemistry laboratory and an aggressive remediation schedule during a period of prime contractor transition which included a complete IT infrastructure overhaul, and conversion of the existing Microsoft Access laboratory database and project Electronic Data Management System (EDMS) to a customized commercial solution. Challenges: I. Procurement of a new database subcontractor and working closely with them to achieve the following: a. Migration of all environmental (including radiological, chemical, and quality control), health and safety, and spatial data as well as reports, queries, and analytical instrument software processes from a MS Access data management system to a SQL server system; and b. Verification that the functionality and data integrity of the databases remained intact. II. The onsite laboratory was changed over to a new onsite network and the following tasks were completed with little or no interruption to site operations by January 10, 2014: i. Installation of new instrument personal computers (PCs) and making them fully operational; ii. Configuration of the lab domain and server to host the LIMS (replaced all servers/domain/workstations with Windows 7 and Server 2012 machines). iii. Networking of the laboratory building into the rest of the project site via fiber optic cabling across the site. iv. Upgrade of the wide area network (WAN) data connection to high-speed Fiber Optic service; v. Upgrade of the telephones into voice over internet protocol (VOIP) phones. vi. Splitting of the database into front ends and a centralized back-end hosted on the new server to allow simultaneous access for fixes and improvements. III. Phone service interruption; phone systems were operational by January 10, 2014. Additional Tasks: I. Revision of the USACE FUSRAP Maywood Laboratory (UFML) Quality Systems Manual Rev. 1 Submitted 01/16/14; II. Writing of the Uniform Federal Policy Quality Assurance Project Plan Rev. 1 (UFP-QAPP) submitted 1/21/14. This document replaced the prior project data quality plan, the Chemical Data Quality Management Plan. III. Support of USACE communications to the New Jersey Department of Environmental Protection (NJDEP) on lab management and personnel transition to Cabrera. This work was important since it ensured a smooth transition and shows how critical project records infrastructure such as databases, can be upgraded with minimal interruption of project support. Such work may provide benefit to other similar projects, especially long term projects where database infrastructure upgrades may be beneficial in terms of improved efficiencies in data recording and transfer, and improved security in data storage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prevalence and variability in reporting of clinically actionable incidental findings on attenuation-correction CT scans in a veteran population

Background: Myocardial perfusion imaging (MPI) often employs attenuation-correction computed tomography (CTAC) to reduce attenuation artifacts and improve specificity. While there is no specific guideline on how they should be reported, incidental noncardiac findings identified on these scans may be clinically significant. The prevalence of these findings in veterans is not currently known. In addition, variability in reporting these findings may depend on the interpreting physician’s specialty. Methods: To guide future decision-making, CTACs in veterans referred for MPI were prospectively evaluated in a quality-control project for a set of prespecified actionable incidental findings by cardiologists and a radiologist. Results: On the 771 scans performed over eight months, 285 incidental noncardiac findings were identified by the interpreting cardiologists and 378 were identified by the interpreting radiologist. Pulmonary nodules were the most common occurring in 20% of studies read by the radiologist. Interreader agreements between cardiologists and the radiologist were poor for pulmonary nodules ≥ 10 mm and hiatal hernias; fair for pulmonary nodules < 10 mm, extracardiac masses, and aortic aneurysms; and moderate for pleural plaques. Conclusion: Incidental noncardiac findings on CTACs are common in our veteran population. Overall interobserver agreement in identifying these findings between cardiologists and radiologists is fair. Specific guidelines are needed on how CTACs should be read and reported.

62 RADIOLOGY AND NUCLEAR MEDICINE↗