Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Network reconfiguration and distributed energy resource scheduling for improved distribution system resilience

Electric utility companies work to restore as much load as possible after power outages caused by extreme weather events. In this paper, an outage management strategy is proposed to enhance distribution system resilience through network reconfiguration and distributed energy resources (DERs) scheduling. After a line fault, the proposed algorithm can identify radial network topology based on the rank of the incidence matrix. The reconfiguration is implemented by switching tie lines and sectionalizing lines. With the new network topology, an optimal DER scheduling problem is solved to minimize the accumulative cost for dispatchable DER operation and load reduction. Finally, the optimal topology that minimizes the accumulative cost is selected from all radial topologies. The computational workload is relatively low because only linear programming needs to be solved. Using the case studies of the IEEE 69-bus and IEEE 123-bus systems, we consider the worst-case scenarios in which faults occur in the upstream feeder. The simulation results demonstrate that the proposed strategy allows for a relatively high percentage of the load to remain in service after line faults. Furthermore, compared with microgrid-formation approaches, the proposed strategy has advantages when applied to the distribution systems with several normally-open tie lines and low DER penetration.

42 ENGINEERING↗

Overview of Potential Hazards in Electric Aircraft Charging Infrastructure

With increasing efforts in electrification of Advanced Air Mobility and electric aircraft, there is a growing need to install new infrastructure to support them. This report highlights potential hazards (non exhaustive) that the installation must be aware of and be prepared to mitigate with increased electrical equipment on site. The hazards can be due to natural causes as well as non natural causes. The report aims to provide starting guidelines for awareness of these hazards and to help plan for mitigation of the same.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An assessment of advanced displays and controls technology applicable to future space transportation systems

The topic of advanced display and control technology is addressed along with the major objectives of this technology, the current state of the art, major accomplishments, research programs and facilities, future trends, technology issues, space transportation systems applications and projected technology readiness for those applications. The holes that may exist between the technology needs of the transportation systems versus the research that is currently under way are addressed, and cultural changes that might facilitate the incorporation of these advanced technologies into future space transportation systems are recommended. Some of the objectives are to reduce life cycle costs, improve reliability and fault tolerance, use of standards for the incorporation of advancing technology, and reduction of weight, volume and power. Pilot workload can be reduced and the pilot's situational awareness can be improved, which would result in improved flight safety and operating efficiency. This could be accomplished through the use of integrated, electronic pictorial displays, consolidated controls, artificial intelligence, and human centered automation tools. The Orbiter Glass Cockpit Display is an example examined.

Hatfield, Jack J.↗

NEXT Single String Integration Test Results

As a critical part of NASA's Evolutionary Xenon Thruster (NEXT) test validation process, a single string integration test was performed on the NEXT ion propulsion system. The objectives of this test were to verify that an integrated system of major NEXT ion propulsion system elements meets project requirements, to demonstrate that the integrated system is functional across the entire power processor and xenon propellant management system input ranges, and to demonstrate to potential users that the NEXT propulsion system is ready for transition to flight. Propulsion system elements included in this system integration test were an engineering model ion thruster, an engineering model propellant management system, an engineering model power processor unit, and a digital control interface unit simulator that acted as a test console. Project requirements that were verified during this system integration test included individual element requirements ; integrated system requirements, and fault handling. This paper will present the results of these tests, which include: integrated ion propulsion system demonstrations of performance, functionality and fault handling; a thruster re-performance acceptance test to establish baseline performance: a risk-reduction PMS-thruster integration test: and propellant management system calibration checks.

Soulas, George C.↗

Masked fault detection for reliable low voltage cache operation

Systems, apparatuses, and methods for implementing masked fault detection for reliable low voltage cache operation are disclosed. A processor includes a cache that can operate at a relatively low voltage level to conserve power. However, at low voltage levels, the cache is more likely to suffer from bit errors. To mitigate the bit errors occurring in cache lines at low voltage levels, the cache employs a strategy to uncover masked faults during runtime accesses to data by actual software applications. For example, on the first read of a given cache line, the data of the given cache line is inverted and written back to the same data array entry. Also, the error correction bits are regenerated for the inverted data. On a second read of the given cache line, if the fault population of the given cache line changes, then the given cache line's error protection level is updated.

Ganapathy, Shrikanth↗

Resilience and fault tolerance in high-performance computing for numerical weather and climate prediction

Progress in numerical weather and climate prediction accuracy greatly depends on the growth of the available computing power. As the number of cores in top computing facilities pushes into the millions, increased average frequency of hardware and software failures forces users to review their algorithms and systems in order to protect simulations from breakdown. This report surveys hardware, application-level and algorithm-level resilience approaches of particular relevance to time-critical numerical weather and climate prediction systems. A selection of applicable existing strategies is analysed, featuring interpolation-restart and compressed checkpointing for the numerical schemes, in-memory checkpointing, user-level failure mitigation and backup-based methods for the systems. Numerical examples showcase the performance of the techniques in addressing faults, with particular emphasis on iterative solvers for linear systems, a staple of atmospheric fluid flow solvers. The potential impact of these strategies is discussed in relation to current development of numerical weather prediction algorithms and systems towards the exascale. Trade-offs between performance, efficiency and effectiveness of resiliency strategies are analysed and some recommendations outlined for future developments.

54 ENVIRONMENTAL SCIENCES↗

Controller for Driving a Piezoelectric Actuator at Resonance

A digital control system based partly on an extremum-seeking control algorithm tracks the changing resonance frequency of a piezoelectric actuator or an electrically similar electromechanical device that is driven by a sinusoidal excitation signal and is required to be maintained at or near resonance in the presence of uncertain, changing external loads and disturbances. Somewhat more specifically, on the basis of measurements of the performance of the actuator, this system repeatedly estimates the resonance frequency and alters the excitation frequency as needed to keep it at or near the resonance frequency. In the original application for which this controller was developed, the piezoelectric actuator is part of an ultrasonic/sonic drill/corer. Going beyond this application, the underlying principles of design and operation are generally applicable to tracking changing resonance frequencies of heavily perturbed harmonic oscillators. Resonance-frequency-tracking analog electronic circuits are commercially available, but are not adequate for the present purpose for several reasons: The input/output characteristics of analog circuits tend to drift, often necessitating recalibration, especially whenever the same controller is used in driving a different resonator. In the case of an actuator in a system that has multiple modes characterized by different resonance frequencies, an analog controller can tune erroneously to one of the higher-frequency modes. The lack of programmability of analog controllers is problematic when faults occur, and is especially problematic for preventing tuning to a higher-frequency mode. In contrast, a digital controller can be programmed to restrict itself to a specified frequency range and to maintain stability even when the affected resonator is driven at high power and subjected to uncertain disturbances and variable loads. The present digital control system (see figure) is implemented by means of an algorithm that comprises three main subalgorithms: a hill-climbing control algorithm, an estimation-based extremum-seeking control (ESC) algorithm, and a supervisory algorithm. The hill-climbing algorithm is useful for coarse tracking to find and remain within the vicinity of the resonance. The ESC algorithm is not capable of coarse resonance tracking, but is capable of fine resonance tracking once the estimates of parameters generated by the hill-climbing algorithm have converged sufficiently. On the basis of the parameter-estimation errors, the supervisory algorithm switches operation to whichever of the other two algorithms performs best at a given time.

Aldrich, Jack↗

Resource-Optimized Fermionic Local-Hamiltonian Simulation on a Quantum Computer for Quantum Chemistry

The ability to simulate a fermionic system on a quantum computer is expected to revolutionize chemical engineering, materials design, nuclear physics, to name a few. Thus, optimizing the simulation circuits is of significance in harnessing the power of quantum computers. Here, we address this problem in two aspects. In the fault-tolerant regime, we optimize the R z and T gate counts along with the ancilla qubit counts required, assuming the use of a product-formula algorithm for implementation. We obtain a savings ratio of two in the gate counts and a savings ratio of eleven in the number of ancilla qubits required over the state of the art. In the pre-fault tolerant regime, we optimize the two-qubit gate counts, assuming the use of the variational quantum eigensolver (VQE) approach. Specific to the latter, we present a framework that enables bootstrapping the VQE progression towards the convergence of the ground-state energy of the fermionic system. This framework, based on perturbation theory, is capable of improving the energy estimate at each cycle of the VQE progression, by about a factor of three closer to the known ground-state energy compared to the standard VQE approach in the test-bed, classically-accessible system of the water molecule. The improved energy estimate in turn results in a commensurate level of savings of quantum resources, such as the number of qubits and quantum gates, required to be within a pre-specified tolerance from the known ground-state energy. We also explore a suite of generalized transformations of fermion to qubit operators and show that resource-requirement savings of up to more than 20 % , in small instances, is possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

Guest Editorial: Special section on Resilient Control of Cyber-Physical Power and Energy Systems

Our power and energy systems are becoming more and more integrated and interconnected. The increasing integration of edge devices and dependence on cyber infrastructure provides both the potential for benefits and risks. The integration enables more dynamic and flexible control paradigms while at the same time increasing the cyberattack surface and uncertainty of behavior. Control methodology in this new world must be designed for resilience and must have the ability to withstand, react, and respond to both physical faults and cyber-induced threats. Finally, understanding system resilience under adverse conditions requires studying control performance and how cyber infrastructure can integrate with and support the overall resilience of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Recent Improvements of the SNS Extraction Kicker Power Supplies

A total of 14 extraction kickers., with one as the hot spare., are in service to extract protons out of the storage ring at the SNS. The jitter issue and the short lifetime of the switches were resolved after the thyratrons were replaced with solid state switches in 2018. This paper discusses the recent improvements. Two thyristor switches suffered overheating damage in separate incidents. One was due to the oil pump failure and the other was the result of a disconnected oil hose. An ultrasonic flow meter and a fiber optic temperature monitoring system have been installed for each extraction kicker power supply. The flow meter continuously monitors the entire tank oil flow. The temperature monitor detects the thyristor switch real-time temperatures in three locations. Fault thresholds are selected so that the thyristor switches are protected from overheating damage. Alarms are configured to alert staff to take actions before faults occur. In addition., the cause of an intermittent misfire issue was identified, and the solution was implemented. Lastly., a future oscilloscope upgrade and an oil level sensor are discussed.

Tan, Yugang↗

Generic Pressurized Water Reactor Model for SAPHIRE

Generic Pressurized Water Reactor Model for SAPHIRE This report contains a data dump from a SAPHIRE Generic Pressurized Water Reactor (PWR) model. The intent is to have this information reviewed for export control and classification so that the generic model can be used external to INL. The facility model is not applicable to any existing nuclear reactors. The Generic PWR model does not represent any existing power plant and was created to support research and training purposes. Three distinct types of data are used to create a SAPHIRE risk model: - Event trees representing typical PWR sequences - Fault trees representing generic system performance - Basic events (e.g., component failure information) Where possible, we have taken information from publicly available documents and referenced that information tagged to a specific item.

99 GENERAL AND MISCELLANEOUS↗

Developing Signal-Pattern-Recognition Programs

Pattern Interpretation and Recognition Application Toolkit Environment (PIRATE) is a block-oriented software system that aids the development of application programs that analyze signals in real time in order to recognize signal patterns that are indicative of conditions or events of interest. PIRATE was originally intended for use in writing application programs to recognize patterns in space-shuttle telemetry signals received at Johnson Space Center's Mission Control Center: application programs were sought to (1) monitor electric currents on shuttle ac power busses to recognize activations of specific power-consuming devices, (2) monitor various pressures and infer the states of affected systems by applying a Kalman filter to the pressure signals, (3) determine fuel-leak rates from sensor data, (4) detect faults in gyroscopes through analysis of system measurements in the frequency domain, and (5) determine drift rates in inertial measurement units by regressing measurements against time. PIRATE can also be used to develop signal-pattern-recognition software for different purposes -- for example, to monitor and control manufacturing processes.

Shelton, Robert O.↗

An Advanced Synchronized Time Digital Grid Twin Testbed for Relay Misoperation Analysis of Electrical Fault Type Detection Algorithms

Distributed energy resources and the number of relays are expected to rise in modern electrical grids; consequently, relay misoperations are also expected to grow. Relays can detect electrical fault types using an internal algorithm and can display the result using light indicators on the front of the relay. However, some relays’ internal algorithms for predicting types of electrical faults could be improved. This study assesses a relay’s external and internal algorithms with an Advanced Synchronized Time Digital Grid Twin (ASTDGT) testbed with paired relays. A misoperation relay analysis focused on measuring the accuracy of using the boundary admittance (the external algorithm) versus the set-default (the internal algorithm) relay method to determine the electrical fault types was performed. In this study, the internal and external relay algorithms were assessed with a synchronized time digital grid twin testbed using a real-time simulator. This testbed evaluated two sets of logic at the same time with the digital grid twin and paired relays in the loop. Different types of electrical faults were simulated, and the relays’ recorded events and electrical fault light indicator states were collected from the human–machine interfaces. This ASTDGT testbed with paired relays successfully evaluated the relay algorithm misoperations. The boundary admittance method had an accuracy of 100% for line-to-line, line-to-ground, and line-to-line ground faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA SpaceCube Edge TPU SmallSat Card for Autonomous Operations and Onboard Science-Data Analysis

Using state-of-the-art artificial intelligence (AI)frameworks onboard spacecraft is challenging because common spacecraft processors cannot provide comparable performance to datacenters with server-grade CPUs and GPUs available for terrestrial applications and advanced deep-learning networks. This limitation makes small, lo w-p o we r AI microchip architectures, such as the Google Coral Edge Tensor Processing Unit (TPU), attractive for space missions where the application-specific design enables both high-performance and power-efficient computing for AI applications. To address these challenging considerations for space deployment, this research introduces the design and capabilities of a CubeSat-sized Edge TPU-based co-processor card, known as the SpaceCube Low-power Ed g e Artificial Intelligence Resilient Node (SC-LEARN). This design conforms to NASA’s CubeSat Card Specification (CS2) for integration into next-generation SmallSat and CubeSat systems. This paper describes the overarching architecture and design of the SC-LEARN, as well as, the supporting test card designed for rapid prototyping and evaluation. The SC-LEARN was developed with three operational modes: (1) a high-performance parallel-processing mode,(2)a fault-tolerant mode for onboard resilience, and (3) a power-saving mode with cold spares. Importantly, this research also elaborates on both training and quantization of Tensor Flow models for the SC-LEARN for use onboard with representative, open-source datasets. Lastly, we describe future research plans, including radiation-beam testing and flight demonstration.

Advanced avionics↗

Application of Artificial Intelligence in Detection and Mitigation of Human Factor Errors in Nuclear Power Plants: A Review

Human factors and ergonomics have played an essential role in increasing the safety and performance of operators in the nuclear energy industry. In this critical review, we examine how artificial intelligence (AI) technologies can be leveraged to mitigate human errors, thereby improving the safety and performance of operators in nuclear power plants (NPPs). First, we discuss the various causes of human errors in NPPs. Next, we examine the ways in which AI has been introduced to and incorporated into different types of operator support systems to mitigate these human errors. We specifically examine (1) operator support systems, including decision support systems, (2) sensor fault detection systems, (3) operation validation systems, (4) operator monitoring systems, (5) autonomous control systems, (6) predictive maintenance systems, (7) automated text analysis systems, and (8) safety assessment systems. Finally, we provide some of the shortcomings of the existing AI technologies and discuss the challenges still ahead for their further adoption and implementation to provide future research directions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

5G integrated edge computing platform for efficient component monitoring in coal-fired power plants

This project developed a cutting-edge 5G-integrated edge computing framework to enhance operational efficiency and reliability in coal-fired power plants through real-time component monitoring and anomaly detection. The initiative focused on leveraging distributed machine learning, federated learning, and 5G-based dynamic network slicing to support scalable, fault-tolerant monitoring environments to meet the operational requirements in industrial control systems. With a Distributed Edge Computing Service (DECS) orchestration, this project enabled federated learning at edge for condition monitoring and introduced adaptive client selection strategies to minimize communication overhead. Scalable distributed training was achieved using the Horovod framework, thus enhancing performance across edge nodes. In the realm of 5G networking, the project designed and deployed reconfigurable, QoS-aware network slicing tailored for operational technology (OT) environments, integrating software-defined networks to bolster cyber-resilience and enabling dynamic slicing for federated learning workloads. A significant milestone was the development of a virtualized ICS environment with 5G core integration—which allowed elastic and fault tolerant distributed training on real-world datasets such as NASA Bearings, Hydraulic Systems, and TEP. To broaden the impact of the project, a TRL-3 virtualized ICS testbed for research and education was designed. This project engaged several graduate and undergraduate students to conduct research on the cutting-edge technology, and it resulted in one PhD dissertation, one MS thesis, and over 14 peer-reviewed publications. With the support of this project students also participated in national cybersecurity competitions to improve their professional development skills.

20 FOSSIL-FUELED POWER PLANTS↗