Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical pumping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Contemplating the plasmalemmal control center model

An abundant epidermal mechanosensory calcium-selective ion channel appears able not only to detect mechanical stimuli such as those that initiate gravitropism but also to detect thermal, electrical, and various chemical stimuli. Because it responds to multimodal input with a second messenger output, this channel system seems likely to be an integrator that can engage in feedbacks with many other systems of the cell--and feedback is the hallmark of regulation. In general, the mechanical tension required for channel activation is likely transmitted from the relatively rigid cell wall to the plasma membrane system via linkage or adhesion sites that display antigenicities recognized by antibodies to animal beta-1 integrin, vitronectin, and fibronectin and which have mechanical connections to the cytoskeleton. Thus, functionally, leverage exerted against any given adhesion site will tend to control channels within a surrounding domain. Reactions initiated by passage of calcium ions through the channels could presumably be more effectively regulated if channels within the domains were somewhat clustered and if appropriate receptors, kinases, porters, pumps, and some key cytoskeletal anchoring sites were in turn clustered about them. Accumulating evidence suggests not only that activity of clusters of channels may contribute to control of cytoskeletal architecture and of regulatory protein function within their domain, but also that both a variety of regulatory proteins and components of the cortical cytoskeleton may contribute to control of channel activity. The emerging capabilities of electronic optical microscopy are well suited for resolving the spatial distributions of many of these cytoskeletal and regulatory molecules in living cells, and for following some of their behaviors as channels are stimulated to open and cytosolic calcium builds in their vicinity. Such microscopy, coupled with biochemical and physiological probing, should help to establish the nature of the feedback loops putatively controlled by the linkage sites and their channel domains.

Review↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Thermal Control System Architecture and Technology Challenges for a Lunar Surface Habitat

NASA’s current plans for exploration of the Lunar South Pole region include a Surface Habitat (SH) to provide up to 60-day habitability for a crew of four. The SH concept is comprised of several elements including an inflatable volume for the habitable space and a metallic airlock for access to a pressurized rover and other surface assets. A conceptual architecture for the SH Thermal Control System (TCS) is presented. A TCS dual loop design is utilized with a water/propylene glycol mix for the internal crew spaces and an external loop with low temperature coolant. The internal loop is partitioned into low and moderate temperature service with a sublimator available for operational scenarios prior to thermal radiator deployment (or redeployment). Waste heat is rejected through thermal radiators contained in the external loop. Optimization of the thermal radiator geometry/orientation as well as the TCS internal/external loop architecture is accomplished via analytical models of the system. Low mass, dust tolerant, deployable/retractable thermal radiators (in partial gravity) and thermal control surfaces, along with accommodating infrequent eclipse periods lasting up to 100 hours, present the major technology challenges. Mitigation strategies to reduce the energy needed to maintain the SH and associated systems above survival temperature limits during the eclipse period are considered in the paper. Options include retractable radiators, re-generable heat exchangers, temperature excursions, thermal energy storage and optimized inflatable optical properties. TCS sensitivity to potential SH Electrical Power System (EPS) growth is also a consideration for both operational and dormant mission phases.

Thermal Control System↗

Millimeter-wave diode-grid frequency doubler

Monolithic diode grids were fabricated on 2-cm square gallium-arsenide wafers in a proof-of-principle test of a quasi-optical varactor millimeter-wave frequency multiplier array concept. An equivalent circuit model based on a transmission-line analysis of plane wave illumination was applied to predict the array performance. The doubler experiments were performed under far-field illumination conditions. A second-harmonic conversion efficiency of 9.5 percent and output powers of 0.5 W were achieved at 66 GHz when the diode grid was pumped with a pulsed source at 33 GHz. This grid had 760 Schottky-barrier varactor diodes. The average series resistance was 27 ohms, the minimum capacitance was 18 fF at a reverse breakdown voltage of -3 V. The measurements indicate that the diode grid is a feasible device for generating watt-level powers at millimeter frequencies and that substantial improvement is possible by improving the diode breakdown voltage.

Jou, Christina F.↗

Quantum noise and squeezing in optical parametric oscillator with arbitrary output coupling

The redistribution of intrinsic quantum noise in the quadratures of the field generated in a sub-threshold degenerate optical parametric oscillator exhibits interesting dependences on the individual output mirror transmittances, when they are included exactly. We present a physical picture of this problem, based on mirror boundary conditions, which is valid for arbitrary transmittances. Hence, our picture applies uniformly to all values of the cavity Q factor representing, in the opposite extremes, both perfect oscillator and amplifier configurations. Beginning with a classical second-harmonic pump, we shall generalize our analysis to the finite amplitude and phase fluctuations of the pump.

Prasad, Sudhakar↗

Power density in direct nuclear-pumped He-3 lasers

The interaction of neutron beams with He-3 gas is of interest for nuclear pumped lasers. The effects of spectral dependence of the neutron beam, neutron attenuation in the gas-filled laser tube, and transport of the charged-particle He-3(n, p)He-3 reaction products are treated in detail. An expression for the energy density as a function of position within the tube, tube radius, operating pressure, and neutron fluence is given. The maximum energy density within the optical cavity is achieved when the tube radius is 3.26/P where P (atm) is the operating pressure. The variation of radius by 50% above and below optimum will change the energy density at most by 10%, although performance degrades quickly for radii outside this range. If the optimum tube radius is used for each operating pressure, then the power density on the centerline (kW/cu cm) is given as 9.3 x 10 to the -18th power times the operating pressure times flux in a thermal neutron environment of flux (n/sq cm sec).

Wilson, J. W.↗

Airborne water vapor DIAL system development

A differential absorption lidar (DIAL) system developed at NASA Langley Research Center for the remote measurement of atmospheric H2O and aerosols from an aircraft is briefly discussed. This DIAL system utilizes a Nd:YAG laser-pumped dye laser as the off-line transmitter and a narrowband, tunable Alexandrite laser as the on-line transmitter. A 1-m monochromator and a multipass absorption cell are used to position the on-line laser to the center of the H2O line. The receiver system has a 14-in. diameter, f/7 Celestron telescope to collect the backscattered laser light and focus in into the detector optics. Return signals are converted to electrical signals by the optical detector and are digitalized and stored on magnetic tape. The results of fligh tests of the system are shown.

Higdon, Noah S.↗

Steady-State Characterization of Bacteriorhodopsin-D85N Photocycle

An operational characterization of the photocycle of the genetic mutant D85N of bacteriorhodopsin, BR-D85N, is presented. Steady-state bleach spectra and pump-probe absorbance data are obtained with thick hydrated films containing BR-D85N embedded in a gelatin host. Simple two- and three-state models are used to analyze the photocycle dynamics and extract relevant information such as pure-state absorption spectra, photochemical-transition quantum efficiencies, and thermal lifetimes of dominant states appearing in the photocycle, the knowledge of which should aid in the analysis of optical recording and retrieval of data in films incorporating this photochromic material. The remarkable characteristics of this material and their implications from the viewpoint of optical data storage and processing are discussed.

Timucin, Dogan A.↗

Time-Dependent Photodissociation Regions

We present theoretical models of the time-dependent thermal and chemical structure of molecular gas suddenly exposed to far-ultraviolet (FUV) (6 eV less than hv less than 13.6 eV) radiation fields and the consequent time- dependent infrared emission of the gas. We focus on the response of molecular hydrogen for cloud densities ranging from n = 10(exp 3) to 10(exp 6)/cu cm and FUV fluxes G(sub 0) = 10(exp 3)-10(exp 6) times the local FUV interstellar flux. For G(sub 0)/n greater than 10(exp -2) cu cm, the emergent H(sub 2) vibrational line intensities are initially larger than the final equilibrium values. The H(sub 2) lines are excited by FUV fluorescence and by collisional excitation in warm gas. Most of the H(sub 2) intensity is generated at a characteristic hydrogen column density of N approximately 10(exp 21)/sq cm, which corresponds to an FUV optical depth of unity caused by dust opacity. The time dependence of the H(sub 2) intensities arises because the initial abundances of H(sub 2) at these depths is much higher than the equilibrium values, so that H(sub 2) initially competes more effectively with dust in absorbing FUV photons. Considerable column densities of warm (T approximately 1000) K H(sub 2) gas can be produced by the FUV pumping of H(sub 2) vibrational levels followed by collisional de-excitation, which transfers the energy to heat. In dense (n greater than or approximately 10(exp 5)/cu cm) gas exposed to high (G(sub 0) greater than or approximately 10(exp 4)) fluxes, this warm gas produces a 2-1 S(1)/1-0 S(l) H(sub 2) line ratio of approximately 0.1, which mimics the ratio found in shocked gas. In lower density regions, the FUV pumping produces a pure-fluorescent ratio of approximately 0.5. We also present calculations of the time dependence of the atomic hydrogen column densities and of the intensities of 0 I 6300 A, S II 6730 A, Fe II 1.64 microns, and rotational OH and H20 emission. Potential applications include star-forming regions, clouds near active galactic nuclei, and planetary nebulae. We apply our models to five planetary nebulae and conclude that only BD +30deg3639 shows evidence of enhanced H(sub 2) emission due to (high) nonequilibrium H(sub 2) abundances.

Hollenbach, David↗

Optimal Signal Filtration in Optical Sensors with Natural Squeezing of Vacuum Noises

The structure of optimal receiver is discussed for optical sensor measuring a small displacement of probe mass. Due to nonlinear interaction of the field and the mirror, a reflected wave is in squeezed state (natural squeezing), two quadratures of which are correlated and therefore one can increase signal-to-noise ratio and overcome the SQL. A measurement procedure realizing such correlation processing of two quadratures is clarified. The required combination of quadratures can be produced via mixing of pump field reflected from the mirror with local oscillator phase modulated field in duel-detector homodyne scheme. Such measurement procedure could be useful not only for resonant bar gravitational detector but for laser longbase interferometric detectors as well.

Gusev, A. V.↗

Micro pulse lidar

An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering has been demonstrated. The transmitter of the micropulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited by optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that systems built on the micropulse lidar concept are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

Spinhirne, James D.↗

Micro pulse laser radar

An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering is disclosed. The transmitter of the micro pulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited to optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that micropulse lider systems are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

Spinhirne, James D.↗

Progress Toward a Compact, Highly Stable Ion Clock

There was an update on the subject of two previous NASA Tech Briefs articles: Compact, Highly Stable Ion Clock (NPO-43075), Vol. 32, No. 5 (May 2008), page 63; and Neon as a Buffer Gas for a Mercury-Ion Clock (NPO-42919), Vol. 32, No. 7 (July 2008), page 62. To recapitulate: A developmental miniature mercury-ion clock has stability comparable to that of a hydrogen-maser clock. The ion-handling components are housed in a sealed vacuum tube, wherein a getter pump maintains the partial vacuum, and the evacuated tube is backfilled with mercury vapor in a neon buffer gas. There was progress in the development of the clock, with emphasis on the design, fabrication, pump-down, and bake-out of the vacuum tube (based on established practice in the travelingwave- tube-amplifier industry) and the ability of the tube to retain a vacuum after a year of operation. Other developments include some aspects of the operation of mercury-vapor source (a small appendage oven containing HgO) so as to maintain the optimum low concentration of mercury vapor, and further efforts to miniaturize the vacuum and optical subsystems to fit within a volume of 2 L.

Prestage, John↗

NASA Tech Briefs, January 2006

Topics covered include: Semiautonomous Avionics-and-Sensors System for a UAV; Biomimetic/Optical Sensors for Detecting Bacterial Species; System Would Detect Foreign-Object Damage in Turbofan Engine; Detection of Water Hazards for Autonomous Robotic Vehicles; Fuel Cells Utilizing Oxygen From Air at Low Pressures; Hybrid Ion-Detector/Data-Acquisition System for a TOF-MS; Spontaneous-Desorption Ionizer for a TOF-MS; Equipment for On-Wafer Testing From 220 to 325 GHz; Computing Isentropic Flow Properties of Air/R-134a Mixtures; Java Mission Evaluation Workstation System; Using a Quadtree Algorithm To Assess Line of Sight; Software for Automated Generation of Cartesian Meshes; Optics Program Modified for Multithreaded Parallel Computing; Programs for Testing Processor-in-Memory Computing Systems; PVM Enhancement for Beowulf Multiple-Processor Nodes; Ion-Exclusion Chromatography for Analyzing Organics in Water; Selective Plasma Deposition of Fluorocarbon Films on SAMs; Water-Based Pressure-Sensitive Paints; System Finds Horizontal Location of Center of Gravity; Predicting Tail Buffet Loads of a Fighter Airplane; Water Containment Systems for Testing High-Speed Flywheels; Vapor-Compression Heat Pumps for Operation Aboard Spacecraft; Multistage Electrophoretic Separators; Recovering Residual Xenon Propellant for an Ion Propulsion System; Automated Solvent Seaming of Large Polyimide Membranes; Manufacturing Precise, Lightweight Paraboloidal Mirrors; Analysis of Membrane Lipids of Airborne Micro-Organisms; Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms; Dual-Laser-Pulse Ignition; Enhanced-Contrast Viewing of White-Hot Objects in Furnaces; Electrically Tunable Terahertz Quantum-Cascade Lasers; Few-Mode Whispering-Gallery-Mode Resonators; Conflict-Aware Scheduling Algorithm; and Real-Time Diagnosis of Faults Using a Bank of Kalman Filters.

Source record↗

Flight Readiness of Mochii S: Portable Spectroscopic Scanning Electron Microscope Facility on the International Space Station (ISS)

The ISS (International Space Station) currently lacks the capability to image and chemically analyze nano-to-micron scale particles from numerous engineering systems. To identify these particles, we must wait for a re-entry vehicle to return them from low earth orbit for ground-based SEM (Scanning Electron Microscope) / EDS (Energy Dispersive X-Ray Spectroscopy) analysis. This may take months, potentially delaying the affected system. Having an EDS-equipped SEM (Mochii S) aboard the ISS will accelerate response time thereby enhancing crew and vehicle safety by rapid and accurate identification of microscopic threats, especially in time-critical situations.The Mochii S payload will be stationed in the Japanese Experiment Module (JEM) powered by 120 VAC (Volts Alternating Current) inverter and connected to station Ethernet and WiFi (Fig. 1). To date the Mochii S payload has undergone testing for command and data handling, power quality, flight vibration, and radiation testing at Johnson Space Center (JSC). Mochii's high-RPM (Revolutions Per Minute) rotating vacuum pumps and high voltage systems have been reviewed to meet safety standards by JSC (Johnson Space Center) Engineering. Topology of the system in the JEM module has been baselined by ISS Safety and JAXA (Japan Space Exploration Agency). Digital controls to and from ISS over Joint Station LAN (Local Area Network) uplink have been simulated and the latencies and data rates have been found to be sufficient for successful operation of the payload from ground.Transporting sensitive electron optical instruments aboard a rocket that sustains 7G acceleration for 8 minutes and then operating it the unique microgravity (micro-g) environment is no trivial matter. To meet strict safety requirements and increase robustness for mission success, over 500 unique verifications must be completed before the payload is certified for spaceflight. Two of which will be discussed in detail are: vibroacoustic testing and magnetic susceptibility shielding and validation.

Mochii↗