Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Guided cold atom inertial sensors with membrane integrated photonics on atom trap integrated platforms

A guided cold-atom inertial sensor system comprises an atom trap integrated platform, a laser system, a magnetic field system, a control system, and a computing system. The laser system and magnetic field system are adapted to form a magneto-optical trap (MOT) about a suspended waveguide of the atom trap integrated platform made of membrane integrated photonics. After loading cold atoms from a MOT, the photonic atom trap integrated platform generates one-dimensional guided atoms with an evanescent field optical dipole trap (EF-ODT) along the optical waveguide to create guided atomic accelerometers/gyroscopes. Motion of atomic wavepackets in a superposition state is created along the guided atom geometry by way of state-dependent momentum kicks. The light-pulse sequence of guided atom interferometry splits, redirects, and recombines atomic wavepackets, which allows measurement of atom interference fringes sensitive to inertial forces via a probe laser.

Lee, Jongmin↗

Roadmap on quantum light spectroscopy

Conventional spectroscopy uses classical light to detect matter properties through the variation of its response with frequencies or time delays. Quantum light opens up new avenues for spectroscopy by utilizing parameters of the quantum state of light as novel control knobs and through the variation of photon statistics by coupling to matter. This Roadmap article focuses on using quantum light as a powerful sensing and spectroscopic tool to reveal novel information about complex molecules that is not accessible by classical light. It aims at bridging the quantum optics and spectroscopy communities which normally have opposite goals: manipulating complex light states with simple matter e.g. qubits versus studying complex molecules with simple classical light, respectively. Here, articles cover advances in the generation and manipulation of state-of-the-art quantum light sources along with applications to sensing, spectroscopy, imaging and interferometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation on Vibration Response of Aluminum Foam Beams Using Speckle Interferometry

This paper firstly presents a brief review on the representations of speckle fringe pattern in vibration measurement using time-averaged electronic speckle pattern interference (ESPI) method. Based on laser phase noise, a new representation of speckle fringe intensity generated by real-time subtraction ESPI method for vibrating measurement is then proposed. In the experimental performance, the real-time subtraction ESPI method is employed to inspect the vibrating response of a closed-cell aluminum foam cantilever beam. In contract with the results of the finite elemental method simulation, the vibration mode shapes obtained by the ESPI method are well agreed with numerical prediction. The optical vibration analysis is also carried out to determine the effective Young’s modulus of aluminum foam, and the results verify the validation of the ESPI method for investigation on mechanical properties of metal foam materials.

36 MATERIALS SCIENCE↗

Stitching methods at the European Synchrotron Radiation Facility (ESRF)

X-ray mirror quality has continuously improved over the past 20 years and manufacturers are now able to provide long mirrors with slope errors below 0.2 μrad. Nevertheless, these mirrors are mounted on holders or even mechanical benders to adjust their curvature and their intrinsic quality must be preserved from any parasitic deformation such as twist. The most direct method of detecting these deformations is to measure the 3D topography of the optical surface. At the ESRF metrology laboratory, three different stitching systems are under development based on Fizeau sub-aperture measurements. The first one consists of measuring long flat mirrors, the second based on the relative angle determinable stitching interferometry (RADSI) method developed at SPring-8 is aimed primarily at the measurement of short mirrors with strong curvature down to a few meters, and the last, also based on the RADSI method, is dedicated to characterize longer mirrors with intermediate curvature. For each method we will describe the measurement setup and discuss first results obtained. Micro-stitching interferometry is also currently used at the ESRF metrology laboratory. The technique is suitable for measuring deeply curved aspherical profiles and will be illustrated with results from a Kirkpatrick-Baez mirror system for nano-focusing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of dynamic patterns of an elastic membrane at bi-modal vibration using high speed electronic speckle pattern interferometry

Implementing a hybrid arrangement of Laser Doppler Vibrometry (LDV) and high speed Electronic Speckle Pattern Interferometry (ESPI) we were able to measure the dynamic patterns of a flat rectangular elastic membrane clamped at its edges stimulated with the sum of two resonance frequencies. ESPI is a versatile technique to analyze in real-time the deformation of a membrane since its low computational cost and easy implementation of the optical setup. Elastic membranes present nonlinear behaviors when stimulated with low amplitude signals. The elastic membrane under test, with several non rational related vibrating modals below the 200 Hz, was stimulated with two consecutives resonant frequencies. The ESPI patterns, acquired at high speed rates, shown a similar behavior for the dual frequency stimulation as in the case of patterns formed with the entrainment frequency. We think this may be related to the effects observed in the application of dual frequency stimulation in ultrasound.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct Writing of X-ray Gratings Using Zone-Plate-Array Lithography (ZPAL)

With the objective of providing the synchrotron and free-electron-laser communities with rapid turnaround and low prices for the highest quality and most advanced gratings and diffractive-focusing optics, LumArray has made specific improvements to its ZP-150 maskless photolithography system, which is based on Zone-Plate-Array Lithography (ZPAL), a technology unique to Lumarray. ZPAL’s advantages include an ability to correct in software for systematic patterning errors. Emphasis was placed on interferometric measurements of various contributors to patterning errors using Fizeau interferometry and a Mireau technique that was developed specifically for measuring errors within a micron-scale area. Average line-placement error was reduced below 20 nm using both pattern-file distortion and address-grid modification. The preferred implementation, address-grid modification, is hardware-based and requires no user intervention while also correcting more types of error. With continued iteration and refinement of the error measurements, we anticipate achieving global line-placement error below10nm. In order to investigate line-edge smoothness and high-frequency line-placement errors, a scheme for inspecting micron-sized areas was invented and implemented based on Mireau interferometry. This enabled the various contributions to be separately evaluated and measured. These included: exposure-dose variation, pattern-writing strategy and errors in the positioning of the microlenses. Deleterious crosstalk between microlenses was minimized via a pattern-dependent software modification. The impact of exposure threshold was revealed and adjustment made. The impact of address-grid fineness on line-edge roughness was likewise shown. Lastly, techniques were developed to measure and correct errors in the positioning of microlenses within the array. We expect final calibration of microlens positions to within 5nm.

42 ENGINEERING↗

Instabilities in a capacitively coupled oxygen plasma

Periodic fluctuations in the frequency range from 0.3 to 3 kHz were experimentally investigated in capacitively coupled radio frequency (13.56 MHz) oxygen plasma. The Gaussian beam microwave interferometry directly provides the line integrated electron density fluctuations. A system of two Langmuir probes measured the floating potential spatially (axial, radial) and temporally resolved. Hence, the floating potential fluctuation development is mapped within the discharge volume and provides a kind of discharge breathing and no wave propagation. Finally, it was measured the optical emission pattern of atomic oxygen during the fluctuation as well as the RF phase resolved optical emission intensity at selected phase position of the fluctuation by an intensified charge-coupled device camera. The deduced excitation rate pattern reveals the RF sheath dynamics and electron heating mechanisms, which is changing between low and high electronegativity during a fluctuation cycle. A perturbation calculation was taken into account using a global model with 15 elementary collision processes in the balance equations for the charged plasma species (O{sub 2}{sup +}, e, O{sup −}, O{sub 2}{sup −}) and a harmonic perturbation. The calculated frequencies agree with the experimentally observed frequencies. Whereby, the electron attachment/detachment processes are important for the generation of this instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation on lateral resolution of surface slope profilers

Here, we investigate and compare the spatial (lateral) resolution, or more generally, the optical/instrumental transfer function (OTF/ITF) of surface slope measuring profilometers of two different types that are commonly used for high accuracy characterization of x-ray optics at the long-spatial-wavelength range. These are an autocollimator based profiler, Optical Surface Measuring System (OSMS), and a long trace profiler, LTP-II, both available at the Advanced Light Source (ALS) X-Ray Optics Lab (XROL). In the OSMS, an ELCOMAT-3000 electronic auto-collimator, vertically mounted to the translation carriage and equipped with an aperture of 2.5 mm diameter, is scanned along the surface under test. The LTP-II OTF has been measured for two different configurations, a classical two-beam pencil-beam-interferometry and a single-Gaussian-beam deflectometry. For the ITF calibration, we apply a recently developed method based on test surfaces with one-dimensional (1D) linear chirped height profiles of constant slope amplitude. Analytical expressions for the OTFs, empirically deduced based on the experimental results, are presented. We also discuss the application of the results of the ITF measurements and modeling to improve the surface slope metrology with state-of-the-art x-ray mirrors.

42 ENGINEERING↗

Measurements of the linewidth enhancement factor of mid-infrared quantum cascade lasers by different optical feedback techniques

Precise knowledge of the linewidth enhancement factor of a semiconductor laser under actual operating conditions is of prime importance since this parameter dictates various phenomena such as linewidth broadening or optical nonlinearities enhancement. The above-threshold linewidth enhancement factor of a mid-infrared quantum cascade laser structure operated at 10{sup ∘}C is determined experimentally using two different methods based on optical feedback. Both Fabry-Perot and distributed feedback quantum cascade lasers based on the same active area design are studied, the former by following the wavelength shift as a function of the feedback strength and the latter by self-mixing interferometry. The results are consistent and unveil a clear pump current dependence of the linewidth enhancement factor, with values ranging from 0.8 to about 3.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Increasing future gravitational-wave detectors' sensitivity by means of amplitude filter cavities and quantum entanglement

The future laser interferometric gravitational-wave detectors' sensitivity can be improved using squeezed light. In particular, recently a scheme which uses the optical field with frequency-dependent squeeze factor, prepared by means of a relatively short ({approx}30 m) amplitude filter cavity, was proposed [Thomas Corbitt, Nergis Mavalvala, and Stan Whitcomb, Phys. Rev. D 70, 022002 (2004).]. Here we consider an improved version of this scheme, which allows one to further reduce the quantum noise by exploiting the quantum entanglement between the optical fields at the filter cavity two ports.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the surface profile of an axicon lens with a polarization phase-shifting shearing interferometer

We present a Twyman-Green interferometer (TGI)-based polarization phase-shifting shearing interferometric technique for testing the conical surface of an axicon (AX) lens. In this technique, the annular beam generated due to the passing of an expanded collimated laser beam traveling along the axis of revolution of the transparent glass AX element is split up into its reflected and transmitted components, having the plane of polarization in the orthogonal planes, by the polarization beam splitter (PBS) cube of the TGI-based optical setup. The split-up components are made to travel unequal paths along the two arms of the TGI and are recombined by the PBS. Because of the difference in path lengths traveled by the annular conical beams, a linear shear is introduced along the radial direction between the interfering components. Thus, the resulting interference pattern gives a map of the optical path difference (OPD) between two successive close points along a radial direction on the conical surface of the AX lens. The OPD map along radial directions, and hence the slopes/profiles of the conical surface, are obtained by applying polarization phase-shifting interferometry. Results obtained for an AX lens are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing Attosecond Bound Electron Dynamics Driven by Strong-Field Light Transients

The project aimed to drive strong-field excitation of bound electronic coherences in gas-phase atoms and molecules using a novel source of near-single-cycle optical field transients, based on industrial-grade Yb:solid-state laser technology. Key objectives included generating near-single cycle field transients and isolated attosecond pulses, reconstructing time-dependent wave packets in atoms and molecules, probing their decoherence using attosecond interferometry, and controlling the dynamic evolution of systems on attosecond to few-femtosecond timescales. A secondary goal of the project was to develop field-resolved measurement platforms as a novel approach for studying electron dynamics in atomic and molecular systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

VLBI ASTROMETRY OF PSR J2222-0137: A PULSAR DISTANCE MEASURED TO 0.4% ACCURACY

The binary pulsar J2222-0137 is an enigmatic system containing a partially recycled millisecond pulsar and a companion of unknown nature. While the low eccentricity of the system favors a white dwarf companion, an unusual double neutron star system is also a possibility, and optical observations will be able to distinguish between these possibilities. In order to allow the absolute luminosity (or upper limit) of the companion object to be properly calibrated, we undertook astrometric observations with the Very Long Baseline Array to constrain the system distance via a measurement of annual geometric parallax. With these observations, we measure the parallax of the PSR J2222-0137 system to be 3.742{sup +0.013}{sub -0.016} mas, yielding a distance of 267.3{sup +1.2}{sub -0.9} pc, and measure the transverse velocity to be 57.1{sup +0.3}{sub -0.2} km s{sup -1}. Fixing these parameters in the pulsar timing model made it possible to obtain a measurement of Shapiro delay and hence the system inclination, which shows that the system is nearly edge-on (sin i = 0.9985 {+-} 0.0005). Furthermore, we were able to detect the orbital motion of PSR J2222-0137 in our very long baseline interferometry (VLBI) observations and measure the longitude of ascending node {Omega}. The VLBI astrometry yields the most accurate distance obtained for a radio pulsar to date, and is furthermore the most accurate parallax for any radio source obtained at ''low'' radio frequencies (below {approx}5 GHz, where the ionosphere dominates the error budget). Using the astrometric results, we show that the companion to PSR J2222-0137 will be easily detectable in deep optical observations if it is a white dwarf. Finally, we discuss the implications of this measurement for future ultra-high-precision astrometry, in particular in support of pulsar timing arrays.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH-CONTRAST STELLAR OBSERVATIONS WITHIN THE DIFFRACTION LIMIT AT THE PALOMAR HALE TELESCOPE

We report on high-accuracy high-resolution (<20 mas) stellar observations obtained with the Palomar Fiber Nuller (PFN), a near-infrared ({approx_equal}2.2 {mu}m) interferometric coronagraph installed at the Palomar Hale telescope. The PFN uses destructive interference between two elliptical (3 m Multiplication-Sign 1.5 m) sub-apertures of the primary to reach high dynamic range inside the diffraction limit of the full telescope. In order to validate the PFN's instrumental approach and its data reduction strategy, based on the newly developed 'Null Self-Calibration' (NSC) method, we observed a sample of eight well-characterized bright giants and supergiants. The quantity measured is the source astrophysical null depth, or equivalently the object's visibility at the PFN 3.2 m interferometric baseline. For the bare stars {alpha} Boo, {alpha} Her, {beta} And, and {alpha} Aur, PFN measurements are in excellent agreement with previous stellar photosphere measurements from long baseline interferometry. For the mass-losing stars {beta} Peg, {alpha} Ori, {rho} Per, and {chi} Cyg, circumstellar emission and/or asymmetries are detected. Overall, these early observations demonstrate the PFN's ability to measure astrophysical null depths below 10{sup -2} (limited by stellar diameters), with 1 {sigma} uncertainties as low as a few 10{sup -4}. Such visibility accuracy is unmatched at this spatial resolution in the near-infrared and translates into a contrast better than 10{sup -3} within the diffraction limit. With further improvements anticipated in 2011/2012, a state-of-the-art infrared science camera and a new extreme adaptive optics system, the PFN should provide a unique tool for the detection of hot debris disks and young self-luminous sub-stellar companions in the immediate vicinity of nearby stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Sound speed measurements in lithium fluoride single crystals shock compressed to 168 GPa along [100]

The shock wave response of [100] lithium fluoride (LiF) single crystals at high stresses is of long-standing interest due to their extensive use as optical windows in dynamic compression experiments. The report of melting in shock compressed LiF single crystals between 134 GPa and 152 GPa – based on a single sound speed datum [J. Appl. Phys. 117, 045901 (2015)] – was surprising because good optical transmission was previously demonstrated in LiF shock compressed to ~200 GPa [J. Appl. Phys. 116, 033515 (2014)]. To address these apparent differences, we report on plate impact experiments on [100] LiF single crystals shock compressed to 168 GPa. Wave profiles were measured using laser interferometry to determine Hugoniot states and longitudinal sound speeds in shock compressed LiF. The measured Hugoniot states are in good agreement with those measured in previous studies. However, the measured sound speeds presented here show no evidence of melting up to 168 GPa. In particular, the abrupt drop reported previously in sound speed at 152 GPa was not observed in the present work. Furthermore, our results establish a lower bound of 168 GPa for the onset of melting in shock compressed LiF single crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DUST IN THE POLAR REGION AS A MAJOR CONTRIBUTOR TO THE INFRARED EMISSION OF ACTIVE GALACTIC NUCLEI

Dust around active galactic nuclei (AGNs) is distributed over a wide range of spatial scales and can be observed in the infrared (IR). It is generally assumed that the distribution on parsec scales forms a geometrically and optically thick entity in the equatorial plane around the accretion disk and broad-line region-dubbed {sup d}ust torus{sup -}that emits the bulk of the subarcsecond-scale IR emission and gives rise to orientation-dependent obscuration. However, recent IR interferometry studies with unprecedented position angle (P.A.) and baseline coverage on these small scales in two obscured (type 2) AGNs have revealed that the majority of the mid-IR emission in these objects is elongated in the polar direction. These observations are difficult to reconcile with the standard interpretation that most of the parsec-scale mid-IR emission in AGNs originate from the torus and challenges the justification of using simple torus models to model the broadband IR emission. Here, we report detailed interferometry observations of the unobscured (type 1) AGN in NGC 3783 that allow us to constrain the size, elongation, and direction of the mid-IR emission with high accuracy. The mid-IR emission is characterized by a strong elongation toward position angle P.A. -52 Degree-Sign , closely aligned with the polar axis (P.A. -45 Degree-Sign ). We determine half-light radii along the major and minor axes at 12.5 {mu}m of (20.0 {+-} 3.0) mas Multiplication-Sign (6.7 {+-} 1.0) mas or (4.23 {+-} 0.63) pc Multiplication-Sign (1.42 {+-} 0.21) pc, which corresponds to intrinsically scaled sizes of (69.4 {+-} 10.8) r{sub in} Multiplication-Sign (23.3 {+-} 3.5) r{sub in} for the inner dust radius of r{sub in} = 0.061 pc as inferred from near-IR reverberation mapping. This implies an axis ratio of 3:1, with about 60%-90% of the 8-13 {mu}m emission associated with the polar-elongated component. It is quite likely that the hot-dust emission as recently resolved by near-IR interferometry is misaligned with the mid-IR emitting source, which also finds a correspondence in the two distinct 3-5 {mu}m and 20 {mu}m bumps seen in the high angular resolution spectral energy distribution (SED). Based on this SED, we determine covering factors for the hot and warm dust components of C{sub hot}= 0.42{sup +0.42}{sub -0.21} and C{sub warm}= 0.92{sup +0.92}{sub -0.46}, respectively. We conclude that these observations support a scenario where the majority of the mid-IR emission in Seyfert AGNs originate from a dusty wind in the polar region of the AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray Lasers: The evolution from Star Wars to the table-top [PowerPoint]

X-ray lasers have evolved from a Star Wars missile defense system to a table-top research tool: (1) LLNL proposes X-ray laser schemes in the 1970’s, (2) First X-ray lasers demonstrated in early 1980’s were nuclear pumped, (3) Demonstrated the world’s shortest wavelength, highest energy laser, (4) First laboratory X-ray laser demonstrated on Novette in 1984, (5) A decade of progress using the Nova laser (5 kJ) from 1985 to 1996, (6) X-ray lasers produced at the COMET table-top facility (<10 J) since 1997, (7) X-ray lasers used for plasma interferometry and other applications, (8) 10 Hz X-ray laser at 18.9 nm demonstrated in 2004 using 0.15 J drive, (9) 100 Hz X-ray laser at 13.9 nm produces 1 µJ of saturated output using 0.9 J drive from diode-pumped optical laser in 2014.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Stellar Characterization of FGKM Stars using an Empirical Spectral Library

Classification of stars, by comparing their optical spectra to a few dozen spectral standards, has been a workhorse of observational astronomy for more than a century. Here, we extend this technique by compiling a library of optical spectra of 404 touchstone stars observed with Keck/HIRES by the California Planet Search. The spectra have high resolution ( R ≈ 60,000), high signal-to-noise ratio (S/N ≈ 150/pixel), and are registered onto a common wavelength scale. The library stars have properties derived from interferometry, asteroseismology, LTE spectral synthesis, and spectrophotometry. To address a lack of well-characterized late-K dwarfs in the literature, we measure stellar radii and temperatures for 23 nearby K dwarfs, using modeling of the spectral energy distribution and Gaia parallaxes. This library represents a uniform data set spanning the spectral types ∼M5–F1 ( T {sub eff} ≈ 3000–7000 K, R {sub ⋆} ≈ 0.1–16 R {sub ⊙}). We also present “Empirical SpecMatch” (SpecMatch-Emp), a tool for parameterizing unknown spectra by comparing them against our spectral library. For FGKM stars, SpecMatch-Emp achieves accuracies of 100 K in effective temperature ( T {sub eff}), 15% in stellar radius ( R {sub ⋆}), and 0.09 dex in metallicity ([Fe/H]). Because the code relies on empirical spectra it performs particularly well for stars ∼K4 and later, which are challenging to model with existing spectral synthesizers, reaching accuracies of 70 K in T {sub eff}, 10% in R {sub ⋆}, and 0.12 dex in [Fe/H]. We also validate the performance of SpecMatch-Emp, finding it to be robust at lower spectral resolution and S/N, enabling the characterization of faint late-type stars. Both the library and stellar characterization code are publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗