Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Quantification of Dynamic Scattering Effects in Molecular Crystals using Large Angle Rocking Beam Electron Diffraction

Electron crystallography provides a pathway to solve structure of small crystals (< 1um) in size, and thus overcomes difficult synthesis constraints involved in growing large crystals. Generally, electron diffraction data is collected in the form of integrated intensity using continuous rotation or by precession. The measured intensities in 3D are utilized for structure solution. Using this approach, structure solution of difficult crystals, such as small crystals of zeolites, metal-organic frameworks, molecular crystals, and proteins , can be solved by electron diffraction. However, electron structure solutions are regularly reported with higher Rvalues than x-ray or neutron diffraction. While similar structures are found despite the high R-values, the differences in the measure intensity and theory calculated intensity limit information that can be extracted by electron diffraction. Previous work demonstrated that including multiple-scattering effects significantly reduce the R-values . Thus, it is critical to be able to quantify the dynamical diffraction effects in molecular crystals.

Crystallography↗

Search for hadronic decays of feebly-interacting particles at NA62

The NA62 experiment at CERN has the capability to collect data in a beam-dump mode, where 400 GeV protons are dumped on an absorber. In this configuration, New Physics particles, including dark photons, dark scalars, and axion-like particles, may be produced in the absorber and decay in the instrumented volume beginning approximately 80 m downstream of the dump. A search for these particles decaying in flight to hadronic final states is reported, based on an analysis of a sample of 1.4 x 10 17 protons on dump collected in 2021. No evidence of a New Physics signal is observed, excluding new regions of parameter spaces of multiple models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron measurement from neutrino interactions in NOvA

The NuMI Off-Axis Appearance (NOvA) experiment is a long-baseline neutrino oscillation experiment based at Fermilab, consisting of two functionally identical liquid-scintillator detectors positioned slightly off-axis from the NuMI beam. It aims to probe CP violation in the lepton sector and determine the neutrino mass ordering by comparing the oscillation rates between the detectors. Given the energy dependence of oscillations, energy reconstruction is key--and a key limitation in the precision and accuracy of this kinematic variable is an understanding of primary neutron-related uncertainties since many may go undetected. While recent improvements have reduced discrepancies, NOvA's simulation still overpredicts neutron-linked activity by about 20\%, particularly for neutrons between 5–200 MeV. We present ongoing progress toward a measurement of neutron multiplicity in the NOvA Near Detector using spatially displaced and delayed energy deposits associated with neutron interactions, aiming to constrain neutron-related systematics and improve neutrino energy reconstruction in future oscillation analyses.

Kufatty, G. [Florida State U.]↗

Overview of the Fiber System for the Dark Energy Spectroscopic Instrument

The Dark Energy Spectroscopic Instrument (DESI) is a revolutionary instrument designed for precise measurements of cosmic distances and the investigation of dark energy. DESI utilizes 5000 optical fibers to simultaneously measure the spectra of distant objects and aims to measure 40 million galaxies and quasars in a 5 yr survey. One of the critical challenges to DESI's success was ensuring that the fiber system was not only highly efficient but also delivered a highly stable beam enabling more reliable sky subtraction for measurements of faint objects. We achieved this stability by minimizing the stress on the fiber system during the manufacture and operation of the telescope and fiber positioning robots. We installed the DESI fiber system on the 4 m Mayall telescope with ≥99% of fibers intact, and the instrument has delivered superb optical performance throughout the initial years of the DESI survey, including ≥90% average throughput when injected with a focal ratio of ~f/3.9 as delivered by the primary focus corrector, excluding fiber absorption losses. The design of DESI required multiple innovations to achieve these requirements, such as cleaved fibers bonded with a UV-curing epoxy to glass ferrules in the focal plane and fusion splicing instead of physical connectors. In this paper, we describe the development, delivery, and installation of the fiber system, the innovations that made the state-of-the-art performance possible, and the key lessons learned that could benefit future projects.

79 ASTRONOMY AND ASTROPHYSICS↗

Science Federation Emulation Testbed: Demonstration of VFSIE Functionalities

The Virtual Federated Science Instrument Environment (VFSIE) is a digital twin of a federated infrastructure of multiple sites with science instruments and computing systems that are geographically dispersed. It emulates the federation using containers and virtual hosts (vhosts) connected over local and wide-area networks for the main purpose of supporting the development and testing of science workflows and software stacks, which will subsequently transition to the physical infrastructure. In this demo, we present VFSIE of a four sites scenario and illustrate the following use cases: (i) execution of federation stack components that expose resources to enable a science user to execute workflows, (ii) execution of remote control commands of beam-line instruments to collect measurements and position the sensor, and (iii) remote execution and access of Jupyter Notebook for tomographic image computations

Al Najjar, Anees↗

Inference of bipolar neutrino flavor oscillations near a core-collapse supernova based on multiple measurements at Earth

Neutrinos in compact-object environments, such as core-collapse supernovae, can experience various kinds of collective effects in flavor space, engendered by neutrino-neutrino interactions. These include “bipolar” collective oscillations, which are exhibited by neutrino ensembles where different flavors dominate at different energies. Considering the importance of neutrinos in the dynamics and nucleosynthesis in these environments, it is desirable to ascertain whether an Earth-based detection could contain signatures of bipolar oscillations that occurred within a supernova envelope. To that end, we, in this study, continue examining a cost-function formulation of statistical data assimilation (SDA) to infer solutions to a small-scale model of neutrino flavor transformation. SDA is an inference paradigm designed to optimize a model with sparse data. Our model consists of two monoenergetic neutrino beams with different energies emanating from a source and coherently interacting with each other and with a matter background, with radially varying interaction strengths. We attempt to infer flavor transformation histories of these beams using simulated measurements of the flavor content at locations “in vacuum” (that is, far from the source), which could in principle correspond to Earth-based detectors. Within the scope of this small-scale model, we found that: (i) based on such measurements, the SDA procedure is able to infer whether bipolar oscillations had occurred within the protoneutron star envelope, and (ii) if the measurements sample the full amplitude of the neutrino oscillations in vacuum, then the amplitude of the prior bipolar oscillations is well predicted. This result intimates that the inference paradigm can well complement numerical integration codes, via its ability to infer flavor evolution at physically inaccessible locations.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cavitation-induced erosion in liquid metal spallation targets – A comparison between a predictive method and measured erosion damage to stainless steel target modules at the Spallation Neutron Source

Neutrons are produced for neutron scattering instruments at the Spallation Neutron Source by bombarding liquid mercury with a pulsed high-energy proton beam. The liquid mercury target material flows through a replaceable stainless-steel target vessel and cavitates during operation due to the extremely high heating rate caused by each proton pulse. Cavitation-induced erosion damage to the mercury-facing surfaces of target vessels is a key concern for target lifetime and has been the subject of considerable research. While numerous experiments have studied and modeled the progression of cavitation erosion damage to liquid metal target containers, direct quantitative measurements of actual erosion of a spallation target vessel were previously not available. Recently, the erosion damage to multiple target vessels operated at the Spallation Neutron Source was measured using a high-resolution laser scanning system, which provided an opportunity to study the efficacy of a cavitation damage progression model. In this paper, a cavitation progression modeling procedure developed using empirical observations is compared to measurements of samples from target vessels after operation. We discuss the strengths and limitations of the technique and propose methods for improving future modeling and predictive accuracy.

36 MATERIALS SCIENCE↗

Oak Ridge National Laboratory Official TM Cover: Development and Qualification of Tungsten Reference Materials for LA-ICP-MS

Reference materials have been developed to provide areal density measurements of tungsten that is deposited on graphite when using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Several reference materials of varying areal densities have been produced using a magnetron sputtering, thin film deposition technique. With multiple reference materials that have varying areal densities, a calibration curve has been developed for translating the detector response of an ICP-MS into a quantitative measurement. These results provide the opportunity to make calibrated comparisons across graphite samples that were exposed to tungsten transport experiments for nuclear fusion research. In addition, these methods may be applied to provide individual areal density measurements for the five unique isotopes of tungsten. It is found that areal density measurements via LA-ICP-MS agree with characterization for the same samples when using the more traditional Rutherford backscattering ion beam technique. Qualification of these reference materials was completed using ion beam laboratories at the University of Tennessee, Knoxville and Massachusetts Institute of Technology, and Sandia National Laboratory.

36 MATERIALS SCIENCE↗

A Focused Ion Beam-Scanning Transmission Electron Microscopy with Energy-Dispersive X-ray Spectroscopy Study on Technetium Incorporation within Iron Oxides through Fe(OH) 2 (s) Mineral Transformation

Incorporation of Tc(IV) into iron oxide/hydroxide minerals has been explored and proposed as a promising pathway to preventing Tc(IV) reoxidation to environmentally mobile pertechnetate (TcO 4 - ) and improving long-term immobilization of radioactive technetium-99 (Tc). However, visual evidence evaluating the distribution of Tc(IV) incorporated within iron oxide/hydroxide phases has not been available, until now, despite potential implications on Tc(IV) stability within the host phase. For the purpose of this study Tc(IV) incorporation into iron oxide/hydroxide phases was facilitated via Fe(OH) 2 (s) oxidation and mineral transformation to magnetite (Fe 3 O 4 ). Focused ion beam - scanning transmission electron microscopy equipped with energy-dispersive X-ray spectroscopy (FIB/STEM-EDS) methods were then combined with X-ray diffraction and absorption spectroscopy techniques to characterize and visually demonstrate that, for the first time, Tc(IV) is heterogeneously incorporated into different iron oxide/hydroxide phases as Tc(IV)-incorporated magnetite and/or TcO 2 ·2H 2 O(s) via different incorporation mechanisms. Heterogeneous distribution of Tc(IV) in magnetite suggests either (i) TcO4- is reduced quickly at the magnetite surface and then encapsulated into magnetite during continued octahedral crystal growth, or (ii) Tc(IV) alternatively partitioned into multiple layers of a blocky, plate-like morphological magnetite structure showing stratified Tc. With limited Tc-hematite (Fe 2 O 3 ) incorporation, the results suggest that TcO 2 ·2H 2 O(s) is formed and mainly associated/embedded in fibrous nanometer-sized polycrystalline hematite. This work highlights the power of modern state-of-the-art FIB/STEM-EDS approach to provide essential visual insights of the Tc-iron oxide/hydroxide incorporation and generate reliable mechanism-informed designs for waste forms relying on Tc mineral incorporation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of rotation on negative triangularity plasmas in DIII-D

At the DIII-D tokamak, plasmas with negative triangularity (NT) have been found to have similar energy confinement times as H-mode plasmas with positive triangularity. These NT plasmas also have a stable edge that inhibits H-mode, lacks dangerous edge transients, and has naturally low impurity confinement. For these reasons, NT plasmas have the potential to be a transformative reactor scenario. To determine the importance of strong co-current neutral beam torque for NT performance at DIII-D, scans of neutral beam torque at constant neutral beam power have been performed. These scans have shown that the energy confinement time for a basic, inductive NT scenario (q 95 ≈ 2.8) decreases by 16% when torque is reduced to reactor levels. This reduction in confinement can be replicated with gyrofluid modeling that isolates the role of E x B shear in the change in transport. In a separate set of discharges with lower plasma current (q 95 ≈ 2.5), no significant correlation between confinement time and rotation was found. Throughout this investigation, excellent MHD stability was observed, even with very low toroidal rotation. Further, low impurity confinement was found at multiple rotation levels. Throughout the campaign, rotation near the edge was counter-current, consistent with the measurement of counter-current intrinsic edge rotation, and these observations agree with NT results from the TCV tokamak.

confinement↗

Dual-Baseline Search for Active-to-Sterile Neutrino Oscillations in NOvA

We report a search for neutrino oscillations to sterile neutrinos under a model with three active and one sterile neutrinos (3+1 model). This analysis uses the NOvA detectors exposed to the NuMI beam, running in neutrino mode. The data exposure, 13.6 × 10 20 protons on target, doubles that previously analyzed by NOvA, and the analysis is the first to use 𝜈 𝜇 charged-current interactions in conjunction with neutral-current interactions. Neutrino samples in the near and far detectors are fitted simultaneously, enabling the search to be carried out over a Δ⁢𝑚$^{2}_{41}$ range extending 2 (3) orders of magnitude above (below) 1 eV 2 . NOvA finds no evidence for active-to-sterile neutrino oscillations under the 3+1 model at 90% confidence level. New limits are reported in multiple regions of parameter space, excluding some regions currently allowed by IceCube at 90% confidence level. We additionally set the most stringent limits for anomalous 𝜈 𝜏 appearance for Δ⁢𝑚$^{2}_{41}$ ≤ 3 eV 2 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanoparticle-enabled increase of energy efficiency during laser metal additive manufacturing

The low energy efficiency of the laser metal additive manufacturing (AM) process is a potential sustainability concern for large-scale industrial production. Explicit investigation of the energy efficiency for laser melting requires the direct characterization of melt pool dimension and vapor depression, which is very difficult due to the opaque nature of the molten metal. Here we report the direct observation and quantification of effects of the TiC nanoparticles on the vapor depression and melt pool formation during laser powder bed fusion (LPBF) of Al6061 by in-situ high-speed high-energy x-ray imaging. Based on the quantification results, we calculated the laser melting energy efficiency (defined here as the ratio of the energy needed to melt the material to the energy delivered by the laser beam) with and without TiC nanoparticles during LPBF of Al6061. Here the results show that adding TiC nanoparticles into Al6061 leads to a significant increase of laser melting energy efficiency (114% increase on average, 521% increase under 312 W laser power, 0.4 m/s scan speed). Systematic property measurement, simulation, and x-ray imaging studies enable us, for the first time, to identify that three mechanisms work together to enhance the laser melting energy efficiency: (1) adding TiC nanoparticles increases the absorptivity; (2) adding TiC nanoparticles decreases the thermal conductivity, and (3) adding TiC nanoparticles enables the initiation of vapor depression and multiple reflection at lower laser power (i.e., lowers the laser power threshold for keyholing). The method and mechanisms of using TiC nanoparticles to increase the laser melting energy efficiency during LPBF of Al6061 we reported here may guide the development of feedstock materials for more energy efficient laser metal AM.

36 MATERIALS SCIENCE↗

Targeted Alpha Particle Therapy Remodels the Tumor Microenvironment and Improves Efficacy of Immunotherapy

The tumor microenvironment (TME) can severely impair immunotherapy efficacy by repressing the immune system. In a multiple myeloma (MM) murine model, we investigated the impact of targeted alpha particle therapy (TAT) on the immune TME. TAT was combined with an adoptive cell transfer of CD8 T cells (ACT), and the mechanisms of action of this combination were assessed at the tumor site.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final report on assessment of molten salt corrosion testing of unirradiated and ion irradiated advanced manufactured high entropy alloys

Generation IV reactors and future fusion reactor designs have led to more demanding materials performance requirements due to their increased operating temperatures, corrosive coolants, and increased radiation doses compared to the current light-water reactor fleet. Among the innovative nuclear technologies under development, molten salt reactors stand out for their potential to offer superior fuel utilization, intrinsic safety characteristics, and economic viability. Of the proposed Generation IV designs, the gas fast reactor operates at 450 to 850°C and the molten salt reactor operates at 565 to 850°C, with the molten salt reactor design needing molten salt corrosion resistant materials [1, 2]. These increased temperatures and more extreme corrosion environments necessitate higher material performance, such as creep strength, radiation-tolerant microstructures, corrosion resistance, and high-temperature tensile properties. Hastelloy-N, a nickel-based alloy with additions of molybdenum and chromium, has been successfully employed to contain molten fluoride salt at temperatures up to 705°C. However, Hastelloy-N becomes embrittled upon neutron irradiation, primarily due to the accumulation of helium produced by (n,a) transmutation reactions. Furthermore, the corrosive nature of molten fluoride and chloride salts presents a formidable challenge, as these salts can react with and dissolve alloying elements such as Cr, Mo, and Fe, leading to selective leaching, loss of protective oxide layers, and accelerated degradation. High entropy alloys (HEAs) and refractory high entropy alloys (RHEAs) have emerged as a prominent area of interest, due to their ability to achieve tailored chemical compositions for specific applications. Unlike conventional alloys, HEAs are characterized by having multiple principal elements in equimolar or near equimolar ratios, leading to an unconventional alloying strategy [3]. This alloying strategy is believed to promote unique properties, such as single-phase stabilization of chemically compatible elements, lattice distortion effects due to atomic radius differences, and proposed sluggish diffusion effects. For extreme-environment applications, RHEAs have garnered much research interest because of the possibility of creating relatively ductile materials that can operate in extremely high-temperature environments, beyond the operating temperatures where other Ni-based superalloys begin to lose strength [4-6]. Idaho National Laboratory (INL) initiated a joint international effort with the Czech Republic to explore the feasibility of manufacturing HEAs for high-temperature nuclear applications using advanced manufacturing. This effort was funded at INL by the United States Department of Energy's Office of Nuclear Energy under the Advanced Reactor Technologies and Advanced Materials and Manufacturing Technologies (AMMT) Program. The HEAs were specifically designed for the corrosive and irradiation environments experienced in gas-cooled fast reactors, molten salt reactors, and fusion power. These alloys have been manufactured by multiple processes to determine the impact of manufacturing processes on the performance of the alloys in corrosive and irradiation environments. Preliminary molten salt corrosion testing showed that equimolar MoNbTiV and MoNbTi alloys exhibit exceptional performance, with arc-melted variants demonstrating only minimal degradation after 1000 hours of exposure to molten chloride salt at 700°C. Conversely, Nb2TiVZr2 showed significant molten salt corrosion susceptibility and microstructural instability during high-temperature molten salt exposures, and was, therefore deemed unfit for molten salt reactor applications. The MoNbTiV, MoNbTi, and Nb2TiVZr2 alloys were further evaluated through ion irradiation experiments conducted at the Michigan Ion Beam Laboratory at the University of Michigan. The microstructural stability and the evolution of irradiation-induced defects were characterized to assess the irradiation resistance of each of these alloys.

36 - MATERIALS SCIENCE↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

Performance of a triple-GEM detector with capacitive-sharing 3-coordinate (X–Y–U)-strip anode readout

The concept of capacitive-sharing readout, described in detail in a previous study, offers the possibility for the development of high-performance three-coordinates (X--Y--U)-strip readout for Micro Pattern Gaseous Detectors (MPGDs) using simple standard PCB fabrication techniques. Capacitive-sharing (X--Y--U)-strip readout allows simultaneous measurement of the Cartesian coordinates x and y of the position of the particles together with a third coordinate u along the diagonal axis in a single readout PCB. This provides a powerful tool to address multiple-hit ambiguity and enable pattern recognition capabilities in moderate particle flux environment of collider or fixed target experiments in high energy physics HEP) and nuclear physics (NP). We present in this paper the performance of a 10 cm × 10 cm triple-GEM detector with capacitive-sharing (X--Y--U)-strip anode readout. Spatial resolutions of the order of $\sigma_{x}^{res}$ = 71.6 $\pm$ 0.8 $\mu$m for X-strips, $\sigma_{y}^{res}$ = 56.2 $\pm$ 0.9 $\mu$m for Y-strips and $\sigma_{u}^{res}$ = 75.2 $\pm$ 0.9 $\mu$m for U-strips have been obtained at a beam test at Thomas Jefferson National Accelerator Facility (Jefferson Lab). Modifications of the readout design of future prototypes to improve the spatial resolution and challenges in scaling to large-area MPGDs are discussed.

(X-Y-U) strip↗