Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Electron cyclotron emission measurements and modeling in optically semi-transparent plasma on the HSX stellarator

On the Helically Symmetric Experiment (HSX), electron cyclotron emission (ECE) at the second harmonic of the electron gyrofrequency is measured with a 16-channel heterodyne receiver. An ECE radiometer diagnostic has been calibrated with a broadband frequency source, allowing independent measurements of the electron temperature. The antenna pattern has a significant impact on the measurements, and modeling its effect is necessary to produce an ECE radiation temperature spectrum. Measurements, calibration results, and modeling of the ECE data are presented in this paper. At a relatively high plasma density, HSX plasmas are thermal, and the radiation temperature measured by the radiometer is in good agreement with the electron temperature measured by a Thomson scattering diagnostic. At a relatively low plasma density, the deviation from a Maxwellian distribution is large, and asymmetry in the radiation temperature profile is measured. These measurements are supported by single-pass and multi-pass ray tracing calculations of the electron cyclotron emission using the TRAVIS ray tracing code. Thermal and nonthermal electron populations exist in HSX, and the effect of these populations on the asymmetry in the measured emission is presented.

Cyclotron radiation↗

Measurement of a radial flow profile with eddy current flow meters and deep neural networks

Eddy current flow meters (ECFMs) measure flows of conductive fluids. Recent interest in ECFMs has increased due to applications in advanced nuclear reactors. ECFMs are well suited for such applications, as they can provide non-invasive measurements of flow in fluids that are often difficult to measure. Traditionally, ECFMs are operated using an alternating current at a single frequency, limiting ECFMs to measure average fluid velocities, blockages, or voids. Here, we expand the capabilities of ECFMs by measuring the fluid radial velocity profile of liquid mercury. To accomplish this, we made several ECFM sensitivity measurements at a range of frequencies. Different frequencies vary the electromagnetic skin depth of the device. By adjusting frequencies, we probed the fluid velocity at various radial locations and constructed a flow-velocity profile. The relationship between the ECFM measurements and velocity profile is nonlinear and requires solving an inverse problem. Using electromagnetic finite-element simulations to train a deep neural network (DNN), we created a model that provides a stable general relationship between the sensitivity measurements of an ECFM and the fluid velocity profile. Using ECFM measurements of liquid mercury, our DNN model calculates a flow profile that agrees well with computational fluid dynamics (CFD) simulations. This technique has potential to improve flow monitoring for optimization, safe operation of conductive fluid loops, and/or validating complex CFD models.

47 OTHER INSTRUMENTATION↗

Model-based approach to investigate equipment-induced error in pressure-waveform derived hemodynamic measurements

Advanced hemodynamic monitoring systems have provided less invasive methods for estimating pressure-derived measurements such as pressure-derived cardiac output (CO) measurements. These devices apply algorithms to arterial pressure waveforms recorded via pressure recording components that transmit the pressure signal to a pressure monitor. While standards have been developed for pressure monitoring equipment, it is unclear how the equipment-induced error can affect secondary measurements from pressure waveforms. We propose an approach for modelling different components of a pressure monitoring system and use this model-based approach to investigate the effect of different pressure recording configurations on pressure-derived hemodynamic measurements. The proposed model-based approach is a three-step process. (1) Modelling the response of pressure recording components using bench tests; (2) verifying the identified models through nonparametric equivalence tests; and (3) assessing the effects of pressure recording components on pressure-derived measurements. To delineate the application of this approach, we performed a series of model-based analyses to quantify the combined effect of a wide range of tubing configurations with various damping ratios and natural frequencies and monitors with different bandwidths on pressure waveforms and CO measurements by six pulse contour algorithms. Model-based results show the error in pressure-derived CO measurements because of tubing configurations with different natural frequencies and damping ratios. Tubing configurations with low natural frequencies (<23 Hz) altered characteristics of pressure waveforms in a way that affected the CO measurement, some by as much as 20%. Our method can serve as a tool to quantify the performance of pressure recording systems with different dynamic properties. In conclusion, this approach can be applied to investigate the effects of physiologic signal recording configurations on various pressure-derived hemodynamic measurements.

42 ENGINEERING↗

A sound horizon-free measurement of H 0 in DESI 2024

The physical size of the sound horizon at recombination is a powerful source of information for early-time measurements of the Hubble constant H 0 , and many proposed solutions to the Hubble tension therefore involve modifications to this scale. In light of this, there has been growing interest in measuring H 0 independently of the sound horizon. We present the first such measurement to use data from the Dark Energy Spectroscopic Instrument (DESI), jointly analyzing the full-shape galaxy power spectra of DESI luminous red galaxies, emission line galaxies, quasars, and the bright galaxy sample, in a total of six redshift bins. Information from the sound horizon scale is removed from our constraints via a rescaling procedure at the power spectrum level, with our sound horizon-marginalized measurement being driven instead primarily by the matter-radiation equality scale. This measurement is then combined with additional sound horizon-free information from Planck+ACT CMB lensing, uncalibrated type Ia supernovae, and the DESI Lyman-α forest. We agnostically combine with the DESY5, Pantheon+, and Union3 supernova datasets, with our tightest respective constraints being H 0 = 66.7 +1.7 -1.9 , 67.9 +1.9 -2.1 , and 67.8 +2.0 -2.2 km s -1 Mpc -1 . This corresponds to a sub-3% sound horizon-free constraint of the Hubble constant, and is the most precise measurement of its kind to date. Even without including information from the sound horizon, our measurement is still in 2.2-3.0σ tension with SH0ES. Additionally, the consistency between our result and other measurements that do rely on the sound horizon scale provides no evidence for new early-Universe physics (e.g. early dark energy). Future DESI data releases will allow unprecedented measurements of H 0 and place strong constraints on models that use beyond-ΛCDM physics to ameliorate the Hubble tension.

79 ASTRONOMY AND ASTROPHYSICS↗

DESI DR1 Ly α 1D power spectrum: the Fast Fourier Transform estimator measurement

Here, we present the one-dimensional Lyman-α forest power spectrum measurement derived from the data release 1 (DR1) of the Dark Energy Spectroscopic Instrument (DESI). The measurement of the Lyman-α forest power spectrum along the line of sight from high-redshift quasar spectra provides information on the shape of the linear matter power spectrum, neutrino masses, and the properties of dark matter. In this work, we use a Fast Fourier Transform (FFT)-based estimator, which is validated on synthetic data in a companion paper. Compared to the FFT measurement performed on the DESI early data release, we improve the noise characterization with a cross-exposure estimator and test the robustness of our measurement using various data splits. We also refine the estimation of the uncertainties and now present an estimator for the covariance matrix of the measurement. Furthermore, we compare our results to previous high-resolution and eBOSS measurements. In another companion paper, we present the same DR1 measurement using the Quadratic Maximum Likelihood Estimator (QMLE). These two measurements are consistent with each other and constitute the most precise one-dimensional power spectrum measurement to date, while being in good agreement with results from the DESI early data release.

Lyman alpha forest↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. In this work, the new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of the suppression and correlations of dijets in Pb+Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

Studies of the correlations of the two highest transverse momentum (leading) jets in individual Pb+Pb collision events can provide information about the mechanism of jet quenching by the hot and dense matter created in such collisions. In Pb+Pb and $pp$ collisions at $\sqrt{s_{NN}}$ = 5.02 TeV, measurements of the leading dijet transverse momentum ($p_T$) correlations are presented. Additionally, measurements in Pb+Pb collisions of the dijet pair nuclear modification factors projected along leading and subleading jet $p_T$ are made. The measurements are performed using the ATLAS detector at the LHC with 260 pb –1 of pp data collected in 2017 and 2.2 nb –1 of Pb+Pb data collected in 2015 and 2018. An unfolding procedure is applied to the two-dimensional leading and subleading jet $p_T$ distributions to account for experimental effects in the measurement of both jets. Results are provided for dijets with leading jet $p_T$ greater than 100 GeV. Measurements of the dijet-yield-normalized $x_{J}$ distributions in Pb+Pb collisions show an increased fraction of imbalanced jets compared to pp collisions; these measurements are in agreement with previous measurements of the same quantity at 2.76 TeV in the overlapping kinematic range. Measurements of the absolutely normalized dijet rate in Pb+Pb and pp collisions are also presented, and show that balanced dijets are significantly more suppressed than imbalanced dijets in Pb+Pb collisions. It is observed in the measurements of the pair nuclear modification factors that the subleading jets are significantly suppressed relative to leading jets with $p_T$ between 100 and 316 GeV for all centralities in Pb+Pb collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Entanglement Capacity Estimates and Throughput Measurements of Quantum Channels

The throughput is an important performance metric of entangled qubit distribution quantum networks, and may be characterized by the number of distributed entangled qubit pairs per second (ebps). It is measured over physical quantum network connections using specialized instruments, including photonic entanglement sources and single photon detectors. Extensive theory has been developed to estimate the entangled qubit capacity of quantum channels using abstractions of physical connections. These two quantities both characterize the throughput performance but in different ways, and typically have been hard to relate to each other in concrete terms, in part due to the lack of precise measurements with matching analytical models and derivations. We describe measurements on a physical testbed with fiber connections of lengths 0-75 kilometers. We obtain the normalized analytic capacity estimates using the transmissivity approximations derived using single photon coincidence measurements, and convert them to bounds on throughput (measured in ebps) using a multiplier derived from co-located detector measurements. The results indicate consistent throughput measurements upper-bounded by their analytical capacity estimates across all connections. We show that previous capacity estimates using light measurements are below ebps measurements for some connections, due to the inclusion of non-representative decrease of light levels outside C-band with distance.

Rao, Nageswara↗

Measurement of the inclusive isolated-photon production cross section in pp collisions at $\mathbf {\sqrt{\textit{s}}=13}$ TeV

The production cross section of inclusive isolated photons has been measured by the ALICE experiment at the CERN LHC in pp collisions at centre-of-momentum energy of $\mathbf {\sqrt{\textit{s}}=13}$ TeV collected during the LHC Run 2 data-taking period. The measurement is performed by combining the measurements of the electromagnetic calorimeter EMCal and the central tracking detectors ITS and TPC, covering a pseudorapidity range of and a transverse momentum range of |η γ | < 0.67 and a transverse momentum range 7 < p$^{γ}_{T}$ < 200 GeV/c. The result extends to lower p$^{γ}_{T}$ and x$^{γ}_{T}$ = 2p$^{γ}_{T}$/$\sqrt{s}$ ranges, the lowest x$^{γ}_{T}$ of any isolated photon measurements to date, extending significantly those measured by the ATLAS and CMS experiments towards lower p$^{γ}_{T}$ at the same collision energy with a small overlap between the measurements. The measurement is compared with next-to-leading order perturbative QCD calculations and the results from the ATLAS and CMS experiments as well as with measurements at other collision energies. The measurement and theory prediction are in agreement with each other within the experimental and theoretical uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

Analysis with the ORIGEN Module of PNAR Spent Fuel Measurements for Nuclear Safeguards Applications

This report documents the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements for 23 boiling water reactor spent fuel assemblies that were performed in Finland under Action Sheet 65, which is an international collaboration on spent fuel safeguards verification methods in the context of the Finnish spent fuel encapsulation/repository system. PNAR measures the passive neutron and gamma emission rates from each of the spent fuel assemblies like a Fork detector, and it also measures the PNAR ratio, which is expected to correlate with the net neutron multiplication of the measured fuel assembly. The analysis was performed with the Oak Ridge Isotope Generation and Depletion (ORIGEN) Data Analysis Module, which was originally developed for predicting Fork detector spent fuel measurement signals in real time and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the International Atomic Energy Agency. The module includes the ORIGEN burnup analysis code and integrates detector response functions pregenerated using the MCNP Monte Carlo transport code to predict the detector signals in several seconds per assembly. In this study, new response functions specific to the analyzed PNAR measurements were generated for the ORIGEN Module. The study also analyzes the impact of using detailed fuel design and operation information vs. standard safeguards information on the results calculated with the ORIGEN Module. Using detailed information reduced the standard deviation of the relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. An uncertainty assessment of the calculations was also performed to estimate the potential impact of the accuracy and the completeness of declaration information on the calculated results for the count rates and net neutron multiplications. The ORIGEN Module predictions for PNAR signals and net neutron multiplication are expected to directly support the safeguards inspectors’ efforts to verify operator declarations of a spent fuel assembly in real time in safeguards practices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Spectrum and 10B(n,α) Measurements in ZPPR-15

Neutron spectra were measured at the core center with proton recoil spectrometers in ZPPR15A loading 66, ZPPR-15B loading 90 and ZPPR loading 186. In addition, neutron spectra were measured in the SSNA shield configuration in ZPPR-15B loading 121 and in the BCNA shield configuration in ZPPR-15B loading 126. The ZPPR-15 neutron spectrum measurement and data processing techniques were described and analyzed. Total uncertainties were derived for all five spectrum measurements. A back-to-back proportional counter was used to measure the 10 B(n,α) reaction rate at six locations in the simulated shield, radial reflector and outer core in the ZPPR-15B BCNA shield experiment. The measurements were described and analyzed. A total uncertainty was derived for the 10 B(n,α) reaction rate measurements. The ZPPR-15 experimental records were used to develop detailed as-built Monte Carlo models for the five neutron spectrum measurement configurations and for the six 10 B(n,α) measurement configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magnetogravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Smart System for the Contactless Measurement of Energy Expenditure

Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO 2 production, VCO 2 (mL/min), and/or O 2 consumption, VO 2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO 2 from a room’s ambient CO 2 concentration transients was evaluated. Resting EE (REE) and exercise VCO 2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO 2 and λ for CO 2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO 2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).

47 OTHER INSTRUMENTATION↗

Probing the Environment around GW170817 with DESI: Insights on Galaxy Group Peculiar Velocities for Standard Siren Measurements

We present a new measurement of the Hubble constant, H 0 , following the gravitational-wave event GW170817 and Dark Energy Spectroscopic Instrument (DESI) observations. A standard siren measurement with a nearby (luminosity distance ∼40 Mpc) event such as GW170817 is typically sensitive to the peculiar motion of the host galaxy owing to local dynamics. Previous measurements from this event have taken advantage of peculiar velocity measurements of nearby galaxies, including a handful of objects in the galaxy group that the host of the event, NGC 4993, has been associated with. Still, the group’s properties and NGC 4993’s membership were debated. We present DESI observations of thousands of galaxies in the vicinity of NGC 4993, resulting in 39 group galaxies and a fivefold increase in galaxies compared to previous observations, with many contributing to a peculiar velocity measurement. Examining the local dynamics, our observations support the presence of a galaxy group of which NGC 4993 is a part with a halo mass of order ∼10 13 M ⊙ . Using peculiar velocity measurements from our fundamental plane galaxy observations, we find $H_0 = 70.9^{+6.4}_{-8.5}$ km s −1 Mpc −1 . In addition, using a peculiar velocity measurement for NGC 4993 from surface brightness fluctuations in Cosmicflows-4, we find $H_0 = 73.4^{+3.3}_{-3.9}$ km s −1 Mpc −1 . We study the impact of different galaxy selection criteria on the determination of the peculiar velocity and, in turn, on the H 0 measurement. Our results demonstrate the value of multiplexed spectroscopic observations for probing the local environments of gravitational-wave events used in standard siren measurements.

Amsellem, A. J. [Carnegie Mellon University, Pitts↗

Lensing Without Borders: Measurements of galaxy-galaxy lensing and projected galaxy clustering in DESI DR1

We present Galaxy-Galaxy Lensing measurements obtained by cross-correlating spectroscopically observed galaxies from the first data release of the Dark Energy Spectroscopic Instrument (DESI) with source galaxies from the Hyper Suprime-Cam Subaru Strategic Survey, the Kilo-Degree Survey, the Sloan Digital Sky Survey, and the Dark Energy Survey. Specifically, we measure the excess surface mass density $ΔΣ$ and tangential shear $γ_\mathrm{t}$ for the Bright Galaxy Sample and Luminous Red Galaxies measured within the first year of observations with DESI. To ensure robustness, we test the measurements for systematic biases, finding no significant trends related to the properties of the \acrshort{desi} lens galaxies. We identify a significant trend with the average redshift of source galaxies, however, this trend vanishes once we apply shifts to the Hyper Suprime-Cam Subaru Strategic Survey redshift distributions that are also favored by their fiducial cosmology analysis. Additionally, we compare the observed scatter in the measurements with the theoretical covariance and find excess scatter, driven primarily by small-scale measurements of $r\leq 1 \, \mathrm{Mpc}/h$; measurements on larger scales are consistent at the $2\,σ$ level. We further present the projected clustering measurements $w_p$ of the galaxy samples in the the first data release of DESI. These measurements, which will be made publicly available, serve as a foundation for forthcoming cosmological analyses.

Heydenreich, S. [Lick Observ.] (ORCID:000000027273↗

Field intercomparison of ice nucleation measurements: the Fifth International Workshop on Ice Nucleation Phase 3 (FIN-03)

Abstract. The third phase of the Fifth International Ice Nucleation Workshop (FIN-03) was conducted at the Storm Peak Laboratory in Steamboat Springs, Colorado, in September 2015 to facilitate the intercomparison of instruments measuring ice-nucleating particles (INPs) in the field. Instruments included two online and four offline measurement systems for INPs, which are a subset of those utilized in the laboratory study that comprised the second phase of FIN (FIN-02). The composition of the total aerosols was characterized using the Particle Analysis by Laser Mass Spectrometry (PALMS) and Wideband Integrated Bioaerosol Sensor (WIBS) instruments, and aerosol size distributions were measured by a laser aerosol spectrometer (LAS). The dominant total particle compositions present during FIN-03 were composed of sulfates, organic compounds, and nitrates, as well as particles derived from biomass burning. Mineral-dust-containing particles were ubiquitous throughout and represented 67 % of supermicron particles. Total WIBS fluorescing particle concentrations for particles with diameters of > 0.5 µm were 0.04 ± 0.02 cm−3 (0.1 cm−3 highest; 0.02 cm−3 lowest), typical of the warm season in this region and representing ≈ 9 % of all particles in this size range as a campaign average. The primary focus of FIN-03 was the measurement of INP concentrations via immersion freezing at temperatures > −33 °C. Additionally, some measurements were made in the deposition nucleation regime at these same temperatures, representing one of the first efforts to include both mechanisms within a field campaign. INP concentrations via immersion freezing agreed within factors ranging from nearly 1 to 5 times on average between matched (time and temperature) measurements, and disagreements only rarely exceeded 1 order of magnitude for sampling times coordinated to within 3 h. Comparisons were restricted to temperatures lower than −15 °C due to the limits of detection related to sample volumes and very low INP concentrations. Outliers of up to 2 orders of magnitude occurred between −25 and −18 °C; a better agreement was seen at higher and lower temperatures. Although the 5–10 factor agreement of INP measurements found in FIN-03 aligned with the results of the FIN-02 laboratory comparison phase, giving confidence in progress of this measurement field, this level of agreement still equates to temperature uncertainties of 3.5 to 5 °C that may not be sufficient for numerical cloud modeling applications that utilize INP information. INP activity in the immersion-freezing mode was generally found to be an order of magnitude or more, making it more efficient than in the deposition regime at 95 %–99 % water relative humidity, although this limited data set should be augmented in future efforts. To contextualize the study results, an assessment was made of the composition of INPs during the late-summer to early-fall period of this study inferred through comparison to existing ice nucleation parameterizations and through measurement of the influence of thermal and organic carbon digestion treatments on immersion-freezing ice nucleation activity. Consistent with other studies in continental regions, biological INPs dominated at temperatures of > −20 °C and sometimes colder, while arable dust-like or other organic-influenced INPs were inferred to dominate below −20 °C.

54 ENVIRONMENTAL SCIENCES↗