At least 631 records · Page 35

Aluminum cladding oxide growth prediction for high flux research reactors

Aluminum cladding oxidation of research-reactor fuel elements at high power conditions has a disadvantageous effect on fuel performance due to the lower thermal conductivity of the oxide. The oxide growth prediction models available in the literature were mostly developed for low power conditions. To examine the applicability of the models to high power and high temperature test conditions, the models were studied by coupling with the most frequently employed heat transfer coefficient (HTC) correlations including the Dittus-Boelter correlation, the Colburn correlation, the Sieder-Tate correlation, and KAERI-developed correlation. The Griess model over-predicted the oxide growth while the KAERI-Griess model under-predicted the oxide growth for high power tests. The Kim model, coupled with the Colburn correlation, gave most consistent results with the measured data from two BR2 experiments. However, the Kim model was found to be inapplicable to the EUHFRR conditions at the peak power locations if it was coupled with the Dittus-Boelter correlation. A revision of the prediction models to more closely agree with the measured data was recommended. Furthermore, AG3NE and AlFeNi cladding types were tested in the E-FUTURE experiment, and a noticeable (although small) reduction in oxide thickness on the AlFeNi cladding was observed. However, this difference was believed to be only a secondary effect considering other uncertainties in model predictions, so no attempt was made to model the alloying effect.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantifying and Qualifying Alloys Based on Level of Homogenization: A U–10 wt% Mo Alloy Case Study

Homogenization heat treatment is performed to attain uniformity in microstructure of metals and metal alloys, which is helpful to achieve the desired workability and microstructure in final products, and eventually to gain predictable and consistent performance. Fabrication of fuel plates made from a low-enriched uranium alloy with 10 wt% Mo (U-10Mo) involves multiple thermomechanical processing steps. It is well known that the molybdenum homogeneity in the final formed product affects the fuel performance in the nuclear reactor. To make sure these materials are uniformly homogenized, a statistical method was proposed to quantify and characterize the Mo concentration variation in U-10Mo fuel plates by analyzing the Mo concentration measurement data from scanning electron microscopy–energy dispersive spectroscopy line scans. Statistical tolerance intervals were employed to determine the qualification of U-10Mo fuel plates. We formulate an argument for the minimum number of independent samples required to define fuel plate qualification if no Mo measurement data are available in advance, and demonstrate that the given tolerance interval requirements can be equivalently reduced to a sample variance criterion in this application. The outcome of the statistical analysis can be used to optimize casting design and eventually increase productivity and reduce fabrication cost. The statistical strategy developed in this report can be implemented for other applications, especially in the field of material manufacturing to assess qualification requirements and monitor and improve process design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Observed and Modelled Aerosol Lifetimes Using Radioactive Tracers of Opportunity and an Ensemble of 19 Global Models

Aerosols have important impacts on air quality and climate, but the processes affecting their removal from the atmosphere are not fully understood and are poorly constrained by observations. This makes modelled aerosol lifetimes uncertain. In this study, we make use of an observational constraint on aerosol lifetimes provided by radionuclide measurements and investigate the causes of differences within a set of global models. During the Fukushima Dai-Ichi nuclear power plant accident of March 2011, the radioactive isotopes cesium-137 (Cs-137) and xenon-133 (Xe-133) were released in large quantities. Cesium attached to particles in the ambient air, approximately according to their available aerosol surface area. Cs-137 size distribution measurements taken close to the power plant suggested that accumulation mode (AM) sulfate aerosols were the main carriers of cesium. Hence, Cs-137 can be used as a proxy tracer for the AM sulfate aerosol's fate in the atmosphere. In contrast, the noble gas Xe-133 behaves almost like a passive transport tracer. Global surface measurements of the two radioactive isotopes taken over several months after the release allow the derivation of a lifetime of the carrier aerosol. We compare this to the lifetimes simulated by 19 different atmospheric transport models initialized with identical emissions of Cs-137that were assigned to an aerosol tracer with each model's default properties of AM sulfate, and Xe-133 emissions that were assigned to a passive tracer. We investigate to what extent the modelled sulfate tracer can reproduce the measurements, especially with respect to the observed loss of aerosol mass with time. Modelled Cs-137and Xe-133 concentrations sampled at the same location and times as station measurements allow a direct comparison between measured and modelled aerosol lifetime. The e-folding lifetime e, calculated from station measurement data taken between 2 and 9 weeks after the start of the emissions, is 14.3 days (95% confidence interval 13.1-15.7 days). The equivalent modelled e lifetimes have a large spread, varying between 4.8 and 26.7 days with a model median of 9.42.3 days, indicating too fast a removal in most models. Because sufficient measurement data were only available from about 2 weeks after the release, the estimated lifetimes apply to aerosols that have undergone long-range transport, i.e. not for freshly emitted aerosol. However, modelled instantaneous lifetimes show that the initial removal in the first 2 weeks was quicker (lifetimes between 1 and 5 days) due to the emissions occurring at low altitudes and co-location of the fresh plume with strong precipitation. Deviations between measured and modelled aerosol lifetimes are largest for the northernmost stations and at later time periods, suggesting that models do not transport enough of the aerosol towards the Arctic. The models underestimate passive tracer (Xe-133) concentrations in the Arctic as well but to a smaller extent than for the aerosol (Cs-137) tracer. This indicates that in addition to too fast an aerosol removal in the models, errors in simulated atmospheric transport towards the Arctic in most models also contribute to the underestimation of the Arctic aerosol concentrations.

Radioactive isotopes↗

A COMPARISON OF GADRAS SIMULATED AND MEASURED GAMMA RAY SPECTRA

Gamma-ray radiation detection systems are continuously being developed and improved for detecting the presence of radioactive material and for identifying isotopes present. Gamma-ray spectra, from many different isotopes and in different types and thicknesses of attenuation material and matrixes, are needed to evaluate the performance of these devices. Recently, a test and evaluation exercise was performed by the Savannah River National Laboratory that required a large number of gamma-ray spectra. Simulated spectra were used for a major portion of the testing in order to provide a pool of data large enough for the results to be statistically significant. The test data set was comprised of two types of data, measured and simulated. The measured data were acquired with a hand-held Radioisotope Identification Device (RIID) and simulated spectra were created using Gamma Detector Response and Analysis Software (GADRAS, Mitchell and Mattingly, Sandia National Laboratory). GADRAS uses a one-dimensional discrete ordinate calculation to simulate gamma-ray spectra. The measured and simulated spectra have been analyzed and compared. This paper will discuss the results of the comparison and offer explanations for spectral differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculations of separated 3-D flows with a pressure-staggered Navier-Stokes equations solver

A Navier-Stokes equations solver based on a pressure correction method with a pressure-staggered mesh and calculations of separated three-dimensional flows are presented. It is shown that the velocity pressure decoupling, which occurs when various pressure correction algorithms are used for pressure-staggered meshes, is caused by the ill-conditioned discrete pressure correction equation. The use of a partial differential equation for the incremental pressure eliminates the velocity pressure decoupling mechanism by itself and yields accurate numerical results. Example flows considered are a three-dimensional lid driven cavity flow and a laminar flow through a 90 degree bend square duct. For the lid driven cavity flow, the present numerical results compare more favorably with the measured data than those obtained using a formally third order accurate quadratic upwind interpolation scheme. For the curved duct flow, the present numerical method yields a grid independent solution with a very small number of grid points. The calculated velocity profiles are in good agreement with the measured data.

Kim, S.-W.↗

Calculations of separated 3-D flows with a pressure-staggered Navier-Stokes equations solver

A Navier-Stokes equations solver based on a pressure correction method with a pressure-staggered mesh and calculations of separated three-dimensional flows are presented. It is shown that the velocity pressure decoupling, which occurs when various pressure correction algorithms are used for pressure-staggered meshes, is caused by the ill-conditioned discrete pressure correction equation. The use of a partial differential equation for the incremental pressure eliminates the velocity pressure decoupling mechanism by itself and yields accurate numerical results. Example flows considered are a three-dimensional lid driven cavity flow and a laminar flow through a 90 degree bend square duct. For the lid driven cavity flow, the present numerical results compare more favorably with the measured data than those obtained using a formally third order accurate quadratic upwind interpolation scheme. For the curved duct flow, the present numerical method yields a grid independent solution with a very small number of grid points. The calculated velocity profiles are in good agreement with the measured data.

Kim, S.-W.↗

Flight survey of the 757 wing noise field and its effects on laminar boundary layer transition. Volume 3: Extended data analysis

A flight program was completed in June of 1985 using the Boeing 757 flight research aircraft with an NLF glove installed on the right wing just outboard of the engine. The objectives of this program were to measure noise levels on the wing and to investigate the effect of engine noise on the extent of laminar flow on the glove. Details of the flight test program and results are contained in Volume 1 of this document. Tabulations and plots of the measured data are contained in Volume 2. The present volume contains the results of additional engineering analysis of the data. The latter includes analysis of the measured noise data, a comparison of predicted and measured noise data, a boundary layer stability analysis of 21 flight data cases, and an analysis of the effect of noise on boundary layer transition.

Source record↗

Evaluation of observed and modelled aerosol lifetimes using radioactive tracers of opportunity and an ensemble of 19 global models

Aerosols have important impacts on air quality and climate, but the processes affecting their removal from the atmosphere are not fully understood and are poorly constrained by observations. This makes modelled aerosol lifetimes uncertain. In this study, we make use of an observational constraint on aerosol lifetimes provided by radionuclide measurements and investigate the causes of differences within a set of global models. During the Fukushima Dai-Ichi nuclear power plant accident of March 2011, the radioactive isotopes cesium-137 ( 137 Cs) and xenon-133 ( 133 Xe) were released in large quantities. Cesium attached to particles in the ambient air, approximately according to their available aerosol surface area. 137 Cs size distribution measurements taken close to the power plant suggested that accumulation-mode (AM) sulfate aerosols were the main carriers of cesium. Hence, 137 Cs can be used as a proxy tracer for the AM sulfate aerosol's fate in the atmosphere. In contrast, the noble gas 133 Xe behaves almost like a passive transport tracer. Global surface measurements of the two radioactive isotopes taken over several months after the release allow the derivation of a lifetime of the carrier aerosol. We compare this to the lifetimes simulated by 19 different atmospheric transport models initialized with identical emissions of 137 Cs that were assigned to an aerosol tracer with each model's default properties of AM sulfate, and 133 Xe emissions that were assigned to a passive tracer. We investigate to what extent the modelled sulfate tracer can reproduce the measurements, especially with respect to the observed loss of aerosol mass with time. Modelled 137 Cs and 133 Xe concentrations sampled at the same location and times as station measurements allow a direct comparison between measured and modelled aerosol lifetime. The e-folding lifetime τ e , calculated from station measurement data taken between 2 and 9 weeks after the start of the emissions, is 14.3 days (95 % confidence interval 13.1–15.7 days). The equivalent modelled τ e lifetimes have a large spread, varying between 4.8 and 26.7 days with a model median of 9.4 ± 2.3 days, indicating too fast a removal in most models. Because sufficient measurement data were only available from about 2 weeks after the release, the estimated lifetimes apply to aerosols that have undergone long-range transport, i.e. not for freshly emitted aerosol. However, modelled instantaneous lifetimes show that the initial removal in the first 2 weeks was quicker (lifetimes between 1 and 5 days) due to the emissions occurring at low altitudes and co-location of the fresh plume with strong precipitation. Deviations between measured and modelled aerosol lifetimes are largest for the northernmost stations and at later time periods, suggesting that models do not transport enough of the aerosol towards the Arctic. The models underestimate passive tracer ( 133 Xe) concentrations in the Arctic as well but to a smaller extent than for the aerosol ( 137 Cs) tracer. As a result, this indicates that in addition to too fast an aerosol removal in the models, errors in simulated atmospheric transport towards the Arctic in most models also contribute to the underestimation of the Arctic aerosol concentrations.

54 ENVIRONMENTAL SCIENCES↗

Quantifying and Qualifying Alloys Based on Level of Homogenization: A U-10Mo Alloy Case Study

Homogenization heat treatment is performed to attain uniformity in microstructure which is helpful to achieve the desired workability and microstructure in final products and, eventually, to gain predictive and consistent performance. Fabrication of low-enriched uranium alloys with 10 wt% molybdenum (U-10Mo) fuel plates involves multiple thermomechanical processing steps. It is well known that the molybdenum homogeneity in the final formed product affects the performance in the nuclear reactor. Here, to ensure uniform homogenization, a statistical method is proposed to quantify and characterize the molybdenum concentration variation in U-10Mo fuel plates by analyzing the molybdenum concentration measurement data from scanning electron microscopy energy dispersive spectroscopy line-scan. Statistical tolerance intervals (TI) are employed to determine the qualification of the U-10Mo fuel plate. We formulate an argument for the minimum number of independent samples to define fuel plate qualification if no molybdenum measurement data are available in advance and demonstrate that the given TI requirements can be equivalently reduced to a sample variance criterion in this application. The outcome of the statistical analysis can be used to optimize casting design and eventually increase productivity and reduce fabrication costs. The statistical strategy developed in this paper can be implemented for other applications especially in the field of material manufacturing to assess qualification requirements and monitor and improve the process design.

36 MATERIALS SCIENCE↗

Model calibration of a variable refrigerant flow system with a dedicated outdoor air system: A case study

With increased use of variable refrigerant flow (VRF) systems in the U.S. building sector, interests in capability and rationality of various building energy modeling tools to simulate VRF systems are rising. This paper presents the detailed procedures for model calibration of a VRF system with a dedicated outdoor air system (DOAS) by comparing to detailed measured data from an occupancy emulated small office building. The building energy model is first developed based on as-built drawings, and building and system characteristics available. The whole building energy modeling tool used for the study is U.S. DOE’s EnergyPlus version 8.1. The initial model is, then, calibrated with the hourly measured data from the target building and VRF-DOAS system. In a detailed calibration procedures of the VRF-DOAS, the original EnergyPlus source code is modified to enable the modeling of the specific VRF-DOAS installed in the building. After a proper calibration during cooling and heating seasons, the VRF-DOAS model can reasonably predict the performance of the actual VRF-DOAS system based on the criteria from ASHRAE Guideline 14-2014. The calibration results show that hourly CV-RMSE and NMBE would be 15.7% and 3.8%, respectively, which is deemed to be calibrated. As a result, the whole-building energy usage after calibration of the VRF-DOAS model is 1.9% (78.8 kWh) lower than that of the measurements during comparison period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Jet transport noise - A comparison of predicted and measured noise for ILS and two-segment approaches

Centerline noise measured during standard ILS and two-segment approaches in DC-8-61 aircraft were compared with noise predicted for these procedures using an existing noise prediction technique. Measured data is considered to be in good agreement with predicted data. Ninety EPNdB sideline locations were calculated from flight data obtained during two-segment approaches and were compared with predicted 90 EPNdB contours that were computed using three different models for excess ground attenuation and a contour with no correction for ground attenuation. The contour not corrected for ground attenuation was in better agreement with the measured data.

White, K. C.↗

Comparison of flight-measured and calculated temperatures on the space shuttle orbiter

Structural temperatures and thermal protection system surface temperatures were measured on the space shuttle during the flight of STS 5. The measured data are compared with values calculated at wing stations 134, 240, and 328 and at fuselage station 877. The theoretical temperatures were calculated using the structural performance and resizing finite element thermal analysis program. The comparisons show that the calculated temperatures are, generally, in good agreement with the measured data.

Gong, Leslie↗

The CIELO collaboration: Progress in international evaluations of neutron reactions on Oxygen, Iron, Uranium and Plutonium

The CIELO collaboration has studied neutron cross sections on nuclides that significantly impact criticality in nuclear technologies - 16O, 56Fe, 235;8U and 239Pu - with the aim of improving the accuracy of the data and resolving previous discrepancies in our understanding. This multi-laboratory pilot project, coordinated via the OECD/NEA Working Party on Evaluation Cooperation (WPEC) Subgroup 40 with support also from the IAEA, has motivated experimental and theoretical work and led to suites of new evaluated libraries that accurately reflect measured data and also perform well in integral simulations of criticality.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Case Study for the ARRA-Funded Ground Source Heat Pump Demonstration at Ball State University

With funding provided by the American Recovery and Reinvestment Act (ARRA), 26 ground-source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects is a district central GSHP system installed at Ball State University (BSU) in Muncie, IN. Prior to implementing the district GSHP system, 47 major buildings in BSU were served by a central steam plant with four coal-fired and three natural-gas-fired steam boilers. Cooling was provided by five water-cooled centrifugal chillers at the District Energy Station South (DESS). The new district GSHP system replaced the existing coal-fired steam boilers and conventional water-cooled chillers. It uses ground-coupled heat recovery (HR) chillers to meet the simultaneous heating and cooling demands of the campus. The actual performance of the GSHP system was analyzed based on available measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. Since Phase 1 was funded in part by the ARRA grant, it is the focus of this case study. The annual energy consumption of the GSHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. A cost analysis was performed to evaluate the simple payback of the GSHP system. The following sections summarize the results of the analysis, the lessons learned, and recommendations for improvement in the operation of this district GSHP system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SMR safety through HTTF modeling and benchmark efforts for code validation for gas-cooled reactor applications

Accurate modeling and simulation tools for thermal-hydraulics calculations are a key element needed to design and license new advanced reactors including Small Modular Reactors (SMR) and Microreactors. Uncertainties in modeling and simulation can have significant safety and economic implications. The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled prismatic-block nuclear reactors. High-quality measurement data is available from the HTTF that is suitable for a thermal-hydraulics code validation benchmark for gas-cooled reactor simulations. Here, this paper summarizes individual HTTF modeling efforts to date for tool validation at Idaho National Laboratory (INL), Argonne National Laboratory (ANL), Oregon State University (OSU) and Canadian Nuclear Laboratories (CNL) using system thermal-hydraulics codes, Computational Fluid Dynamics (CFD) codes and system-CFD code couplings. Also, the paper introduces the ongoing OECD Nuclear Energy Agency (NEA) High Temperature Gas Reactor Thermal-Hydraulics (HTGR T/H) benchmark that allows for better comparisons of results between different international modeling teams. The benchmark provides well defined computational problems that include code-to-code comparisons and comparisons to measured data. These problems provide an avenue for quantifying accuracy and identifying sources of uncertainty in thermal-hydraulics calculations, including in measured thermophysical properties, as part of validation for gas-cooled reactor simulation tools.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Building thermal model development of typical house in U.S. for virtual storage control of aggregated building loads based on limited available information

A building thermal model is an essential component for achieving optimal control of a building’s heating, ventilation, and air conditioning (HVAC). A self-learning grey-box model has been developed by implementing data-driven techniques and utilizing limited available information about the building. In previous research, detailed foreknown knowledge/information, e.g. physical and thermal properties of building materials, as well as sufficient number of observation points, e.g. indoor temperature sensors in different zones, are available for making the decision of model structure and parameters searching range easier. The availability of measured data and a narrowed searching range of model parameters, e.g. resistance and capacity for each wall, made the adopted algorithms quickly achieve near optimal values, which closely approximate the actual heat transfer of a building. Meanwhile, the details of pre-processing of the key inputs were seldom explained. Compared to the previous research, in this study, the available information is assumed to be limited which can fill the requirement for large scale virtual storage control of real residential community in near future, where it may be impractically or over time-consuming to acquire the detailed information for each single house. The developed model is validated by comparing the results to measured data in a recently-built home typical of the southeastern United States.

Cui, Borui↗

TEAMER: Water Tunnel Data from Testing the Pterofin Skimmer Concept

Pterofin's Skimmer concept relies on a flapping and pitching hydrofoil to extract hydrokinetic energy from water flows. The concept aims to utilize unsteady fluid dynamics phenomena (added mass, shed vorticity, and unsteady boundary layer development) to achieve higher lift coefficients, enabling increased power density of the hydrokinetic device and a fundamental shift in the rpm/torque scaling of the power take off compared with turbines. The Applied Research Laboratory at Penn State, in collaboration with Pterofin, designed and built a proof-of-concept flapping/pitching mechanism which was subsequently tested in ARL's 12-inch water tunnel facility. The mechanical power supplied to or extracted from the mechanism was measured for a range of hydrofoils provided by Pterofin over operating conditions including reduced frequency, Reynolds number, and the ratio between pitching and flapping amplitudes. The power lost to friction in the mechanism was removed from the net power measurement by means of a bare hub tare, with the resultant hydrodynamic power being used to calculate a mechanism-independent and non-dimensional power coefficient. The product of this effort is a dataset describing the power coefficient of a hydrofoil having simultaneous pitching and flapping motions, both of which are approximately sinusoidal. Power coefficients were collected for a range of primary design variables including: - Reduced frequency: 0.01 to 0.95 - Pitching/flapping peak angle ratio: 1.5 to 3.0 - Chord-based Reynolds number: 60,000 to 560,000 Secondary design variables relating to the hydrofoil geometry were explored including: - Aspect ratio - Planform shape - Section thickness distribution - Hydrofoil position relative to the pitching axis - Hydrofoil sweep angle relative to the pitching axis Measured data are provided in mean and time series formats. MATLAB scripts are provided which can be used to generate figures of time-averaged and phase-averaged hydrodynamic power coefficients calculated from the measured data. A complete description of the experiment and data reduction can be found in the Post Access Report for the Pterofin Skimmer test effort which will be available on the TEAMER website. This work was supported by the Pacific Energy Ocean Trust via a TEAMER award.

16 TIDAL AND WAVE POWER↗

Aircraft observations of Venus' near-infrared reflection spectrum - Implications for cloud composition

A comparison of aircraft-based measurement data on Venus' near-infrared (1.2- to 4.1-micron) reflection spectrum with computer generated spectra of a number of cloud candidates shows a 75-% or more concentrated water solution of sulfuric acid to give the only acceptable match to the profile of Venus' strong 3-micron absorption feature. However, the measurement data obtained also show a modest decline in reflectivity from 2.3-micron to 1.2-micron wavelength, which is inconsistent with the flat spectrum of sulfuric acid in this spectral region. It is hypothesized that this decline is due to impurities in the sulfuric acid droplets.

Pollack, J. B.↗