Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mathematical model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

The Implications of Collisions on the Spatial Profile of Electric Potential and the Space-Charge-Limited Current

The space-charge-limited current (SCLC) in a vacuum diode is given by the Child-Langmuir law (CLL), whose electric potential ϕ(x) ∝ (x/D) 4/3 , where x is the spatial coordinate across the gap and D is the gap separation distance. For a collisional diode, SCLC is given by the Mott-Gurney law (MGL) and ϕ(x) ∝ (x/D) 3/2 . Here, we apply a capacitance argument for SCLC and use the transit time from a recent exact solution for collisional SCLC to show that ϕ(x) ∝ (x/D)ξ for a general collisional gap, where 4/3 ≤ ξ ≤ 3/2 . Furthermore, ξ is strictly a function of νT, where ν is the collision frequency and T is the electron transit time. Using this definition of ξ, we estimate the spatial dependence of the electron velocity and use the gap capacitance to derive an analytic equation for collisional SCLC that agrees within ~4.5% of the exact solution that requires solving parametrically through T. This analytic equation for general ξ asymptotically recovers the CLL as ν → 0 and the MGL as ν → ∞. As a result, matching these limits shows that ξ ≈ 1.40 and V ∝ D 2 ν 2 at the transition from a vacuum to a collisional diode for any device condition.

Anodes↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Additionally, key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Propagation Pattern for Moment Representation of the Lattice Boltzmann Method

A propagation pattern for the moment representation of the regularized lattice Boltzmann method (LBM) in three dimensions is presented. Using effectively lossless compression, the simulation state is stored as a set of moments of the lattice Boltzmann distribution function, instead of the distribution function itself. An efficient cache-aware propagation pattern for this moment representation has the effect of substantially reducing both the storage and memory bandwidth required for LBM simulations. This article extends recent work with the moment representation by expanding the performance analysis on central processing unit (CPU) architectures, considering how boundary conditions are implemented, and demonstrating the effectiveness of the moment representation on a graphics processing unit (GPU) architecture.

42 ENGINEERING↗

Electron-Beam Corkscrew Motion in an Advanced Linear Induction Accelerator

Scorpius is a multipulse linear induction accelerator (LIA) under development for flash radiography. Because it has substantially more cells than present LIAs, higher magnetic focusing fields are needed to suppress beam breakup (BBU). Therefore, it is more susceptible to corkscrew motion of the beam, which also depends on beam energy spread and focusing magnet misalignments. For energy spread and alignment tolerances expected for Scorpius, a magnetic tune designed to suppress BBU is shown to produce corkscrew motion within the range that can be controlled through the use of steering dipoles on existing LIAs. Finally, a gap-voltage modulation scheme is shown to almost completely eliminate chromatic effects such as corkscrew.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Strategy for Forced Oscillation Suppression

Wide-area time-synchronized measurements have recently revealed troublesome forced oscillations (FOs) within modern synchronized power grids. In some cases, these FOs represent a dangerous hazard to the system. Recent research has focused on locating the source of FOs to provide operators with knowledge for mitigating their impact locally. This paper presents a complementary mitigation strategy, which is to purposely induce a second oscillation into the grid which cancels the impact of the FO. Such a strategy is complementary in that it may provide valuable time to operators attempting to locate the FOs source and to determine how to rectify it. This paper presents a suppression control strategy which modulates controllable devices to automatically cancel the impact of the FO without the need for locating the source of the original FO. The strategy is based upon tuned feedback control. In this study, the approach is demonstrated on a simulation system via modulation of inverter-based generation.

42 ENGINEERING↗

Adaptive Power Flow Approximations With Second-Order Sensitivity Insights

The power flow equations are fundamental to power system planning, analysis, and control. However, the inherent non-linearity and non-convexity of these equations present formidable obstacles in problem-solving processes. To mitigate these challenges, recent research has proposed adaptive power flow linearizations that aim to achieve accuracy over wide operating ranges. The accuracy of these approximations inherently depends on the curvature of the power flow equations within these ranges, which necessitates considering second-order sensitivities. In this paper, we leverage second-order sensitivities to both analyze and improve power flow approximations. We evaluate the curvature across broad operational ranges and subsequently utilize this information to inform the computation of various sample-based power flow approximation techniques. Additionally, we leverage second-order sensitivities to guide the development of rational approximations that yield linear constraints in optimization problems. In conclusion, this approach is extended to enhance accuracy beyond the limitations of linear functions across varied operational scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multifractal Characterization of Distribution Synchrophasors for Cybersecurity Defense of Smart Grids

“Source ID Mix” spoofing emerged as a new type of cyber-attack on Distribution Synchrophasors (DS) where adversaries have the capability to swap the source information of DS without changing the measurement values. Accurate detection of such a highly-deceptive attack is a challenging task especially when the spoofing attack happens on short fragments of DS recorded within a relatively small geographical scale. Herein this letter proposes an effective approach to detect this cyber-attack by realizing the multifractal characteristics of DS measurements. First, the multifractal cross-correlation of DS measured at multiple intra-state locations is revealed. Then the derived correlation is integrated with weighted two-dimensional multifractal surface interpolation to reconstruct quasi high-resolution signals. Finally, informative location-specific signatures are extracted from the high-resolution DS and they are integrated with advanced machine learning techniques for source authentication. Experiments using the real-life DS are performed to verify the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Continuum Description of the Role of Negative Transference Numbers on Ion Motion in Polymer Electrolytes

New experimental techniques such as electrophoretic NMR (eNMR) are emerging as powerful methods for directly measuring ion velocities in electrolytes under applied electric fields. The aim of this theoretical study is to predict the spatial- and temporal-dependence of these velocities of ions as a function of the magnitude of the applied field and salt concentration. It has recently been shown that mixtures of poly(ethylene oxide)-based (PEO) and lithium bis(trifluoromethanesulfonyl) imide (LiTFSI) electrolytes exhibit negative cation transference numbers in a certain salt concentration range. In this range, the cation motion at early times is directed to the positive electrode at all locations in the cell; ion migration dominates in this regime. As time progresses, the cation velocity in finite zones near both the electrodes changes sign. These zones grow rapidly with time, reflecting the increasing importance of diffusion, and a point in time is reached beyond which the cation velocity in the entire cell is directed toward the negative electrode. Overall, our work reveals the limited time window over which the results of eNMR can be used to determine the transference number. More importantly, it shows how to account for the effect of diffusional flux in such experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SOHIP Abel Transform and Onion Peeling Model Module

This software provides tools for analyzing and modeling physical systems using mathematical transforms and layered models. It includes (1) functions for performing the Abel transform, which is used to relate measurements of bending angles to properties such as refractive index and radius in a medium. The code can compute bending angles from input profiles and also reconstruct these profiles from observed data; (2) the functions for modeling systems with multiple layers using an onion-peeling approach, allowing users to simulate and analyze the behavior of layered materials or structures. These capabilities are useful for researchers and engineers working in fields such as optics, atmospheric science, and materials analysis, enabling them to interpret and model data from experiments or simulations relates to refraction in spherical symmetric medium.

Xu, Shuang [Lawrence Livermore National Laboratory↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data driven learning of robust nonlocal models

Nonlocal models use integral operators that embed length-scales in their definition. However, the integrands in these operators are difficult to define from the data that are typically available for a given physical system, such as laboratory mechanical property tests. In contrast, molecular dynamics (MD) does not require these integrands, but it suffers from computational limitations in the length and time scales it can address. To combine the strengths of both methods and to obtain a coarse-grained, homogenized continuum model that efficiently and accurately captures materials' behavior, we propose a learning framework to extract, from MD data, an optimal nonlocal model as a surrogate for MD displacements. Our framework guarantees that the resulting model is mathematically well-posed, physically consistent, and that it generalizes well to settings that are different from the ones used during training. The efficacy of this approach is demonstrated with several numerical tests for single layer graphene both in the case of perfect crystal and in the presence of thermal noise.

36 MATERIALS SCIENCE↗

PRIMO – The Oil & Gas Well Plugging Optimizer

This work presents PRIMO’s main capabilities and introduces the PRIMO web application, an intuitive user interface that leverages our sophisticated mathematical optimization model to rigorously optimize P&A priorities and plugging campaign efficiency. The web app simplifies user interaction, provides a powerful data management framework, and supports a broad user base (e.g., state agencies, well owners/operators, and plugging companies) to use PRIMO for decision-making. Specifically, we provide a demonstration of how to input the information on candidate wells, plugging campaign budget, user-defined priority and efficiency criteria to PRIMO. A real-world case study that consists of 1411 oil and gas wells and impact and efficiency priorities (e.g., well age, well proximity to schools/hospitals, well accessibility, distance between wells in projects) is presented to showcase PRIMO’s core capabilities: (i) ranking a candidate well population based on priorities, (ii) recommending high-impact and high-efficiency P&A projects, and (iii) assigning impact and efficiency scores to projects allowing for rigorous quantitative comparison among them.

02 PETROLEUM↗

Distributed Minimization of the Power Generation Cost in Prosumer-Based Distribution Networks: Preprint

Traditionally, electrical power was generated in big power plants. The cost of producing energy was related to the cost of fuel, e.g., carbon or gas, and by the cost of maintaining the power plants. With the advent of distributed energy resources, power can be produced directly at the edge of the electrical network by a new type of agents: the prosumers. Prosumers are entities that both consume and generate power, e.g., by means of photovoltaic panels. The cost of the power produced by prosumers is no longer related to fuel consumption since energy coming from distributed generators is essentially free. Rather, the cost is related to the remuneration that is due to the prosumers for the services they provide. The proposed control strategy minimizes the active power generation cost in the aforementioned scenario. The control scheme requires that the prosumers measure their voltage and then adjust the amount of injected power, according to a continuous time feedback control law that is indeed a projected gradient descent strategy. Simulations are provided in order to illustrate the algorithm behavior.

distributed control↗

High Speed Data Acquisition for Real Time Feedback in a Light Duty Engine Combustion-Mode Switching Application

The paper describes the integration of a high-speed data acquisition and diagnostics controller used in an advanced engine platform. The controller enables ultra-low emissions and new benchmarks of engine efficiency while running a Gasoline Compression Ignition (GCI) cycle on a 2.2L, 4-cylinder engine. The system enables real-time combustion feedback and vibration analysis in engines. The paper focuses on: (1) the development of an interpolative sampling algorithm for transposition of time acquired data to the crank angle domain using a production crank sensor (60-2 tooth wheel); (2) the control unit, high-speed data acquisition, communication rates between the dedicated data acquisition and base controller to ensure cycle-to-cycle feedback; and, (3) validation exercises using cylinder pressure measurements. Here, the study shows how the algorithm resolves cylinder pressure information over an engine cycle, validating its robustness across acquisition rates of 50 and 200 kHz, with crank angle resolutions of 0.5° and 0.1°. Results show that the 50 kHz, 0.5° hardware yield combustion phasing and torque estimates within 0.1° and 1% torque of those attained with the 200 kHz, 0.1° hardware. Finally, study shows the dedicated controller and communication speeds allow for next-cycle fuel injection correction for speeds above 5000 rpm.

42 ENGINEERING↗

Capturing Time-Varying Wake Dynamics Using Hybridized Actuator Disks in Steady-State Simulations for Improved Optimization Efficiency

When optimizing turbine blade properties, using a time varying, unsteady simulation allows for high-fidelity representations of the wake dynamics. Unfortunately these types of optimizations are prohibitively expensive in terms of computation time and memory requirements. This presentation aims to show a method of transferring the wake dynamics of an unsteady simulation to a much more computationally tractable steady state simulation using hybrid actuator disks informed by unsteady, actuator line model dynamics.

actuator disk model↗