Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Uncertainty analysis of steady-state measurements with a hot-filament type calorimetric emissometer

Calorimetric emissometers measure total hemispherical emissivity by measuring the heat transferred from a heated sample to its surroundings under a vacuum. The accuracy of emissometers standardized by the ASTM C835-06 are well understood. This work uses the Guide to the Evaluation of Uncertainty in Measurement (GUM) for the propagation uncertainties for an ASTM compliant emissometer. The GUM method was able to develop a measurement model and expressions to determine the uncertainty for other emissometers of this type. Data on ‘as-received’ Hastelloy X was used to develop a detailed uncertainty analysis of the emissivity measurement. Data on ‘as-received’ SS 347 and sandblasted A387 Gr. 91 and previous data by the group on A508/A533B were used to determine uncertainty over the ranges 0.16 to 0.81. For all samples, relative uncertainties in emissivities varied from 0.77% to 2.5% when using a fluxgate magnetometer sensor (FMS) to measure the DC heating current. Data on Hastelloy X using a Hall-effect sensor for DC current and low alloy steel showed the DC current and voltage across the test section to be dominate sources of uncertainty. When these sources were reduced, the specimen temperature and the surface area of the test sections were main sources of uncertainty in the emissivity, especially at higher temperatures. As thermal expansion of the surface was considered in the calculations, correlation between specimen temperature and surface area was examined. It was found to be a small contribution to emissivity's uncertainty despite the differences in linear CTE and its uncertainty for the materials analyzed in this study. For low temperatures, the chamber temperature can be a significant source of uncertainty if not sufficiently cooled. The GUM was also briefly compared to uncertainty from the 2nd and 3rd expansions of the Taylor series. We found that the results were the same when rounding to two significant figures.

42 ENGINEERING↗

Robust Avalanche (1.5 kV, 2 kA/cm²) in Vertical GaN Diodes on Patterned Sapphire Substrate

The lack of avalanche capability is a key limitation of current lateral GaN devices. Despite the report of avalanche in vertical GaN-on-GaN devices, the high wafer cost hinders device commercialization. Here, in this work, we demonstrate a circuit-level avalanche in vertical GaN diodes on low-cost patterned sapphire substrate (PSS), with the avalanche voltage (1.57 kV) and avalanche current density (>2 kA/cm 2 ) both being the highest reported in GaN devices on foreign substrates. The PSS enables a lower dislocation density than conventional sapphire substrate and is employed in high-voltage GaN devices for the first time. The avalanche voltage in the circuit test reaches 98% of the parallel-plane limit, further affirming that near-ideal avalanche breakdown can be realized on GaN devices on foreign substrates. These results show the promise of the GaN-on-PSS platform for low-cost, robust power devices.

42 ENGINEERING↗

The Impact of Different Substituents in Fluorinated Cyclic Carbonates in the Performance of High Voltage Lithium-Ion Battery Electrolyte

Ethylene carbonate (EC) has been used as the Solid-Electrolyte Interphase (SEI) former in the conventional electrolyte for decades. However, its low anodic stability leads to severe capacity decay during cycling under high voltage operation. Therefore, finding a viable electrolyte with high anodic stability and the ability to form robust SEI for high voltage lithium-ion batteries is of primary importance. In this study, a series of electrolytes containing various fluorinated cyclic carbonates as the SEI former have been designed, synthesized and evaluated. Linear sweep voltammetry study suggested that fluorinated cyclic carbonates generally possess higher anodic stability than EC. Based on the cycling performance of LiNi 0.5 Co 0.2 Mn 0.3 O 2 (NMC532)/ graphite full cells, the electrolyte with DFEC/FEMC (1.0 M LiPF 6 ) inhibited the oxidation side reaction on the cathode and forms a vigorous SEI on the anode. The high voltage NMC532/Graphite cell utilizing the novel electrolyte exhibits excellent cycling durability under both room and elevated temperature. The superior performance of the DFEC based electrolyte was further unveiled by SEM, EDAX and XRD. Both the anode and cathode of the full cell employing DFEC based electrolyte retained their intrinsic structures after cycling while the electrodes cycled in conventional electrolyte showed severe degradation.

25 ENERGY STORAGE↗

On the modes of nanosecond pulsed plasmas for combustion ignition of quiescent CH 4 -air mixtures

The effect of transient plasma modes on ignition kernel development are discussed here for a quiescent CH 4 -air combustion model system. A 10 ns high-voltage pulse was applied to a pin-to-pin electrode in lean fuel-air mixtures at room temperature and atmospheric pressure. High-impedance streamer, transient spark and low-impedance spark discharges were identified based on pulse waveforms of voltage and current. A sustained ignition kernel expansion was observed when the plasma discharge transitioned into a transient spark or spark discharge. The minimum ignition energy was obtained at the transient spark mode, which has less than a third of the energy or Coulomb transfer compared to the low-impedance spark. Employing repetitive 10-pulse sequence at 10 kHz, the lean-fuel limit was extended from an equivalence ratio of 0.6 for the single pulse ignition to 0.5. The use of repetitive pulses also allowed streamer breakdown or spark initiation to occur at a lower voltage.

CH 4↗

Low-temperature grapho-epitaxial La-substituted BiFeO 3 on metallic perovskite

Bismuth ferrite has garnered considerable attention as a promising candidate for magnetoelectric spin-orbit coupled logic-in-memory. As model systems, epitaxial BiFeO 3 thin films have typically been deposited at relatively high temperatures (650–800 °C), higher than allowed for direct integration with silicon-CMOS platforms. Here, we circumvent this problem by growing lanthanum-substituted BiFeO 3 at 450 °C (which is reasonably compatible with silicon-CMOS integration) on epitaxial BaPb 0.75 Bi 0.25 O 3 electrodes. Notwithstanding the large lattice mismatch between the La-BiFeO 3 , BaPb 0.75 Bi 0.25 O 3 , and SrTiO 3 (001) substrates, all the layers in the heterostructures are well ordered with a [001] texture. Polarization mapping using atomic resolution STEM imaging and vector mapping established the short-range polarization ordering in the low temperature grown La-BiFeO 3 . Current-voltage, pulsed-switching, fatigue, and retention measurements follow the characteristic behavior of high-temperature grown La-BiFeO 3 , where SrRuO 3 typically serves as the metallic electrode. These results provide a possible route for realizing epitaxial multiferroics on complex-oxide buffer layers at low temperatures and opens the door for potential silicon-CMOS integration.

36 MATERIALS SCIENCE↗

Solvent–Diluent Engineering of Normal-Concentration Organosulfur Electrolytes for High-Voltage Lithium-Ion Batteries

Enabling high‑voltage batteries depends critically on rational electrolyte design. Conventional carbonate electrolytes with LiPF 6 suffer from insufficient oxidative stability, motivating the use of lithium bis(fluorosulfonyl)imide (LiFSI) for its superior high‑temperature and high‑voltage performance. However, LiFSI is relatively costly, and its electrolytes often require high concentrations to suppress aluminum current collector corrosion in cathode architectures and to adequately passivate electrode interfaces. Here, a low‑concentration LiFSI electrolyte is realized by combining a high‑voltage organosulfur solvent, ethyl methyl sulfone (EMS), with a non‑solvating fluorinated diluent, fluorobenzene (FB). Extended cycling of LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) full cells to 4.5 V reveals substantial long‑term performance advantages over conventional carbonate electrolytes. Comparison with a popular cyclic sulfone, tetramethylene sulfone (TMS), shows that ring‑containing structures such as TMS strongly influence passivation behavior, ultimately limiting performance and narrowing the viable operating window. Overall, EMS is identified as a uniquely stable solvent for LiFSI‑based electrolytes operating at moderately high voltages.

Dato, Michael A. [Argonne National Laboratory (ANL↗

Soft Switching Over the Entire Line Cycle for a Quadruple Active Bridge DCX in a DC to Three-Phase AC Module

This paper is focused on a transformer-isolated quadruple active bridge (QAB) dc-dc converter loaded by three full-bridge dc-ac inverters. The QAB functions as a "DC trans-former" (DCX) in the dc-to-three-phase ac module. The QAB outputs provide time-varying power at twice the line frequency, which presents challenges in maintaining zero voltage switching (ZVS) on the secondary sides during low-power portions of the line cycle. It is shown how ZVS can be achieved in a phase, even at zero-power transfer, using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. The approach is particularly effective in high-voltage applications using SiC MOSFETs, where reductions in switching loss outweigh additional conduction losses due to the circulating currents. A detailed analysis of ZVS switching waveforms at the zero power transfer is presented, including effects of nonlinear device capacitances. Analytical expressions are given for the optimal values of the magnetizing inductance and dead times of the QAB primary and secondary bridges. The approach is verified by experimental results on a 600 V, 4 kW prototype, demonstrating greater than 98.5% efficiency from 1 kW to 4 kW, with a peak efficiency of 99.0%. Compared to conventionally operated prototype, a 54% reduction in total loss is achieved at rated power.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗

Optimizing TinyTPC Test Stand for Low Energy Event Reconstruction

Introducing dopants into liquid argon offers a promising avenue to enhance the sensitivity and performance of LAr detectors such as DUNE. To explore this opportunity, we are optimizing and deploying the TinyTPC test stand, a compact time projection chamber with LArPix readout to study the effects of photosensitive dopants on the charge detected. TinyTPC enables comparative measurements of low-energy responses under various operational configurations and provides a platform to study the behavior of pixel readouts at low energy. We ensured system reliability through continuous current and voltage monitoring, modeling the detector's electrical behavior, and indirectly estimating total resistance under testing conditions. We ran the Blanche cryostat under various thresholds and gain configurations to evaluate their potential impact to low-energy event reconstruction and advancing R&D efforts for dopant integration in neutrino detectors

Van Loenen, Drew [Franciscan U. Steubenville]↗

Effects of sample bias on adhesion of magnetron sputtered Cr coatings on SiC

Swelling of SiC at 300 C due to in-service neutron irradiation causes tensile residual stresses in coatings which are expected to adversely affect the performance of coated SiC composite fuel cladding for light water reactors. Matching the coating swelling with the substrate, a solution common for thermal expansion, is not practical in the case of neutron irradiation. Biasing samples during magnetron sputtering deposition induces compressive residual stress which may counteract this. In this study, chromium coatings were deposited on SiC by DC magnetron sputtering with no external heating at bias voltages of –50V, –75V, and –100V. The effects of the bias voltage on morphology, residual stress, microstrain, texture, and adhesion are shown. The low deposition temperature resulted in the coating microstructure evolution following an energetic particle bombardment dominated trend. Additionally, at the two lower bias voltages knock-on implantation dominated increasing the residual stress and microstrain while at the highest bias voltage, thermal spike migration allowed for defect relaxation. When the knock-on induced compressive residual stress exceeded 0.8 GPa microcrack formation in the SiC substrate decreased coating adhesion. While no microcracks formed at the lowest bias voltage, insufficient atomic mobility during coating growth lead to voids forming in the coating. A balance is needed to form void-free coatings that have high compressive residual stress.

36 MATERIALS SCIENCE↗

Model-Free Dynamic Voltage Control of Distributed Energy Resource (DER)-Based Microgrids

In this paper, we present a new control technique for sustaining dynamic voltage stability by effective reactive power control and coordination of distributed energy resources (DERs) in microgrids. The proposed control technique is based on model-free control (MFC), which has shown successful operation and improved performance in different domains and applications. This paper presents its first use in the voltage stability of a microgrid setting employing multiple synchronous generator (SG)-based and power electronic (PE)-based DERs. MFC is a computationally efficient, data-driven control technique that does not require modelling of the different components and disturbances in the power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by multiple DERs is considered as a case study and the overall dynamic voltage stability is investigated using time-domain dynamic simulations. Numerical results show that the proposed MFC provides improvements on the dynamic load bus voltage profiles and requires less computational time as compared to the traditional enhanced microgrid voltage stabilizer (EMGVS) scheme. Due to its simplicity and low computational requirement, MFC can be easily implemented in resource-constrained computing devices such as smart inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measuring characteristic differences between high- and low-performing discharges on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF

A dense plasma focus (DPF) is a compact coaxial plasma gun, which completes its discharge as a Z-pinch, producing short (<100 ns) pulses of ions, x rays, and/or neutrons. Lawrence Livermore National Laboratory recently constructed and began operating a new device, the MJOLNIR (MegaJOuLe Neutron Imaging Radiography) DPF, which is designed for single-pulse flash neutron radiography. This device has achieved neutron yields of up to 4.1×10 11 neutrons/pulse at 3.3 MA peak current, and higher-current commissioning is under way. Like most DPFs, MJOLNIR exhibits variable yields in some configurations. Here, we present evidence of the role of parasitic current paths within the gun in stochastically influencing the yield. First through “conditioning shots,” where new hardware has been introduced, we show that increased run-down and run-in speeds correlate with higher yields. These observations are consistent with current being delivered to the electrodes but not to the main plasma sheath, degrading the implosion-driving force. Once nominal conditions are established, we correlate low-performing discharges with smaller current dip and associated voltage spike for a fixed machine configuration. A snow-plow model is able to recreate small-magnitude current dips through the introduction of a parasitic current path, and particle-in-cell simulations establish how parasitic current paths lower the ion beam energy available to produce neutrons. Finally, we observe an increased likelihood of shots with low yield and smaller current dip with increasing fill pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studies of a modulated Hall thruster

A typical Hall thruster is powered from a DC power supply and operates with a constant discharge voltage. In operation, the discharge current is subject to strong low frequency oscillations (so-called breathing oscillations). Recent studies have shown that not only can these breathing oscillations be correlated with improved performance, but these oscillations can be induced and controlled by modulating the anode voltage. In this work, a systematic experimental study of the plasma flow in a modulated cylindrical Hall thruster was performed to characterize the effect of natural and modulated breathing oscillations on thruster performance. Measurements suggest that modulating the anode voltage in resonance with the natural breathing frequency does increase the thrust, but a corresponding phase alignment of discharge current and discharge voltage causes the efficiency gains to be insignificant. In addition, the outward shift of the acceleration region causes the plasma plume divergence to increase at the resonance condition and thereby, limit the thrust increase. Further, mechanisms underlying the relative phase between discharge current, ion current, and discharge voltage are investigated experimentally and corroborated with one-dimensional hybrid simulations of the thruster discharge.

modelling↗

A weakly ion pairing electrolyte designed for high voltage magnesium batteries

High-voltage rechargeable magnesium batteries (RMBs) are potential alternatives to lithium-ion batteries owing to the low cost and high abundance of magnesium. However, the parasitic reactions of the latter with many electrolytes greatly hinders the stability and kinetics of Mg plating/stripping. Here we report a new and easily accessible solvent-designed electrolyte, which effectively solves the difficulty of ion pair dissociation and facilitates fast nanoscale Mg nucleation/growth using simple Mg(TFSI)2 as the salt, enabling a facile interfacial charge transfer process. Dendrite-free Mg plating/stripping is maintained for over 7000 hours (∼10 months) at a practical areal capacity of 2 mA h cm−2. The high-voltage stability of these electrolytes is demonstrated by benchmarking with polyaniline||Mg full cells with an operating voltage up to 3.5 V that exhibit stable cycling at a 2C rate with 99% coulombic efficiency after 400 cycles. This work opens up new frontiers in coupling low-cost electrolytes with next-generation high-voltage cathode materials for fast-charging RMBs with long life and high energy densities.

Li, Chang↗

Theoretical Understanding of Effects of Operating Modes on the Performance Durability of Solid Oxide Cells: A Comparison between Potentiostatic and Galvanostatic Operations

In solid oxide cells (SOCs), the choice between galvanostatic (constant current) and potentiostatic (constant voltage) modes does not significantly affect the performance of SOCs as long as the cell components remain unchanged and intact. However, the degradation of cell components, which leads to changes in electrochemical and physical properties of the cell, elevates the importance of the selected operating mode. This paper aims to investigate the effects of galvanostatic and potentiostatic operating modes on the evolving properties of SOCs and their subsequent influence on performance durability. Employing non-equilibrium thermodynamic analysis, a crucial approach for understanding the degradation phenomena within an active electrochemical system, this study aims to provide in-depth insights into how these operating modes affect the longevity and efficacy of SOCs. Key findings include: In cases where oxygen electrode (OE) degradation is accelerated by higher partial pressure of oxygen ( p O 2 ), operating under constant voltage electrolysis can mitigate the high p O 2 at the OE|electrolyte (OE|EL) interface. Conversely, if OE degradation occurs more rapidly under a lower p O 2 , constant current electrolysis is more effective in suppressing degradation by achieving a high p O 2 at the OE|EL interface. For degradation of the fuel electrode (FE) due to higher p O 2 , constant current electrolysis is beneficial for more stable performance, which helps maintain low p O 2 at the FE|EL interface. When FE degradation is accelerated by lower p O 2 , constant voltage electrolysis can avert low p O 2 at the FE|EL interface. In practical scenarios, more complex degradation mechanisms come into play, especially when p O 2 significantly deviates from initial conditions. Degradation in one electrode can influence p O 2 in the other electrode, a phenomenon more pronounced in potentiostatic than in galvanostatic electrolysis.

Electrochemistry↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

Bipolar plate flow channel designs for vanadium redox flow battery: a review

Vanadium redox flow battery is one of the preferred systems for grid scale energy storage due to long service life (>20000 cycles), higher efficiency (>85 %), deep discharge capability (>95 % DoD), and inherent scalability and safety. Among system components, flow field is most critical as it governs electrolyte distribution, mass transport and hydraulic performance. Here, this review examines emerging flow channel geometries, highlighting the impact of channel width (0.66 to 1.5 mm), depth (1 to 1.5 mm) and land width (0.5 to 1.5 mm) can reduce pressure drop to <10 kPa while enabling power densities above 600 mW.cm -2 . A key finding is that low channel width to depth ratio (<1) enhances voltage and energy efficiencies by improving under rib convection. The review also provides an overview of progress and perspective in bipolar plate materials, manufacturability, and shunt current mitigation strategies for stack scaling up. Cost analysis emphasizes the influence of flow field designs on the levelized cost of storage and pathways towards the US DOE's $\$$0.05 per kWh energy generation cost target. In addition, opportunities for AI/ML/DT tools assisted design and data driven optimization strategies are also outlined to accelerate next generation flow field development.

Efficiency optimization↗