Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Long duration biaxial cylinder testing of balloon grade polyethylene films with emphasis on automated data acquisition and control

Characterization of a 2-dimensional material constitutive model in the practical biaxial state for engineering utility of balloon envelope structural analysis is achievable with laboratory cylinder tests. Hoop (circumferential, and longitudinal strains are time-wise measured on axially loaded pressurized cylinders. Pre-programmed ramped loading changes as well as precise long term pressure control are achieved through cascaded proportional, integral derivative (PID) flow control loops that are part of an integrated data acquisition and process control system. Real time data reduction and analysis allow monitoring of unattended tests that have durations of up to a month. Measured and controlled parameters and variables are discussed; date analysis techniques are reviewed.

Martone, Michael↗

Using NASA's Giovanni System to Simulate Time-Series Stations in the Outflow Region of California's Eel River

Oceanographic time-series stations provide vital data for the monitoring of oceanic processes, particularly those associated with trends over time and interannual variability. There are likely numerous locations where the establishment of a time-series station would be desirable, but for reasons of funding or logistics, such establishment may not be feasible. An alternative to an operational time-series station is monitoring of sites via remote sensing. In this study, the NASA Giovanni data system is employed to simulate the establishment of two time-series stations near the outflow region of California s Eel River, which carries a high sediment load. Previous time-series analysis of this location (Acker et al. 2009) indicated that remotely-sensed chl a exhibits a statistically significant increasing trend during summer (low flow) months, but no apparent trend during winter (high flow) months. Examination of several newly-available ocean data parameters in Giovanni, including 8-day resolution data, demonstrates the differences in ocean parameter trends at the two locations compared to regionally-averaged time-series. The hypothesis that the increased summer chl a values are related to increasing SST is evaluated, and the signature of the Eel River plume is defined with ocean optical parameters.

Acker, James G.↗

Earth Independent Medical Operations (EIMO)

Inherent in interplanetary space travel are unprecedented challenges that could threaten mission success and negatively impact crew health and performance. Return to definitive care is essentially untenable and resources will be constrained with practically no re-supply capability. Access to ground-based medical expertise will be significantly delayed under nominal conditions with exacerbation during conjunction or prolonged dust storms. Taken together, these challenges necessitate the development of a progressively autonomous medical operational support system to assist the crew medical officer (CMO). While support from ground based medical experts will remain indispensable for pre-mission planning, the approach to management of acute/emergent medical contingencies will require a gradual transition of medical care and decision making from terrestrial to space-based assets, enabling support of astronaut health and performance and reducing overall mission risk. To progressively enable EIMO, a series of meetings were convened with subject matter experts from within NASA, academia and industry to facilitate mapping of the path to support autonomous medical operations. Topics explored in these meetings included the scope of data (storage capacity, usage, transmission rate and bandwidth, computing capacity), CMO training, supply and resource management and task load balance. Recommendations from these meetings will inform the EIMO Concept of Operations and definition of the associated requirements culminating in updates to the NASA 3001 standards. The EIMO project team will work with stakeholders to conceptualize a clinical decision support system (CDSS) to assist the CMO in response to medical contingencies when terrestrial support is delayed or otherwise unavailable. The CDSS will be a system of systems that will utilize data from numerous input vectors. Successful deployment of the CDSS will facilitate medical decision making while decreasing the cognitive load leading to an improvement in task load balancing. Additional benefits of the envisioned CDSS include assistance with inventory management, locating resources, storage/retrieval of medical records, highlighting trends in recorded data, in addition to providing a consult for diagnosis and treatment. More advanced features might include passive monitoring to identify early warning signs of behavioral or medical anomalies to possibly pre-empt onset of conditions that would compromise crew health and performance.

Benjamin Easter↗

A TEOM (tm) particulate monitor for comet dust, near Earth space, and planetary atmospheres

Scientific missions to comets, near earth space, and planetary atmospheres require particulate and mass accumulation instrumentation for both scientific and navigation purposes. The Rupprecht & Patashnick tapered element oscillating microbalance can accurately measure both mass flux and mass distribution of particulates over a wide range of particle sizes and loadings. Individual particles of milligram size down to a few picograms can be resolved and counted, and the accumulation of smaller particles or molecular deposition can be accurately measured using the sensors perfected and toughened under this contract. No other sensor has the dynamic range or sensitivity attained by these picogram direct mass measurement sensors. The purpose of this contract was to develop and implement reliable and repeatable manufacturing methods; build and test prototype sensors; and outline a quality control program. A dust 'thrower' was to be designed and built, and used to verify performance. Characterization and improvement of the optical motion detection system and drive feedback circuitry was to be undertaken, with emphasis on reliability, low noise, and low power consumption. All the goals of the contract were met or exceeded. An automated glass puller was built and used to make repeatable tapered elements. Materials and assembly methods were standardized, and controllers and calibrated fixtures were developed and used in all phases of preparing, coating and assembling the sensors. Quality control and reliability resulted from the use of calibrated manufacturing equipment with measurable working parameters. Thermal and vibration testing of completed prototypes showed low temperature sensitivity and high vibration tolerance. An electrostatic dust thrower was used in vacuum to throw particles from 2 x 10(exp 6) g to 7 x 10(exp -12) g in size. Using long averaging times, particles as small as 0.7 to 4 x 10(exp 11) g were weighted to resolutions in the 5 to 9 x 10(exp -13) g range. The drive circuit and optics systems were developed beyond what was anticipated in the contract, and are now virtually flight prototypes. There is already commercial interest in the developed capability of measuring picogram mass losses and gains. One area is contamination and outgassing research, both measuring picogram losses from samples and collecting products of outgassing.

Source record↗

The BioSensor Instrument Beyond LEIA: a Versatile Platform for Lunar Biology

Introduction: The BioSensor is a deep-space-compatible automated microfluidic culturing instrument. While originally designed to measure the effects of deep space radiation on yeast growth for the BioSentinel mission, it has the potential to host a diverse range of life science experiments with single- and/or multi-celled organisms and can be adapted to interface with a diverse range of platforms in both crewed and uncrewed settings. It is therefore a leading candidate for hosting life sciences experimentation associated with a lunar surface habitat. BioSensor design: The function of the BioSensor is to monitor the growth and metabolic activity of samples in batch fluidic culture, without the need for crew involvement. The current configuration houses organisms in 16 wells within 16 microfluidic cards, accommodating a total of 256 samples, replicates, and controls. Each well has an optical system including three LEDs and a photodiode detector to measure absorbance at three wavelengths, enabling measurement of optical density, color change in dyes such as alamarBlue, and bioproduction of pigmented compounds. Organisms are loaded into fluidic wells and air-dried for storage during integration, launch, and transit, then activated by the introduction of culture medium from storage bags via manifolds that fill one card at a time. Temperature is controlled by individual card heaters, and timing of all activities (fluidics fills, optical measurements, temperatures) is directed by an experiment script. The self-contained BioSensor payload is roughly 4U in volume; with electrical/mechanical/thermal interface, e.g. for operation on ISS or a lunar lander, as well as a linear energy-transfer (LET) charged-particle radiation spectrometer, the entire system is closer to 6U. BioSentinel and LEIA: Flown on the ISS and in a deep-space free flyer for BioSentinel, the BioSensor has been modified for use in the LEIA mission, including improvements to reduce the sensitivity to lengthy launch delays. LEIA will monitor yeast growth in the radiation and reduced-gravity environment of the lunar surface no earlier than 2026, on a CLPS lander [4]. Changes include accommodating additional culture media and an additional LED color for a new biological assay (bioproduction of carotenoids-- dietary antioxidants), as well as modifications to the housing to allow late-load biology changeout and improved isolation between fluidics and electronics. Future prospects: Future work with the BioSensor, beyond LEIA, will include expanding the range and diversity of organisms and assays accommodated. Preliminary work has demonstrated the growth of Arabidopsis seedlings in BioSensor fluidic cards, including optical measurements of growth rate over time. Minor modifications could allow measurement of phenotypes related to photosynthetic capacity in both plants and cyanobacteria. The experimental capabilities of the BioSensor could be dramatically increased by introducing the capability for fluorescence measurements, and/or the design of novel biological assays using luminescence. The BioSensor can also be adapted for new platforms and experiment settings; in addition to free-flyer, ISS, and CLPS lander, a preliminary design concept has been developed for crewed deployment directly to the lunar surface. The instrument could be accommodated inside a lunar habitat, where its automated operation would make it an excellent candidate for experiments from fundamental investigations into the response of organisms to lunar surface conditions to applied-science purposes such as screening engineered strains of various organisms for bioproduction capability.

J A Lee↗

Acoustic emission during unloading of elastically stressed magnesium alloy

A magnesium alloy was quasi-statically cycled elastically between zero load and tension. Both loading and unloading stress delays were found, and the unloading stress delay was further studied. An analytical expression was written for the unloading stress delay which is an elastic constitutive parameter. The potential use of these results for the acoustic emission monitoring of elastic stress states is discussed.

Lee, S. S.↗

Advanced Earth-to-orbit propulsion technology program overview: Impact of civil space technology initiative

The NASA Earth-to-Orbit (ETO) Propulsion Technology Program is dedicated to advancing rocket engine technologies for the development of fully reusable engine systems that will enable space transportation systems to achieve low cost, routine access to space. The program addresses technology advancements in the areas of engine life extension/prediction, performance enhancements, reduced ground operations costs, and in-flight fault tolerant engine operations. The primary objective is to acquire increased knowledge and understanding of rocket engine chemical and physical processes in order to evolve more realistic analytical simulations of engine internal environments, to derive more accurate predictions of steady and unsteady loads, and using improved structural analyses, to more accurately predict component life and performance, and finally to identify and verify more durable advanced design concepts. In addition, efforts were focused on engine diagnostic needs and advances that would allow integrated health monitoring systems to be developed for enhanced maintainability, automated servicing, inspection, and checkout, and ultimately, in-flight fault tolerant engine operations.

Stephenson, Frank W., Jr.↗

Failure mechanisms of 3-D woven SiC/SiC composites under tensile and flexural loading at room and elevated temperatures

Nicalon silicon carbide 3D yarn with silicon carbide matrix composites made through a chemical vapor infiltration (CVI) process were investigated under tensile and flexural loading at 23, 1200 and 1550 C in air. The effectiveness of a chemical vapor deposition (CVD) SiC surface coating was also evaluated in severe oxidizing environment. Acoustic emission sensors and in situ optical microscopy were used at room temperature to monitor the failure mechanisms. It is shown that the level of tensile stress at which nonlinear behavior begins is not drastically reduced at 1200 and 1550 C when composites were protected by a SiC surface coating. Extensive fiber pull-out was observed only in the 1550 C specimen. Similar behaviors were also found in flexural specimens.

Chulya, Abhisak↗

Status of Electrical Actuator Applications

An ever increasing number of actuation functions historically performed by hydraulics or pneumatics are being accomplished by electric actuation. If 'end to end' systems are considered, electric actuators (EA's) are potentially lighter and more efficient. In general, system redundancies may be more easily implemented and operationally monitored. Typically, electrical components exhibit longer mean times to failure and projected lifetime costs of EA's are potentially much lower than those of other options. EA's have certain characteristics which must be considered in their application. The actual mechanical loadings must be established, for the more easily controlled EA may be operated much closer to its full capabilities. At higher rates of motion, EA's are operating as constant power devices. Therefore, it may be possible to start a movement that can not be stopped. The incorporation of high power electronics into remote locations introduces new concerns of EMI and thermal control. It is the management of these and other characteristics that forms the engineering design challenges. Work is currently in progress on EA's for aircraft and expendable launch vehicles. These applications span from ten to 40+ horsepower. The systematics and status of these actuators will be reported along with current technical trends in this area.

Roth, Mary Ellen↗

Design of a Parachute Canopy Instrumentation Platform

This paper discusses the current technology available to design and develop a reliable and compact instrumentation platform for parachute system data collection and command actuation. Wireless communication with a parachute canopy will be an advancement to the state of the art of parachute design, development, and testing. Embedded instrumentation of the parachute canopy will provide reefing line tension, skirt position data, parachute health monitoring, and other telemetry, further validating computer models and giving engineering insight into parachute dynamics for both Earth and Mars entry that is currently unavailable. This will allow for more robust designs which are more optimally designed in terms of structural loading, less susceptible to adverse dynamics, and may eventually pave the way to currently unattainable advanced concepts of operations. The development of this technology has dual use potential for a variety of other applications including inflatable habitats, aerodynamic decelerators, heat shields, and other high stress environments.

Alshahin, Wahab M.↗

A study of elevated temperature testing techniques for the fatigue behavior of PMCS: Application to T650-35/AMB21

An experimental study was conducted to investigate the mechanical behavior of a T650-35/AMB21 eight-harness satin weave polymer composite system. Emphasis was placed on the development and refinement of techniques used in elevated temperature uniaxial PMC testing. Issues such as specimen design, gripping, strain measurement, and temperature control and measurement were addressed. Quasi-static tensile and fatigue properties (R(sub sigma) = 0.1) were examined at room and elevated temperatures. Stiffness degradation and strain accumulation during fatigue cycling were recorded to monitor damage progression and provide insight for future analytical modeling efforts. Accomplishments included an untabbed dog-bone specimen design which consistently failed in the gage section, accurate temperature control and assessment, and continuous in-situ strain measurement capability during fatigue loading at elevated temperatures. Finally, strain accumulation and stiffness degradation during fatigue cycling appeared to be good indicators of damage progression.

Gyekenyesi, Andrew L.↗

Real-Time Deposition Monitor for Ultrathin Conductive Films

A device has been developed that can be used for the real-time monitoring of ultrathin (2 or more) conductive films. The device responds in less than two microseconds, and can be used to monitor film depositions up to about 60 thick. Actual thickness monitoring capability will vary based on properties of the film being deposited. This is a single-use device, which, due to the very low device cost, can be disposable. Conventional quartz/crystal microbalance devices have proven inadequate to monitor the thickness of Pd films during deposition of ultrathin films for hydrogen sensor devices. When the deposited film is less than 100 , the QCM measurements are inadequate to allow monitoring of the ultrathin films being developed. Thus, an improved, high-sensitivity, real-time deposition monitor was needed to continue Pd film deposition development. The new deposition monitor utilizes a surface acoustic wave (SAW) device in a differential delay-line configuration to produce both a reference response and a response for the portion of the device on which the film is being deposited. Both responses are monitored simultaneously during deposition. The reference response remains unchanged, while the attenuation of the sensing path (where the film is being deposited) varies as the film thickness increases. This device utilizes the fact that on high-coupling piezoelectric substrates, the attenuation of an SAW undergoes a transition from low to very high, and back to low as the conductivity of a film on the device surface goes from nonconductive to highly conductive. Thus, the sensing path response starts with a low insertion loss, and as a conductive film is deposited, the film conductivity increases, causing the device insertion loss to increase dramatically (by up to 80 dB or more), and then with continued film thickness increases (and the corresponding conductivity increases), the device insertion loss goes back down to the low level at which it started. This provides a continuous, real-time monitoring of film deposition. For use with different films, the device would need to be calibrated to provide an understanding of how film thickness is related to film conductivity, as the device is responding primarily to conductivity effects (and not to mass loading effects) in this ultrathin film regime.

Hines, Jacqueline↗

Technique for Radiometer and Antenna Array Calibration - TRAAC

Highly sensitive receivers are used to detect minute amounts of emitted electromagnetic energy. Calibration of these receivers is vital to the accuracy of the measurements. Traditional calibration techniques depend on calibration reference internal to the receivers as reference for the calibration of the observed electromagnetic energy. Such methods can only calibrate errors in measurement introduced by the receiver only. The disadvantage of these existing methods is that they cannot account for errors introduced by devices, such as antennas, used for capturing electromagnetic radiation. This severely limits the types of antennas that can be used to make measurements with a high degree of accuracy. Complex antenna systems, such as electronically steerable antennas (also known as phased arrays), while offering potentially significant advantages, suffer from a lack of a reliable and accurate calibration technique. The proximity of antenna elements in an array results in interaction between the electromagnetic fields radiated (or received) by the individual elements. This phenomenon is called mutual coupling. The new calibration method uses a known noise source as a calibration load to determine the instantaneous characteristics of the antenna. The noise source is emitted from one element of the antenna array and received by all the other elements due to mutual coupling. This received noise is used as a calibration standard to monitor the stability of the antenna electronics.

Meyer, Paul↗

Utilizing Modal Testing for Monitoring the Structural Health of Wind Tunnel Facility Hardware

The 10- by 10-Foot Abe Silverstein Supersonic Wind Tunnel (10×10) is the largest and fastest wind tunnel facility at NASA’s Glenn Research Center(GRC) and is specifically designed to test supersonic propulsion components from inlets and nozzles to full-scale jet and rocket engines[1]. Recently, a critical part of the wind tunnel failed and required a redesign before reintegrating into the facility. The design requirements of this new component required that clearances between large metallic components exist, which have the potential for undesirable nonlinear dynamics to occur, in particular rattling. Rattling is feared to occur when the wind tunnel is being operated in certain flow regimes that induce cyclic aero loads on the new component near its natural frequencies. This paper describes the approach taken to better understand and resolve this vibration problem using modal testing. A modal test was developed and executed by GRC’s Structural Dynamics Lab to quantify the modal parameters of the structure, namely which specific excitation frequencies caused the structure to rattle. These results were shared with facility operators as frequency ranges that should be avoided to ensure maximum lifespan of the new structure. Additional means of structural health monitoring (SHM) as well as Vortex shedding are briefly discussed in this paper.

Pederson, Kenneth↗

Constitutive acoustic-emission elastic-stress behavior of magnesium alloy

Repeated laoding and unloading of a magnesium alloy below the macroscopic yield stress result in continuous acoustic emissions which are generally repeatable for a given specimen and which are reproducible between different specimens having the same load history. An acoustic emission Bauschinger strain model is proposed to describe the unloading emission behavior. For the limited range of stress examined, loading and unloading stress delays of the order of 50 MN/sq m are observed, and they appear to be dependent upon the direction of loading, the stress rate, and the stress history. The stress delay is hypothesized to be the manifestation of an effective friction stress. The existence of acoustic emission elastic stress constitutive relations is concluded, which provides support for a previously proposed concept for the monitoring of elastic stresses by acoustic emission.

Williams, J. H., Jr.↗

Cryogenic cooling for spacecraft sensors, instruments, and experiments

Several disciplines requiring in-space cryogenic cooling are identified including high-energy, gamma-ray, and IR astronomy, relativity missions, and superconducting devices. Radiant coolers are limited in terms of temperature ranges and cooling loads. Other spacecraft cryogenic systems include stored solid cryogenic coolers using materials such as hydrogen, neon, argon, and methane. Two such cooler designs are described including one for the Nimbus F limb radiance inversion radiometer and one for the Nimbus G limb infrared monitoring of the atmosphere. Suggestions for increasing the performance of solid cryogenic coolers are made, such as a multimission cooler, a mechanical refrigerator, Stirling-cycle refrigerators, and Vuilleumier mechanized coolers. Techniques for obtaining cryogenic cooling in the milli-K range are identified as dilution refrigeration and adiabatic demagnetization.

Sherman, A.↗

Characterization of Mode 1 and Mode 2 delamination growth and thresholds in graphite/peek composites

Composite materials often fail by delamination. The onset and growth of delamination in AS4/PEEK, a tough thermoplastic matrix composite, was characterized for mode 1 and mode 2 loadings, using the Double Cantilever Beam (DCB) and the End Notched Flexure (ENF) test specimens. Delamination growth per fatigue cycle, da/dN, was related to strain energy release rate, G, by means of a power law. However, the exponents of these power laws were too large for them to be adequately used as a life prediction tool. A small error in the estimated applied loads could lead to large errors in the delamination growth rates. Hence strain energy release rate thresholds, G sub th, below which no delamination would occur were also measured. Mode 1 and 2 threshold G values for no delamination growth were found by monitoring the number of cycles to delamination onset in the DCB and ENF specimens. The maximum applied G for which no delamination growth had occurred until at least 1,000,000 cycles was considered the threshold strain energy release rate. Comments are given on how testing effects, facial interference or delamination front damage, may invalidate the experimental determination of the constants in the expression.

Martin, Roderick H.↗

Characterization of Mode I and Mode II delamination growth and thresholds in AS4/PEEK composites

Composite materials often fail by delamination. The onset and growth of delamination in AS4/PEEK, a tough thermoplastic matrix composite, was characterized for mode 1 and mode 2 loadings, using the Double Cantilever Beam (DCB) and the End Notched Flexure (ENF) test specimens. Delamination growth per fatigue cycle, da/dN, was related to strain energy release rate, G, by means of a power law. However, the exponents of these power laws were too large for them to be adequately used as a life prediction tool. A small error in the estimated applied loads could lead to large errors in the delamination growth rates. Hence strain energy release rate thresholds, G sub th, below which no delamination would occur were also measured. Mode 1 and 2 threshold G values for no delamination growth were found by monitoring the number of cycles to delamination onset in the DCB and ENF specimens. The maximum applied G for which no delamination growth had occurred until at least 1,000,000 cycles was considered the threshold strain energy release rate. Comments are given on how testing effects, facial interference or delamination front damage, may invalidate the experimental determination of the constants in the expression.

Martin, Roderick H.↗