Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Creating 3D Models With The Faro Scanner

The Faro Focus X 330 is a 3D scanner that combines numerous technologies in order to create a precise and life like 3D model. The technologies used by the scanner include: Time of flight (The scanner spins horizontally and vertically while emitting a class 1 laser; The laser beam then bounces off of an object and is captured by a sensor; An extremely precise chronometer tracks the beams flight time; The data is inputted into the simple formula: d=c*t/2). Point cloud system: The exact position of up to 976,000 points per second are registered and combined to form a complete model with up to ±1 mm at 330 m. Camera: Photos are taken of the surroundings that are combined to make a 165 megapixel image. The image is paired with the point cloud system. Scans have been taken of buildings 730-A and 781-A. These scans will be put into different virtual reality programs and used for tours and training. The scans also serve as a proof of concept for the Faro Focus X 330 as well as SRNL's ability to produce accurate scans with numerous useful applications. Work Scope Planning: Scanning will result in higher productivity and reduce the risk by identifying hazards; Blueprints and designs; 3D scans allow greater collaboration between engineers, construction crews, etc. by enabling them to compare blueprints to real time progress and make adjustments. Training and walk-downs: Scans can be made of places where access is not readily available, this could be due to its remote location or hazards such as radioactivity.

42 ENGINEERING↗

Redshifting galaxies from DESI to JWST CEERS: Correction of biases and uncertainties in quantifying morphology

Observations of high-redshift galaxies with unprecedented detail have now been rendered possible with the James Webb Space Telescope (JWST). However, accurately quantifying their morphology remains uncertain due to potential biases and uncertainties. To address this issue, we used a sample of 1816 nearby DESI galaxies, with a stellar mass range of 10 9.75 - 11.25 M ⊙ , to compute artificial images of galaxies of the same mass located at 0.75 ≤ z ≤ 3 and observed at rest-frame optical wavelength in the Cosmic Evolution Early Release Science (CEERS) survey. We analyzed the effects of cosmological redshift on the measurements of Petrosian radius (R p ), half-light radius (R 50 ), asymmetry (A), concentration (C), axis ratio (q), and Sérsic index (n). Our results show that R p and R 50 , calculated using non-parametric methods, are slightly overestimated due to PSF smoothing, while R 50 , q, and n obtained through fitting a Sérsic model does not exhibit significant biases. By incorporating a more accurate noise effect removal procedure, we improve the computation of A over existing methods, which often overestimate, underestimate, or lead to significant scatter of noise contributions. Due to PSF asymmetry, there is a minor overestimation of A for intrinsically symmetric galaxies. However, for intrinsically asymmetric galaxies, PSF smoothing dominates and results in an underestimation of A, an effect that becomes more significant with higher intrinsic A or at lower resolutions. Moreover, PSF smoothing also leads to an underestimation of C, which is notably more pronounced in galaxies with higher intrinsic C or at lower resolutions. We developed functions based on resolution level, defined as R p /FWHM, for correcting these biases and the associated statistical uncertainties. Applying these corrections, we measured the bias-corrected morphology for the simulated CEERS images and we find that the derived quantities are in good agreement with their intrinsic values – except for A, which is robust only for angularly large galaxies where R p /FWHM ≥ 5. Our correction functions can be applied to other surveys, offering valuable tools for future studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Crowding-Induced Spatial Organization of Gene Expression in Cell-Sized Vesicles

Cell-free protein synthesis is an important tool for studying gene expression and harnessing it for applications. In cells, gene expression is regulated in part by the spatial organization of transcription and translation. Unfortunately, current cell-free approaches are unable to control the organization of molecular components needed for gene expression, which limits the ability to probe and utilize its effects. In this work, we show, using complementary computational and experimental approaches, that macromolecular crowding can be used to control the spatial organization and translational efficiency of gene expression in cell-sized vesicles. Computer simulations and imaging experiments reveal that, as crowding is increased, DNA plasmids become localized at the inner surface of vesicles. Ribosomes, in contrast, remain uniformly distributed, demonstrating that crowding can be used to differentially organize components of gene expression. We further carried out cell-free protein synthesis reactions in cell-sized vesicles and quantified mRNA and protein abundance. At sufficiently high levels of crowding, we observed localization of mRNA near vesicle surfaces, a decrease in translational efficiency and protein abundance, and anomalous scaling of protein abundance as a function of vesicle size. These results are consistent with high levels of crowding causing altered spatial organization and slower diffusion. Our work demonstrates a straightforward way to control the organization of gene expression in cell-sized vesicles and provides insight into the spatial regulation of gene expression in cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Active interrogation of Special Nuclear Material containers using AmBe quasi-forward biased directional source and PGNAA

Special Nuclear Material (SNM) including 95% 235 U and 239 Pu is capable of being identified by utilizing a quasi-forward directional AmBe source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). HPGe and LaBr 3 detector arrays were used to identify and quantify the peak-to-background and peak-to-total ratios of the associated photon spectra from the SNM encased in a polyethylene shield. The conducted simulations varied the volume of the SNM and neutron source strength in the MCNP data card to conduct an uncertainty analysis. Photopeaks identified include K-shell X-rays from 235 U and 239 Pu, 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peak from the prompt gamma interaction from hydrogen. Relationships between peak-to-total and peak-to-background as a function of SNM and particle history were investigated to aid in the analysis. The capabilities of both detector systems to acquire well resolved photopeak with a 5% relative error or less, with a 1 Ci source activity, and a peak-to-background ratio of 1.15. Finally, this was determined to take 326 s for LaBr 3 and 163 s for HPGe which is comparable to current methods for material detection which take between 100 and 900 s to acquire.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulating Continuum-based Redshift Measurement in the Roman’s High Latitude Spectroscopic Survey

We investigate the capability of the Nancy Grace Roman Space Telescope’s (Roman) Wide-Field Instrument G150 slitless grism to detect red, quiescent galaxies based on the current reference survey. We simulate dispersed images for Roman reference High-Latitude Spectroscopic Survey (HLSS) and analyze two-dimensional spectroscopic data using the grism Redshift and Line Analysis (Grizli) software. This study focus on assessing Roman grism’s capability for continuum-level redshift measurement for a redshift range of 0.5 ≤ z ≤ 2.5. The redshift recovery is assessed by setting three requirements of: σ z = $\frac{|z–z_{true}|}{1+z}$ ≤ 0.01, signal-to-noise ratio≥ 5 and the presence of a single dominant peak in redshift likelihood function. We find that, for quiescent galaxies, the reference HLSS can reach a redshift recovery completeness of ≥50% for F158 magnitude brighter than 20.2 mag. We also explore how different survey parameters, such as exposure time and the number of exposures, influence the accuracy and completeness of redshift recovery, providing insights that could optimize future survey strategies and enhance the scientific yield of the Roman in cosmological research.

Astronomical simulations↗

Individual-specific multi-scale finite element simulation of cortical bone of human proximal femur

We present an innovative method to perform multi-scale finite element analyses of the cortical component of the femur using the individual’s (1) computed tomography scan; and (2) a bone specimen obtained in conjunction with orthopedic surgery. The method enables study of micro-structural characteristics regulating strains and stresses under physiological loading conditions. The analysis of the micro-structural scenarios that cause variation of strain and stress is the first step in understanding the elevated strains and stresses in bone tissue, which are indicative of higher likelihood of micro-crack formation in bone, implicated in consequent remodeling or macroscopic bone fracture. Evidence that micro-structure varies with clinical history and contributes in significant, but poorly understood, ways to bone function, motivates the method’s development, as does need for software tools to investigate relationships between macroscopic loading and micro-structure. Three applications – varying region of interest, bone mineral density, and orientation of collagen type I, illustrate the method. We show, in comparison between physiological loading and simple compression of a patient’s femur, that strains computed at the multi-scale model’s micro-level: (i) differ; and (ii) depend on local collagen-apatite orientation and degree of calcification. Our findings confirm the strain concentration role of osteocyte lacunae, important for mechano-transduction. We hypothesize occurrence of micro-crack formation, leading either to remodeling or macroscopic fracture, when the computed strains exceed the elastic range observed in micro-structural testing.

60 APPLIED LIFE SCIENCES↗

Anatomic Boundaries of the Clinical Target Volume (Prostate Bed) After Radical Prostatectomy

Purpose: We sought to derive and validate an interdisciplinary consensus definition for the anatomic boundaries of the postoperative clinical target volume (CTV, prostate bed). Methods and Materials: Thirty one patients who had planned for radiotherapy after radical prostatectomy were enrolled and underwent computed tomography and magnetic resonance imaging (MRI) simulation prior to radiotherapy. Through an iterative process of consultation and discussion, an interdisciplinary consensus definition was derived based on a review of published data, patterns of local failure, surgical practice, and radiologic anatomy. In validation, we analyzed the distribution of surgical clips in reference to the consensus CTV and measured spatial uncertainties in delineating the CTV and vesicourethral anastomosis. Clinical radiotherapy plans were retrospectively evaluated against the consensus CTV (prostate bed). Results: Anatomic boundaries of the consensus CTV (prostate bed) are described. Surgical clips (n = 339) were well distributed throughout the CTV. The vesicourethral anastomosis was accurately localized using central sagittal computed tomography reconstruction, with a mean {+-} standard deviation uncertainty of 1.8 {+-} 2.5 mm. Delineation uncertainties were small for both MRI and computed tomography (mean reproducibility, 0-3.8 mm; standard deviation, 1.0-2.3); they were most pronounced in the anteroposterior and superoinferior dimensions and at the superior/posterior-most aspect of the CTV. Retrospectively, the mean {+-} standard deviation CTV (prostate bed) percentage of volume receiving 100% of prescribed dose was only 77% {+-} 26%. Conclusions: We propose anatomic boundaries for the CTV (prostate bed) and present evidence supporting its validity. In the absence of gross recurrence, the role of MRI in delineating the CTV remains to be confirmed. The CTV is larger than historically practiced at our institution and should be encompassed by a microscopic tumoricidal dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the use of resolution recovery techniques (i.e. modeling the finite collimator spatial resolution in iterative reconstruction algorithms) can significantly reduce the partial volume errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online Magnetic Resonance Image Guided Adaptive Radiation Therapy: First Clinical Applications

Purpose: To demonstrate the feasibility of online adaptive magnetic resonance (MR) image guided radiation therapy (MR-IGRT) through reporting of our initial clinical experience and workflow considerations. Methods and Materials: The first clinically deployed online adaptive MR-IGRT system consisted of a split 0.35T MR scanner straddling a ring gantry with 3 multileaf collimator-equipped {sup 60}Co heads. The unit is supported by a Monte Carlo–based treatment planning system that allows real-time adaptive planning with the patient on the table. All patients undergo computed tomography and MR imaging (MRI) simulation for initial treatment planning. A volumetric MRI scan is acquired for each patient at the daily treatment setup. Deformable registration is performed using the planning computed tomography data set, which allows for the transfer of the initial contours and the electron density map to the daily MRI scan. The deformed electron density map is then used to recalculate the original plan on the daily MRI scan for physician evaluation. Recontouring and plan reoptimization are performed when required, and patient-specific quality assurance (QA) is performed using an independent in-house software system. Results: The first online adaptive MR-IGRT treatments consisted of 5 patients with abdominopelvic malignancies. The clinical setting included neoadjuvant colorectal (n=3), unresectable gastric (n=1), and unresectable pheochromocytoma (n=1). Recontouring and reoptimization were deemed necessary for 3 of 5 patients, and the initial plan was deemed sufficient for 2 of the 5 patients. The reasons for plan adaptation included tumor progression or regression and a change in small bowel anatomy. In a subsequently expanded cohort of 170 fractions (20 patients), 52 fractions (30.6%) were reoptimized online, and 92 fractions (54.1%) were treated with an online-adapted or previously adapted plan. The median time for recontouring, reoptimization, and QA was 26 minutes. Conclusion: Online adaptive MR-IGRT has been successfully implemented with planning and QA workflow suitable for routine clinical application. Clinical trials are in development to formally evaluate adaptive treatments for a variety of disease sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermodynamic Stability and Site‐Specific Distribution of Graphitic and Pyridinic Nitrogen in Graphene Moiré on Ru(0001)

Abstract Graphene‐like materials are of interest for large‐scale hydrogen storage applications due to their lightweight, durable, and scalable properties. Nitrogen‐doping minimizes kinetic limitations in diffusion and recombination on surfaces, however, the role of graphitic nitrogen (GN) and pyridinic nitrogen (PN) is not well understood. Nitrogen‐doped graphene is synthesized on Ru(0001) using chemical vapor deposition (CVD) of pyridine and ion irradiation. Scanning tunneling microscopy (STM), x‐ray photoelectron spectroscopy (XPS), and density functional theory (DFT) are used to identify the structure, location, and thermodynamic stability of nitrogen species within the graphene moiré. CVD of pyridine results in a low nitrogen concentration (<0.1at%), while the post‐growth nitrogen ion irradiation allows us to increase the concentration further. The concentration of GN and PN is controlled by varying the ion dose and annealing temperature. Comparison of measured and simulated STM images of GN and PN yield an excellent agreement, allowing us to confidently establish that GN is preferentially located near the center of the Atop region, while PN is located in the valley region of the graphene moiré. This report explicitly confirms the site assignments and provides a foundation for the site synthesis and analysis of structural and electronic properties that drive the reactivity of N‐doped graphene.

Gedara, Buddhika S. A. [Physical and Computational↗

What Can Plastic Flow Fields Tell Us About Heat Sources in Deformation Processing?

We characterize primary (shape-change) and secondary (friction) deformation, and associated temperature fields, in metal cutting and forming processes, using in situ imaging and simulation. The experimental configurations enable access to the deformation zones and die contact-interfaces, for measuring deformation, temperature, and frictional drag. Infra-red thermography reveals that the plastic strain-rate field is an excellent proxy for the deformation-induced heat sources. Both spatially confined and diffuse strain-rate fields occur, depending on the initial workpiece deformation state. When the strain rate is confined, as in pre-hardened material, the temperature modeling is much simplified, as the heat source is also now localized. However complex, microstructure-driven deformation modes, like sinuous flow in annealed metals, result in spatially diffuse strain-rate and body heat sources, more challenging to analyze. Furthermore, our unified measurements should be of value for accurately estimating the fraction of plastic dissipation that is converted into heat in large-strain deformation processes.

36 MATERIALS SCIENCE↗

Nitrogen-induced reconstructions on the Cr(001) surface

Here, we use spin-polarized density functional theory to describe the surface reconstructions formed when the Cr(001) surface is exposed to nitrogen. Our primary goal is to clarify the atomic structure of the N induced c(2x2) Cr(001) reconstruction and to study its properties. After analyzing the relative stability of several models with a ½ monolayer of N atoms on the surface, it was found that only two models were stable for different growth conditions. The first stable model shows two N atoms (per cell) adsorbed on hollow sites following a diagonal pattern. In the second, N atoms replace Cr atoms of the first monolayer, and after optimization, they end up in almost second layer positions. To compare with scanning tunneling microscopy experiments, simulated STM images, using the Tersoff-Hamann approximation, were obtained. Our two models can explain the two different c(2x2) Cr(001) reconstructions observed experimentally. The magnetic properties, such as magnetic moments and alignments, are discussed compared with experimental values.

36 MATERIALS SCIENCE↗

Temporal Lung Tumor Volume Changes in Small-Cell Lung Cancer Patients Undergoing Chemoradiotherapy

Purpose: Small-cell lung cancer is considered to be relatively chemosensitive and radiosensitive. Small-cell tumor volume changes during concurrent chemoradiotherapy have not been quantified. The purpose of this work is to quantify small-cell lung tumor volume variations in limited-stage patients undergoing chemoradiotherapy. Methods and Materials: Eligible patients had pathologically confirmed limited-stage small-cell lung cancer, underwent concurrent chemoradiotherapy, and signed study-specific consent forms. Patients underwent serial chest computed tomography (CT) scans on a CT simulator with images acquired at the same phase of patients' respiratory cycle. Computed tomography scans were obtained at the time of planning CT scan and 3 times a week during radiotherapy (RT). Gross tumor volumes (GTVs) were contoured on each CT scan. Gross tumor volumes defined on each CT scan were analyzed for volume changes relative to pre-RT scans. Results: We obtained 104 CT scans (median, 11.5 scans per patient). The median tumor dose was 50 Gy. The median pre-RT GTV was 98.9 cm{sup 3} (range, 57.8-412.4 cm{sup 3}). The median GTV at the final serial CT scan was 10.0 cm{sup 3} (range, 4.2-81.6 cm{sup 3}). The mean GTV relative to pre-RT volume at the end of each RT week was 53.0% for Week 1, 29.8% for Week 2, 22.9% for Week 3, 19.5% for Week 4, and 12.4% for Week 5. Conclusions: Dramatic shrinkage of small-cell lung tumors occurred in patients undergoing chemoradiotherapy in this trial. Most of the observed GTV shrinkage occurred during the first week of RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Character and Spatial Distribution of Threading Edge Dislocations in 4H-SiC Epilayers by High-Resolution Topography

Topography image variation of threading edge dislocations (TEDs) in 4H-SiC epilayers has been investigated by grazing incidence high-resolution synchrotron topography. Six different images of TEDs resulting from an angle between the diffraction vector and the TED Burgers vector were confirmed by correlation between experimental topography images and simulation results. The TED-type distribution, dependent on the direction of the TED Burger vector, was examined on epitaxial wafers, while the spatial distribution of TEDs on a whole 2 in wafer along [1 1 2 0] and [1 1 0 0] was investigated.

36 MATERIALS SCIENCE↗

Evaluation of sequence tracking methods for Compton cameras based on CdZnTe arrays

In this study, the performance of sequence tracking methods for multiple interaction events in specific CdZnTe Compton imagers was evaluated using Monte Carlo simulations. The Compton imager consisted of a 6 × 6 array of virtual Frisch-grid CZT crystals, where the dimensions of each crystal were 5 × 5 × 12 mm 3 . The sequence tracking methods for another Compton imager that consists of two identical CZT crystals arrays were also evaluated. When 662 keV radiation was incident on the detectors, the percentages of the correct sequences determined by the simple comparison and deterministic methods for two sequential interactions were identical (~80 %), while those evaluated using the minimum squared difference method (55-59 %) and Three Compton method (45-55 %) for three sequential interactions, differed from each other. The reconstructed images of a 662 keV point source detected using single and double arrays were evaluated based on their angular resolution and signal-to-noise ratio, and the results showed that the double arrays outperformed single arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical neutron damage calculations in industrial robotic manipulators used for non-destructive imaging applications

Our paper describes how to use MCNP to evaluate the rate of material damage in a robot incurred by exposure to a neutron flux. The example used in this work is that of a robotic manipulator installed in a high intensity, fast, and collimated neutron radiography beam port at the University of Texas at Austin's TRIGA Mark II research reactor. Our effort includes taking robotic technologies and using them to automate non-destructive imaging tasks in nuclear facilities where the robotic manipulator acts as the motion control system for neutron imaging tasks. Simulated radiation tests are used to analyze the radiation damage to the robot. Once the neutron damage is calculated using MCNP, several possible shielding materials are analyzed to determine the most effective way of minimizing the neutron damage. Furthermore, neutron damage predictions provide users the means to simulate geometrical and material changes, thus saving time, money, and energy in determining the optimal setup for a robotic system installed in a radiation environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

H 2 Pc and pentacene on Cu(110)-(2×1)O: A combined STM and nc-AFM study

Scanning tunneling microscopy (STM) and non-contact atomic force microscopy (nc-AFM) with a CuO tip is used to investigate adsorption of metal-free phthalocyanine (H 2 Pc) and pentacene on the Cu(110)-(2×1)O striped-phase reconstructed surface. We show that the combination of STM and nc-AFM is necessary to reveal the detailed adsorption geometry, necessary for interpreting the observed STM contrast. Comparison of the nc-AFM images with simulations shows that some of the H 2 Pc molecules are deformed out-of-plane on this surface, while pentacene retains its molecular geometry regardless of adsorption site. Our research highlights how the stiffness of CuO tips makes it possible to probe the structure of organic semiconductor / metal interfaces.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Scattering Matrix Determination in Crystalline Materials from 4D Scanning Transmission Electron Microscopy at a Single Defocus Value

Recent work has revived interest in the scattering matrix formulation of electron scattering in transmission electron microscopy as a stepping stone toward atomic-resolution structure determination in the presence of multiple scattering. Here, we discuss ways of visualizing the scattering matrix that make its properties clear. Through a simulation-based case study incorporating shot noise, we shown how regularizing on this continuity enables the scattering matrix to be reconstructed from 4D scanning transmission electron microscopy (STEM) measurements from a single defocus value. Intriguingly, for crystalline samples, this process also yields the sample thickness to nanometer accuracy with no a priori knowledge about the sample structure. The reconstruction quality is gauged by using the reconstructed scattering matrix to simulate STEM images at defocus values different from that of the data from which it was reconstructed.

36 MATERIALS SCIENCE↗