Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down to <1 s, in principle), but also higher optical throughput, thus resulting in a substantial increase in measurement SNR.

Nguyen, Quang-Viet↗

Near-infrared Reflectance of Rocks at high Temperature: Preliminary Results and Implications for Near-infrared Emissivity of Venus's Surface

Light emitted from Venus’s surface can be viewed through spectral “windows” in its atmosphere, in the nearinfrared (NIR) around 1000 nanometer (nm) wavelengths. The NIR emissivity of Venus’s surface can constrain rock types and their weathering state; emissivities can be measured directly or calculated from reflectances. We measured the reflectances of igneous and sedimentary rocks at Venus’s surface temperature, 400 °C–500 °C at 850 and 950 nm; samples were heated in a box furnace in air, illuminated by light-emitting diodes (LEDs), and imaged with a modified charge-coupled device (CCD) camera. Reflectances were also measured at 25 °C from 350 to 1400 nm. Rock reflectances at 850 and 950 nm and 400 °C–500 °C are nearly identical to those at 25 °C, except for the effects of nanophase hematite forming on some surfaces. Fresh basalts have reflectances (high and low temperatures) near 7.5%; a leucogranite similarly has reflectances near 50%. Pigmentary hematite has nearly identical reflectances at high- and low-temperature at these wavelengths. Pigmentary hematite appears dark brown 400 °C–500 °C because its absorption edge has shifted to beyond the limit of human vision. These rock reflectances imply that basalts should have emissivities near 0.9, and granite (and similar felsic rocks) should have lower emissivities ∼0.5. Thus, basalt and felsic rock should be easily distinguished in NIR emissivity measurements of Venus’s surface, such as are baselined in recent Venus mission proposals. Other sedimentary rocks should have even lower emissivities: quartz sand at around ∼0.3, and anhydrite as low as 0.1.

Allan H Treiman↗

Effect of Te Inclusions on Internal Electric Field of CdMnTe Gamma-Ray Detectors

We studied two separate as-grown CdMnTe crystals by Infrared (IR) microscopy and Pockels effect imaging, and then developed an algorithm to analyze and visualize the electric field within the crystals’ bulk. In one of the two crystals the size and distribution of inclusions within the bulk promised to be more favorable in terms of efficiency as a detector crystal. However, the Te inclusions were arranged in characteristic ‘planes’. Pockels imaging revealed an accumulation of charges in the region of these planes. We demonstrated that the planes induced stress within the bulk of the crystal that accumulated charges, thereby causing non-uniformity of the internal electric field and degrading the detector’s performance.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Harmonic arbitrary waveform generator

High frequency arbitrary waveforms have applications in radar, communications, medical imaging, therapy, electronic warfare, and charged particle acceleration and control. State of the art arbitrary waveform generators are limited in the frequency they can operate by the speed of the Digital to Analog converters that directly create their arbitrary waveforms. The architecture of the Harmonic Arbitrary Waveform Generator allows the phase and amplitude of the high frequency content of waveforms to be controlled without taxing the Digital to Analog converters that control them. The Harmonic Arbitrary Waveform Generator converts a high frequency input, into a precision, adjustable, high frequency arbitrary waveform.

47 OTHER INSTRUMENTATION↗

The response function of Fujifilm BAS-TR imaging plates to laser-accelerated titanium ions

Calibrated diagnostics for energetic particle detection allow for the systematic study of charged particle sources. The Fujifilm BAS-TR imaging plate (IP) is a reusable phosphorescent detector for radiation applications such as x-ray and particle beam detection. The BAS-TR IP has been absolutely calibrated to many low-Z (low proton number) ions, and extending these calibrations to the mid-Z regime is beneficial for the study of laser-driven ion sources. The Texas Petawatt Laser was used to generate energetic ions from a 100 nm titanium foil, and charge states Ti 10+ through Ti 12+ , ranging from 6 to 27 MeV, were analyzed for calibration. A plastic detector of CR-39 with evenly placed slots was mounted in front of the IP to count the number of ions that correspond with the IP levels of photo-stimulated luminescence (PSL). Here, a response curve was fitted to the data, yielding a model of the PSL signal vs ion energy. Comparisons to other published response curves are also presented, illustrating the trend of PSL/nucleon decreasing with increasing ion mass.

47 OTHER INSTRUMENTATION↗

Monitoring Both Sides Of A Weld In Progress

Proposed remote vision system provides simultaneous viewing of front and back of workpiece while being welded. Enables human or automatic controller to monitor both weld pool on front and weld penetration on back. Nitrogen laser generates ultraviolet light, distributed to both sides of workpiece through two optical fiber cables. Image-intensifier tubes convert reflected ultraviolet light to visible light. Video cameras equipped with high-resolution charge-coupled devices convert visible outputs of image intensifiers into images for viewing on video monitors.

Dickinson, C. B.↗

Multimodal imaging and machine learning to enhance microscope images of shale

A machine learning based image processing workflow is presented to enhance shale source rock microscopic images obtained using diverse imaging platforms. Images were acquired from a 30 μm diameter cylindrical Vaca Muerta shale sample using both nondestructive Transmission X-Ray Microscopy (TXM, alternately referred to as nano computed tomography) and destructive Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM). Output cross-sectional images from each modality were aligned using a combination of manual and automated registration techniques to create a registered image dataset. We then apply this dataset for two image processing tasks: prediction of image cross sections with SEM-like resolution from nondestructive TXM data and repair of charged region artifacts (localized accumulation of electrons) within SEM images. The image processing algorithms for both tasks use deep learning models, specifically image-to-image Convolutional Neural Networks (CNNs) and conditional Generative Adversarial Networks (cGANs). In the image enhancement tasks, we are able to achieve significant qualitative and quantitative improvement in TXM images. Here, the best model reaches an average Peak Signal to Noise Ratio (PSNR) of 15.8 dB. Conditioning on TXM data is also shown to reduce artifacts from SEM charging, achieving an average PSNR of 25.8 dB. Furthermore, our results suggest that properly trained and validated networks are capable of significant enhancement of images obtained using nondestructive techniques, thereby improving interpretation of two- and three-dimensional images while preserving samples for future use.

58 GEOSCIENCES↗

Luminescence imaging of water during carbon-ion irradiation for range estimation

Purpose: The authors previously reported successful luminescence imaging of water during proton irradiation and its application to range estimation. However, since the feasibility of this approach for carbon-ion irradiation remained unclear, the authors conducted luminescence imaging during carbon-ion irradiation and estimated the ranges. Methods: The authors placed a pure-water phantom on the patient couch of a carbon-ion therapy system and measured the luminescence images with a high-sensitivity, cooled charge-coupled device camera during carbon-ion irradiation. The authors also carried out imaging of three types of phantoms (tap-water, an acrylic block, and a plastic scintillator) and compared their intensities and distributions with those of a phantom containing pure-water. Results: The luminescence images of pure-water phantoms during carbon-ion irradiation showed clear Bragg peaks, and the measured carbon-ion ranges from the images were almost the same as those obtained by simulation. The image of the tap-water phantom showed almost the same distribution as that of the pure-water phantom. The acrylic block phantom’s luminescence image produced seven times higher luminescence and had a 13% shorter range than that of the water phantoms; the range with the acrylic phantom generally matched the calculated value. The plastic scintillator showed ∼15 000 times higher light than that of water. Conclusions: Luminescence imaging during carbon-ion irradiation of water is not only possible but also a promising method for range estimation in carbon-ion therapy.

60 APPLIED LIFE SCIENCES↗

Event-driven charge-coupled device design and applications therefor

An event-driven X-ray CCD imager device uses a floating-gate amplifier or other non-destructive readout device to non-destructively sense a charge level in a charge packet associated with a pixel. The output of the floating-gate amplifier is used to identify each pixel that has a charge level above a predetermined threshold. If the charge level is above a predetermined threshold the charge in the triggering charge packet and in the charge packets from neighboring pixels need to be measured accurately. A charge delay register is included in the event-driven X-ray CCD imager device to enable recovery of the charge packets from neighboring pixels for accurate measurement. When a charge packet reaches the end of the charge delay register, control logic either dumps the charge packet, or steers the charge packet to a charge FIFO to preserve it if the charge packet is determined to be a packet that needs accurate measurement. A floating-diffusion amplifier or other low-noise output stage device, which converts charge level to a voltage level with high precision, provides final measurement of the charge packets. The voltage level is eventually digitized by a high linearity ADC.

Doty, John P.↗

Experiments on bright-field and dark-field high-energy electron imaging with thick target material

High-energy charged particle radiography has been used for diagnostics of high-energy density matter, and electrons can serve as a promising radiographic probe that acts as a complement to commonly used proton probes. Here we report on an electron radiography experiment using 45 MeV electrons from an S-band photoinjector, where scattered electrons, after interacting with a sample, are collected and imaged by a quadrupole imaging system. We achieve a spatial resolution of a few microns (similar to 4 μm) and a thickness resolution of a few percent for a silicon target of 300-600 μm in thickness. With additional dark-field images captured by selecting electrons with large scattering angles, we show that complementary information for determining external details such as outlines, boundaries and defects can be obtained.

Zhou, Zheng↗

Atomic bonding effects in annular dark field scanning transmission electron microscopy. I. Computational predictions

Annular dark field scanning transmission electron microscopy (ADF-STEM) image simulations were performed for zone-axis-oriented light-element single crystals, using a multislice method adapted to include charge redistribution due to chemical bonding. Examination of these image simulations alongside calculations of the propagation of the focused electron probe reveal that the evolution of the probe intensity with thickness exhibits significant sensitivity to interatomic charge transfer, accounting for observed thickness-dependent bonding sensitivity of contrast in all ADF-STEM imaging conditions. Because changes in image contrast relative to conventional neutral atom simulations scale directly with the net interatomic charge transfer, the strongest effects are seen in crystals with highly polar bonding, while no effects are seen for nonpolar bonding. Although the bonding dependence of ADF-STEM image contrast varies with detector geometry, imaging parameters, and material temperature, these simulations predict the bonding effects to be experimentally measureable.

42 ENGINEERING↗

Design and Characterization of a Burst Mode 20 Mfps Low Noise CMOS Image Sensor

This paper presents a novel ultra-high speed, high conversion-gain, low noise CMOS image sensor (CIS) based on charge-sweep transfer gates implemented in a standard 180 nm CIS process. Through the optimization of the photodiode geometry and the utilization of charge-sweep transfer gates, the proposed pixels achieve a charge transfer time of less than 10 ns without requiring any process modifications. Moreover, the gate structure significantly reduces the floating diffusion capacitance, resulting in an increased conversion gain of 183 µV/e−. This advancement enables the image sensor to achieve the lowest reported noise of 5.1 e− rms. To demonstrate the effectiveness of both optimizations, a proof-of-concept CMOS image sensor is designed, taped-out and characterized.

47 OTHER INSTRUMENTATION↗

Study of azimuthal anisotropy of $\Upsilon$ (1S) mesons in pPb collisions at $\sqrt{S_{NN}}$ = 8.16 TeV

The azimuthal anisotropy of Image 1 mesons in high-multiplicity proton-lead collisions is studied using data collected by the CMS experiment at a nucleon-nucleon center-of-mass energy of 8.16 TeV. The Image 1 mesons are reconstructed using their dimuon decay channel. The anisotropy is characterized by the second Fourier harmonic coefficients, found using a two-particle correlation technique, in which the Image 1 mesons are correlated with charged hadrons. A large pseudorapidity gap is used to suppress short-range correlations. Nonflow contamination from the dijet background is removed using a low-multiplicity subtraction method, and the results are presented as a function of Image 1 transverse momentum. The azimuthal anisotropies are smaller than those found for charmonia in proton-lead collisions at the same collision energy, but are consistent with values found for Image 1 mesons in lead-lead interactions at a nucleon-nucleon center-of-mass energy of 5.02 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-speed mapping of surface charge dynamics using sparse scanning Kelvin probe force microscopy

Unraveling local dynamic charge processes is vital for progress in diverse fields, from microelectronics to energy storage. This relies on the ability to map charge carrier motion across multiple length- and timescales and understanding how these processes interact with the inherent material heterogeneities. Towards addressing this challenge, we introduce high-speed sparse scanning Kelvin probe force microscopy, which combines sparse scanning and image reconstruction. This approach is shown to enable sub-second imaging (>3 frames per second) of nanoscale charge dynamics, representing several orders of magnitude improvement over traditional Kelvin probe force microscopy imaging rates. Bridging this improved spatiotemporal resolution with macroscale device measurements, we successfully visualize electrochemically mediated diffusion of mobile surface ions on a LaAlO 3 /SrTiO 3 planar device. Such processes are known to impact band-alignment and charge-transfer dynamics at these heterointerfaces. Furthermore, we monitor the diffusion of oxygen vacancies at the single grain level in polycrystalline TiO 2 . Through temperature-dependent measurements, we identify a charge diffusion activation energy of 0.18 eV, in good agreement with previously reported values and confirmed by DFT calculations. Together, these findings highlight the effectiveness and versatility of our method in understanding ionic charge carrier motion in microelectronics or nanoscale material systems.

25 ENERGY STORAGE↗

EUV Imaging of SWCX-Produced He(+) 30.4-nm Emission/Scattering at the Magnetosheath

Theoretically, charge exchange between solar wind alpha-particles and geocoronal hydrogen at the magnetosheath results in the production of helium ions in an excited state, i.e, He(2+) + H (right arrow) He(+*) + H(+) resulting in the emission of 30.4-nm radiation upon relaxation of the helium ions. It has been estimated that the magnetosphere was compressed to inside the orbit of IMAGE during the Halloween storm of 2003. This configuration should have placed the subsolar point of the magnetosheath well beyond the limb of the solar disk and allow EUV the potential of imaging this solar wind charge exchange interaction Analysis of EUV full-frame data acquired during 31 October 2003 (Day 304) indicates the detection of 30.4-nm photons in the likely vicinity of the magnetosheath either as a direct consequence of the emission proposed above or, provided the magnetosheath He(+) density was sufficient to exceed the EUV sensitivity threshold, via resonant scattering of solar UV. We present initial analysis of EUV imaging during the Halloween 2003 storm from the context of solar wind parameters, including composition, and from the perspective of the generation of simulated EUV imaging of the event both as an emitting and as a scattering process.

Adrian, M. L.↗

Direct Imaging of the Structural and Morphological Evolution of Epitaxial LiCoO 2 Films during Charge and Overcharge

The capacity decay of layered cathodes in high-voltage applications underscores the need to utilize accurate and precise techniques to understand the underlying mechanisms. Here, we use well-defined epitaxial LiCoO 2 (LCO) films on SrRuO 3 /SrTiO 3 (SRO/STO) with controlled orientations and defect structures along with in situ electrochemical atomic force microscopy to probe the structural and morphological evolutions during the charge and overcharge processes. We quantitatively show the morphological changes in both the reversible delithiation regime and the irreversible over-delithiation regime and correlate the overall electrochemical behaviors to atomic scale defect evolutions in the films. Further, we also observe a significantly lower charging capacity for LCO/SRO/STO(111) compared to that of LCO/SRO/STO(001) films of the same thickness, which is ascribed to different types of atomic scale defects formed during the film growth process. Our high- resolution scanning transmission electron microscopy (STEM) and electron energy loss spectroscopy (EELS) studies reveal that the antiphase boundaries in LCO/SRO/STO(111) act as viable channels for Li migration but are more susceptible to irreversible phase transitions, which then block subsequent Li diffusion. The failure mechanisms developed here may provide insight into the design of future cathode materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Destructive Monitoring of Charge-Discharge Cycles on Lithium Ion Batteries using 7 Li Stray-Field Imaging

Magnetic resonance imaging provides a noninvasive method for in situ monitoring of electrochemical processes involved in charge/discharge cycling of batteries. Determining how the electrochemical processes become irreversible, ultimately resulting in degraded battery performance, will aid in developing new battery materials and designing better batteries. Here we introduce the use of an alternative in situ diagnostic tool to monitor the electrochemical processes. Utilizing a very large field-gradient in the fringe field of a magnet, stray-field-imaging (STRAFI) technique significantly improves the image resolution. These STRAFI images enable the real time monitoring of the electrodes at a micron level. It is demonstrated by two prototype half-cells, graphite &parallel;Li and LiFePO 4 &parallel; Li, that the high-resolution 7 Li STRAFI profiles allow one to visualize in situ Li-ions transfer between the electrodes during charge/discharge cyclings as well as the formation and changes of irreversible microstructures of the Li components, and particularly reveal a non-uniform Li-ion distribution in the graphite.

25 ENERGY STORAGE↗