Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high - contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Synthetic Foveal Imaging Technology

Synthetic Foveal imaging Technology (SyFT) is an emerging discipline of image capture and image-data processing that offers the prospect of greatly increased capabilities for real-time processing of large, high-resolution images (including mosaic images) for such purposes as automated recognition and tracking of moving objects of interest. SyFT offers a solution to the image-data processing problem arising from the proposed development of gigapixel mosaic focal-plane image-detector assemblies for very wide field-of-view imaging with high resolution for detecting and tracking sparse objects or events within narrow subfields of view. In order to identify and track the objects or events without the means of dynamic adaptation to be afforded by SyFT, it would be necessary to post-process data from an image-data space consisting of terabytes of data. Such post-processing would be time-consuming and, as a consequence, could result in missing significant events that could not be observed at all due to the time evolution of such events or could not be observed at required levels of fidelity without such real-time adaptations as adjusting focal-plane operating conditions or aiming of the focal plane in different directions to track such events. The basic concept of foveal imaging is straightforward: In imitation of a natural eye, a foveal-vision image sensor is designed to offer higher resolution in a small region of interest (ROI) within its field of view. Foveal vision reduces the amount of unwanted information that must be transferred from the image sensor to external image-data-processing circuitry. The aforementioned basic concept is not new in itself: indeed, image sensors based on these concepts have been described in several previous NASA Tech Briefs articles. Active-pixel integrated-circuit image sensors that can be programmed in real time to effect foveal artificial vision on demand are one such example. What is new in SyFT is a synergistic combination of recent advances in foveal imaging, computing, and related fields, along with a generalization of the basic foveal-vision concept to admit a synthetic fovea that is not restricted to one contiguous region of an image.

Hoenk, Michael↗

A Broadband X-Ray Imaging Spectroscopy with High-Angular Resolution: the FORCE Mission

We are proposing FORCE (Focusing On Relativistic universe and Cosmic Evolution) as a future Japan-lead X-ray observatory to be launched in the mid 2020s. Hitomi (ASTRO-H) possesses a suite of sensitive instruments enabling the highest energy-resolution spectroscopy in soft X-ray band, a broadband X-ray imaging spectroscopy in soft and hard X-ray bands, and further high energy coverage up to soft gamma-ray band. FORCE is the direct successor to the broadband X-ray imaging spectroscopy aspect of Hitomi (ASTRO-H) with significantly higher angular resolution. The current design of FORCE defines energy band pass of 1-80 keV with angular resolution of <15" in half-power diameter, achieving a 10 times higher sensitivity above 10 keV compared to any previous missions with simultaneous soft X-ray coverage. Our primary scientific objective is to trace the cosmic formation history by searching for "missing black holes" in various mass-scales: "buried supermassive black holes (SMBHs)" (> 10(exp 4) Stellar Mass) residing in the center of galaxies in a cosmological distance, "intermediate-mass black holes" (10(exp 2)-(10(exp 4) Stellar Mass) acting as the possible seeds from which SMBHs grow, and "orphan stellar-mass black holes" (< 10(exp 2) Stellar Mass) without companion in our Galaxy. In addition to these missing BHs, hunting for the nature of relativistic particles at various astrophysical shocks is also in our scope, utilizing the broadband X-ray coverage with high angular-resolution. FORCE are going to open a new era in these fields. The satellite is proposed to be launched with the Epsilon vehicle that is a Japanese current solid-fuel rocket. FORCE carries three identical pairs of Super-mirror and wide-band X-ray detector. The focal length is currently planned to be 10 m. The silicon mirror with multi-layer coating is our primary choice to achieve lightweight, good angular optics. The detector is a descendant of hard X-ray imager onboard Hitomi (ASTRO-H) replacing its silicon strip detector with SOI-CMOS silicon pixel detector, allowing an extension of the low energy threshold down to 1 keV or even less.

Hard X-ray↗

High-resolution continuum and Br (gamma) imaging observations of M82

We report high angular resolution (about 0.6 sec), broad-band imaging at 1.2 microns (J band), 1.6 microns (H band), 2.2 microns (K band), and 3.7 microns (L' band) of the central 110 sec x 21 sec (1.65 kpc x 0.32 kpc) of the nearby starburst galaxy M82. We also present spectral imaging with 90 km/s resolution in the Br (gamma) (2.17 microns) hydrogen recombination line covering the central 16 sec x 16 sec (240 pc x 240 pc) of this edge-on, disk galaxy. The broad-band mosaics reveal two plateaus of emission indicative of an inner disk of stars and perhaps a larger bar structure. Color maps reveal an extinction ridge running along the central kiloparsec which is strongest at the nucleus and on the western side. The dust emission is more symmetric, suggesting that a dust lane is in front of the stellar population to the west of the nucleus, and behind the stars to the east; this is again suggestive of a stellar bar with leading dust lanes. Channel maps and a position-velocity image of the Br (gamma) reveal two lobes and are consistent with the interpretation that the ionized gas, and hence, the young massive stars are distributed in a toroid of H II regions surrounding the nucleus.

Larkin, J. E.↗

Multifrequency imaging radar polarimetry: Depolarisation of radar echoes at three wavelengths

It is shown that high resolution imaging radar polarimeters can describe depolarization effects in great detail by measuring the complete Stokes matrix for small regions on the Earth's surface, permitting to distinguish between coherent polarization transformation by the surface and diffuse interactions that randomize the polarization state of the received wave. Multiwavelength polarimeter observations of a variety of types of terrain, including images of the coherent and diffuse parts of the received signal are presented. The diffuse image, in particular, is highly indicative of small-scale surface roughness, an effect illustrated by analyzing a set of polarimeter images acquired over lava fields of varying roughness.

Zebker, H. A.↗

Diffraction limited infrared images of the binary star T Tauri

High-resolution images of T Tau and its infrared companion have been reconstructed from near- and midinfrared data collected at the Hale 5-m telescope. The near-infrared (1-5 microns) results were obtained by 2D speckle imaging and the midinfrared (10-20 microns) results were derived from shift-and-add procedures applied to slit scans. The spectral energy distributions of the separated components were constructed from 1- to 20-micron data collected in less than half a year (September 1990 to January 1991). The spectral energy distribution of the optical component (T Tau N) is interpreted as containing two distinct constituents, a photosphere and a surrounding disk of circumstellar material. Measurements at a number of infrared wavelengths over the period December 1985 to January 1991 show a 2-mag color-independent change in the brightness of the infrared component (T Tau S). It is proposed that this may have been caused by an increase in accretion onto T Tau S and model the spectral energy distribution of T Tau S as being dominated by an accretion disk.

Ghez, A. M.↗

High-speed electromechanical chutter for imaging spectrographs

The present invention presents a high-speed electromechanical shutter which has at least two rotary beam choppers that are synchronized using a phase-locked loop electronic control to reduce the duty cycle. These choppers have blade means that can comprise discs or drums, each having about 60 (+/- 15) slots which are from about 0.3 to about 0.8 mm wide and about 5 to about 20 nun long (radially) which are evenly distributed through out 360 deg, and a third rotary chopper which is optically aligned has a small number of slots, such as for example, 1 to 10 slots which are about 1 to about 2 mm wide and about 5 to about 20 mm long (radially). Further the blade means include phase slots that allow the blade means to be phase locked using a closed loop control circuit. In addition, in a preferred embodiment, the system also has a leaf shutter. Thus the invention preferably achieves a gate width of less than about 100 microseconds, using motors that operate at 3000 to 10,OOO rpm, and with a phase jitter of less than about 1.5 microseconds, and further using an aperture with more than about 75% optical transmission with a clear aperture of about 0.8 -10 nun. The system can be synchronized to external sources at 0 6 kHz lasers, data acquisition systems, and cameras.

Quang-Viet Nguyen↗

High-speed electromechanical shutter for imaging spectrographs

The present invention presents a high-speed electromechanical shutter which has at least two rotary beam choppers that are synchronized using a phase-locked loop electronic control to reduce the duty cycle. These choppers have blade means that can comprise discs or drums, each having about 60 (+/-15) slots which are from about 0.3 to about 0.8 mm wide and about 5 to about 20 mm long (radially) which are evenly distributed through out 360?, and a third rotary chopper which is optically aligned has a small number of slots, such as for example, 1 to 10 slots which are about 1 to about 2 mm wide and about 5 to about 20 mm long (radially). Further the blade means include phase slots that allow the blade means to be phase locked using a closed loop control circuit. In addition, in a preferred embodiment, the system also has a leaf shutter. Thus the invention preferably achieves a gate width of less than about 100 microseconds, using motors that operate at 3000 to 10,000 rpm, and with a phase jitter of less than about 1.5 microseconds, and further using an aperture with more than about 75% optical transmission with a clear aperture of about 0.8 mm?10 mm. The system can be synchronized to external sources at 0 6 kHz lasers, data acquisition systems, and cameras.

Nguyen, Quang-Viet↗

In-situ Observations of Directed Energy Deposition Additive Manufacturing Using High-Speed X-ray Imaging

In laser-based directed energy deposition (DED) additive manufacturing, interactions among the laser beam, particle flow, and melt pool influence the properties of the solidified final part. Two separate DED systems, one with high powder flow rates to represent industrial-scale DED processing and the other with low powder flow rates for individual particle tracking, were synchronized with the high-speed imaging setup at the Advanced Photon Source in Argonne National Laboratory. In-situ x-ray imaging of the DED process using both systems highlighted the influence of powder flow rates. Increased powder flow rates resulted in less laser absorption into the melt pool, leading to a transition from a keyhole mode to a melt pool without a keyhole but with surface fluctuations due to powder flow. Increased velocities of particles during powder flow resulted in a decrease in particle melting times and a greater propensity for porosity formation. Altogether, better understanding of the interactions that occur during various scales of the DED process will enable flexibility, control, and new materials development in DED-based additive manufacturing.

36 MATERIALS SCIENCE↗

Material Characterization of Grade 91 Steel Welds using, Micro-resolution Ultrasonic Imaging System

Grade 91 (9Cr-1Mo-V) steel is a common structural material for fossil-fuel fired and nuclear power plants because of its creep strength and oxidation resistance at high temperatures. In this research, we studied the feasibility of correlating the high-resolution images obtained from the immersion ultrasonic imaging technique to microstructure regions in Grade 91 steel plate weldments. The high-resolution ultrasonic images presented in this paper were generated using a 20-MHz focused transducer as the transmitter, and a laser vibrometer as the receiver in the through transmission configuration to produce longitudinal and shear waves. This nondestructive evaluation (NDE) method was used to identify the Fusion Zone (FZ), Heat-Affected Zone (HAZ), and Base Metal (BM) regions of Grade 91 cold metal transfer (CMT) and flux core arc welds (FCAW). The ultrasonic imaging results were analyzed using beam propagation amplitudes and homogeneity, which in turn were used to relate the different microstructure regions of the FCAW and CMT welded samples. With this study, we were able to identify highly susceptible microstructures in the weld that could potentially promote creep type failures.

20 FOSSIL-FUELED POWER PLANTS↗

Argon broad ion beam sectioning and high resolution scanning electron microscopy imaging of hydrated alite

Highlights: • The native fibrous outer and dense inner C-S-H structure are preserved by using low energy argon broad ion beam sectioning. • Possible artefacts of the preparation and imaging of hydrated alite are shown and discussed. • An approach for a semi automated pore analysis of the obtained high resolution images is demonstrated. Scanning electron microscopy (SEM) imaging is able to visualize micro- to nano-structures of cement and concrete. A prerequisite is that the sample preparation preserves the native structure of the specimen. In this study, argon broad ion beam (BIB) sectioning is compared to state-of-the-art sample preparation (resin embedding, polishing) for hydrated alite. Additionally, it is investigated if during BIB, sample cooling is beneficial to avoid deterioration of cement hydrates. The aim is to quantitatively measure pore size distributions in hardened alite pastes. Therefore, not only optimized sample preparation but also optimized imaging conditions are investigated. Finally, it is demonstrated that by image analysis pores down to a diameter of 5 nm in hydrated alite pastes can be quantitatively analysed.

36 MATERIALS SCIENCE↗

Zero-Power Analog Optical Processing

The motivation behind this research is the growing challenge of handling the massive amounts of data generated by modern imaging systems. Conventional digital image processing techniques are struggling to keep pace with the demands of high-resolution and high-speed imaging systems for remote sensing due to their high-power consumption and data storage requirements. We present a novel approach based on analog photonics to address this challenge. The proposed system utilizes a silicon-photonics-based image encoder positioned after image formation and initial optical-to-electrical conversion. The photonic encoder compresses image data using a passive disordered photonic structure to perform kernel-type random projections of the raw data. The compressed data is then processed by a back-end neural network, which reconstructs the original image with high fidelity (structural similarity exceeding 90%). Our proposed approach has the potential to compress images with ~ 1000X lower power consumption compared to digital approaches with data rates exceeding 1 terapixel/second.

97 MATHEMATICS AND COMPUTING↗

A new study of the interacting binary star V356 Sgr

Results on V356 Sgr from IUE and Voyager ultraviolet (500 to 3200 A) observations obtained in 1986 and 1987, primarily during 2 total eclipses are presented. The eclipse of Aug. 15, 1986 was fully covered with IUE low dispersion images and 9 hr of Voyager UVS data. The eclipse of Mar. 25, 1987 was covered with IUE low dispersion images and 1 high dispersion SWP image. During both eclipses the total strength of the emission lines is found to be invariant. An uneclipsed UV continuum is detected at wavelengths shorter than 1500 A. The high dispersion SWP spectrum reveals that the emission lines are extremely broad, almost symmetrical emissions with weak, slightly blue shifted absorption components. No evidence of carbon, C I, C II, C III, or C IV, is seen in the emission or absorption spectrum of V356 Sgr in eclipse. Models for this binary system are presented.

Polidan, R. S.↗

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

High resolution near-infrared imaging of the trapezium: A stellar census

We present high spatial resolution (0.35 and 0.65 arcsec full width at half maximum (FWHM)) near-infrared images of the central 0.2x0.2 pc of the Trapezium Cluster in the Orion Nebula, centered on the Trapezium OB stars. These images provide the most complete census of stars in this region, and we give accurate positions and near-infrared (2.1 microns) magnitudes for 123 stars. After accounting for line-of-sight projection, we estimate a stellar density for the cluster of approximately 4.7 X 10(exp 4) stars per cubic parsec in the approximately 0.1 pc diameter core. We identify stellar counterparts to virtually all the known dense knots of ionized gas seen at optical and radio wavelengths, strongly supporting the hypothesis that many are either intrinsic stellar radio emitters or circumstellar disks around stars, and not simply dense clumps of gas and dust. We derive approximate masses for the stars associated with the compact knots, finding that the majority are relatively low mass.

Mccaughrean, Mark J.↗

Multimode Data-Compression System

Data-compression system developed to satisfy need for high-speed, high-performance compression of data from sources as diverse as medical images, high-definition television images, audio signals, readouts from scientific instruments, and binary data files. Maximum data-transmission capability of communication channel or storage capacity of storage device multiplied by approximately compression ratio. Various combinations of lossless and lossy compression chosen to suit various data streams.

Fang, Wai-Chi↗

Global Multimodal Dataset for Nighttime Light Super-Resolution

The dataset is a collection of spatially and temporally registered high-resolution and low-resolution nighttime light (NTL) images, high-resolution land-use binary masks, and high-resolution road density images from around the world. The NTL images are sourced from the NASA Black Marble product VNP46A2 and the LuoJia1-01 satellite. The land-use binary masks are derived from Google's and the World Resources Institute's DynamicWorld dataset, and the road density images are sourced from OpenStreetMap.

Nighttime lights↗

Preparations for Tomographic Background-Oriented Schlieren at the 31-Inch Mach 10 Wind Tunnel

This paper details effort by researchers at NASA Langley Research Center to prepare for an upcoming high-speed tomographic background-oriented schlieren test entry in the 31-Inch Mach 10 wind tunnel. In order to troubleshoot potential problems that will arise when setting up the experiment in the actual test facility, a full-scale mock-up of the 31-Inch Mach 10 wind tunnel test section was constructed in the laboratory to provide equivalent characteristic optical access and mounting options. A 3D-printed model that replicates the scale of the forebody of a supersonic retropropulsion (SRP) model that will be used in the final test entry has been fabricated with a central nozzle that can be connected to a high-pressure gas supply to approximate the nozzle flow that will occur. Six high-speed imaging systems consisting of a high-speed camera with a fiber illuminator module have been assembled and mounted on the test section mock-up to provide six unique perspective views of the nozzle flow from the model. Tests with one of the imaging systems using a pulsed laser light source showed that sufficient signal intensity and illumination uniformity was achieved, as demonstrated by the 2D BOS data obtained with the system. Additional work to show that retroreflective material would survive inside of the test section of the 31-Inch Mach 10 tunnel was also performed. Finally, a remotely-controlled tomographic BOS calibration system is discussed.

Brett F Bathel↗

Development of a ground signal processor for digital synthetic array radar data

A modified APQ-102 sidelooking array radar (SLAR) in a B-57 aircraft test bed is used, with other optical and infrared sensors, in remote sensing of Earth surface features for various users at NASA Johnson Space Center. The video from the radar is normally recorded on photographic film and subsequently processed photographically into high resolution radar images. Using a high speed sampling (digitizing) system, the two receiver channels of cross-and co-polarized video are recorded on wideband magnetic tape along with radar and platform parameters. These data are subsequently reformatted and processed into digital synthetic aperture radar images with the image data available on magnetic tape for subsequent analysis by investigators. The system design and results obtained are described.

Griffin, C. R.↗