Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

PHASE CHANGE MATERIAL FOR THERMAL ENERGY STORAGE IN BUILDINGS BASED ON SODIUM SULFATE DECAHYDRATE AND DISODIUM HYDROGEN PHOSPHATE DODECAHYDRATE

The worldwide increasing energy demand and 2050 net zero carbon target urge the globe to solve the energy challenge. Thermal Energy Storage (TES) has received significant attention in recent years as TES can be integrated into heating, ventilation, and air-conditioning systems where the energy would be stored during low-demand times and dispatched during high-demand times, resulting in controlling the peak load and improving energy savings. Material development is an integral part of TES. Salt hydrates are appealing due to cost-effectiveness, low- to no toxicity, and their high melting enthalpy, where energy is stored as latent heat. However, most salt hydrates are prone to incongruent melting (i.e., phase separation upon melting), which results in poor stability and large supercooling. In this study, we produced a highly stable novel energy storage material at a composition of 32 wt% sodium sulfate decahydrate, 52 wt% sodium phosphate dibasic dodecahydrate, 12 wt% milled expanded graphite, and 4 wt% borax. The material has a melting temperature of 28°C and an energy storage capacity of 167 kJ/kg with a supercooling of less than 3°C. The system showed no loss in energy storage performance after 150 cycles. The findings suggest that the novel energy storage material developed in this might be utilized in building heating and cooling applications.

Turnaoglu, Tugba↗

Summary of the 6th AIAA Propulsion Aerodynamics Workshop Nozzle Test Case: Heated Supersonic Axisymmetric Jets

This paper summarizes findings from the sixth AIAA Propulsion Aerodynamics Workshop (PAW) nozzle test case. The focus of the workshop participants was turbulent supersonic round jets with variation in jet Mach number and jet heating. Three nozzles were utilized with on-design jet Mach numbers of 1.36, 1.63, and 2.00. A heated jet for each of these three nozzles at on-design conditions, a temperature matched on-design condition at Mach 1.63, and an off-design heated condition for the Mach 1.63 nozzle were the five cases examined. Workshop participants utilized Reynolds-averaged Navier-Stokes (RANS) and Large Eddy Simulation (LES) based techniques. Computational fluid dynamics (CFD) solutions were compared with non-intrusive measurements of velocities and temperatures, including both mean values and turbulence statistics. In general, the RANS approaches were unable to capture the trend of reduced mixing as the jet Mach number increased. Incorporation of compressibility corrections improved the agreement with experimental measurements in terms of trends with varying jet Mach number, but also increased the jet potential core lengths to be in worse agreement with data. RANS methods were able to reasonably capture trends of jet heating. The LES-based approaches as a whole were able to capture the effects of compressibility more accurately. Effects of jet heating were captured well by LES. None of the LES approaches introduced disturbances from the wall boundary layers of the nozzle into the jet mixing layer, which would affect the jet flow physics modeling in the initial part of the jet shear layer, but would be very computationally demanding.

supersonic jet↗

Large magnetoresistance and first-order phase transition in antiferromagnetic single-crystalline EuAg 4 Sb 2

Here, we present the results of a thorough investigation of the physical properties of EuAg 4 Sb 2 single crystals using magnetization, heat capacity, and electrical resistivity measurements. High-quality single crystals, which crystallize in a trigonal structure with space group 𝑅⁢$\bar{3}$𝑚, were grown using a conventional flux method. Temperature-dependent magnetization measurements along different crystallographic orientations confirm two antiferromagnetic phase transitions around 𝑇 𝑁⁢1 = 10.5K and 𝑇 𝑁⁢2 = 7.5K. Isothermal magnetization data exhibit several metamagnetic transitions below these transition temperatures. Antiferromagnetic phase transitions in EuAg 4 Sb 2 are further confirmed by two sharp peaks in the temperature-dependent heat capacity data at 𝑇 𝑁⁢1 and 𝑇 𝑁⁢2 , which shift to lower temperature in the presence of an external magnetic field. Our systematic heat capacity measurements utilizing a long-pulse and single-slope analysis technique allow us to detect a first-order phase transition in EuAg 4 Sb 2 at 7.5 K. The temperature-dependent electrical resistivity data also manifest two features associated with magnetic order. The magnetoresistance exhibits a broad hump due to a field-induced metamagnetic transition. Remarkably, the magnetoresistance keeps increasing without showing any tendency to saturate as the applied magnetic field increases, and it reaches ∼20 000% at 1.6 K and 60 T. At high magnetic fields, several magnetic quantum oscillations are observed, indicating a complex Fermi surface. A large negative magnetoresistance of about −55% is also observed near 𝑇 𝑁⁢1 . Moreover, the 𝐻−𝑇 phase diagram constructed using magnetization, heat capacity, and magnetotransport data indicates complex magnetic behavior in EuAg 4 Sb 2 .

36 MATERIALS SCIENCE↗

Development & Experimental Validation of a Generalized Resistance-Capacitance Model for Numerical Simulation of Phase-Change Material Embedded Heat Exchangers

Latent heat thermal energy storage (LHTES) using phase change material (PCM) has attracted increased attention as a viable solution for overcoming the mismatch between energy supply and demand for renewable energy-based systems. PCM-embedded heat exchangers (PCM-HX) have the potential to significantly improve thermal performance due to high storage capacity and low temperature variation during the phase change process. Most models for simulating LHTES heat transfer use Computational Fluid Dynamics (CFD) simulations, which have high computational costs resulting from considering the complex and time-dependent physics relevant to PCM-HXs. In this paper, a Generalized Resistance Capacitance-based Model (GRCM) was developed to predict the thermal performance of arbitrary PCM-HXs in a computationally efficient manner without compromising modeling accuracy. The GRCM is exercised for three case studies: (i) verification for a single-slabbed finned PCM-HX, (ii) verification and validation for a copper foam/paraffin composite PCM-HX, and (iii) validation for a straight tube annular finned PCM-HX. The copper foam PCM-HX uses an electric heater at the top of HX, while the other two configurations utilize water as heat transfer fluid. For the single-slabbed finned PCM-HX melting case, the mean deviation in average PCM temperature predicted by the GRCM compared to the CFD model was between 0.56 – 0.73 K, with maximum temperature deviation of 2.68 K. For the HTF outlet temperature, the validation results showed that GRCM prediction matches very well with experimental data, with mean temperature deviation of 0.24 K during melting case, while for solidification case was 0.34 K. These results showcase the GRCM’s capability for accurately reproducing the thermal characteristics of PCM-HXs with considerably lower computational effort.

42 ENGINEERING↗

Calculating Behind-the-Meter Energy Storage Incentives on an Avoided Cost Basis

Behind-the-meter (BTM) energy storage offers the potential for shared investment by utilities and their customers, in which both parties share in the costs and benefits of battery investment. Several utilities and a handful of states have begun providing incentives to help customers purchase BTM energy storage, and in exchange, operate that battery on behalf of the customer to realize grid benefits such as meeting peak capacity needs. But there is wide variation in the value and structure of these incentives, suggesting a lack of clarity on the value of BTM storage to the grid and to non-participating customers who fund the incentives for participating customers. This paper provides an objective framework for establishing BTM energy storage incentives based on the avoided cost of generation from a marginal, gas-fired peaking plant. It also conducts several sensitivity analyses to see how those avoided costs vary with emissions pricing, gas prices, plant heat rates, and utility capital structures. This work may be of use to utilities, regulators, and energy system stakeholders in providing a value-based framework for BTM incentive programs that can be used in the absence of policy guidance.

Twitchell, Jeremy B.↗

Overview of Loop Heat Pipe Operation

Loop heat pipes (LHP's) are two-phase heat transfer devices that utilize the evaporation and condensation of a working fluid to transfer heat, and the capillary forces developed in the porous wicks to circulate the fluid. The LHP was first developed in the former Soviet Union in the early 1980s, about the same time that the capillary pumped loop (CPL) was developed in the United States. The LHP is known for its high pumping capability and robust operation mainly due to the use of fine-pored metal wicks and an integral evaporator/hydro-accumulator design. The LHP technology is rapidly gaining acceptance in aerospace community. It is the baseline design for thermal control of several spacecraft, including NASA's GLAS and Chemistry, ESA's ATLID, CNES' STENTOR, RKA's OBZOR, and several commercial satellites. Numerous LHP papers have been published since the mid-1980's. Most papers presented test results and discussions on certain specific aspects of the LHP operation. LHP's and CPL's show many similarities in their operating principles and performance characteristics. However, they also display significant differences in many aspects of their operation. Some of the LHP behaviors may seem strange or mysterious, even to experienced CPL practitioners. The main purpose of this paper is to present a systematic description of the operating principles and thermal-hydraulic behaviors of LHP'S. LHP operating principles will be given first, followed by a description of the thermal-hydraulics involved in LHP operation. Operating characteristics and important parameters affecting the LHP operation will then be described in detail. Peculiar behaviors of the LHP, including temperature hysteresis and temperature overshoot during start-up, will be explained. For simplicity, most discussions will focus upon LHP's with a single evaporator and a single condenser, but devices with multiple evaporators and condensers will also be discussed. Similarities and differences between LHP's and CPL's will be addressed throughout the paper whenever appropriate.

Ku, Jentung↗

Shallow and Deep Latent Heating Modes Over Tropical Oceans Observed with TRMM PR Spectral Latent Heating Data

The global hydrological cycle is central to the Earth's climate system, with rainfall and the physics of its formation acting as the key links in the cycle. Two-thirds of global rainfall occurs in the Tropics. Associated with this rainfall is a vast amount of heat, which is known as latent heat. It arises mainly due to the phase change of water vapor condensing into liquid droplets; three-fourths of the total heat energy available to the Earth's atmosphere comes from tropical rainfall. In addition, fresh water provided by tropical rainfall and its variability exerts a large impact upon the structure and motions of the upper ocean layer. Three-dimensional distributions of latent heating estimated from Tropical Rainfall Measuring Mission Precipitation Radar (TRMM PR)utilizing the Spectral Latent Heating (SLH) algorithm are analyzed. Mass-weighted and vertically integrated latent heating averaged over the tropical oceans is estimated as approx.72.6 J/s (approx.2.51 mm/day), and that over tropical land is approx.73.7 J/s (approx.2.55 mm/day), for 30degN-30degS. It is shown that non-drizzle precipitation over tropical and subtropical oceans consists of two dominant modes of rainfall systems, deep systems and congestus. A rough estimate of shallow mode contribution against the total heating is about 46.7 % for the average tropical oceans, which is substantially larger than 23.7 % over tropical land. While cumulus congestus heating linearly correlates with the SST, deep mode is dynamically bounded by large-scale subsidence. It is notable that substantial amount of rain, as large as 2.38 mm day-1 in average, is brought from congestus clouds under the large-scale subsiding circulation. It is also notable that even in the region with SST warmer than 28 oC, large-scale subsidence effectively suppresses the deep convection, remaining the heating by congestus clouds. Our results support that the entrainment of mid-to-lower-tropospheric dry air, which accompanies the large-scale subsidence is the major factor suppressing the deep convection. Therefore, representation of the realistic entrainment is very important for proper reproduction of precipitation distribution and resultant large-scale circulation.

Takayabu, Yukari N.↗

Theoretical Analysis of a Single-Stage Gas-fired Ejector Heat Pump Water Heater

Ejector-driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump (EHP) system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this study, a single-stage gas-fired EHP is investigated and thermodynamically modeled to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120–180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Our results show that an optimized COP for the EHP system exists and is dependent on HTE and LTE temperatures and the primary nozzle throat diameter. In addition, it is found that the peak EHP COP does not necessarily coincide with a large ejector COP. From this study, a maximum EHP COP of 1.31 is achieved at a HTE temperature of 170 °C and LTE temperature of 19.5 °C with a total heating capacity of 15.98 kW.

42 ENGINEERING↗

Thermal Control Utilizing an Thermal Control Utilizing an Two-Phase Loop with High Heat Flux Source

The electric field applied in dielectric fluids causes an imbalance in the dissociation-recombination reaction generated free space charges. The generated charges are redistributed by the applied electric field resulting in the heterocharge layers in the Vicinity of the electrodes. Proper design of the electrodes generates net axial flow motion pumping the fluid. The electrohydrodynamic (EHD) conduction pump is a new device that pumps dielectric fluids utilizing heterocharge layers formed by imposition of electrostatic fields. This paper evaluates the experimental performance of a two-phase breadboard thermal control loop consisting of an EHD conduction pump, condenser, pre-heater, high heat flux evaporator (HE), transport lines, and reservoir (accumulator). The generated pressure head and the maximum applicable heat flux are experimentally determined at various applied voltages and sink temperatures. Recovery from dryout condition by increasing the applied voltage to the pump is also demonstrated.

Jeong, Seong-Il↗

ResStock Measure Documentation: Residential Single-Stage Geothermal Heat Pump (3.8 COP, 18.6 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Single-Stage Geothermal Heat Pump (GHP).?Single-stage GHPs are able to reduce energy consumption by 31% for the entire stock. Additional results provided below detail how savings changes for sections of the housing stock with different base heating fuel and in different climate zones, as well as the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

Analysis of MHD stability and active mode control on KSTAR for high confinement, disruption-free plasma

Long-pulse plasma operation at high normalized beta, $β_N$, above the $\textit{n}$= 1 ideal MHD no-wall stability limit in KSTAR is presently limited by tearing instabilities rather than resistive wall modes. H-mode plasma operation during the recent KSTAR device campaign produced discharges having strong $\textit{m/n}$= 2/1 tearing instabilities at $β_N$ lower than the ideal MHD no-wall beta limit. The unstable tearing mode consequently reduced plasma confinement and toroidal plasma rotation significantly. We report the experiment confirmed that an extended duration of electron cyclotron heating (ECH) at the initial phase of the discharge plays a critical role in mode destabilization. To study destabilizing mechanisms that affect the mode growth, the stability of the observed tearing modes from plasmas with significantly different $β_N$ is computed by using the resistive DCON code and the M3D-C 1 code. Equilibrium reconstructions that include constraints from internal profile diagnostics, and computed fast particle pressure are used as input for reliable computation of stability. The classical tearing stability index, Δ', from resistive DCON is computed to be unstable when the island is fully saturated with large amplitude, while the unstable mode is not computed by M3D-C 1 . The modified Rutherford equation (MRE) describing the evolution of the island width has been constructed for KSTAR plasmas by using plasma parameters computed by the TRANSP code. The MRE model estimates a saturated island width corresponding to ~10% of the plasma minor radius for equilibrium at high $β_N$ 3 having a stable Δ' from the resistive DCON. In preparation for long-pulse plasma operation at higher beta utilizing increased plasma heating power, a resistive wall mode (RWM) active feedback control algorithm has been completed and enabled on KSTAR. To accurately determine the $\textit{n}$= 1component produced by RWMs, an algorithm has been developed that includes magnetic sensor compensation of the prompt applied field and the field from the induced current on the passive conductors. Use of multiple toroidal sensor arrays is enabled by modifying the sensor toroidal angles assumed in mode decomposition to include the effect of varied mode helicities in the outboard region where the mode measurement is made. This analysis on stability, transport, and control provides the required foundation for disruption prediction and avoidance research on KSTAR.

resistive wall mode (RWM)↗

Fiscalini Farms Biomass Energy Project

In this final report describes and documents research that was conducted by the Ecological Engineering Research Program (EERP) at the University of the Pacific (Stockton, CA) under subcontract to Fiscalini Farms LP for work under the Assistance Agreement DE-EE0001895 'Measurement and Evaluation of a Dairy Anaerobic Digestion/Power Generation System' from the United States Department of Energy, National Energy Technology Laboratory. Fiscalini Farms is operating a 710 kW biomass-energy power plant that uses bio-methane, generated from plant biomass, cheese whey, and cattle manure via mesophilic anaerobic digestion, to produce electricity using an internal combustion engine. The primary objectives of the project were to document baseline conditions for the anaerobic digester and the combined heat and power (CHP) system used for the dairy-based biomass-energy production. The baseline condition of the plant was evaluated in the context of regulatory and economic constraints. In this final report, the operation of the plant between start-up in 2009 and operation in 2010 are documented and an interpretation of the technical data is provided. An economic analysis of the biomass energy system was previously completed (Appendix A) and the results from that study are discussed briefly in this report. Results from the start-up and first year of operation indicate that mesophilic anaerobic digestion of agricultural biomass, combined with an internal combustion engine, is a reliable source of alternative electrical production. A major advantage of biomass energy facilities located on dairy farms appears to be their inherent stability and ability to produce a consistent, 24 hour supply of electricity. However, technical analysis indicated that the Fiscalini Farms system was operating below capacity and that economic sustainability would be improved by increasing loading of feedstocks to the digester. Additional operational modifications, such as increased utilization of waste heat and better documentation of potential of carbon credits, would also improve the economic outlook. Analysis of baseline operational conditions indicated that a reduction in methane emissions and other greenhouse gas savings resulted from implementation of the project. The project results indicate that using anaerobic digestion to produce bio-methane from agricultural biomass is a promising source of electricity, but that significant challenges need to be addressed before dairy-based biomass energy production can be fully integrated into an alternative energy economy. The biomass energy facility was found to be operating undercapacity. Economic analysis indicated a positive economic sustainability, even at the reduced power production levels demonstrated during the baseline period. However, increasing methane generation capacity (via the importation of biomass codigestate) will be critical for increasing electricity output and improving the long-term economic sustainability of the operation. Dairy-based biomass energy plants are operating under strict environmental regulations applicable to both power-production and confined animal facilities and novel approached are being applied to maintain minimal environmental impacts. The use of selective catalytic reduction (SCR) for nitrous oxide control and a biological hydrogen sulfide control system were tested at this facility. Results from this study suggest that biomass energy systems can be compliant with reasonable scientifically based air and water pollution control regulations. The most significant challenge for the development of biomass energy as a viable component of power production on a regional scale is likely to be the availability of energy-rich organic feedstocks. Additionally, there needs to be further development of regional expertise in digester and power plant operations. At the Fiscalini facility, power production was limited by the availability of biomass for methane generation, not the designed system capacity. During the baseline study period, feedstocks included manure, sudan grass silage, and refused-feed. The ability of the dairy to produce silage in excess of on-site feed requirements limited power production. The availability of biomass energy crops and alternative feedstocks, such as agricultural and food wastes, will be a major determinant to the economic and environmental sustainability of biomass based electricity production.

03 NATURAL GAS↗

Utilization of satellite-derived cloud cover to improve the estimation of latent heat release in a winter extratropical cyclone

A simple scheme for utilizing satellite cloud pattern information to improve the estimation of parameterized stable and convective latent heat release is proposed and tested for an extratropical cyclone occurring over the United States during January 9-11, 1975. Calculations are done over the standard North American rawinsonde data region and over a sparse data region simulated by ignoring one-third of the original rawinsonde stations. Results indicate 15 percent and 30 percent improvements in latent heating estimates derived from the total and sparse data sets, respectively. A larger improvement was found using the sparse data set because the parameterized latent heat release estimates obtained using these data were poorer than those obtained using the total data set.

Lin, S.-J.↗

Data Efficiency Assessment of Generative Adversarial Networks for Critical Heat Flux Synthetic Data Generation

This study investigates the application of generative artificial intelligence techniques, particularly conditional generative adversarial networks (cGAN), in real-world engineering contexts, with a specific focus on synthetic data generation for critical heat flux (CHF). Utilizing a dataset comprising more than 20,000 real experimental CHF measurements, we conduct a series of experiments to examine cGAN’s behavior. These experiments encompass varying sizes of the training dataset, training cGAN on data from diverse experimental sources to generate new data on unseen experimental setups, and assessing the impact of excluding various input features on cGAN’s data generation accuracy. Our findings underscore the pronounced data dependency of cGAN for reliable performance, with decreased efficacy observed with smaller training dataset sizes. Notably, cGAN exhibits varying performance when trained on data from different experiments, with superior predictive capabilities observed for certain experiment sources compared to others. For instance, when cGAN was trained on data from Smolin et al.’s experiments or Zenkevich et al., it exhibited relatively good performance in generating the data from Becker et al., Kirillov et al., and Alekseev et al. experiments. In contrast, when trained with Alekseev et al.’s data and tasked with generating other experimental setups, cGAN showed notably poor performance. In both scenarios, cGAN’s performance was inferior compared to training on samples from all experiments concurrently. A feature importance analysis highlights the significant influence of parameters such as mass flux and heated length on accurate CHF generation, while other parameters like diameter and pressure have less impact. Inlet temperature is identified as a moderating factor by cGAN.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Stabilizing the Grid and Reducing Utility Bills Through Price-Responsive Controls for Heat Pump Water Heaters

The electricity grid is facing increasing challenges in cost-effectively balancing supply and demand. These challenges are exacerbated by increased penetration of photovoltaics, which causes mid-day overproduction, and electrification of gas appliances, which increases peak-period electricity demand. Decarbonization requires shifting building loads from fossil-intensive high-cost times to renewable-intensive low-cost times while maintaining quality of service to occupants. Utilities and ISO’s are investigating new ways of incentivizing this load shifting. One promising method is the use of Highly Dynamic Prices (HDPs). HDPs feature continuously changing prices that reflect real-time grid generation and distribution costs and capacity constraints, and thus incentivize consumers to shift their loads. California’s CPUC CalFUSE proposal and Hawaii’s recent changes demonstrate that electricity tariffs are moving towards this model. For this to work however, loads must have the capability to respond to these prices. Heat pump water heaters (HPWHs) are an ideal device for this purpose because their storage tanks decouple delivery of domestic hot water from electricity consumption. The storage enables control strategies that consume midday solar power to increase the energy stored in the tank, then provide evening peak domestic hot water services using the stored energy. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls for many flexible loads - including HPWHs - in response to HDP. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of the on-board controller in a residential, integrated HPWH . The price-responsive controls a) shift load in ways that consume additional midday solar power to help stabilize the grid and reduce overall emissions, b) ensure that occupants receive equal or better hot water delivery service, and c) minimize the operating cost for each home in the fleet. On the grid level, the resulting shift will reduce utility operating costs and emissions, and can avoid expensive system capacity expansions. The control approach is customized to each home based on typical hot water consumption patterns. HPWH controllers, whether on the device or remotely, will receive a schedule of CTA-2045-B signals or set temperature adjustments customized to the current HDP price schedule and home. Simulation results for a fleet of 148 HPWHs on a summer day in Berkeley, California show cost savings of 29% and high price electricity consumption reductions of 80%, while maintaining full quality of service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Carbon-Nanotube-Carpet Heat-Transfer Pads

Microscopic thermal-contact pads that include carpet-like arrays of carbon nanotubes have been invented for dissipating heat generated in integrated circuits and similarly sized single electronic components. The need for these or other innovative thermal-contact pads arises because the requisite high thermal conductances cannot be realized by scaling conventional macroscopic thermal-contact pads down to microscopic sizes. Overcoming limitations of conventional thermal-contact materials and components, the carbon-nanotube thermal-contact pads offer the high thermal conductivities needed to accommodate the high local thermal power densities of modern electronic circuits, without need for large clamping pressures, extreme smoothness of surfaces in contact, or gap-filling materials (e.g., thermally conductive greases) to ensure adequate thermal contact. Moreover, unlike some conventional thermal-contact components, these pads are reusable. The figure depicts a typical pad according to the invention, in contact with a rough surface on an electronic component that is to be cooled. Through reversible bending and buckling of carbon nanotubes at asperities on the rough surface, the pad yields sufficiently, under relatively low contact pressure, that thermal contact is distributed to many locations on the surface to be cooled, including valleys where contact would not ordinarily occur in conventional clamping of rigid surfaces. Hence, the effective thermal-contact area is greater than that achievable through scaling down of a macroscopic thermal-contact pad. The extremely high longitudinal thermal conductivities of the carbon nanotubes are utilized to conduct heat away from potential hot spots on the surface to be cooled. The fibers protrude from a layer of a filler material (Cu, Ag, Au, or metal-particle- filled gels), which provides both mechanical support to maintain the carbon nanotubes in alignment and thermal conductivity to enhance the diffusion of concentrated heat from the nanotubes into the larger adjacent volume of a heat sink. The array of carbon nanotubes, the filler material, and the heat sink are parts of a unitary composite structure that is fabricated as follows: 1. Using techniques that have been reported previously, the array of substantially perpendicularly oriented carbon nanotubes is grown on a metal, silicon, or other suitable thermally conductive substrate that is intended to become the heat sink. 2. By means of chemical vapor deposition, physical vapor deposition, plasma deposition, ion sputtering, electrochemical deposition, or casting from a liquid phase, some or all of the interstitial volume between carbon nanotubes is filled with the aforementioned layer of mechanically supporting, thermally conductive material. 3. To cause the carbon nanotubes to protrude the desired length from the filler material, an outer layer of filler is removed by mechanical polishing, chemical mechanical polishing, wet chemical etching, electrochemical etching, or dry plasma etching.

Li, Jun↗

The Effect of Hydrothermal Alteration and Microcracks on Hydraulic Properties and Poroelastic Deformation: A Case Study of the Blue Mountain Geothermal Field

Abstract Geothermal energy plays a vital role in decarbonizing electricity and heat supply. Effective utilization of geothermal resources hinges on identifying or generating permeable reservoir zones and understanding how effective pressure variations affect fluid circulation and reservoir properties by poroelastic deformation. Hydrothermal alteration can modify the petrophysical properties of geothermal reservoir rocks, which may increase or decrease its productivity. Understanding these alteration effects is essential to predict and optimize long‐term sustainable geothermal operations. Here, we investigate the impact of hydrothermal alteration on poroelastic and hydraulic properties of diverse lithologies in a series of deformation tests performed at several confining (0–80 MPa) and pore pressure (10–30 MPa) levels. Experimental results of hydrothermally altered dikes and phyllites obtained from the Blue Mountain geothermal field (Nevada, USA) are compared to thermally cracked La Peyratte granite (France) and correlated with petrophysical properties, mineral composition, and microstructures. Argillic alteration of dikes increases porosity and storage capacity but lowers thermal conductivity and increases pore compressibility. Conversely, silicate precipitation in phyllites increases stiffness and thermal conductivity but also reduces porosity and permeability. Experimentally determined effective pressure coefficients range from 0.1 to 0.9, differ for permeability and volumetric strain and decrease with increasing effective pressure. The presence of compliant microcracks and crack‐like pores significantly increases the stress sensitivity of La Peyratte granite and silicified phyllites. This study demonstrates how thermal and chemical alteration impacts poromechanical and petrophysical characteristics of geothermal targets, which ultimately govern reservoir stability and subsidence, induced seismicity as well as fluid and heat extraction efficiency during geothermal operations.

Schuster, Valerian [Helmholtz Centre Potsdam GFZ G↗

An electrochemical system for efficiently harvesting low-grade heat energy

Capable and low-cost thermal energy-harvesting systems are necessary to utilize the tremendous low-grade heat sources. Although thermoelectric devices are attractive, its efficiency is limited by the relatively low figure-of-merit and low-temperature differential. An alternative method is to explore thermodynamic cycles. Thermogalvanic effect, the dependence of electrode potential on temperature, can construct such cycles. In one cycle, an electrochemical cell is charged at a temperature and then discharged at a different temperature with higher cell voltage, thereby converting heat to electricity. Here we report an electrochemical system using a copper hexacyanoferrate cathode and a Cu/Cu 2+ anode to convert heat into electricity. The electrode materials have low polarization, high charge capacity, moderate temperature coefficients and low specific heat. These features lead to a high heat-to-electricity energy conversion efficiency of 5.7% when cycled between 10 and 60 °C, opening a promising way to utilize low-grade heat.

25 ENERGY STORAGE↗