Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture

PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Particle Imaging Guided Real-Time Percutaneous Transluminal Angioplasty in a Phantom Model

PurposeTo investigate the potential of real-time magnetic particle imaging (MPI) to guide percutaneous transluminal angioplasty (PTA) of vascular stenoses in a phantom model.Materials and MethodsExperiments were conducted on a custom-built MPI scanner. Vascular stenosis phantoms consisted of polyvinyl chloride tubes (inner diameter 8 mm) prepared with a centrally aligned cable tie to form ~ 50% stenoses. MPI angiography for visualization of stenoses was performed using the superparamagnetic iron oxide nanoparticle-based contrast agent Ferucarbotran (10 mmol (Fe)/l). Balloon catheters and guidewires for PTA were visualized using custom-made lacquer markers based on Ferucarbotran. Stenosis dilation (n = 3) was performed by manually inflating the PTA balloon with diluted Ferucarbotran. An online reconstruction framework was implemented for real-time imaging with very short latency time.ResultsVisualization of stenosis phantoms and guidance of interventional instruments in real-time (4 frames/s, ~ 100 ms latency time) was possible using an online reconstruction algorithm. Labeling of guidewires and balloon catheters allowed for precise visualization of instrument positions.ConclusionReal-time MPI-guided PTA in a phantom model is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ice Ball Crack During CT-Guided Renal Cryoablation Using 1.5-mm-Diameter Cryoprobes

Ice ball fracture and massive hemorrhage are serious complications associated with renal cryoablation. When cracks occur in an ice ball, it is usually associated with adjacent renal parenchymal fracture, leading to massive hemorrhage. However, few studies have examined ice ball fracture under image-guided percutaneous renal cryoablation. We herein describe an 80-year-old male patient who had undergone CT-guided cryoablation for a left renal tumor using four cryoprobes (1.5 mm diameter each). Ice ball cracks were observed on CT images during cryoablation. However, there was no massive hemorrhage and further treatments were not necessary. This is the first report of ice ball cracks with a smaller diameter cryoprobe, which has not been considered to be associated with ice ball fracture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Percutaneous Bleomycin and Bevacizumab Sclerotherapy of Orbital Lymphatic Malformations in Children

Purpose: To evaluate the effectiveness and safety of image-guided percutaneous sclerotherapy using bleomycin for macrocystic and bevacizumab (Avastin™) for microcystic orbital lymphatic malformations in children. Materials and Methods: Between October 2015 and July 2018, we prospectively evaluated 10 pediatric patients who presented clinically and radiologically with lymphatic malformations and were treated with percutaneous sclerotherapy. Patients with venous malformations were excluded. Eight females and two males with ages ranging from 3 to 17 years (mean: 8.8, SD: 4.9) were included. Guided with ultrasound and fluoroscopy, macrocysts were treated with bleomycin instillation. For microcystic components in three patients, bevacizumab was injected intralesional. All patients underwent ultrasound and non-contrast MRI to evaluate response to treatment after 6 weeks. Results: The malformations were macrocystic in seven patients and complex (macro/microcystic) in three. Twenty sclerotherapy sessions were performed, (range: 1–3 sessions, mean: 2, SD: 0.8). Clinically, there was a significant reduction in the proptosis after treatment (P = 0.007) and dystopia (P = 0.018). The local radiological response showed a reduction in the maximum lesions diameters and volumes after treatment (P = 0.005 and 0.005, respectively). Two of the three patients treated with bevacizumab showed a reduction in the lesions volumes by 90.4% and 63.4%, respectively, whereas one patient did not show volume reduction. Transient periorbital edema and ecchymosis occurred following the procedure with no major complications encountered. Follow-up ranged from 9–33 months, mean: 20.3, SD: 7.4. Conclusion: Bleomycin sclerotherapy is a safe and effective treatment for orbital macrocystic lymphatic malformations. Further use of bevacizumab for microcystic lesions in a larger series is required to outline its efficacy and safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and validation of an automatic method to detect the latest contracting viable left ventricular segments to assist guide CRT therapy from gated SPECT myocardial perfusion imaging

Objectives: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. Methods: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. Results: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. Conclusions: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of Ultrasound-Guided Injections for Tendinopathies

Purpose of Review: The purpose of the study was to review the efficacy and safety of common ultrasound-guided injections for tendinopathy conditions. Corticosteroid injections have historically been the most common injection used for tendinopathy; however, there are an increasing number of injections including platelet-rich plasma, hyaluronan, polidocanol, botulinum toxin, and high volume saline injections. Recent Findings: There is growing evidence that while corticosteroid injections for tendinopathies usually have short-term efficacy, they may result in medium-term harm, particularly for tennis elbow (lateral epicondylitis). Corticosteroid injections appear to have more clinical utility for tenosynovitis conditions. There is insufficient evidence regarding other injection options to make a broad recommendation in favour, although individual trials for certain tendons illustrate benefits for some of the non-corticosteroid options. Summary: When considering the use of ultrasound-guided corticosteroid injections for tendinopathies, the risk of possible medium-term harm must be weighed up against any short-term efficacy. Other injection-based therapies may be appropriate in certain clinical situations; however, the evidence and clinical circumstances must be considered for the particular tendon and patient. Load-based rehabilitation remains the cornerstone of tendinopathy management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase transformation dynamics guided alloy development for additive manufacturing

Fusion-based additive manufacturing technologies enable the fabrication of geometrically and compositionally complex parts unachievable by conventional manufacturing methods. However, the non-uniform and far-from-equilibrium heating/cooling conditions pose a significant challenge to consistently obtaining desirable phases in the as-printed parts. Here, in this study, we report a martensite stainless steel development guided by phase transformation dynamics revealed by in-situ high-speed, high-energy, high-resolution X-ray diffraction. This developed stainless steel consistently forms desired fully martensitic structure across a wide range of cooling rates (10 2 –10 7 °C/s), which enables direct printing of parts with fully martensitic structure. The as-printed material exhibits a yield strength of 1157 ± 23 MPa, comparable to its wrought counterpart after precipitation-hardening heat-treatment. The as-printed property is attributed to the fully martensitic structure and the fine precipitates formed during the intrinsic heat treatment in additive manufacturing. The phase transformation dynamics guided alloy development strategy demonstrated here opens the path for developing reliable, high-performance alloys specific for additive manufacturing.

17–4 PH stainless steel↗

From liquid crystal models to the guiding-center theory of magnetized plasmas

Upon combining Northrop’s picture of charged particle motion with modern liquid crystal theories, this paper provides a new description of guiding center dynamics (to lowest order). This new perspective is based on a rotation gauge field (gyrogauge) that encodes rotations around the magnetic field. In liquid crystal theory, an analogue rotation field is used to encode the rotational state of rod-like molecules. Instead of resorting to sophisticated tools (e.g. Hamiltonian perturbation theory and Lie series expansions) that still remain essential in higher-order gyrokinetics, the present approach combines the WKB method with a simple kinematical ansatz, which is then replaced into the charged particle Lagrangian. The latter is eventually averaged over the gyrophase to produce the guiding-center equations. A crucial role is played by the vector potential for the gyrogauge field. A similar vector potential is related to liquid crystal defects and is known as wryness tensor in Eringen’s micropolar theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure-Guided Development of a Potent and Selective Non-covalent Active-Site Inhibitor of USP7

Deubiquitinating enzymes (DUBs) have garnered significant attention as drug targets in the last 5–10 years. The excitement stems in large part from the powerful ability of DUB inhibitors to promote degradation of oncogenic proteins, especially proteins that are challenging to directly target but which are stabilized by DUB family members. Highly optimized and well-characterized DUB inhibitors have thus become highly sought after tools. Most reported DUB inhibitors, however, are polypharmacological agents possessing weak (micromolar) potency toward their primary target, limiting their utility in target validation and mechanism studies. Due to a lack of high-resolution DUB∙small-molecule ligand complex structures, no structure-guided optimization efforts have been reported for a mammalian DUB. In this paper, we report a small-molecule∙ubiquitin-specific protease (USP) family DUB co-structure and rapid design of potent and selective inhibitors of USP7 guided by the structure. Interestingly, the compounds are non-covalent active-site inhibitors.

59 BASIC BIOLOGICAL SCIENCES↗

Rats use memory confidence to guide decisions

Memory enables access to past experiences to guide future behavior. Humans can determine which memories to trust (high confidence) and which to doubt (low confidence). How memory retrieval, memory confidence, and memory-guided decisions are related, however, is not understood. In particular, how confidence in memories is used in decision making is unknown. We developed a spatial memory task in which rats were incentivized to gamble their time: betting more following a correct choice yielded greater reward. Rat behavior reflected memory confidence, with higher temporal bets following correct choices. We applied machine learning to identify a memory decision variable and built a generative model of memories evolving over time that accurately predicted both choices and confidence reports. Our results reveal in rats an ability thought to exist exclusively in primates and introduce a unified model of memory dynamics, retrieval, choice, and confidence.

60 APPLIED LIFE SCIENCES↗

Predicting lake surface water phosphorus dynamics using process-guided machine learning

Phosphorus (P) loading to lakes is degrading the quality and usability of water globally. Accurate predictions of lake P dynamics are needed to understand whole-ecosystem P budgets, as well as the consequences of changing lake P concentrations for water quality. However, complex biophysical processes within lakes, along with limited observational data, challenge our capacity to reproduce short-term lake dynamics needed for water quality predictions, as well as long-term dynamics needed to understand broad scale controls over lake P. Here we use an emerging paradigm in modeling, process-guided machine learning (PGML), to produce a phosphorus budget for Lake Mendota (Wisconsin, USA) and to accurately predict epilimnetic phosphorus over a time range of days to decades. In our implementation of PGML, which we term a Process-Guided Recurrent Neural Network (PGRNN), we combine a process-based model for lake P with a recurrent neural network, and then constrain the predictions with ecological principles. We test independently the process-based model, the recurrent neural network, and the PGRNN to evaluate the overall approach. The process-based model accounted for most of the observed pattern in lake P; however it missed the long-term trend in lake P and had the worst performance in predicting winter and summer P in surface waters. The root mean square error (RMSE) for the process-based model, the recurrent neural network, and the PGRNN was 33.0 μg P L -1 , 22.7 μg P L -1 , and 20.7 μg P L -1 , respectively. All models performed better during summer, with RMSE values for the three models (same order) equal to 14.3 μg P L -1 , 10.9 μg P L -1 , and 10.7 μg P L -1 . Although the PGRNN had only marginally better RMSE during summer, it had lower bias and reproduced long-term decreases in lake P missed by the other two models. For all seasons and all years, the recurrent neural network had better predictions than process alone, with root mean square error (RMSE) of 23.8 μg P L -1 and 28.0 μg P L -1 , respectively. The output of PGRNN indicated that new processes related to water temperature, thermal stratification, and long term changes in external loads are needed to improve the process model. By using ecological knowledge, as well as the information content of complex data, PGML shows promise as a technique for accurate prediction in messy, real-world ecological dynamics, while providing valuable information that can improve our understanding of process.

54 ENVIRONMENTAL SCIENCES↗

Computation-guided discovery of coating materials to stabilize the interface between lithium garnet solid electrolyte and high-energy cathodes for all-solid-state lithium batteries

All-solid-state batteries with a lithium metal anode, enabled by lithium garnet solid electrolytes such as Li 7 La 3 Zr 2 O 12 (LLZO), are a promising next-generation energy-storage technology. The further development of all-solid-state battery requires the integration of high-energy cathodes such as LiNi 1-x-y Mn x Co y O 2 (NMC) with the garnet solid electrolyte with stable and low-resistance interfaces, which requires a coating layer to stabilize the interface during high-temperature sintering and electrochemical cycling. In order to guide the future development of interfacial coatings, we perform high-throughput thermodynamic analyses based on first-principles computation to investigate the stability of LLZO garnet and high-energy NMC cathodes with a wide range of materials chemistries. Here our study reveals the factors governing the materials stability with LLZO garnet and NMC cathodes, and identifies the mechanisms of good coating layers stable with LLZO and NMC. In addition to classifying known coating layers, our study provides detailed guiding charts and multiple new materials systems as promising coatings for stabilizing LLZO—NMC interfaces to enable high-energy-density garnet-based all-solid-state batteries. Our demonstrated computation scheme and high-throughput analyses are generally applicable to investigate and screen coating materials for stabilizing interfaces in energy-related applications.

25 ENERGY STORAGE↗

Fluorine-18-Labeled Fluoromisonidazole Positron Emission and Computed Tomography-Guided Intensity-Modulated Radiotherapy for Head and Neck Cancer: A Feasibility Study

Purpose: Hypoxia renders tumor cells radioresistant, limiting locoregional control from radiotherapy (RT). Intensity-modulated RT (IMRT) allows for targeting of the gross tumor volume (GTV) and can potentially deliver a greater dose to hypoxic subvolumes (GTV{sub h}) while sparing normal tissues. A Monte Carlo model has shown that boosting the GTV{sub h} increases the tumor control probability. This study examined the feasibility of fluorine-18-labeled fluoromisonidazole positron emission tomography/computed tomography ({sup 18}F-FMISO PET/CT)-guided IMRT with the goal of maximally escalating the dose to radioresistant hypoxic zones in a cohort of head and neck cancer (HNC) patients. Methods and Materials: {sup 18}F-FMISO was administered intravenously for PET imaging. The CT simulation, fluorodeoxyglucose PET/CT, and {sup 18}F-FMISO PET/CT scans were co-registered using the same immobilization methods. The tumor boundaries were defined by clinical examination and available imaging studies, including fluorodeoxyglucose PET/CT. Regions of elevated {sup 18}F-FMISO uptake within the fluorodeoxyglucose PET/CT GTV were targeted for an IMRT boost. Additional targets and/or normal structures were contoured or transferred to treatment planning to generate {sup 18}F-FMISO PET/CT-guided IMRT plans. Results: The heterogeneous distribution of {sup 18}F-FMISO within the GTV demonstrated variable levels of hypoxia within the tumor. Plans directed at performing {sup 18}F-FMISO PET/CT-guided IMRT for 10 HNC patients achieved 84 Gy to the GTV{sub h} and 70 Gy to the GTV, without exceeding the normal tissue tolerance. We also attempted to deliver 105 Gy to the GTV{sub h} for 2 patients and were successful in 1, with normal tissue sparing. Conclusion: It was feasible to dose escalate the GTV{sub h} to 84 Gy in all 10 patients and in 1 patient to 105 Gy without exceeding the normal tissue tolerance. This information has provided important data for subsequent hypoxia-guided IMRT trials with the goal of further improving locoregional control in HNC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Current Brachytherapy Quality Assurance Guidance: Does It Meet the Challenges of Emerging Image-Guided Technologies?

In the past decade, brachytherapy has shifted from the traditional surgical paradigm to more modern three-dimensional image-based planning and delivery approaches. The role of intraoperative and multimodality image-based planning is growing. Published American Association of Physicists in Medicine, American College of Radiology, European Society for Therapeutic Radiology and Oncology, and International Atomic Energy Agency quality assurance (QA) guidelines largely emphasize the QA of planning and delivery devices rather than processes. These protocols have been designed to verify compliance with major performance specifications and are not risk based. With some exceptions, complete and clinically practical guidance exists for sources, QA instrumentation, non-image-based planning systems, applicators, remote afterloading systems, dosimetry, and calibration. Updated guidance is needed for intraoperative imaging systems and image-based planning systems. For non-image-based brachytherapy, the American Association of Physicists in Medicine Task Group reports 56 and 59 provide reasonable guidance on procedure-specific process flow and QA. However, improved guidance is needed even for established procedures such as ultrasound-guided prostate implants. Adaptive replanning in brachytherapy faces unsolved problems similar to that of image-guided adaptive external beam radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance Issues for Computed Tomography-, Ultrasound-, and Magnetic Resonance Imaging-Guided Brachytherapy

The requirements of quality assurance (QA) for both brachytherapy and imaging devices are well-defined, but image-guided brachytherapy has raised new issues. Image guidance in brachytherapy involves the transition from reference point dosimetry using films to volumetric imaging such as computed tomography, ultrasonography, and magnetic resonance imaging for treatment planning and guidance of applicator, needle, or seed placement. The QA of these devices might not reflect the conditions of use in brachytherapy or the requirements of brachytherapy treatment planning. Image interpretation becomes much more important with image-guided brachytherapy. The success of a procedure could depend on the interpretation of a single image in a calibration phase done under the time pressures of the operative setting. This change has implications at the level of treatment, the process, and the field of brachytherapy as a whole. The QA concerns arising from brachytherapy procedures using ultrasound, computed tomography, and magnetic resonance imaging guidance are discussed, as are the problems associated with using imaging in an interventional setting. This report was intended to indicate the QA concerns arising from the convergence of brachytherapy and imaging-highlighting areas in which technical improvements are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-Guided 3D Optimization Significantly Improves DVH Parameters of Pulsed-Dose-Rate Brachytherapy in Locally Advanced Cervical Cancer

Purpose: To compare dose-volume histogram parameters of standard Point A and magnetic resonance imaging-based three-dimensional optimized dose plans in 21 consecutive patients who underwent pulsed-dose-rate brachytherapy (PDR-BT) for locally advanced cervical cancer. Methods and Materials: All patients received external beam radiotherapy (elective target dose, 45 Gy in 25-30 fractions; tumor target dose, 50-60 Gy in 25-30 fractions). PDR-BT was applied with a tandem-ring applicator. Additional ring-guided titanium needles were used in 4 patients and a multichannel vaginal cylinder in 2 patients. Dose planning was done using 1.5 Tesla T{sub 1}-weighted and T{sub 2}-weighted paratransversal magnetic resonance imaging scans. T{sub 1}-weighted visible oil-containing tubes were used for applicator reconstruction. The prescribed standard dose for PDR-BT was 10 Gy (1 Gy/pulse, 1 pulse/h) for two to three fractions to reach a physical dose of 80 Gy to Point A. The total dose (external beam radiotherapy plus brachytherapy) was normalized to an equivalent dose in 2-Gy fractions using {alpha}/{beta} = 10 Gy for tumor, {alpha}/{beta} = 3 Gy for normal tissue, and a repair half-time of 1.5 h. The goal of optimization was dose received by 90% of the target volume (D{sub 90}) of {>=}85 Gy{sub {alpha}}{sub /{beta}}{sub 10} in the high-risk clinical target volume (cervix and remaining tumor at brachytherapy), but keeping the minimal dose to 2 cm{sup 3} of the bladder and rectum/sigmoid at <90 and <75 Gy{sub {alpha}}{sub /{beta}}{sub 3}, respectively. Results: Using three-dimensional optimization, all dose-volume histogram constraints were met in 16 of 21 patients compared with 3 of 21 patients with two-dimensional library plans (p < 0.001). Optimization increased the minimal target dose (D{sub 100}) of the high-risk clinical target volume (p < 0.007) and decreased the minimal dose to 2 cm{sup 3} for the sigmoid significantly (p = 0.03). For the high-risk clinical target volume, D{sub 90} was 91 {+-} 8 Gy{sub {alpha}}{sub /{beta}}{sub 10} and D{sub 100} was 76 {+-} 5 Gy{sub {alpha}}{sub /{beta}}{sub 10}. The minimal dose to 2 cm{sup 3} for the bladder, rectum, and sigmoid was 73 {+-} 6, 67 {+-} 6, and 69 {+-} 6 Gy{sub {alpha}}{sub /{beta}}{sub 3}, respectively. Conclusion: The results of our study have shown that magnetic resonance imaging-guided optimization of PDR-BT for locally advanced cervical cancer significantly improved the dose-volume histogram parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Clinical Trial of Positron Emission Tomography/Computed Tomography Image-Guided Intensity-Modulated Radiation Therapy for Cervical Carcinoma With Positive Para-Aortic Lymph Nodes

Purpose: To describe a more aggressive treatment technique allowing dose escalation to positive para-aortic lymph nodes (PALN) in patients with cervical cancer, by means of positron emission tomography (PET)/computed tomography (CT)-guided intensity-modulated radiation therapy (IMRT). Here, we describe methods for simulation and planning of these treatments and provide objectives for target coverage as well as normal tissue sparing to guide treatment plan evaluation. Methods and Materials: Patients underwent simulation on a PET/CT scanner. Treatment plans were generated to deliver 60.0 Gy to the PET-positive PALN and 50.0 Gy to the PALN and pelvic lymph node beds. Treatment plans were optimized to deliver at least 95% of the prescribed doses to at least 95% of each target volume. Dose-volume histograms were calculated for normal structures. Results: The plans of 10 patients were reviewed. Target coverage goals were satisfied in all plans. Analysis of dose-volume histograms indicated that treatment plans involved irradiation of approximately 50% of the bowel volume to at least 25.0 Gy, with less than 10% receiving at least 50.0 Gy and less than 1% receiving at least 60.0. With regard to kidney sparing, approximately 50% of the kidney volume received at least 16.0 Gy, less than 5% received at least 50.0 Gy, and less than 1% received at least 60.0 Gy. Conclusions: We have provided treatment simulation and planning methods as well as guidelines for the evaluation of target coverage and normal tissue sparing that should facilitate the more aggressive treatment of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Effect of Translational and Rotational Errors for Patients Undergoing Image-Guided Stereotactic Body Radiotherapy for Spinal Metastases

Purpose: To investigate the dosimetric effects of translational and rotational patient positioning errors on the treatment of spinal and paraspinal metastases using computed tomography image-guided stereotactic body radiotherapy. The results of this study provide guidance for the treatment planning process and recognition of the dosimetric consequences of daily patient treatment setup errors. Methods and Materials: The data from 20 patients treated for metastatic spinal cancer using image-guided stereotactic body radiotherapy were investigated in this study. To simulate the dosimetric effects of residual setup uncertainties, 36 additional plans (total, 756 plans) were generated for each isocenter (total, 21 isocenters) on the planning computed tomography images, which included isocenter lateral, anteroposterior, superoinferior shifts, and patient roll, yaw, and pitch rotations. Tumor volume coverage and the maximal dose to the organs at risk were compared with those of the original plan. Six daily treatments were also investigated to determine the dosimetric effect with or without the translational and rotational corrections. Results: A 2-mm error in translational patient positioning error in any direction can result in >5% tumor coverage loss and >25% maximal dose increase to the organs at risk. Rotational correction is very important for patients with multiple targets and for the setup of paraspinal patients when the isocenter is away from bony structures. Compared with the original plans, the daily treatment data indicated that translational adjustments could correct most of the setup errors to mean divergences of -1.4% for tumor volume coverage and -0.3% for the maximal dose to the organs at risk. Conclusion: For the best dosimetric results, spinal stereotactic treatments should have setup translational errors of {<=}1 mm and rotational errors of {<=}2 deg.

62 RADIOLOGY AND NUCLEAR MEDICINE↗