Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Impact of electric vehicles on the IEEE 34 node distribution infrastructure

With the growing penetration of the electric vehicles to our daily life owing to their economic and environmental benefits, there will be both opportunities and challenges to the utilities when adopting plug-in electric vehicles (PEV) to the distribution network. In this study, a thorough analysis based on real-world project is conducted to evaluate the impacts of electric vehicles infrastructure on the grid relating to system load flow, load factor, and voltage stability. IEEE 34 node test feeder was selected and tested along with different case scenarios utilizing the electrical distribution design (EDD) software to find out the potential impacts to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability Assessment of a System Comprising a Single Machine and a Virtual Oscillator Controlled Inverter with Scalable Ratings

We present a small-signal stability study of a coupled synchronous generator and inverter system, where the inverter is controlled by virtual oscillator control (VOC). VOC is a recently proposed grid-forming inverter control strategy, which acts on faster time scales compared to droop control. In our study, we leverage a scalable VOC controller (that is by design agnostic of power levels) to test the system's small-signal stability at different inverter penetration levels. The impact of rotational inertia, reactive power support, and filter parameters on stability is then investigated. Results highlight possible issues that might arise in these mixed machine-inverter systems further motivating the need to develop next generation stabilizing grid-forming controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FUN3D Analyses in Support of the 1st AIAA Stability and Control Prediction Workshop

The 1st AIAA Stability and Control Prediction Workshop was created to establish best practices for the prediction of stability & control derivatives using computational fluid dynamics and assess the limitations of these computational methods when those best practices are applied. The inaugural workshop considers the ONERA version of the NASA/Boeing Common Research Model(CRM), which includes the wing, body, horizontal tail, and a vertical tail designed by ONERA. Wind tunnel tests have been conducted for this configuration with longitudinal tests having been previously published, in addition to unpublished data at small sideslip angles that will serve as ‘blind’ data for workshop data comparisons. Participants were provided a ‘family’ of unstructured grids for the full-span ONERA CRM model with the wind-tunnel sting included. This family of mixed-element grids consists of 5 levels of refinement (tiny, coarse, medium, fine, and extra fine) with surface and volume mesh scaling, resulting in a size range of 14.6 to 53.4 million nodes. In addition, a medium refinement mesh has been provided for the ONERA CRM configuration without a sting to evaluate the sting’s impact on static longitudinal stability characteristics. In addition to these workshop-provided grids, the present work also considers an equivalent ‘family’ of computational grids generated using Heldenmesh™, a rapid grid generation software by Helden Aerospace Corporation for creating high-quality, three-dimensional, mixed-element unstructured meshes. Because of the authors’ familiarity with this software, these additional grids were generated as a comparison to the workshop-provided grids and to better understand the implications of using volume-mirrored grids for stability and control predictions. The present work will contribute to the workshop with test case data generated using the NASA FUN3D code, a parallelized, unstructured, node-based, finite-volume discretization, Reynolds-averaged Navier-Stokes flow solver. Numerical simulations will be conducted using the Quadratic Constitutive Relationship (QCR) version of the Spalart-Allmaras (SA) turbulence model with negative turbulence variable provisions. Both steady and2nd-order, time-accurate simulation results are to be generated and compared for select test cases, as time permits, to investigate their impact on FUN3D predictions. The present work will consider the three primary workshop test cases: (1) grid convergence study, (2) Mach number effect on static stability, and (3) wind tunnel sting increments. Additionally, data will be provided for the two optional test cases, which include:(1) static stability derivative calculations and (2)sideslip angle sweeps. In each of the test cases, the vehicle is stationary, and the body is assumed to be rigid, where vehicle deformation has been accounted for in the model configuration geometry. For all test cases, longitudinal and lateral force and moment aerodynamic coefficients will be provided for the total configuration, in addition to a component-level breakdown that includes the port wing, starboard wing, fuselage, and tail.

CFD↗

Adaptive Extremum Seeking Control Based LCL Filter Resonant Frequency Online Estimation

The LCL filter has been widely used in the grid-tied inverter systems. However, the resonance of the LCL filter can reduce the system stability margin and the control performance. Moreover, the grid impedance variations can lead to the drift of the resonant frequency, which can further worsen the system robustness. Thus, it is important to know the actual resonant frequency of the LCL filter. In this letter, an adaptive extremum seeking control (AESC) based estimation scheme is proposed to estimate the resonant frequency of the LCL filter online. Further by injecting a high-frequency (HF) signal into the inverter output voltage, the AESC scheme can identify the extremum of the LCL filter amplitude response, i.e., resonant peak. The amplitude of injection signal is adaptive based on the inverter HF response, which can address the tradeoff between the dynamic response and inverter output current quality. Most importantly, compare to other method, the proposed scheme has very low computational complexity, which minimizes the burden to the normal inverter controller operation. Stability analysis is given in this letter, and experimental studies are conducted to validate the effectiveness of the proposed scheme.

42 ENGINEERING↗

Adaptive Hierarchical Voltage Control of a DFIG-Based Wind Power Plant for a Grid Fault

This paper proposes an adaptive hierarchical voltage control scheme of a doubly-fed induction generator (DFIG)-based wind power plant (WPP) that can secure more reserve of reactive power (Q) in the WPP against a grid fault. To achieve this, each DFIG controller employs an adaptive reactive power to voltage (Q-V) characteristic. The proposed adaptive Q-V characteristic is temporally modified depending on the available Q capability of a DFIG; it is dependent on the distance from a DFIG to the point of common coupling (PCC). The proposed characteristic secures more Q reserve in the WPP than the fixed one. Furthermore, it allows DFIGs to promptly inject up to the Q limit, thereby improving the PCC voltage support. To avert an overvoltage after the fault clearance, washout filters are implemented in the WPP and DFIG controllers; they can prevent a surplus Q injection after the fault clearance by eliminating the accumulated values in the proportional-integral controllers of both controllers during the fault. Test results demonstrate that the scheme can improve the voltage support capability during the fault and suppress transient overvoltage after the fault clearance under scenarios of various system and fault conditions; therefore, it helps ensure grid resilience by supporting the voltage stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

25 ENERGY STORAGE↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

25 ENERGY STORAGE↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seismic Tomographic Modeling of the Crust and Upper Mantle beneath Israel and the Middle East: Improved Resolution through Optimized Model Parameterization

Accurate regional seismic travel-time (RSTT) predictions rely on regional phases (e.g., Pg, Lg, Pn, Sn ) to account for 3D effects in the crust and upper mantle that are not captured by 1D models traditionally used for real-time location. The RSTT prediction model accounts for regional-scale crust and upper mantle structure globally by incorporating regional seismic phases into its travel-time calculations. Previous versions of the RSTT model have used a constant grid cell size of 1°. To improve the tomographic accuracy of recovering velocity structure at regional scales, we, in this study, perform data-driven grid refinement on the RSTT model down to a 0.125° grid (~14 km) in pursuit of two main goals: (1) to test the limits of RSTT capability and accuracy of determined velocity structure through variable grid refinement and (2) to image smaller structures in Israel and the Middle East and illuminate upper mantle dynamics operating in this complex tectonic area. We investigate the effects of model parameterization as grid cell size decreases and the trade-offs between recovered velocity structures. Our final dataset includes 4751 events and 499 stations that recorded 79,344 Pn and 7489 Pg . The variable grid refinement method allows recovery of finer-scale velocity structures and reduces travel-time residuals in areas with the highest data coverage. At smaller grid cell sizes, longer paths need to be upweighted to stabilize the inversion. Results illuminate tectonic features undefined in coarser grid-size models; in particular, we observe mantle perturbations related to the subduction zone around the Cyprian arc and crustal anomalies near the Dead Sea fault and throughout the Anatolian plate.

58 GEOSCIENCES↗

A Novel Architecture for Attack-Resilient Wide-Area Protection and Control System in Smart Grid

Wide-area protection and control (WAPAC) systems are widely applied in the energy management system (EMS) that rely on a wide-area communication network to maintain system stability, security, and reliability. As technology and grid infrastructure evolve to develop more advanced WAPAC applications, however, so do the attack surfaces in the grid infrastructure. This paper presents an attack-resilient system (ARS) for the WAPAC cybersecurity by seamlessly integrating the network intrusion detection system (NIDS) with intrusion mitigation and prevention system (IMPS). In particular, the proposed NIDS utilizes signature and behavior-based rules to detect attack reconnaissance, communication failure, and data integrity attacks. Further, the proposed IMPS applies state transition-based mitigation and prevention strategies to quickly restore the normal grid operation after cyberattacks. As a proof of concept, we validate the proposed generic architecture of ARS by performing experimental case study for wide-area protection scheme (WAPS), one of the critical WAPAC applications, and evaluate the proposed NIDS and IMPS components of ARS in a cyber-physical testbed environment. Our experimental results reveal a promising performance in detecting and mitigating different classes of cyberattacks while supporting an alert visualization dashboard to provide an accurate situational awareness in real-time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?: Preprint

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converterinterfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. An interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a variedlength transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

14 SOLAR ENERGY↗

Validation of turbulence intensity as simulated by the Weather Research and Forecasting model off the US northeast coast

We report turbulence intensity (TI) is often used to quantify the strength of turbulence in wind energy applications and serves as the basis of standards in wind turbine design. Thus, accurately characterizing the spatiotemporal variability in TI should lead to improved predictions of power production. Nevertheless, turbulence measurements over the ocean are far less prevalent than over land due to challenges in instrumental deployment, maintenance, and operation. Atmospheric models such as mesoscale (weather prediction) and large-eddy simulation (LES) models are commonly used in the wind energy industry to assess the spatial variability of a given site. However, the TI derivation from atmospheric models has not been well examined. An algorithm is proposed in this study to realize online calculation of TI in the Weather Research and Forecasting (WRF) model. Simulated TI is divided into two components depending on scale, including sub-grid (parameterized based on turbulence kinetic energy (TKE)) and grid resolved. The sensitivity of sea surface temperature (SST) on simulated TI is also tested. An assessment is performed by using observations collected during a field campaign conducted from February to June 2020 near the Woods Hole Oceanographic Institution Martha's Vineyard Coastal Observatory. Results show that while simulated TKE is generally smaller than the lidar-observed value, wind speed bias is usually small. Overall, this leads to a slight underestimation in sub-grid-scale estimated TI. Improved SST representation subsequently reduces model biases in atmospheric stability as well as wind speed and sub-grid TI near the hub height. Large TI events in conjunction with mesoscale weather systems observed during the studied period pose a challenge to accurately estimating TI from models. Due to notable uncertainty in accurately simulating those events, this suggests summing up sub-grid and resolved TI may not be an ideal solution. Efforts in further improving skills in simulating mesoscale flow and cloud systems are necessary as the next steps.

17 WIND ENERGY↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

Study the Protection Improvements for a Weak Grid Area With High IBRs

NLR is collaborating with Florida Power & Light (FPL) and GE to investigate power system stability and protection reliability challenges in a weak-grid region with high penetration of inverter-based resources (IBRs). This presentation will primarily focus on the protection aspects of the study. We will share key insights from this real-world project, including best practices for developing high-fidelity fault study models, establishing a controller-hardware-in-the-loop (CHIL) platform for testing physical relays, identifying system-level protection challenges, and designing enhanced protection schemes to address those issues. Through this discussion, the audience will gain practical understanding of protection studies in IBR-dominated systems, the emerging challenges associated with reduced fault current and altered transient behavior, and effective mitigation strategies. In particular, we will highlight the critical importance of IBR compliance with IEEE 2800-2022 to ensure dependable and secure protection relay operation in modern transmission systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comparison of Grid-based and SPH Binary Mass-transfer and Merger Simulations

There is currently a great amount of interest in the outcomes and astrophysical implications of mergers of double degenerate binaries. In a commonly adopted approximation, the components of such binaries are represented by polytropes with an index of n = 3/2. We present detailed comparisons of stellar mass-transfer and merger simulations of polytropic binaries that have been carried out using two very different numerical algorithms—a finite-volume “grid” code and a smoothed-particle hydrodynamics (SPH) code. We find that there is agreement in both the ultimate outcomes of the evolutions and the intermediate stages if the initial conditions for each code are chosen to match as closely as possible. We find that even with closely matching initial setups, the time it takes to reach a concordant evolution differs between the two codes because the initial depth of contact cannot be matched exactly. There is a general tendency for SPH to yield higher mass transfer rates and faster evolution to the final outcome. We also present comparisons of simulations calculated from two different energy equations: in one series, we assume a polytropic equation of state and in the other series an ideal gas equation of state. In the latter series of simulations, an atmosphere forms around the accretor, which can exchange angular momentum and cause a more rapid loss of orbital angular momentum. In the simulations presented here, the effect of the ideal equation of state is to de-stabilize the binary in both SPH and grid simulations, but the effect is more pronounced in the grid code.

79 ASTRONOMY AND ASTROPHYSICS↗