Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grade”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

NEPP non-volatile memory : FY09 summary report

This report documents the activities and results of the fiscal year 2009 (FY09) funding for the NASA Electronic Parts and Packaging (NEPP) program for non-volatile memory (NVM) devices. The FY09 task was divided into two main efforts: 1. Development of in-house measurement capability for flash devices 2. Reliability characterization of multi-level vs. single-level flash devices The FY09 NEPP Non Volatile Memory study was organized into these two sections in recognition of the continued and increasing importance of NVM to NASA. All NASA missions use NVM for boot code storage and some limited data archiving. Space-grade NVM has lagged commercial NVM development by many orders of magnitude, however. This gap in density only continues to increase as space-grade memories remain constant in the 1–16 Mbit levels, while commercial flash-based devices shrink in size and double in capacity every 18 months. Commercial flash devices are now at the 32 Gbit level, 10,000 times denser than current NASA NVM. This FY marks the beginning of a significant technological transition in NVM for NASA. The aggressive scaling of commercial NVMs has, as a by-product, made some of the flash devices radiation-tolerant enough to be at least considered for low-level radiation environment missions [Irom 2008]. This NEPP task is focused on understanding the reliability and potential future applications of such highly scaled flash memories.

Heidecker, Jason↗

Sub-City-Scale Air Quality Forecasts Combining Models, Satellites, and Surface Measures

Poor air quality is a global major concern, especially in cities with their higher emissions and large numbers of exposed people. Air quality monitoring has traditionally relied on ground-based measurements from a few accurate but expensive regulatory-grade monitors, leading to limited spatial data coverage. More recently, these have been supplemented with other data sources, including satellite observations of pollutants, atmospheric chemistry model simulations, and low-cost monitors allowing for denser spatial data collection at the expense of lower accuracy compared to regulatory-grade monitors. Each of these air quality data sources have their own benefits and drawbacks, and so there is an opportunity to combine these data together while respecting their relative strengths and weaknesses in order to generate a more comprehensive and detailed picture of local air quality. I will present our current work towards such a combination, with a focus on producing higher spatial resolution estimates and near-term forecasts of Nitrogen Dioxide in urban areas in the United States. Our method combines data from the GEOS Composition Forecasting (GEOS-CF) model system, TROPOMI tropospheric NO2 satellite data products, and ground measurements from the EPA regulatory monitoring network using a combination of simple intuitive relationships and machine learning techniques. I will show the performance of this proposed method in several urban areas in the United States, comparing it with baseline approaches using single data sources separately. Overall, we find that combining these disparate datasets together leads to more accurate air quality forecasts in the target areas than is possible using each data source separately.

Air quality↗

Crowd Sourcing Medical Data Collection Using Medical Students

OBJECTIVE We undertook an upgrade of the Evidence Library database of NASA HRP’s Integrated Medical Model, assessing 120 medical conditions which integrate with a novel probabilistic risk assessment (IMPACT) tool of medical risk and resource utilization for long duration exploration human spaceflight. This data collection process included a selection of these conditions crowd sourced over one year via three 4-week medical student electives at the University of Colorado School of Medicine (IDPT 8059 Space Medicine: Human Spaceflight Factors & Medical Risk Assessment). Students undertook a rapid systematic review of each medical condition, under close preceptors with backgrounds in clinical medicine, library science, epidemiology, biostatistics, and evidence-based medicine. As part of the elective, students also received instruction in core space medicine concepts, evidence based medicine and problem based learning sessions as a flight surgeon supporting a simulated Mars mission. METHODS The list of 120 medical conditions includes both common, terrestrial illness/injury (epistaxis, diverticulitis) as well as spaceflight-specific ones (space adaptation conditions, EVA-related injuries). A rapid systematic review process was developed that would allow students to find the data for determining disease incidence/prevalence, return to definitive care (often a surrogate such as hospitalization rates), loss of crew life, and treatment duration. Each data point required a tailored, specialized search process using different databases and corresponding specialized search filters. Databases were selected on their ability to provide high quality literature in an efficient manner and prioritized by their ability to provide graded evidence via a set rubrics specific to human spaceflight. Students were responsible for performing all literature searches and identifying the highest quality available evidence for each data point. Completed student data sheets underwent initial review by faculty preceptors followed by a secondary editing review by the ExMC Clinical Science Team. RESULTS Over the course of three electives, approximately 105 medical conditions were researched by students using spreadsheets with pre-crafted search strategies. Overall, this process was successful in allowing students to perform the preponderance of work to update incidence, treatment duration, return to definitive care, and loss of crew life data points. Students were successful in running searches, identifying the necessary data points within the literature, and determining the types of terrestrial data that most aligns with the astronaut population for successful completion of their tasks. Limitations included variable student experience with search methodologies [PubMed], differing values of evidence grading [best practice evidence based medicine vs. relevant to spaceflight], and students’ unfamiliarity with spaceflight specific conditions. CONCLUSION Finding the relevant literature for medical conditions in spaceflight within terrestrial databases in a systematic method is time consuming and not intuitive. However, the stepwise process that balanced sensitivity with specificity allowed for students to be highly successful in a short amount of time. Additionally, as the process was refined over the course of three electives, preceptors were better able to anticipate where students were likely to encounter barriers, which allowed the course to be adjusted to account for certain data points needing more time for completion. This replicable process may be an efficient way to accomplish rapid systematic reviews for a large volume of data in a short amount of time.

J Lemery↗

Comparison of Multispectral Imaging and Traditional Fundoscopy in the Detection of Terrestrial Retinal and Optic Nerve Pathologies like those Encountered During and/or Immediately Following Long-Duration Spaceflight

INTRODUCTION: The purpose of this investigation was to evaluate if MultiColor Imaging (MCI) can replace color fundus photography (CFP) as a diagnostic screening tool during spaceflight. MCI significantly reduces crew time (approx. 115 minutes/session, 36 hours/year) by eliminating nominal on-orbit fundoscopy sessions, while also providing the option to capture a larger field of view (55 vs. 35). METHODS: A comprehensive PubMed literature search was conducted using the following key words: multicolor, multispectral, imaging, retina, choroid, optic nerve, optic disc, and papilledema. Publications were filtered based on optic nerve and chorioretinal pathologies matching those seen during or immediately after spaceflight: optic disc edema (ODE), cotton wool spots (CWS), retinal hemorrhage, pigment epithelial detachment (PED), and serous chorioretinopathy (SCR). In a separate effort, 44 multicolor images (30 abnormal) of terrestrial patients were graded and compared to corresponding color fundus images acquired at the Doheny Eye Centers and UCLA. RESULTS: The search identified 340 articles; 9 describing MCI in relevant pathologies, 6 comparing MCI to CFP. MCI is superior in detecting CWS (1 paper), PED (2 papers), retinal hemorrhages (2 papers), and choroidal folds (1 paper), and can better delineate extent or boundaries of subretinal fluid and identify areas of RPE damage in SCR (2 papers). On MCI, ODE was described as a hyperreflective ring with a green shift and indistinct disc margins, with equaldetectability as using CFP (3 papers). Grading at Doheny Eye Institute confirmed these findings. DISCUSSION: MCI can effectively detect all retinal and optic nerve findings detectable by CFP during and immediately post-spaceflight and represents a suitable replacement as an on-orbit diagnostic screening tool. Additionally, by eliminating the nominal on-orbit fundoscopy sessions, dozens of crew hours are spared per year by utilizing MCI.

Jorge Nagel↗

Shields-1 Dosimetry Measurements in Polar Low Earth Orbit

Shields-1, NORAD ID 43850, has been operating in polar low earth orbit since December 2018 at 85 degrees inclination and an initial altitude of 500 kilometers, beginning in solar minimum activity. It launched with the NASA CubeSat Launch Initiative (CSLI) ELaNaXIX mission. Shields-1 has 8 Teledyne dosimeters on board behind different shielding thicknesses. It is a technology demonstration of an atomic number (Z)-grade shielded electronics enclosure, 3 Z-grade shielding samples baselined with 4 aluminum samples having dosimeters behind each sample and inside the electronics enclosure. In addition to the technology demonstration, Shields-1 has been providing scientific dosimetry of energetic particles in the polar low earth orbit space radiation environment.

Shields-1↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide remains an option of choice for microbial control in spacecraft potable water systems. However, depletion of silver ions by wetted materials readily reduces ionic silver to nonbiocidal levels. This phenomenon occurs via various transport mechanisms at the liquid-solid interfaces between the silver-containing water and adjacent surfaces. Consequently, challenges remain in the design and/or selection of materials that can be used for the wetted system components that will help ensure silver is maintained at biocidal levels. Since silver has been baselined, and/or remains, as a potable water biocide option for several future spacecraft potable water systems, a multitiered approach is being investigated, looking at heritage materials, new processes, and/or alterative materials. This study conducted the application of eleven chemically-resistant coatings onto coupons that were cut out from three types of spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel) to investigate the performance of this material strategy as a barrier against silver depletion. In this investigation, the coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^(-1) and left to soak for predefined time periods. The concentration of the solution in contact with the coated samples was analyzed at various points via inductively coupled plasma mass spectrometry, and the measurements were interpreted as silver retention percentages over time. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination at diminishing silver depletion. The preliminary results demonstrate that some of the selected coatings succeeded at maintaining biocidal silver concentrations far beyond the corresponding base metal in a similar test. The knowledge acquired through this investigation supports the deploying of coatings on plumbing lines for the integration of biocidal silver in the water system architecture of a spacecraft. Nevertheless, further testing must be continued to assess the performance of these coatings on other wetted geometries and any implications of unifying this material strategy with traditional and developmental engineering design processes for spacecraft potable water systems.

water↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings↗

Exep: Environmental Testing of High-Actuator-Count Mems Deformable Mirrors for Space-Based Applications

Coronagraph instruments on future space telescopes will rely on deformable mirrors to create high contrast images for the direct detection of exoplanets. As part of the NASA Exoplanet Explorations Program’s coronagraph technology development efforts, two sets of Micro-electro-mechanical systems (MEMS) deformable mirrors manufactured by Boston Micromachines Corporation were exposed to vibration and thermal cycles representative of launch conditions. The first set were 952-actuator Kilo-DMs that successfully demonstrated 100% actuator survival and achieved ~1e-8 contrast after the environment test. The second round used an engineering-grade 2048-actuator deformable mirror on which few changes were identified after the environmental test. However, each actuator that changed behavior was flagged as anomalous beforehand or was directly adjacent to a defective actuator. From this result, we hypothesized that typical actuators on a science grade deformable mirror are robust to environmental testing. A third set of 2048-actuator deformable mirror have been procured for a planned test to characterize the deformable mirrors using interferometric measurements, contrast results on a new in-air coronagraph testbed, and infrared microscopy on the internal structure of the MEMS devices.

Lam, Charlie↗

Quiet Spacecraft Cabin Ventilation Fan: Vibration Measurements Results

The vibrations of a metal spacecraft cabin ventilation fan that tested in 2021 were greater than desired. We diagnosed the problem and modified the rotor assembly in 2022 to try and reduce those vibrations. The design changes included a new lighter rotor with a tighter balance tolerance, a new collet to attach the rotor to the motor shaft more securely and repeatably, and a new bracket to center and hold the motor a little better. The redesigned rotor was tested in 2023 and vibrations were significantly reduced. The measured peak vibration was reduced from 4 mm/s second to less than 1 mm/s, corresponding to a reduction from a balance grade G4 to a grade G 0.6.

Fan, Noise, Ventilation↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings↗

Commercial Smallsat Data Acquisition Program: Airbus U.S. Synthetic Aperture Radar Quality Assessment Summary

Quality assessment of the Airbus X-band Synthetic Aperture Radar (SAR) satellite products was conducted by the Commercial Smallsat Data Acquisition (CSDA) program’s radar subject matter experts, following the Joint NASA/ESA (European Space Agency) assessment draft guidelines. All three Airbus SAR spacecraft (TerraSAR-X, TanDEM-X, and PAZ) are based on the TerraSAR-X platform, and each have an active phased array antenna that is 4.8 x 0.7 m in the along-track and cross-track dimensions, respectively. TerraSAR-X and TanDEM-X are in a helical orbit, creating a bistatic imaging geometry, in addition to being capable of independent monostatic observations. The PAZ mission follows TerraSAR-X and TanDEM-X in the same 11-day orbit with a 5.5-day lag. TerraSAR-X and TanDEM-X are designed, developed, and operated through a Public-Private Partnership, while PAZ is a dual-use mission (civil and defense agencies), funded and owned by the Spanish Ministry of Defense and managed by Hisdesat (Hisdesat Servicios Estratégicos, S.A.), a Spanish private communications company. The assessment presented in this document is divided into two main parts: documentation review and the assessment of test datasets. The documentation review in sections 2.1 through 2.4 includes the assessment of the Airbus documentation provided to the CSDA evaluation team. The grading of these documents is given in columns 1-4 of the maturity matrix shown in section 1.1. Section 2.5 summarizes the evaluation performed by NASA using the data purchased through the CSDA program. The grading for this is given in the last column of the maturity matrix. Section 3 provides more detailed explanations on the methods and the results of the data analysis performed by NASA. Only the documents provided by Airbus for the evaluation were considered for the review. Additional documentation with more detailed description of the calibration and validation procedures may be available online but were not considered for this evaluation. The product information provided in the available documentation (RD-1, RD-2) and the product metadata together provided adequate information to work with the data. The product details in the metadata included the required information to work with the data in the common XML file format. Metrological traceability documentation was not provided to CSDA. All relevant characterization of the SAR system and data were provided, and the metadata include all relevant ancillary information. Documentation provided to CSDA included limited pre-flight and post-launch calibration information.

Batuhan Osmanoglu↗

Testing of the ISS’s Charcoal HEPA Integrated Particle Scrubber (CHIPS) Filters to Ascertain an Efficiency Curve and Most Penetrating Particle Size

High air quality is a top priority in hermetically sealed environments, such as the International Space Station (ISS). Aerosol particulate filtration on the ISS is achieved via 21 HEPA filters. Traditional HEPA filters have an efficiency of 99.97%, but HEPA filters aboard the ISS have been found to achieve 99.99% efficiency. This may be due to the flight-grade HEPA filters chosen or, less likely, that they are combined with activated charcoal filters for siloxane removal in a combination referred to as Charcoal HEPA Integrated Particle Scrubbers (CHIPS) filters. All filters have a Most Penetrating Particle Size (MPPS), but, until now, the MPPS and efficiency curve of the CHIPS filters was not known. The efficiency curve of the CHIPS filters was ascertained at NASA Glenn Research Center through standard salt crystal aerosolization. This method was selected over aerosolized oil droplets due to a desire to preserve the filter’s function for further testing. The CHIPS filters were tested as they are oriented on the ISS (activated charcoal filter followed by a flight-grade HEPA filter), with the HEPA portion alone, and with the activated charcoal portion alone. The results of this experiment are generally useful but can be especially useful for the microbiology and Environmental Control and Life Support Systems (ECLSS). This is due to microbial contamination being a potential concern in the air revitalization systems on the ISS. Knowing the MMPS of the CHIPS filters, in conjunction with levels of airborne microbes, is useful for predicting which and how many microbes are likely to get through the HEPA filters that sit in the beginning of the ISS airstream. It may also be useful to other groups at NASA to know how many particulates are able to pass through high-efficiency filtration, and even for healthcare cleanrooms and other air purification pursuits.

A Nicolas Whitlock↗

Structural Differences Between Insoluble Organic Matter in Matrix and Chondrules: Potential Insights into Pre-Parent Body Thermal Alteration

Carbon is a major molecular constituent of primitive chondrites of low petrologic grade. A majority of the carbon (>70%) is in the insoluble organic matter (IOM) fraction that cannot be extracted from the meteorite sample using polar or nonpolar solvents. The IOM is comprised of a kerogen-like macromolecular carbon (MMC) structure that consists of aromatic rings connected by highly branching aliphatic chains. Raman spectroscopy is highly sensitive to IOM due to a strong resonance enhancement that occurs for all visible excitation wavelengths, making Raman a powerful in-situ probe of IOM. The Raman spectrum of IOM consists of two primary bands, the G band originates from all carbon-carbon bonds in the MMC structure and the D band that originates from carbon 6-member ring breathing motions. The peak position and width of the G and D bands probe the structure of the IOM. Using Raman spectroscopy, the IOM structure has been shown to correlate with the thermal alteration history of the meteorite, allowing for petrologic grade classification to the tenths place in the 3.0-3.9 range. Here, we have collected Raman images of GRA 06100,41 (CR2) for the examination of the IOM spatial distribution and observe significant differences between the IOM in the matrix and chondrules.

R S Jakubek↗

Development of optic disc edema during 30 days of hypercapnic head down tilt bed rest is associated with short sleep duration and blunted temperature amplitude

Consequences of sleep and circadian rhythm disturbances include many neurophysiological sequelae, especially when combined with spaceflight stressors, and are therefore hypothesized to contribute to the development of optic disc edema observed in astronauts. Additionally, chronically elevated carbon dioxide (CO 2 ) levels on the International Space Station may contribute to the observed sleep disturbances in astronauts. Here we determined if the spaceflight analogue head-down tilt bed rest (HDTBR) combined with elevated CO 2 levels influenced sleep and core temperature and was associated the development of optic disc edema. Healthy participants (5 female, 6 male) aged 25-50 years, underwent thirty days of strict 6° HDTBR in a mild hypercapnic environment (ambient PCO 2 = 4 mmHg) with measures of sleep, 24-hour core temperature, overnight arterialized CO2, and Frisén grade edema collected pre-HDTBR, on HDTBR days 4, 17, 28, and post-HDTBR days 4 and 10. During all HDTBR time points, sleep, core temperature, and overnight arterialized CO 2 were not statistically significantly different than the pre-HDTBR measurements. However, independent of the HDTBR intervention, the odds ratios (mean [95% CI]) for developing Frisén grade optic disc edema were statistically significant for each hour below the mean total sleep time (2.2 [1.1-4.4]) and stage 2 NREM sleep (4.8 [1.3-18.6]), and above the mean for wake after sleep onset (3.6 [1.2-10.6]) and for each 0.1°C decrease in core temperature amplitude below the mean (4.0 [1.4-11.7]).These data suggest that optic disc edema occurring during HDTBR was more likely to occur in those with short sleep duration and blunted temperature amplitude.

Kate H. Christian↗

Lunar Node – 1: Initial Flight Results and the Role of Surface Psuedolites in Lunar Navigation

On February 22, 2024, the Intuitive Machines IM-1 NOVA-C lander, nick-named Odysseus, landed on the lunar surface, carrying with it a cadre of NASA scientific and technology demonstration payloads. These payloads and missions marked the first delivery of NASA instruments to operate from the lunar surface since the Apollo landings. One of these payloads is Lunar Node -1 (LN-1), a navigation beacon demonstration mission. The payload was designed and built by NASA’s Marshall Space Flight Center. The payload’s main goal was to demonstrate and provide insight into the use of lunar surface-based radio navigation aids. As part of the mission, LN-1 successfully conducted multiple one-way transmissions from the NOVA-C vehicle to Deep Space Network ground receivers using its onboard S-band transmitter, while being disciplined by an onboard Space Chip Scale Atomic Clock. LN-1 transmitted to DSN on an almost daily basis during transit to the moon, including two surface passes. The payload was originally plan to conduct 7-10 days of surface operation as an always-on beacon. These passes focused on evaluating two main navigation approaches: performance and stability of ranging using time-based transfer techniques on a cubesat size and grade platform, as well as one-way psuedonoise ranging approaches. To assess performance, the measurements were compared to independent navigation solutions using multiple approaches including: one-way Doppler tracking, two-way Doppler Tracking, and visual verification of the landing location provided by visual observations from orbital platforms. While the mission only conducted limited surface operations, the data provides some initial insight to performance form the lunar surface. These results are compared with initial ground-based testing as well as continued evaluation of the flight-space platform using multiple grades of oscillators for maintaining clock and frequency stability. These focus on the timing stability of platform in a deep-space environment as well variations in state determination. Given these insights, this paper provides additional description and evaluation of how this approach can be utilized as part of a broader lunar navigation architecture, such as being developed and deployed across multiple international space agencies. Analysis is provided to develop overall timing requirements and assessment of operational scenarios, such as orbit and surface location determination. In addition, the results support discussion as to how surface pseudolites could best be used within existing standard signal definitions, such as defined in the LunaNet Interoperability Specifications. This will consider concerns such as the near-/far- problem as well as operational considerations, including whether a beacon is better suited as two- or one-way ranging platform. The use cases are focused on how these psuedolites can provide additional coverage to augment and support planned operational coverage. For example, this analysis provides analysis of mid-latitude surface missions, where there may be limited geometry and availability of orbital relays. The results will show how these navigation psuedolites can fit within the developing architecture to provide additional robustness, capability, and support multiple use cases. Lastly, the paper will discuss challenges and next steps to be addressed in the implementation and testing of a follow-on payload and a continued path towards demonstration and integration of this capability into Lunar PNT architectures.

Evan Anzalone↗

Lunar Node – 1: Initial Flight Results and the Role of Surface Psuedolites in Lunar Navigation

On February 22, 2024, Intuitive Machines NOVA-C lander, nick-named Odysseus, landed on the lunar surface, carrying with it a cadre of NASA scientific and technology demonstration payloads. These payloads and missions marked the first delivery of NASA instruments to operate from the lunar surface since the Apollo landings. One of these payloads is Lunar Node -1 (LN-1), a navigation beacon demonstration mission. The payload was designed and built by NASA’s Marshall Space Flight Center. The payload’s main goal was to demonstrate and provide insight into the use of lunar surface-based radio navigation aids. As part of the mission, LN-1 successfully conducted multiple one-way transmissions from the NOVA-C vehicle to Deep Space Network ground receivers using its onboard S-band transmitter, while being disciplined by an onboard Space Chip Scale Atomic Clock. LN-1 transmitted to DSN on an almost daily basis during transit to the moon, including two surface passes. The payload was originally plan to conduct 7-10 days of surface operation as an always-on beacon. These passes focused on evaluating two main navigation approaches: performance and stability of ranging using time-based transfer techniques on a cubesat size and grade platform, as well as one-way psuedonoise ranging approaches. To assess performance, the measurements were compared to independent navigation solutions using multiple approaches including: one-way Doppler tracking, two-way Doppler Tracking, and visual verification of the landing location provided by visual observations from orbital platforms. While the mission only conducted limited surface operations, the data provides some initial insight to performance form the lunar surface. These results are compared with initial ground-based testing as well as continued evaluation of the flight-space platform using multiple grades of oscillators for maintaining clock and frequency stability. These focus on the timing stability of platform in a deep-space environment as well variations in state determination. Given these insights, this paper provides additional description and evaluation of how this approach can be utilized as part of a broader lunar navigation architecture, such as being developed and deployed across multiple international space agencies. Analysis is provided to develop overall timing requirements and assessment of operational scenarios, such as orbit and surface location determination. In addition, the results support discussion as to how surface pseudolites could best be used within existing standard signal definitions, such as defined in the LunaNet Interoperability Specifications. This will consider concerns such as the near-/far- problem as well as operational considerations, including whether a beacon is better suited as two- or one-way ranging platform. The use cases are focused on how these psuedolites can provide additional coverage to augment and support planned operational coverage. For example, this analysis provides analysis of mid-latitude surface missions, where there may be limited geometry and availability of orbital relays. The results will show how these navigation psuedolites can fit within the developing architecture to provide additional robustness, capability, and support multiple use cases. Lastly, the paper will discuss challenges and next steps to be addressed in the implementation and testing of a follow-on payload and a continued path towards demonstration and integration of this capability into Lunar PNT architectures.

Evan J Anzalone↗

High Energy Hydroforming Friction Stir Welded 2050 Al-Li Blanks for Aerospace Domes and Cones

Friction stir welded (FSW) aluminum blanks offer larger preform sizes than available from the mill in single width plates. Large blanks made from aerospace-grade aluminum alloys are essential for making large domes and cones for launch vehicles and crew vehicles. Previous research efforts have demonstrated >5m FSW blanks can be formed into large domes or cones using spin forming, but the subsequent solution heat treatment consistently led to abnormal grain growth (AGG). The AGG phenomenon occurs because the FSW blanks must be spin formed in the -O annealed temper to withstand the high strain process without cracking. Subsequently, the solution heat treatment process leads to the onset of AGG, whereby a small number of grains grow much larger than the surrounding matrix. Ultimately, the large grains and bimodal grain-size distribution leads to unacceptable ductility in the short-transverse direction of the part. Alternatively, explosive hydroforming is a nascent process that can be applied to large and thick aerospace-grade aluminum alloy blanks in the -T3 temper and only require a post-forming artificial aging process to a -T8. Avoiding the solution heat treatment (SHT) process mitigates AGG, and also eliminates the need for very rare drop-furnace quench baths that can accommodate a part size larger than 5m in diameter. This presentation summarizes a Lockheed Martin-led effort that demonstrated explosive hydroforming of a 1.9m diameter, 39mm thick 2050 aluminum lithium FSW blank. Details will be provided on the process flow, mechanical properties, and metallographic analyses. This work was performed in partnership with NASA Langley Research Center (LaRC) under a NASA Announcement of Collaboration Opportunities program.

Friction stir welded blank↗

Performance of ASTRO-H Hard X-Ray Telescope (HXT)

The Japanese X-ray Astronomy Satellite, Hitomi (ASTRO-H) carries hard X-ray imaging system, covering the energy band from 5 keV to 80 keV. The hard X-ray imaging system consists of two hard X-ray telescopes (HXT) and two hard X-ray imagers (HXI). The HXT employs tightly-nested, conically-approximated thin foil Wolter-I optics. The mirror surfaces of HXT were coated with PtC depth-graded multilayers. We carried out ground calibrations of HXTs at the synchrotron radiation facility SPring-8 BL20B2 in Japan, and found that total effective area of two HXTs was about 350 sq cm at 30 keV, and the half power diameter of HXT was about 1.9. After the launch of Hitomi, Hitomi observed several targets during the initial functional verification of the onboard instruments. The Hitomi software and calibration team (SCT) provided the Hitomis data of G21.5-0.9, a pulsar wind nebula, to the hardware team for the purpose of the instrument calibration. Through the analysis of the in-flight data, we have confirmed that the X-ray performance of HXTs in orbit was consistent with that estimated by the ground calibrations.

hard X-ray telescope↗